Phoenix Convention Center Phoenix, Arizona Targeted E4 Re-Tuning at GSA Facilities Integrated Energy Low/No Cost Solutions through Building Automation.

Slides:



Advertisements
Similar presentations
Sustainable School Design Creating Healthy, High Performance School Facilities Presented by Stephen M. Koontz, Energy Services Leader, Tampa Bay Trane.
Advertisements

Improve Facility Operation through Commissioning-A Case Study Mingsheng Liu, Ph.D., P. E. University of Nebraska.
Intro to Enersol What is Retro-commissioning? Define Benefits of Retro-commissioning Define Retro-commissioning Process Discuss Retro-commissioning Findings.
HEALTHCARE BUILDING AUTOMATION
Tom Johanson – DNV KEMA Senior Engineer Building Automation Systems.
Objectives Control Terminology Types of controllers –Differences Controls in the real world –Problems –Response time vs. stability.
University of Iowa Indoor Practice Facility Outside-the-box HVAC Lincoln Pearce, PE – KJWW Engineering David Hahn – University of Iowa Chilled Water Plant.
Smart Devices. Smart Buildings. Smart Business The Potential for DCx Technology Enabled HVAC Operation Scot Duncan, P.E.
T OPPORTUNITIES FOR ENERGY EFFICIENCY AT TRIBAL GAMING FACILITIES.
MENG 547 LECTURE 3 By Dr. O Phillips Agboola. C OMMERCIAL & INDUSTRIAL BUILDING ENERGY AUDIT Why do we audit Commercial/Industrial buildings Important.
Energy Efficient Operations Presentation to ASHRAE Energy Expo October 2, 2013 Center for Energy and Environment.
ENERGY EFFICIENCY FOR END-USERS.  CSU Chancellors office coordinates the efforts to accomplish the goals established by Assembly Bill 32 for green house.
Technical And Financial Benefits Of Retro-Commissioning Initiatives Society of American Military Engineers Northern Virginia Post January 6, 2011 Presented.
Energy Management with the use of an Intelligent Building Management System.
44 th Annual Conference & Technical Exhibition By Thomas Hartman, P.E. The Hartman Company Georgetown, Texas Sustainable Chilled Water.
Deep retrofits: You get what you pay for Leslie Kramer, Stanford University and Jonathan Schoenfeld, kW Engineering June 17, 2014.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
 Install new air cooled high efficiency screw chiller (variable speed)  Install new fan coils with ECM motors and low temperature heating coils and proper.
Federal Data Center Consolidation Initiative Karen Petraska August 17, 2011.
Static Pressure Control Loop The purpose of the static pressure control loop is to maintain an optimal static pressure in the ductwork. The control loop.
Commissioning for Sustained Building Performance Building Performance Heifer Village Little Rock, AR 09/17/10 Retrocommissioning | RCx (Existing Building.
Auraria Higher Education Center Case Study John Ismert & Frank Ellis Auraria Higher Education Center Facilities Management.
You can achieve 100% Energy Saving WHEN YOU TURN OFF THE LIGHTS.
STAFFORD COUNTY PUBLIC SCHOOLS ENERGY MANAGEMENT PROGRAM 2009 UPDATE Bob Randall CEM,,BEP, CBCP Energy Manager Energy Manager.
Examples of Commissioning Cost Savings Commissioning for Sustained Building Performance September 29, 2011 Marriott Birmingham, AL.
DNV GL © 2014 SAFER, SMARTER, GREENER DNV GL © 2014 HVAC_3 Quality Maintenance 1 Research Plan.
Hawke’s Bay Refrigeration
Phoenix Convention Center Phoenix, Arizona HVAC Re-tuning at GSA and Army Reserve Facilities: A Low-Cost Path to Energy Efficiency and Cost Savings Integrated.
Leveraging an Energy Plan Managing Energy to Reduce Operating Cost and Improve Building Valuation.
April, 2002Energy Audits1 Heating Degree Days The difference between the base temperature (balance point) and the mean ambient temperature for the day.
Hot Climate Initiatives National Low-Income Energy Consortium Phoenix, Arizona June 16, 2005.
Foothill College & Space Science Center Bill Kelly Viron Energy Services (510) ext 13,
Mike Eardley, PE, LEED AP, CCP Director of Commissioning CannonDesign Brian Berg, Jr., PE, LEED AP, CSI Principal Berg Engineering Consultants, Ltd. April,
