Helmut Schink, Vice Chair of SG 15

Slides:



Advertisements
Similar presentations
© DIAMOND Headquarters / F-3000 r & rs / / 1 WERE WELL CONNECTED F-3000 r & F-3000 rs connectors.
Advertisements

What’s New In Service Provider Networks?
Excellence in Connectivity Solutions 1 Fiber Optics Division.
Industrial Segment Alternative Power Generation
Seminar Report On Digital Power Line Carrier Communication
GSC: Standardization Advancing Global Communications Home Networking in ITU-T An overview of the Home Networking studies in ITU-T and of the Joint Co-ordination.
Hanoi Workshop Conclusions Study Group 6 Outside Plant for the Access Network Workshop Hanoi, 24 November 2004 SESSION 1 IMPLEMENTATION OF OUTSIDE PLANT.
ICT Infrastructures and Climate Change Chaesub Lee Chairman of ITU-T SG 13 (ETRI, Korea)
Workshop on Telecommunications for Disaster Relief, February 2003, Geneva Dag Nielsen & Catherine Mulligan Ericsson Response WLAN in Disaster and.
International Telecommunication Union Seminar on Impact of Electromagnetic Field Emissions Kampala, Uganda, 3-5 September 2003 ITU-T Study Group 5 Publications.
Evolution of Optical Fibre Types and Cables
Summary of Results Study Period ITU-T Study Group 15 Optical and other transport network infrastructures Yoichi Maeda.
Steve Joiner, Technical Committee Chair John McDonough, Member OIF Board of Directors Optical Internetworking Forum.
Geneva, Switzerland, 22 September 2012 FTTx in Japan: Past, Present, and Prospects for the Future Ken-Ichi Suzuki, NTT Access Network Service Systems Laboratories,
FTTH in Portugal- Past, Present and the Future
ITU-T SG 15 Work on Interoperability and Conformance Helmut Schink, Vice Chair of SG 15 Nokia Siemens Networks Regional ITU Consultation on Conformance.
Committed to connecting the world Bridging The Standardization Gap for Africa Africa Regional Preparatory Meeting for WTSA-12 Bridging the standardization.
Committed to connecting the world Bridging The Standardization Gap for RCC ITU Regional Forum 2012 Bridging the standardization gap for RCC countries Tashkent,
Summary of Results Study Period ITU-T Study Group 6 Outside Plant and related indoor installation Francesco Montalti.
Overview of SG5 and SG5RG for Africa activities
International Telecommunication Union ITU-T Seminar – Lisbon, 25 June 2002 ITU-T Activities Greg Jones ITU Telecommunication Standardization Sector (ITU-T)
International Telecommunication Union Technical Specification for Sustainability John Smiciklas Director, Corporate Responsibility Programs Research In.
Pune, India, 13 – 15 December 2010 ITU-T Kaleidoscope 2010 Beyond the Internet? - Innovations for future networks and services (Verdana 24) Name of presenter.
ARCHITECTS OF AN INTERNET WORLD 14/03/ Broadband Passive Optical Networks March 14, 2002 Tim Gyselings, Alcatel March 14,
Semiconductor Optical Amplifiers in Avionics C Michie, W Johnstone, I Andonovic, E Murphy, H White, A Kelly.
1 © 1999, Cisco Systems, Inc. IP over DWDM NANOG May 24, 1999 Larry McAdams
10/100Base-TX to 100Base-FX Redundant Media Converter
A Wireless Local Area Network (WLAN) is a network that interconnects devices using radio waves. Wireless networking technologies allow devices to communicate.
Water Utility Business Applications. 2 Agenda Industry overview and trends Our application visionary solution Business values Wireless network components.
1 Understanding which market scenarios are best served by active Ethernet point-to-point (EP2P) and which are best served by point-to-multipoint PON architectures.
Outside Plant Network Topologies October Emerson Electric Co; Proprietary Information Table of Contents Fiber to the NodeFTTN Network with Non-Hardened.
Chapter 7 Transmission Media
Confidential and proprietary materials for authorized Verizon personnel and outside agencies only. Use, disclosure or distribution of this material is.
OPTICAL FIBRE CABLE.
1. The ITU Radiocommunication Sector (ITU-R) will remain the unique and universal convergence and regulatory centre for worldwide radiocommunication matters.
ITU-T Study Group 5 “Environment and Climate Change”
