Yokogawa Electric Corporation Copyright © Yokogawa Electric Corporation Device Capabilities Yokogawa vs. Honeywell (incl. Flowserve positioner) May 16,

Slides:



Advertisements
Similar presentations
Schutzvermerk nach DIN 34 beachten XControl XC100 + XI/OC I/O-Modules + XVision Text-Display The convincing machine and system control by Moeller XControl.
Advertisements

Yokogawa Network Solutions Presents:
DeltaV Tune for Fieldbus PID
RWD CONTROLLERS TECHNICAL
Basic Jens Neigaard.
mA Discrete I/O Foundation Fieldbus Control System.
Creating A Better Tomorrow With Trustworthy Technology ADVANCED AUTOMATION WITH FUJI INTELLIGENT PRODUCTS The New Revolution of Fuji Electric’s Electronic.
Competition Other types of flow meters Thermal Mass flow competition.
Achieving Target Control Performance Using Fieldbus Devices Achieving Target Control Performance Using Fieldbus Devices.
Yokogawa Corporation of America Copyright © Yokogawa Electric Corporation Digital Sensor Technology.
DYNAPAC F1000T/W Paver Controller System
1 Process Control and Data Acquisition Systems CM4120 Chemical Plant Operations.
File/ 1 Primary colours Secondary colours Remember to change file name 28pt Ariel bold 18pt Ariel bold l Distributed PID Control and I/O What is.
Process Control and Data Acquisition Systems
Lecture – 7 Basic input and output
Fischertechnik ® Interface Connections. The Serial Interface Connects the Computer with the fischertechnik ® model
VAC - Ctrl System 04Nov2011. Some points to be discussed Give support for the cryogenic control system prepared by Nikhef team for Cryotrap (and Genova.
SCADA and Telemetry Presented By:.
Page 1 ADAM-6000 Web-enabled Smart I/O Γιάννης Στάβαρης Technical Manager Ιούνιος 26, 2007.
March 2010 Hastings Product Training Flow Products Overview.
Progress Report on CGSE Control System Project Team of SJTU for AMS-02 Yang Yupu AMS JSC, Jan 8-12, 2007.
I Pag 1 Microchiller 2. I Pag 2 I Pag 3 Information on the display.
Industrial Automation T Rajendran. Industrial Automation  Control Systems  Process Control  Industrial Control  Computer Integrated Manufacturing.
Interface Connections
Experts in Chem-Feed and Water Treatment An Overview of Possibilities Dulcometer Disinfection Controller ( DDC )
Tier 1 : Who is Yokogawa Industrial Automation?
Yokogawa Field Solutions
Yokogawa’s FIELDBUS solution
LDA Large Display for Analog Inputs. Agenda What is the LDA? Easy programming About the input Setpoint control Communication Other features Packaging.
Yokogawa Indonesia < Document Number> Copyright © 2004, Yokogawa Indonesia Products & Solutions.
Copyright © 2004 Yokogawa Indonesia Products & Solutions.
Yokogawa Indonesia < Document Number> Copyright © 2004, Yokogawa Indonesia Rollout Workshop Yokogawa Field Instrumentation Solutions March 01, 2003.
Yokogawa Electric Corporation FFFieldDevicePortfolioMasterApril2006 © Yokogawa Electric Corporation FOUNDATION™ Fieldbus Field Device Portfolio Today's.
Industrial Electronic Department
CBC BODY COMPUTERS CHAPTER 12. CBC OBJECTIVES H ANALOG AND DIGITAL VOLTAGE SIGNALS H COMPUTER COMMUNICATION H COMPUTER MEMORY H INPUTS H OUTPUTS H MULTIPLEXING.
Chapter 2 Basic Principle of PLC PLC Configuration &Function   Basic Configuration  CPU  Memory  Programming Interface  Communication.
CENTUM CS 3000 R3.04 PROFIBUS Interface Module
ELECTRO – PROPORTIONAL VALVES
Yokogawa Electric Corporation FBF Copyright © Yokogawa Electric Corporation April, 2007 Interoperability Test and Yokogawa Devices April, 2007.
Device Capabilities Yokogawa vs. Emerson
Yokogawa Electric Corporation ISD-MASP-S03018 Rev.2 Copyright © Yokogawa Electric Corporation October,2003 Solution Marketing Group International Business.
Copyright © Yokogawa Electric Corporation FDT Technology “one tool for all” September 26, 2006 Yokogawa Electric Corporation.
Yokogawa Electric Corporation Copyright © Yokogawa Electric Corporation April 24, 2002 Valve Management Software ValveNavi for Yokogawa YVP.
Industrial Electronic Department Copyright of German Malaysian Institute. All rights reserved.
Interactively change status, schedules, setpoints and strategies
GIF++ Control System (GCS) Gilles MAIRE PH-DT-DI1.
目录 8 in 1 Sensor ◆ 8 in 1 Sensor Unique Features ● Built in PIR motion sensor and light intensity sensor ● Built in 2 Dry Input Ports ● Built in 32 Logics.
Standards Certification Education & Training Publishing Conferences & Exhibits Automation Connections ISA EXPO 2006.
The complete flow monitoring solution Measure – Display – Switch – Transmit.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
Standards Certification Education & Training Publishing Conferences & Exhibits Automation Connections ISA EXPO 2006.
LOGO Electronic Volume Converter TZ, PTZ ”Flougas-T”
APMP TC Fluid Flow Initiative Project Traceability Scheme Study for LPG Metering Final Report at APMP 2012 TCFF Meeting Chun-Min Su CMS/ITRI, Chinese Taipei.
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Kessler-Ellis Products
FLoor Heating Controller
UNICOS: UNified Industrial COntrol System CPC (Continuous Process Control) Basic course SESSION 3: PLC basics UCPC 6 UNICOS-Continuous Process Control.
PLC Terminology and Application
FLoor Heating Controller
RF Matching Network Description
INTRODUCTION TO ELECTRONIC INSTRUMENTATION
Measuring Current Learning Objective: Use an ammeter with care
Universal I/O Concentrator UK/S 32.2
MicroLogix Packaged Controllers
Control Loops: Primary Sensors, Transmitters, and Transducers - Agenda
Chapter 8. Multiplexing Frequency-Division Multiplexing
easYgen-3000XT Series Training
Day 2 Training - Sales Foundation Fieldbus
Detailed information FOR INTERNAL USE ONLY! CUBE20.
Presentation transcript:

Yokogawa Electric Corporation Copyright © Yokogawa Electric Corporation Device Capabilities Yokogawa vs. Honeywell (incl. Flowserve positioner) May 16, 2006

Copyright © Yokogawa Electric Corporation 2 Proprietary info goes here… Current Consumptions YokogawaHoneywell Pressure, d/p transmitter EJX 15 mA max. (+ 9 mA SDL*) ST mA max. EJA 16.5 mA max. (+ 24 mA SDL*) Temperature transmitter YTA16.5 mA max.STT35F22 mA max. YTA8011 mA max.STT40F22 mA max. Temp. multiplexerF2D0-TI-Ex8.FF (P+F)26 mA max.--- Vortex flowmeter DYF 11 mA max. (+ 24 mA SDL*) --- YEWFLO Style E19 mA max. Magnetic flowmeterADMAG AXF15 mA max. (4-wire)--- Coriolis flowmeterROTAMASS15 mA max.--- PositionerYVP/YPK 17 mA max. (+ 24 mA SDL*) LX1400 (Flowserve) 25 mA max. pH/ORP transmitterPH20222 mA max.--- Conductivity transmitter SC202 ISC mA max.--- Dissolved O2 meterDO20222 mA max.--- Averaging converter for O2AV550G15 mA max.--- Fieldbus displayBA488CF (BEKA)10 mA max.--- Paperless recorder DAQSTATION MobileCorder 16.5 mA max.--- *The value shows the additional current consumption which is needed at software download (SDL).

Copyright © Yokogawa Electric Corporation 3 Proprietary info goes here… Maximum Response Delay x Slot Time YokogawaHoneywell Pressure, d/p transmitter EJX 12ST EJA Temperature transmitter YTA12STT35F50 YTA8020STT40F50 Temp. multiplexer (P+F)F2D0-TI-Ex8.FF (P+F) Vortex flowmeter DYF YEWFLO Style E Magnetic flowmeterADMAG AXF Coriolis flowmeterROTAMASS Positioner YVP 12LX1400 (Flowserve)50 YPK pH/ORP transmitterPH Conductivity transmitterSC202/ISC Dissolved O2 meterDO Averaging converter for O2AV550G12--- Fieldbus displayBA488CF (BEKA) Paperless recorder DAQSTATION MobileCorder 12---

Copyright © Yokogawa Electric Corporation 4 Proprietary info goes here… Block Execution Time YokogawaHoneywell Pressure, d/p transmitter EJX AI: 30 ms max. PID: 45 ms max. SC: 30 ms max. IT: 30 ms max. IS: 30 ms max. AR: 30 ms max ST3000 AI: 23 ms PID: 90 ms EJA AI: 100ms max. PID: 160ms max. Temperature transmitter YTA AI: 50 ms max. DI: 30 ms max. PID: 100 ms max. STT35F AI: 23 ms PID: 90 ms YTA80 AI: 50 ms max. PID: 70 ms max. STT40F AI: 23 ms Temp. multiplexer F2D0-TI-Ex8.FF (P+F) AI: 40 ms max. MAI: 40 ms Max. --- Vortex flowmeter DYF AI: 29 ms max. PID: 44 ms max. DI: 25 ms max. --- YEWFLO Style E AI: 100 ms max. PID: 160 ms max. Magnetic flowmeterADMAG AXF AI: 30 ms max. PID: 50 ms max. DI: 25 ms max. IT: 30 ms max. AR: 30 ms max. --- Coriolis flowmeterROTAMASS AI: 30 ms max. IT: 30 ms max. PID: 50 ms max. ---

