Department of Radiology UNIVERSITY OF PENNSYLVANIA 1 Investigation of LaBr 3 Detector Timing Resolution A.Kuhn 1, S. Surti 1, K.S. Shah 2, and J.S. Karp.

Slides:



Advertisements
Similar presentations
1 Proton detection with the R3B calorimeter, two layer solution IEM-CSIC sept report MINISTERIO DE EDUCACIÓN Y CIENCIA CONSEJO SUPERIOR DE INVESTIGACIONES.
Advertisements

1 Continuous Scintillator Slab with Microchannel Plate PMT for PET Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat 2, Fukun Tang 2,
Detector systems 1) Anti-Compton spectrometers 2) Pair spectrometers 3) Crystal spheres, walls, complex set-ups of semiconductor and scintillation detectors.
PET Design: Simulation Studies using GEANT4 and GATE - Status Report - Martin Göttlich DESY.
DESCANT and  -delayed neutron measurements at TRIUMF Paul Garrett University of Guelph.
Chapter 8 Planar Scintigaraphy
Figure 5. Histogram of the decay constant. Black curves: raw histograms; Blue curve: Gaussian fit to the histogram from the 20GS/s waveform; Red curve:
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Geant4 simulations for the calorimeter prototypes D. Di Julio, J. Cederkäll, P. Golubev, B. Jakobsson Lund University, Lund, Sweden.
Observation of Fast Scintillation of Cryogenic PbI 2 with VLPCs William W. Moses, 1* W.- Seng Choong, 1 Stephen E. Derenzo, 1 Alan D. Bross, 2 Robert Dysert,
Signal Analysis and Processing David Scraggs. Overview Introduction to Position Resolution Induced Charges Wavelet Transform Future Work Discussion.
ipno.in2p3.fr Milano - October 2006IPNO-RDD-Jean Peyré1 Measurements of CsI(Tl) Crystals with PMT and APD Jean Peyré Milano - Oct 2006.
1 A Design of PET detector using Microchannel Plate PMT with Transmission Line Readout Heejong Kim 1, Chien-Min Kao 1, Chin-Tu Chen 1, Jean-Francois Genat.
Crystals and related topics J. Gerl, GSI NUSTAR Calorimeter Working Group Meeting June 17, 2005 Valencia.
GAMMA RAY SPECTROSCOPY
Timing Properties of T0 Detectors At PHOBOS Saba Zuberi, Erik Johnson, Nazim Khan, Frank Wolfs, Wojtek Skulski University of Rochester.
Signal Analysis and Processing for SmartPET D. Scraggs, A. Boston, H Boston, R Cooper, A Mather, G Turk University of Liverpool C. Hall, I. Lazarus Daresbury.
The UC Simulation of Picosecond Detectors Pico-Sec Timing Hardware Workshop November 18, 2005 Timothy Credo.
Gamma Spectroscopy HPT TVAN Technical Training
Scintillation Detectors
Copyright © Hamamatsu Photonics K.K. All Rights Reserved. Oct at NNN07 Workshop Hamamatsu Photonics Electron Tube Division Recent Progress in PMTs.
1 Light Collection  Once light is produced in a scintillator it must collected, transported, and coupled to some device that can convert it into an electrical.
Optimization of LSO for Time-of-Flight PET
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
1 Scintillators  One of the most widely used particle detection techniques Ionization -> Excitation -> Photons -> Electronic conversion -> Amplification.
Report on SiPM Tests SiPM as a alternative photo detector to replace PMT. Qauntify basic characteristics Measure Energy, Timing resolution Develop simulation.
Fast Timing with Diamond Detectors Lianne Scruton.
Experimental set-up Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE Multi-Channel MCP PMTs S.Korpar a,b, R.Dolenec.
11 th iWoRiD, Prague, Czech Republic Low-power Wide-dynamic-range Readout System for a 64-channel Multi-anode PMT of a Scintillation Gamma Camera Satoru.
RF Cherenkov TOF and TOP Detectors for JLab Physics Applications A. Margaryan.
TU Delft IRI-ST Inorganic Scintillators in Medical-imaging Detectors C.W.E. van Eijk A msterdam, 9 September 2002.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
HEALTH Novel MR-compatible PET detectors for simultaneous PET/MRI imaging FP7-HEALTH-2009-single-stage The focus should be to develop novel.