Committed to connecting the world Overview of ITU-T Study Group 5 “Environment and Climate Change” Ahmed ZEDDAM France Telecom Orange Chairman, ITU-T Study.
Maputo, Mozambique, April 2014 Standardization activities on optical access transport systems in ITU-T SG15 Hiroshi OTA Study Group Engineer, ITU/TSB.
Maputo, Mozambique, April 2014 ITU Activities on Bridging the Standardization Gap (BSG) Hiroshi OTA Study Group Engineer, ITU/TSB
© DIAMOND SA / X-BEAM / / 1 X-BEAM Connector Up to 4 channels SM and MM optical connections based on Expanded Beam technology.
Committed to connecting the world Overview of ITU-T Study Group 5 “Environment and Climate Change” Cristina Bueti Adviser, ITU-T Study Group 5.
Summary of Results Study Period ITU-T Study Group 15 Optical transport networks and access network infrastructures Yoichi Maeda.
Bottoms Up Factoring. Start with the X-box 3-9 Product Sum
Innovative solutions in rights of way to support broadband development Antti Kohtala Ministry of Transport and Communications Finland Digital Agenda Assembly,
Standardization activities in ITU-T SG15 related to energy efficiency Hiroshi OTA ITU/TSB Geneva, 11 July 2014.
ITU Workshop on “Quality of Service and Quality of Experience of Multimedia Services in Emerging Networks” (Istanbul, Turkey, 9-11 February 2015) Standardization.
Problems and solutions in optical network plants in Hungary Torino, March 1998 Technological problems and solutions in optical network plants in.
Efficient flexibility in room management with SAUTER EY-modulo.
The Fiber Optic Association is the professional society of fiber optics. It was founded in 1995 by a dozen fiber optic professionals who felt fiber optics.
Future Fiber Architectures John A. Jay Manager, Worldwide Applications Engineering 19 November 2009.
Overview of ITU-T Study Group 5 “Environment and Climate Change” Cristina Bueti, Adviser, ITU.
Efficient broadband deployment & multi-service implementation European home networking platform Dominique Roche (ATTM chairman) DOCUMENT #:GSC13-GTSC6-19.
Service d’Électromagnétisme et de Télécommunications 1 1 Attenuation in optical fibres 5 ème Electricité - Télécommunications II Marc Wuilpart Réseaux.
ANCIT WORKSHOP Torino March Access Network in EURESCOM Projects, and the P614 Project Umberto Ferrero CSELT (P614 Project Leader) Participants.
Fiber Optics Communications Lecture 11. Signal Degradation In Optical Fibers We will look at Loss and attenuation mechanism Distortion of optical signals.
FIBER PROPERTIES Transmission characteristics of a fiber depends on two important phenomena Attenuation Dispersion Attenuation or transmission loss Much.
ISDN ADSL FTTx, VDSL2, ADSL2plus Enhanced Copper Hybrid Fibre/Copper Pure Fibre Speed Comparison Voice band Modem FTTH.
Graduate Engineer Lunch & Learn Edmonton, 2011 The Evolution of FTTH Technology Jonathan Hnit, P.Eng August 25 th, 2011.
Exchange & Cabinet Tour 19 th November Traditional fixed telephony is based around a central office or exchange that serves customers with an.
ANSI/TIA-568-C Generic Telecommunications Cabling APPROVED: FEBRUARY 2, 2009 This template can be used as a starter file for presenting training.
Geneva, Switzerland, 13 July 2013 Welcome Stephen J. Trowbridge, Chairman, ITU-T Study Group 15 Joint IEEE-SA and ITU Workshop on Ethernet.
ANCIT WORKSHOP Torino, March ANCIT WORKSHOP Torino, March 1998.
Retractable Techniques in fibre optic infrastructures Öner Özemre – Telecom Sales Regional Manager TLC 19th – 20th April 2012.
Outside Plant Fiber Optics Outside Plant Fiber Optics Module 5 Fiber to the Home.
Fiber To The Home (FTTH)
Your Optical Fiber Solutions Partner ® Basics of FTTH Design Jeff Bush and Geoff Thumma All Rights Reserved, Copyright © OFS Fitel LLC 2015.
ITU-T STUDY GROUP 15 Networks, Technologies and Infrastructures for Transport, Access and Home Summary of Results Study Period Dr. Stephen J.
Peter Wery Chairman ITU-T Study Group 15 Nortel Networks
Stephen J. Trowbridge, Chairman, ITU-T Study Group 15
ITU-T Study Group 6 Outside Plant
Presentation transcript:

Helmut Schink, Vice Chair of SG 15 Helmut.schink@nsn.com ITU-T Kaleidoscope 2010 Beyond the Internet? - Innovations for future networks and services Trends in Transport Standards Helmut Schink, Vice Chair of SG 15 Helmut.schink@nsn.com Pune, India, 13 – 15 December 2010

ITU-T Structure WTSA SG SG Working Party WP WP WP Focus Group Q Q Q Q Workshops, Seminars, Symposia… WTSA World Telecommunication Standardization Assembly Telecommunication Standardization Advisory Group IPR Ad hoc SG Study Group SG Working Party WP WP WP Focus Group Q Q Questions: Develop Recommendations Q Q Q Q Pune, India, 13 – 15 December 2010 2

Study Group 15: Overview General area of study is on “Optical transport networks and access network infrastructures” SG 15 is the focal point in ITU T for the development of standards on optical and other transport network infrastructures, systems, equipment, optical fibres, and the corresponding control plane technologies to enable the evolution toward intelligent transport networks. This encompasses the development of related standards for the customer premises, access, metropolitan and long haul sections of communication networks. Pune, India, 13 – 15 December 2010 3

Study Group 15: Overview Home / Access / Regional Long Haul Optical Metallic Access Terrestrial & Submarine Pune, India, 13 – 15 December 2010

Projects and Opportunities SG 15 Major projects Lead SG on access network transport Lead SG on optical technology Lead SG on optical transport networks New opportunities Home networking Energy management Power saving Home and commercial building automation transceivers New customer premises cabling Interoperability testing (e.g. with FTTH Council Europe) Packet Transport Device Management Lisbon, Portugal, 24-25 February 2010 Pune, India, 13 – 15 December 2010 5

SG 15 Management Chair: Yoichi Maeda, TTC Vice-Chairs, WP Chairs: Sadegh Abbasi Shahkooh, Iran Baker Baker, Syria Júlio Cesar Fonseca, Brasil Viktor Katok, Ukraine Francesco Montalti, WP 2, Telecom Italia Helmut Schink, Nokia Siemens Networks Tom Starr, WP 1, AT&T Steve Trowbridge, WP 3, Alcatel Lucent Shaohua Yu, China Counsellor: Greg Jones Pune, India, 13 – 15 December 2010

Major front lines Outside plant techniques for easy, environmentally friendly installation Fibres: rubustness and low water peak Higher speed and lower power consumption in home network DSL copper access Fiber access Common OAM mechanisms for MPLS Beyond 100G long haul optics Syncronisation e.g. for backhaul Pune, India, 13 – 15 December 2010

L. 83 “Low impact minitrench installation techniques” Installation of mini ducts structures inside a small dimension trench: width less than 5 cm and depth in the range 20-30 cm (compared with 10x30 cm of the conventional one) Possibility of installing up to 3 linear arrays of 5 mini ducts  10/14 mm directly buried Use of low environmental impact trenching machines Pune, India, 13 – 15 December 2010

Solutions for installation of ducts and cables in an occupied infrastructures Outfitting of existing ducts (telcos, street lighting, power..) with10/12 mm mini ducts and use of completely dielectric minicables Separation of the telecommunication access points with the use of reduced dimensions manholes 9 Pune, India, 13 – 15 December 2010 9

Q7/15 Work in Progress L.distr “Customer and distribution boxes and terminals” L.drop “Pre-terminated fibre drop cables & hardened connectors” L.modc “Environmental protection of optical devices and optical connectivity in outside plant conditions” L.oxcon “Outdoor optical cross connect cabinets ? Optimization of space Unbundling? Need of new Recommendation on field mountable connector technologies Pune, India, 13 – 15 December 2010