Copyright © Yokogawa Electric Corporation 5 Proprietary info goes here… Block Execution Time YokogawaHoneywell Positioner YVP110 AO: 95ms max. PID: 120ms max. DI: 40ms max. OS: 95ms max. LX1400 (Flowserve) AO: 50ms PID: 90ms YPK110 AO: 105ms max. PID: 120ms max. DI: 40ms max. OS: 95ms max. pH/ORP transmitterPH202AI: 100ms max. --- Conductivity transmitter SC202 ISC202 AI: 100ms max. --- Dissolved O2 meterDO202 AI: 100ms max. --- Averaging converter for O2 AV550G AI: 29 ms max. DI: 25 ms max. MAI: 29 ms max. MAO: 35 ms max. --- Fieldbus displayBA488CF (BEKA)MAO: 50 ms max.--- Paperless recorder DAQSTATION MobileCorder AI: 30ms max. MAI: 30ms max. MAO: 30ms max. ---

Copyright © Yokogawa Electric Corporation 6 Proprietary info goes here… Function Block and Device Class YokogawaHoneywell ModelFunction blockDevice classModelFunction blockDevice class Pressure, d/p transmitter EJX AIx3, PIDx1, ISx1, SCx1, ARx1, ITx1 LINK MASTER ST3000AIx1, PIDx1 LINK MASTER EJAAIx2, PIDx1 LINK MASTER Temperature transmitter YTA AIx4, DIx4, PIDx2 LINK MASTER STT35FAIx1, PIDx1 LINK MASTER YTA80AIx2, PIDx1STT40FAIx2 Temp. multiplexer F2D0-TI-Ex8.FF (P+F) AIx8, MAIx1 LINK MASTER --- Vortex flowmeter DYF AIx2, DIx2, PIDx1 LINK MASTER --- YEWFLO Style E AIx1, PIDx1 LINK MASTER Magnetic flowmeter ADMAG AXF AIx1, PIDx1, DIx2, ITx2, ARx1 LINK MASTER --- Coriolis flowmeter ROTAMASS AIx6, PIDx1, ITx2, LINK MASTER ---

Copyright © Yokogawa Electric Corporation 7 Proprietary info goes here… Function Block and Device Class YokogawaHoneywell ModelFunction blockDevice classModelFunction blockDevice class PositionerYVP/YPK AOx1, DIx2, PIDx1, OSx1 LINK MASTER LX1400 (Flowserve) AOx1, PIDx1 LINK MASTER pH/ORP transmitter PH202AIx3BASIC--- Conductivity transmitter SC202 ISC202 AIx3BASIC--- Dissolved O2 meter DO202AIx3BASIC--- Averaging converter for O2 AV550G AIx3, DIx2 MAIx1, MAOx1 LINK MASTER --- Fieldbus display BA488CF (BEKA)MAOx1BASIC--- Paperless recorder DAQSTATION MobileCorder AIx8, MAIx1, MAOx1 LINK MASTER ---

Copyright © Yokogawa Electric Corporation 8 Proprietary info goes here… Channels for I/O EJXPressure Static pressure (H) Static pressure (L) Capsul temp. Amplifier temp. --- EJAPressure Static pressure --- YTA Sensor1 temp. Sensor2 temp. Terminal temp. Diff. temp. Average temp. Back up temp. Temp. limit sw. 1 Temp. limit sw. 2 Temp. limit sw. 3 Temp. limit sw. 4 YTA80 Primary Value Sensor 1 Value Sensor 2 Value Internal Temp. F2D0-TI-Ex8.FF Sensor 1 for AI Sensor 2 for AI Sensor 3 for AI Sensor 4 for AI Sensor 5 for AI Sensor 6 for AI Sensor 7 for AI Sensor 8 for AI Sensor 1- 8 for MAI Body Temp. for AI DYFFlowrateTemp.Limit sw. --- YEWFLO Style EFlowrate--- ADMAG AXF FlowrateLimit Sw. 1Limit Sw. 2Switch 1Switch ROTAMASSMass Flow Volume Flow DensityTemp. Concent- ration Net Flow--- YVPPosition setpoint, readback High limit sw. Low limit sw. --- YPK PH202pHTemp.ORP--- SC202 ISC202 Conduc- tivity Temp. 2 nd Conduc- tivity Concen- tration --- DO202 Dissolved O2 Temp. % Saturation Cell current --- AV550G Average AAverage BAverage C Alarm Switch Error Switch Input for MAI Output for MAO --- BA488CF Output channel of MAO --- DAQSTATION MobileCorder Input for AI Input for MAI Output for MAO

Copyright © Yokogawa Electric Corporation 9 Proprietary info goes here… Channels for I/O ST3000Sensor Pressure Polynomial Equation --- STF35F Sensor Temperature --- STF40F Sensor1 Temperature Sensor2 Temperature --- LX1400 (Flowserve) Final Value Commanded to the Valve ---