Nuclear Medicine: Planar Imaging and the Gamma Camera Katrina Cockburn Nuclear Medicine Physicist.
1 Satoshi Mihara for the   e  collaboration, review meeting at PSI, Jul 2002 Photon Detector Satoshi Mihara ICEPP, Univ. of Tokyo 1.Large Prototype.
Optimization of Detectors for Time of Flight PET Marek Moszyński, Tomasz Szczęśniak, Soltan Institute for Nuclear Studies, Otwock-Świerk, Poland.
Gamma-induced positron lifetime and age-momentum
Increase in Photon Collection from a YAP:Ce Matrix Coupled to Wave Lenght Shifting Fibres N. Belcari a, A. Del Guerra a, A. Vaiano a, C. Damiani b, G.
1 Geant4 Simulation :MCP PET 4’’(102mm) Scintillator ( LSO) 4’’(102mm) 10mm Glass( Borosilicate) PhotocathodeI(Carbon) Space(Vacuum) MCP(Alumina) Space(Vacumm)
Development of a Gamma Camera Based on an 88 Array of LaBr3(Ce) Scintillator Pixels Coupled to a 64-channel Multi-anode PMT Hidetoshi Kubo, K.Hattori,
Experimental Nuclear Physics Some Recent Activities 1.Development of a detector for low-energy neutrons a. Hardware -- A Novel Design Idea b. Measure the.
Medical applications of particle physics General characteristics of detectors (5 th Chapter) ASLI YILDIRIM.
WIMP search Result from KIMS experiments Kim Seung Cheon (DMRC,SNU)
Electron tracking Compton camera NASA/WMAP Science Team  -PIC We report on an improvement on data acquisition for a Time Projection Chamber (TPC) based.
Timing in Thick Silicon Detectors Andrej Studen, University of Michigan, CIMA collaboration.
Scintillators suitable for PET applications must be characterized by a high efficiency for gamma-ray detection, determined by a high density and atomic.
1 Nuclear Medicine SPECT and PET. 2 a good book! SR Cherry, JA Sorenson, ME Phelps Physics in Nuclear Medicine Saunders, 2012.
Peter Dendooven LaBr 3 and LYSO monolithic crystals coupled to photosensor arrays for TOF-PET Physics for Health in Europe Workshop February 2-4, 2010,
Lecture 12  Last Week Summary  Sources of Image Degradation  Quality Control  The Sinogram  Introduction to Image Processing.
Potential Advantages of Digitally Sampling Scintillation Pulses in Time Determination in PET Q. Xie 1,2, C.-M. Kao 1, X. Wang 2, N. Guo 2, C. Zhu 2, H.
A Multi-Threshold Method for TOF-PET Signal Processing Heejong Kim 1, Chien-Min Kao 1, Qingguo Xie 1, Chin-Tu Chen 1, Octavia Biris 2, Jialin Lin 2, Fukun.
Nuclear Medicine Physics and Equipment 243 RAD 1 Dr. Abdo Mansour Assistant Professor of radiology
Nuclear Medicine Instrumentation 242 NMT 1 Dr. Abdo Mansour Assistant Professor of radiology
Photon Transport Monte Carlo September 27, 2004 Matthew Jones/Riei IshizikiPurdue University Overview Physical processes PMT and electronics response Some.
Scintillating Bolometers – Rejection of background due to standard two-neutrino double beta decay D.M. Chernyak 1,2, F.A. Danevich 2, A. Giuliani 1, M.
Hybrid Detector(s) for Complete Gamma Ray Spectroscopy S. S. Bhattacharjee, R Raut, S S Ghugre, A K Sinha UGC-DAE Consortium For Scientific Research, Kolkata.
P. Lecoq CERN2 February ENVISION WP2 Meeting CERN Group contribution to ENVISION WP2 Paul Lecoq CERN, Geneva.
Abstract The shape of the current pulse produced by a SiPM in response to an incident photon is sensibly affected by the characteristics of the FE used.
Performance of LYSO and CeBr3 crystals readout by SiPM
Scintillation Science and Nuclear Medical Imaging
Qingguo Xie1,2, Chien-Min Kao1, Xi Wang2, Ning Guo2,
Inorganic Scintillators in Medical-imaging Detectors C. W. E
Deng Ziyan Jan 10-12, 2006 BESIII Collaboration Meeting
Scintillation Counter
A Multi-Threshold Method for TOF-PET Signal Processing
MCP PET Simulation (7) – Pixelated X-tal
Development of a Large Area Gamma-ray Detector
md-NUV PET project meeting
一种基于晶体间光分享原理的深度测量PET探测器
Status Report on MCP PET Simulation
Presentation transcript:

Department of Radiology UNIVERSITY OF PENNSYLVANIA 1 Investigation of LaBr 3 Detector Timing Resolution A.Kuhn 1, S. Surti 1, K.S. Shah 2, and J.S. Karp 1 1 Department of Radiology, University of Pennsylvania, Philadelphia, PA 2 Radiation Monitoring Devices, Watertown, MA

Department of Radiology UNIVERSITY OF PENNSYLVANIA 2 Abstract Lanthanum bromide (LaBr 3 ) scintillation detectors are currently being developed for use in time-of-flight (TOF) PET. In recent years, studies have been aimed at the parameterization of the LaBr 3 scintillation properties. We have utilized the findings of these studies in the development of simulation tools to investigate and predict the performance of TOF PET detectors of realistic geometries. Here, we present a model to simulate the combined scintillator and photomultiplier tube (PMT) response to incident photons. This model allows us to study the effects of crystal response, geometry, and surface finish, PMT response, transit time spread, and noise, as well as discrimination techniques on the coincidence resolving time achievable in various detector configurations. Results from the simulations are benchmarked against several experimental measurements with two different PMTs and LaBr 3 crystals of varying cerium concentration and geometry. A comparison is also made to the time resolution achievable with LYSO. Good agreement between measurement and simulation has been achieved with detectors consisting of 4x4x30 mm 3 crystals suitable for use in a TOF PET scanner. Ultimately, this guides the improvement of TOF detectors by identifying the individual contribution of each detector component on the time resolution that can be achieved.

Department of Radiology UNIVERSITY OF PENNSYLVANIA 3 Properties of LaBr 3 Fast Rise and Decay Times –Reduction in random coincidences –Excellent coincidence time resolution Excellent Energy Resolution –Reduction in scattered events and random coincidences Very High Light Output –Good crystal discrimination with long narrow crystals (i.e., 4x4x30 mm 3 ) Low Melting Point (783 ˚C) –Easier crystal growth, reduction in material costs Scintillator  (ns)  (cm -1 )  E/E (%) At 662 keV Relative Light Output (%) NaI(Tl) BGO CsF BaF GSO LSO/LYSO LaBr Values obtained from reference [5-11]

Department of Radiology UNIVERSITY OF PENNSYLVANIA 4 Photon Transport (MonteCrystal): –Gamma-ray trajectory –Tracks gamma interactions (Compton & Photoelectric) –Defined detector materials & geometry Crystal type (LaBr 3 and LYSO) Crystal Size (varied crystal length with 4x4 mm 2 cross-section) Single crystal/PMT and Anger-logic detector geometries –Scintillation photons generated at each interaction point Crystal scintillation response parameterized [3] –Path of scintillation photons traced Modeled crystal surfaces, boundaries and reflector material Model Introduction (I)

Department of Radiology UNIVERSITY OF PENNSYLVANIA 5 Model Introduction (II) Modeled PMT Parameters –Transit time spread (jitter) –Quantum efficiency –Response of PMT (single photoelectron) –Signal noise from dark current Discriminator Time Pick-off –Leading edge model Two PMTs Modeled The XP20D0 represents good timing performance in a 2 inch diameter PMT and is being used in our prototype LaBr 3 scanner, the HM R4998 was chosen because of its extremely fast response and low TTS.