Phoenix Convention Center Phoenix, Arizona Keys to Energy Behavior Change Solution Showcase Retained Energy Savings: Putting It into Practice Mike Van.
Resource Conservation Program November 2003 Kelley Gonzales Resource Conservation Manager.
Phoenix Convention Center Phoenix, Arizona Solution Showcase GSA’s NDER Program: Doubling the Energy Savings from Financed Projects Kevin Vaughn Schneider.
Phoenix Convention Center Phoenix, Arizona M&V Contracting / Business Perspective Track 5: Project Financing Session 5: M&V: High- and Low-Level Perspectives.
Phoenix Convention Center Phoenix, Arizona FEMP Training Supports FBPTA and FMI.gov Institutional Change Federal Buildings Personnel Training Act: Resources.
Phoenix Convention Center Phoenix, Arizona Lessons Learned from ARRA Projects Solution ShowcaseLessions Learned from ARRA Projects Walter Tersch, LEED.
Phoenix Convention Center Phoenix, Arizona GSA’s Actions under the PPCC GSA’s Pipeline Session 1, Track 5Meeting the PPCC Sharon Conger Public Building.
Challenges of Localized Cooling Systems
Commissioning of New and Existing Buildings Alexander P. Boucher, P.E., CEM, LEED BD+C.
Phoenix Convention Center Phoenix, Arizona Integrative Design: Deep Energy Approach Track 6: Integrated Energy Session 5: Integration of the Energy Industry.
Phoenix Convention Center Phoenix, Arizona Facility Energy Audits Mike Gutowski Johnson Controls August 12, 2015 Agency Energy ManagerEnergy Audits: Implementing.
Evaluation of the RTF Standard Protocol Fan and Cooling Savings from Commercial-Sector Heat Pump Units Rooftop Unit Working Group (RTUG) August 20, 2012.
RTU Savings Research Project RTU Savings Research Project: Findings and Recommendations Regional Technical Forum February 3, 2009 Mark Cherniack Howard.
Whitman-Hanson Regional High School Energy Efficient Systems: HVAC All fans and pumps are VFD controlled with fully reactive controls Condensing gas-fired.
Lecture Objectives: Clarify issues related to eQUEST –for midterm project Learn more about various HVAC - economizer - heat recovery Discuss about the.
Using Technology to Manage Energy Bob Schoch-Director of Business Administration Tom Schneider-Supervisor of Operations.
Control Theory Control System Objectives  Establish a final condition  Provide safe operation  Eliminate the human element  Assure economical operation.
Energy Services Harsha Holalu Ramakrishna Energy Extension Specialist Department of Mechanical and Aerospace Engineering.
GRES Education. The goals of the GRES Education program are to: help school districts reduce energy use, conserve water, and minimize waste production.
Introduction to Energy Management. Week/Lesson 13 Control Strategies for Occupant Comfort.
Jesse A. Fisher Mechanical Option Spring 2005 Riverpark Corporate Center, Phase 1 Salt Lake City, Utah.
VRF Applications in PNW RTF RTUG Meeting October 26, 2011 Kevin Campbell Reid Hart, PE Technical Research Group.
Slide 1 B O N N E V I L L E P O W E R A D M I N I S T R A T I O N Performance Tested HVAC Presentation to the RTF January 5, 2010.
Prepared For: Prepared By: 100 Montgomery Street, Suite 600 San Francisco, CA Market Street San Francisco, CA The Benefits of Retrocommissioning.
Lack of dedicated building meter – Solution: Estimate square footage of Herberger in relation to total area serviced by meter – Estimate 12% of total.
GrocerSmart™ 4.0 RTF Approval of Software and Adherence to RTF Guidelines April 5, 2011.
Turning Energy Data into Operations Intelligence Presented to: FMA September 17, 2013.
AstraZeneca R&D Boston Waltham Energy Reduction Initiative 2016 Green Labs Symposium.
Energy Solutions for Business Owners Presented by: [Put your name here] Welcome to... Your Logo Here.
Frank Dick, PE Aaron Kraft Wastewater Engineer Project Manager
The Data Center Challenge
By: John D. Villani, P.E., LEED AP, QCxP, CEM, GBE
Story of No-Cost Energy Savings at Ohio Union
Industrial Assessment Center Database
HVAC Basics Arkan Arzesh HVAC – Heating, Ventilation, Air-conditioning.
Calibrated Energy Models: One New Change
Alabama Industrial Assessment Center
Presentation transcript:

Phoenix Convention Center Phoenix, Arizona Targeted E4 Re-Tuning at GSA Facilities Integrated Energy Low/No Cost Solutions through Building Automation System Control Technologies August 13, 2015 Nick Fernandez Pacific Northwest National Laboratory Linda Baschnagel, P.E. General Services Administration

Energy Exchange : Federal Sustainability for the Next Decade The Heartland Region (R6) began working with Pacific Northwest National Laboratory (PNNL) Phase I - Energy Efficiency Expert Evaluations (E4) E4 field audits provided training to identify low-cost and no- cost energy efficiency measures (EEMs) to GSA Staff and operation and maintenance (O&M) contractors outlining improvements to the operational efficiency of buildings. 8 R6 GSA Building (4.7 million SF) Classroom and field training for 110 GSA Staff and O&M contractors 160 recommendations (no-cost/low cost and small repairs) 2 Targeted E4: Project History

Energy Exchange : Federal Sustainability for the Next Decade In FY12, DOE funded an assessment to evaluate the impact of the 8 E4 audits. Results Average savings at the 8 buildings: 6.4% Only about 50% of the 160 recommendations implemented Field auditing to identify a list of measures was not totally effective – Staff did not make audit recommendations a priority – Limited experience by O&M with control systems to perform implementations – Implementation weighted towards easy changes like scheduling, but advanced control measures were left on the table. 3 Targeted E4: Project History

Energy Exchange : Federal Sustainability for the Next Decade Based on the results, the Heartland Region and PNNL revised the approach to achieve key EEM implementation Phase II – Targeted E4 Identify and implement control system measures. Train the O&M staff on the control measures and use of BAS Two site visits – Initial visit to identify and implement measures – Second visit to verify functionality of implemented measures – Ongoing remote assistance by tele-conference and remote access to BAS Nov Targeted E4 model was tested in 4 buildings – Results – Energy savings range: 9% - 18% – Simple Payback approximately 1 year 4 Targeted E4: Project History

Energy Exchange : Federal Sustainability for the Next Decade The Targeted E4 model was expanded to 5 additional buildings in FY13 and FY14. Two site visits were conducted over the 1 year assessment period for each building – Initial visit identified and implemented measures – Second visit scheduled during the opposite season Identify and implement additional measures not looked at before – Opportunity for additional on-job-training for staff – Continued remote assistance by tele-conference and remote access to BAS The Targeted E4 model has been adopted by the Heartland Region as a standard practice and will be completed on 15 buildings by the end of FY15. (7.3 million SF) 5 Targeted E4: Project History

Energy Exchange : Federal Sustainability for the Next Decade 6 Targeted E4: Project History GSA Region 6: 15 Targeted E4 Buildings

Energy Exchange : Federal Sustainability for the Next Decade Cooperation and engagement of the building staff and O&M is critical Ensure the staff/O&M understand and are comfortable with the implementations and know how make adjustments if necessary Training is more effective with hands-on experience Proper scheduling of site visit is essential 7 Keys to Success

Energy Exchange : Federal Sustainability for the Next Decade Regional Project Manager to assist with logistics before, during and after the site visits is a requirement for success Coordination of other work ongoing in the building Leverage staff ideas for additional opportunities Onsite support and remote monitoring are key Continually monitoring of building performance a must 8 Keys to Success

Energy Exchange : Federal Sustainability for the Next Decade Two site visits (minimum) – Site visits during heating and cooling season will result in more complete analysis To date, Region 6 experience indicates the Monitoring and Re- tuning Plans included in each report are not being used for follow-up by the O&M – R6 has engaged spot monitoring building performance with the assistance of a contract BAS Specialist and the planned hiring of a new Building Systems Analyst FTE 9 Further Improvements

Energy Exchange : Federal Sustainability for the Next Decade Targeted E4 re-tuning helps to quickly identify, and then quickly implement no-cost/low-cost building retuning measures that produce immediate/measurable energy performance improvements Targeted E4 produced significantly better results than E4 approach All buildings improved energy performance Targeted E4s are sustainable and are showing an impact on the improved regional energy performance Targeted E4 re-tuning is a transferable, repeatable model The R6 Regional Energy Team shared the Targeted E4 approach and resulting successes with GSA Central Office and other Regions. The Targeted E4 model was expanded throughout GSA in FY14. PNNL is currently offering the model to other GSA Regions and federal agencies. 10 Results from Targeted E4 Implementation

Energy Exchange : Federal Sustainability for the Next Decade 11 Targeted E4: Project History FY : GSA Region 6 funded effort: 9 buildings total (Red) FY2014: GSA Central Office funded effort: 18 buildings total (Blue) FY2015: GSA Central Office funded effort: 17 buildings total (Green)

Energy Exchange : Federal Sustainability for the Next Decade 12 Energy Saving Control Measures 341 total measures (59 unique measures) recommended at 39 buildings AHU and OAHU Air Delivery Static Pressure Reset Supply Air Temperature Reset Economizer Strategy Preheat Coil Strategy Outdoor AHU Discharge Temperature Ventilation (minimum) air flow rate

Energy Exchange : Federal Sustainability for the Next Decade total measures (59 unique measures) recommended at 39 buildings HVAC Scheduling AHU Schedule Adjustment Optimal Start Optimal Stop Exhaust Fan Schedule /Coordination Pump Staging and Scheduling Energy Saving Control Measures

Energy Exchange : Federal Sustainability for the Next Decade total measures (59 unique measures) recommended at 39 buildings Zone Equip., T-stat, and Air Distribution Server Room Equipment Coordination Thermostat Set points and Dead-bands VAV box mode configuration Minimum VAV airflow fraction Night Setback Energy Saving Control Measures