ITU-T documents give guidance on how to use the available spectrum Pune, India, 13 – 15 December 2010 11

Fiber Spectrum 10G-PON GPON (D)WDM PON Attenuation (dB/km) US US DS V Third window “1500-nm” 600 0.1 l (nm) 0.2 0.5 1.0 2.0 5.0 10 Attenuation (dB/km) 800 1000 1200 1400 1600 1800 First window “850-nm” Second window “1300-nm” Water peak Absorption Rayleigh Scattering 1270nm 1310nm 1490nm 1580nm 1550nm US US DS V DS Standard fiber AllWave® Fiber 10G-PON GPON (D)WDM PON Pune, India, 13 – 15 December 2010

Specified loss in dB for 1 turn at 1550 nm for radius: G. 657 “Bending loss insensitive single-mode fibres” G.657 A (G.652 compliant) A1 fibre 10 mm bending radius A2 fibre 7.5 mm bending radius G.657 B (not G.652 compliant) B2 fibre 7.5 mm bending radius B3 fibre 5 mm bending radius Following issues are being addressed as the future study points: - possibility of A3 fibre - splicing to G.652 fibre (level of compliance) - wavelength dependence of the transmission characteristics Specified loss in dB for 1 turn at 1550 nm for radius: Bending Radius 10 mm 7.5 mm 5 mm G. 657A1 <0.75 - G. 657A2 / B2 <0.1 <0.5 G. 657B3 <0.03 <0.08 <0.15 G.652 G.657 A1 G.657 A2 / B2 G.657 B3 Pune, India, 13 – 15 December 2010

Available Fiber Access Technologies Cabinet / Basement 10/100/1000bT 1 – 10G Ethernet Switch A) Direct Fiber (Point to Point) Reach: ~20Km Future proof architecture Protocol independent Completely passive ODN Follows established telco wiring practice High CO/LO Fiber Management cost Un-economical for countrywide FTTH B) AON (Active Optical Network) Reach: up to 40Km, (typ. ~7-15Km) Easy BW upgrades Flexible user & line rate deployment Simple deployment Shared Bandwidth Requires active equipment Increases OSP costs Increased OpEx 2.5G DS / 1.25G US Passive Splitter Athermal DWDM Filter C) G-PON G.984 Reach: ~20Km Simplified Fiber management Low cost passive OSP (no PSU, MNS) Low power consumption Low OpEx Video Broadcast (DS) Bandwidth sharing in US and DS ONT must filter rogue channels Security (MBH port shared with FTTH subscriber?) Splitter attenuation limits tree size D) WDM-PON Reach: ~20Km Passive ODN, symmetric BW Independent Lambda per subscriber Protocol Independent Reach amplification possible Reduced OSP costs, single fiber Security per line Easy BW upgrades Filters complicate OSP design Pune, India, 13 – 15 December 2010

Other/future Fiber Access Technologies E) UD-WDM Reach: up to 100Km Passive OSP Virtual Point to Point architecture Lambda per subscriber / service Colourless design, tunable ONT High split (up to 1:1000) Any packet transport format Low latency and delay Redundancy options Lambda per subscriber Passive Splitter Filter (Optional) 10G DS / 2.5G US Passive Splitter F) 10G-PON G.987 Reach: ~60Km Passive OSP Migration from G-PON Split 1:64 / 1:128 Low power Redundancy options G) CWDM+TDM-PON Reach: up to 60Km Strong service separation Reduced fiber count, CO consolidation possible CWDM filter in ODN Pune, India, 13 – 15 December 2010

Vectored VDSL2 enables up to 100 Mb/s Far-end crosstalk (FEXT) greatly reduces VDSL2 performance. Near-end crosstalk is not problem since VDSL2 uses different frequency band for upstream and downstream. DSLAM FEXT A vectored system sends “pilot” signals to learn the crosstalk coupling between all the lines in the cable Each transmitter “precodes” its signal to compensate for the FEXT from the other primary disturbing lines, thereby offsetting the effects of the crosstalk In April 2010 the ITU-T approved the G.993.5 standard for VDSL2 vectoring VDSL2 bit-rate performance is nearly doubled by cancelling the FEXT Pune, India, 13 – 15 December 2010 16