Department of Radiology UNIVERSITY OF PENNSYLVANIA 6 Model - Block Diagram Gamma ray Transport Interactions in Crystal (Compton & Photoelectric) Detector Geometry Crystal Response Crystal Surface And Reflector Properties Generation of Scintillation Photons Track Scintillation Photons PMT Transit Time Spread Convolve PMT Response Noise Anode Signal Threshold Setting DiscriminatorEvent Time PMT & Signal Model Montecrystal

Department of Radiology UNIVERSITY OF PENNSYLVANIA 7 Simulation of Pulse Shapes 5.0% Ce LaBr 3 Response Taken from reference [3] Photoelectrons created at PMT cathode Measured single photoelectron response for XP20D0 Measured Noise Histogram XP20D0 Simulated Pulse Shape 5.0% Ce LaBr 3 Response at photocathode is convolved with the measured single photo- electron PMT response Dark current noise (Gaussian fit to measured noise histogram) is added to the simulated PMT pulse shape

Department of Radiology UNIVERSITY OF PENNSYLVANIA 8 Single Crystal on XP20D0 PMT SimulationMeasurement Rise time of 30% Ce LaBr 3 (~3.5 ns) is faster than 5.0% Ce LaBr 3 (~5 ns) Simulated pulse shapes have slightly faster rise and decay compared to those measured due to the finite response of the oscilloscope used to record the pulses LYSO pulses have ~20% signal amplitude compared to LaBr 3 All Crystals are 4x4x30 mm 3 Measured pulse shapes include oscilloscope response LYSO

Department of Radiology UNIVERSITY OF PENNSYLVANIA 9 Single Crystal on HM R4998 PMT Simulation Measurement Response of R4998 is faster than XP20D0 Reduced rise time of 30% Ce LaBr 3 (~2 ns) and 5.0% Ce LaBr 3 (~3 ns), thus improving the ability to accurately determine the start time of the pulses All Crystals are 4x4x30 mm 3 Measured pulse shapes include oscilloscope response LYSO

Department of Radiology UNIVERSITY OF PENNSYLVANIA 10 Relative Light Output: Crystal Surface Finish Crystal cross-section is 4x4 mm 2 Comparison of light collection for various crystal surface finishes Large light loss for a crystal with all diffuse surfaces Previously tested crystal samples indicate that the light output behavior is comparable to the simulation of a crystal with both specular and diffuse surfaces (i.e., 1 diffuse and 4 specular surfaces) for crystal lengths up to 30 mm (i.e., ~30% reduction in light collection compared to very small samples) Simulated Light Collection

Department of Radiology UNIVERSITY OF PENNSYLVANIA 11 Coincidence Time Resolution: LaBr 3 : 5.0% Ce Coupled Directly to PMT Simulated Coincidence Time Resolution XP20D0 HM R4998 (Crystal cross-section is 4x4 mm 2 ) - Measured resolution with XP20D0 - Measured resolution with HM R4998 Measured Coincidence Time Resolution Two 5.0%Ce LaBr 3 (4x4x30 mm 3 ) XP20D0 HM R4998 FWHM 280 ps FWHM 240 ps Simulation

Department of Radiology UNIVERSITY OF PENNSYLVANIA 12 Coincidence Time Resolution: LaBr 3 : 30% Ce Crystal Coupled Directly to PMT (Crystal cross-section is 4x4 mm 2 ) Simulated Coincidence Time Resolution XP20D0 HM R Measured resolution on XP20D0 - Measured resolution on HM R4998 Measured Coincidence Time Resolution Two 30%Ce LaBr 3 (4x4x5 mm 3 ) XP20D0 HM R4998 FWHM 190 ps FWHM 145 ps Simulation