Energy Exchange : Federal Sustainability for the Next Decade total measures (59 unique measures) recommended at 39 buildings Ventilation, Infiltration and Heat Recovery OAHU coil and wheel control Minimum outdoor-air damper scheduling Ventilation (minimum) air flow rate Demand Control Ventilation Building Pressurization Control Energy Saving Control Measures

Energy Exchange : Federal Sustainability for the Next Decade total measures (59 unique measures) recommended at 39 buildings Chilled Water Plant Control Chilled Water Temperature Reset Chilled Water Differential Pressure Reset Condenser Water Temperature Reset Chiller and coil lockouts Chiller Staging Energy Saving Control Measures

Energy Exchange : Federal Sustainability for the Next Decade total measures (59 unique measures) recommended at 39 buildings Heating Plant Control Hot Water Differential Pressure Reset Hot Water Temperature Reset Boiler Lockouts Isolation Valves Energy Saving Control Measures

Energy Exchange : Federal Sustainability for the Next Decade total measures (59 unique measures) recommended at 39 buildings Lighting Schedules and De-lamping Other Domestic Hot Water Faulty Valves Snowmelt Sensor Calibration Pneumatic Compressor Energy Saving Control Measures

Energy Exchange : Federal Sustainability for the Next Decade 39 buildings analyzed Average building: 14.4% total predicted savings(all measures) Engineering estimates, TMY analysis, building energy models (BEMs) 19 Where are the Opportunities? Average Predicted Savings

Energy Exchange : Federal Sustainability for the Next Decade 27 buildings analyzed Estimates based on predicted savings by measure, verification of measure implementation, and monitoring of 12-month energy savings. 20 Most Impactful Measures: Estimated Share of Total Achieved Savings

Energy Exchange : Federal Sustainability for the Next Decade 21 Quantifying Energy Savings Using Interval metered-data whenever possible (most cases), monthly utility data when not possible Data “cleaned” to remove meter outages and unreliable data. Post-site visit data at each meter interval matched to average of pre-site visit data at same hour of day, same day type (weekday/weekend) and similar OA temperature Verification that savings patterns in interval meter data match savings in monthly utility data

Energy Exchange : Federal Sustainability for the Next Decade Verified Energy Savings 26 Buildings Median Savings: 12.7% (9.7% electricity, 17.7% gas/steam) Wide spectrum of heating meter savings Electricity savings very commonly in 5-10% range. 22

Energy Exchange : Federal Sustainability for the Next Decade Verified Energy Cost Savings Median Savings: $0.127 per square foot per year 2/3 of buildings saved between 5 and 15 cents per square foot per year 23

Energy Exchange : Federal Sustainability for the Next Decade Persistence of Savings Four Buildings suitable for long-term analysis In all 4 buildings, savings has not deviated substantially after year 1. 24

Energy Exchange : Federal Sustainability for the Next Decade Persistence of Savings PNNL Reports Savings based on an analysis of “ION” system sub- metered data using a 6-month monitoring period Validating with utility monthly data, corrected for weather, savings has increased slightly (on average) each year, relative to original ION-reported savings. 25

Energy Exchange : Federal Sustainability for the Next Decade Factors that Promote Cost Effective Re-Tuning Building size matters! We have consistently achieved simple payback periods under 2 years when buildings are over 100,000 sf. 26 Minimum expected payback time?

Energy Exchange : Federal Sustainability for the Next Decade Factors that Promote Cost Effective Re-Tuning Initial Energy Efficiency of building (using Energy Star score) Energy Star scores a building relative to similar buildings in similar climate. 50 is average. 0 is worst building in cohort, 100 is best building in cohort – Not a strong correlation BUT… – For Energy Star scores 80 or below, 6/6 achieved >10% savings – For Energy Star scores above 80, 8/17 achieved <10% savings – Yet 3 buildings with initial scores over 90 saved between 18-25% 27

Energy Exchange : Federal Sustainability for the Next Decade Factors that Promote Cost Effective Re-Tuning Factors that we observe promote success – Presence of variable speed drives, especially on fans – Advanced controls (resets, Optimal Start, etc.) NOT already in place – Direct Digital Control (DDC) as opposed to pneumatic systems – Modern, updated Building Automation System – Dedicated Outdoor Air Systems with energy recovery (commonly lack advanced controls for optimization) – Strong leaders within region who advocate for energy efficiency and/or have mechanical and controls expertise Region 6 (very strong support): 72/96 measures implemented (75%) Other regions visited: 81/125 measures implemented (65%) – Building property managers and O&M staff willing to experiment! 28

Phoenix Convention Center Phoenix, Arizona THANK YOU!! -- QUESTIONS? Nick Fernandez Linda Baschnagel