Unified Home Networking Standards -G.hn supports home networking rates up to 1 Gb/s -One standard for in-home coax, twisted pair, and power wires -Support of IPTV with Multicast and full QoS (quality of service) -Relay-node operating enable excellent coverage throughout the premises -Very low complexity home networking (G.9955) being developed to support Smart Grid energy management Pune, India, 13 – 15 December 2010

ITU-T WP 1/15 Passive Optical Network access Recommendations in Force G.983 BPON (622 / 155 Mbps) G.984 GPON (2.4 / 1.2 Gbps) G.985 point-to-point EPON (100 Mbps) G.986 point-to-point EPON (1 Gbps) G.987 XGPON (10 / 2.5 Gbps) – SR and PMD layers Work in progress for June 2010 G.987 XGPON (10 / 2.5 Gbps) – TC layer G.988 Generic OMCI (PON management) Further work G.987 XGPON2 (10 / 10 Gbps) ? Pune, India, 13 – 15 December 2010

Ethernet over Transport (EOT) WP3/15 - Transport Network Structure Matrix Organization and key relationships Circuit Transport Packet Transport Q3/15 Coordination, Terminology Lead SG activities (OTNT SWP) IEEE 802 Q9/15 Equipment, Performance Network Protection/Restoration OTN Ethernet over Transport (EOT) MEF Q10/15 OAM, Services Q11/15 Interfaces Structures & Mapping IETF Q12/15 Architecture MPLS-TP SDH OIF Q13/15 Timing & Synchronization PDH Q14/15 Management & Control TMF Q15/15 Test Equipment 19 Pune, 15 December 2010

Optical Transport Network (OTN) Evolution OTN Heirarchy recently extended “at both ends” to support 40/100G services per wavelength and groom at GbE (1000BASE-X) granularity New Flexible ODU (ODUflex) supports future Constant bit-rate (CBR) clients and arbitrarily sized packet flows

ODUflex Two flavors of ODUflex standardized Circuit ODUflex Supports any possible client bit rate as a service in circuit transport networks CBR clients use a bit-sync mapping into ODUflex (239/238xthe client rate) Packet ODUflex Creates variable size packet trunks (containing GFP-F mapped packet data) for transporting packet flows using L1 switching of a LO ODU In principle, can be of any size, but in a practical implementation it will be chosen to be multiples of the lowest tributary slot size in the network Similar to VCAT (virtual concatenation), but avoids differential delay problem by constraining the entire ODUflex to be carried over the same higher order ODUk, and provides one manageable transport entity per service (while also limiting the application to ODUflex that fits within one higher order ODUk) ODU k ODUflex ODUk Circuit ODUflex Packet ODUflex

Transport Technology to suit any required granularity BROADBAND NETWORKS MPLS(-TP) LSP used as transport technology GMPLS used as LSP-TP control plane LSP bandwidths will exceed 0.5 Gb/s ULTRA-BROADBAND NETWORKS OTN ODU(flex) provides a greener UB LSP alternative GMPLS used as ODU control plane Operators can route packet flows in future through sub-Lambda-LSPs and Lambda-LSPs OTUk HO ODUk ODUflex ODU EC/PW/IP EVC/PW/IP ODUk 10/40/100 Gb/s traffic traffic traffic EVC/PW/IP EVC/PW/IP EVC/PW/IP EVC/PW/IP EVC/PW/IP EVC/PW/IP EVC/PW/IP EVC/PW/IP EVC/PW/IP EVC/PW/IP Transport Technology Evolution LSP LSP LSP BW growth fewer LSPs LSP LSP >0.5 Gb/s LSP LSP LSP Ethernet 802.3 Ethernet 802.3

Conclusions Standardisation happens at the forefront of technology: just before market introduction ITU can help leverage the knowledge of academic environment Good reserach alone is insufficient: dissemination of results via standards increases payback ITU-T SG 15 welcomes new ideas and new people and organisations to remain in leading position SG 15 is happy to organize brainstorming sessions to make experts familiar with new trends: proposals are welcome Formalities exist, but are limited. Secreteriat is there to help Next plenary meeting: Febr. 2011 in Geneva Pune, India, 13 – 15 December 2010