Department of Radiology UNIVERSITY OF PENNSYLVANIA 13 Coincidence Time Resolution: LYSO Crystal Coupled Directly to PMT (Crystal cross-section is 4x4 mm 2 ) Simulated Coincidence Time Resolution XP20D0 HM R Measured resolution on XP20D0 - Measured resolution on HM R4998 Measured Coincidence Time Resolution Two LYSO crystals (4x4x20 mm 3 ) XP20D0 HM R4998 FWHM 380 ps FWHM 310 ps Simulation

Department of Radiology UNIVERSITY OF PENNSYLVANIA 14 Detector Geometry –7 PMTs coupled to a light guide and 4x4x30 mm 3 crystal array PMT transit times varied by ~ ps Simulation indicates a significant improvement in time resolution can be achieved by utilizing a PMT with faster response Anger-logic Detector: Coincidence Time Resolution 7 XP20D0’s: Coincidence Time Resolution 7 HM R4998’s: Coincidence Time Resolution

Department of Radiology UNIVERSITY OF PENNSYLVANIA 15 Conclusions Simulated time resolution is in good agreement with the measured data points for LaBr 3 and LYSO crystals coupled directly to PMTs as well as in an Anger-logic design The faster response and lower transit time spread of the HM R4998 PMT leads to a significant improvement in the coincidence time resolution achieved Simulation and experimental measurements with 30% Ce LaBr 3 indicate an improvement in coincidence time resolution over the 5.0% Ce LaBr 3 on the HM R4998 PMT due to the faster response Utilizing a PMT with the properties of the HM R4998 in an Anger-logic detector design can potentially yield a coincidence time resolution of ~200 ps with LaBr 3 and ~400 ps with LYSO

Department of Radiology UNIVERSITY OF PENNSYLVANIA 16 Acknowledgments This work was supported by NIH R33EB and a research agreement with Saint-Gobain. We would like to thank the research members at Saint-Gobain and Radiation Monitoring Devices for their continued support. References [1] A. Kuhn, S. Surti, J. S. Karp, and et. al, ”Performance Assessment of Pixelated LaBr 3 Detector Modules for TOF PET,” TNS, 51, no. 5, October [2] A. Kuhn, S. Surti, J. S. Karp, and et. al, ”Design of a Lanthanum Bromide Detector for Time-of-Flight PET,” TNS, 51, no. 5, October [3] J. Glodo, W.W. Moses, W.M. Higgins, E.V.D. van Loef, P. Wong, S.E. Derenzo, M.J. Weber, K.S. Shah, “Effects of Ce Concentration on Scintillation Properties of LaBr 3 :Ce,” Nuclear Science Symposium Conference Record, 2004 IEEE Volume 2, Oct Page(s): [4] S. Surti, J. S. Karp and G. Muehllehner, " Image quality assessment of LaBr 3 -based whole-body 3D PET scanners: A Monte Carlo Evaluation," PMB, 49, , [5] S. Surti, J. S. Karp, G. Muehllehner, and P.S. Raby, ”Investigation of Lanthanum Scintillators for 3-D PET,” TNS, 50, no. 3, , [6] S. Surti, J. S. Karp and G. Muehllehner, " Evaluation of Pixelated NaI(Tl) Detectors for PET," TNS, 50, no. 1, 24-31, [7] K. Shah, J. Glodo, M. Klugerman, and et. al., "LaBr 3 :Ce scintillators for gamma ray spectroscopy," TNS, 50, no. 6, , [8] C. W. E. van Eijk, "Inorganic scintillators in medical imaging,” PMB., 47, R85-R106, [9] W. Moses and S. Derenzo, "Prospects for time-of-flight pet using LSO scintillator," TNS, 46, , [10] E. van Loef, P. D. P, C. van Eijk, K. Kramer, and H. Gudel, "High energy-resolution scintillator: Ce3+ activated LaCl 3.," Appl. Phys. Lett., 77, , [11] E. van Loef, P. D. P, C. van Eijk, K. Kramer, and H. Gudel, "High energy-resolution scintillator: Ce3+ activated LaBr 3.,”Appl. Phys. Lett., 79, , 2001.