Maximum Allowable Quantities and the Fire Hazard Analysis

Slides:



Advertisements
Similar presentations
Classification of Building Construction Types
Advertisements

East Hampton High School July 2013 – July 2014 Design Phases.
Regulations (Standards - 29 CFR) Flammable and Combustible liquids
Thomas Izbicki, P.E. Rolf Jensen & Associates, Inc. Plano, TX
Chemical Storage. Objectives Separating incompatible materials Special hazards Flammable storage cabinets Corrosives cabinets Special versus general.
Flammable and Combustible Liquid & Compressed Gas Handling and Storage
FLAMMABLE AND COMBUSTIBLE LIQUIDS
Biodiesel & Fire Permits Presented by the Seattle Fire Department for the Department of Ecology Biodiesel Permitting Workshop Seattle, Washington February.
Martin Gresho, PE Fire Protection Engineer FP2FIRE.
HAZARDOUS MATERIAL MANAGEMENT PLAN Office of the Fire Marshal Glendale Fire Department December 2005.
Seismic Code Highlights Determining what level of Seismic Restraints are Required Arkansas Fire Prevention Code 2002 Based on the IBC 2000.
Temporary storage Sven Hagemann GRS. Types of temporary storage 1.Storage of commodity mercury  Dealer, wholesaler, governmental stocks 2.Storage of.
Building Construction A fire resistive rating (FRR) is given in minutes or hours and relates to how long it takes to burn through a given material. Expressions.
Suzanne Reister, Program Manager Paula Vanderpool, Program Assistant North Central Washington Workers’ Comp Trust Chemical Hygiene – Hazardous Chemicals.
Fire Code Applied to Laboratories A Chemist’s View John DeLaHunt, MBA, ARM 2011 Texas Fire Marshals’ Conference Austin, Texas October 19, 2011.
Lab Inspections State Fire Marshal’s Office. Applicable Codes 1999 BOCA Business Occupancy 1999 BOCA Fire Prevention Code 2000 NFPA 101, Life Safety Code.
Fire Marshal’s Office Department of Environmental Safety LABORATORY FIRE SAFETY LABORATORY. FIRE SAFETY.
Department of Fire and Building Safety Code Review Official III Plan Reviewer Tony Bradshaw General filing questions:
Site Planning and Layout  In the design phase of a facility, fire protection requirements are considered in the site layout  Water supply, traffic and.
IBC 2006 Chapter 5 Building Height and Areas After determining occupancies, the code analysis determines what height and areas are allowable for the occupancy.
NFPA Chapter 6 Chapter 6 is used to classify the occupancy and the hazard contents Proper classification is used to guide the implementation of.
Safe Handling of Flammable and Combustible Liquids
HMT 1C 24-1 u Chapter 24 –Fixed Facility Incident Consideration Haz Mat Incident Considerations.
CHEMICAL STORAGE CLASSIFICATION OBJECTIVE: UNDERSTAND HOW CHEMICALS ARE PROPERLY STORED IN A LABORATORY FACILITY CLASSIFY CHEMICAL EXAMPLES USING THE COLOR.
Flammable and Combustible Liquids. Flammable liquids Class I - liquids have flashpoints below 100 degrees F, with vapor pressures not exceeding 40 psia.
Fire.
Hazardous Materials Transportation
NFPA 13: Installation of Sprinkler Systems
Laboratory Safety-Flammable Liquids Flammable Liquids and Fire Codes for Laboratories.
FLAMMABLE AND COMBUSTIBLE LIQUIDS
Unit 8: Portable Fire Extinguishers & Smoke Control Management Systems
On your own piece of paper list the following items Fire extinguisher Fire blanket Eye wash station Safety shower Fume hood Goggle sanitizer Next to each.
OBC 2009 CHAPTER FIVE GENERAL BUILDING HEIGHTS AND AREAS.
Safety Unit II.
Michigan’s Hydrogen Rules Department of Environmental Quality.
Fire and Emergency Services Company Officer — Lesson 17 Fire and Emergency Services Company Officer, 4 th Edition Chapter 17 — Preincident Planning.
Occupancy Classification Under NFPA 13 Examine the proposed facility and make recommendation on the Occupancy Classification Used to classify fuel loads.
Session IV Chemical Storage Signage Chemical Inventory Physical Storage Storage Room Environment Waste Management Material Safety Data Sheets.
Hazard Communication You Don’t Have To Be a Chemist To Understand Hazardous Chemicals.
Land Use and Development Regulations © 2010 Project Lead The Way, Inc.Civil Engineering and Architecture Our object in the construction of the state is.
© 2006 ITT Educational Services Inc. CD230 Architectural Design & Drafting: Unit 10 Slide 1 Unit 10 Commercial Construction.
Building Codes. Codes  Building Code –Regional  BOCA, SBCCI, CABO, UBC, CITY OF DALLAS, –National  IBC  Fire Code –NFC, UFC, NFPA, Life Safety 101.
3.7.3 Student Book © 2004 Propane Education & Research CouncilPage Identifying Safe Handling Practices for Flammable and Combustible Liquids Injecting.
Hazardous Materials Subpart H. Subpart H Standards Compressed Gases Acetylene Hydrogen Oxygen Nitrous Oxide Flammable.
Indiana Fire Code.
Fire Inspection and Code Enforcement, 7 th Edition Chapter 4 — Construction Types and Occupancy Classifications Inspector I.
Building Classifications: Construction Types.  Based on how the building is constructed.  Relates to:  Materials used  Combustibility  Fire-resistance.
Building Classifications: Occupancies.  Most things have classifications  Objective classifications  Drivers’ licenses  Hazardous materials  Tests.
NFPA 2 Overview Susan Bershad, Staff Liaison, NFPA.
Emergency Planning and Community Right-to-Know Act Tier II Inventory Form Preparing to Submit Part 1 of 2 October
DT 1320 BIM UNIT 1 INTRO TO ARCHITECTURAL DESIGN AND BIM.
The Shepherd Chemical Company Lisa Thamann 11/12/2013 AMMONIUM NITRATE A New Understanding.
Building Construction
Land Use and Development Regulations © 2010 Project Lead The Way, Inc.Civil Engineering and Architecture Our object in the construction of the state is.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
DoD Fuels Laboratory Standards UFC
Hazardous materials: What to look for
Dan Cain Oregon OSHA Portland Consultation Manager
FIGURE Triflic acid [trifluoromethanesulfonic acid (TA)]
Chapter 2 Building Occupancy
MAJED A. DABDOUB, P.E.
NFPA 5000 Occupancy Classifications
City of Healdsburg Construction Codes Amendments & Adoption: 2016 Building Standard Codes Title 24 Parts 1 Thru International Property Maintenance.
RULES OF ENGAGEMENT.
Land Use and Regulations
Land Use and Development Regulations
Building Descriptions
Two Minute Drill – Residential 3
Hazard Alert: Fire inside a fume hood
Presentation transcript:

Maximum Allowable Quantities and the Fire Hazard Analysis Presented by R. Paul Valentine

Ion Beam Facility Sandia National Laboratory

Facility Use and Classification Ion beam irradiation for materials research utilizing three accelerators (HVEE, tandem, pelletron) Study material defects and their effect on electronic, photonic and/or mechanical properties Limited hazardous materials No vital DOE programs or safety-class systems

Site Layout

Floor Plan

Sectional View

Beam Lines

Project Description FHA for Newly Constructed Ion Beam Lab In-depth technical assessment of fire protection and life safety features Facility fire safety objectives of DOE Order 420.1B Life safety objectives of DOE Order 420. 1B and DOE Order 440.1B “Highly Protected Risk” objectives of DOE Order 420.1B

Fire Hazard Analysis Process Conceptual Design Preliminary FHA (2006) Facility Construction 90% construction Draft FHA Development (2010) 100% Construction Partial Occupancy and Equipment Set UP Final FHA Development (2010)

Preliminary FHA (PFHA) Required to fulfill requirements of DOE orders and Sandia National Laboratory requirements Establishes critical path for entire project Identification of Code of Record IBC and IFC,2006 edition NFPA 101, 2003 edition Occupancy Classification

Occupancy Classification Section 304-Business Group B Laboratories: testing and research This section identifies the general characteristics and lists examples of occupancies that are classified in Group B. Note that the description recognizes the need for limited storage spaces that are incidental to office occupancies. Must not exceed maximum quantities of hazardous materials allowed in Section 307.

Occupancy Classification NFPA 101 *Business Occupancy * Based upon associated hazard and intended use at time of PFHA

Site Visit for FHA Users Involvement Challenges: Use of labs Chemicals Users “wish list” of materials Classification of Liquids Use of future materials, unknown

Classification of Materials Type of material Quantity of material Storage practice Container type location

Material Storage Limitation Control Areas (MAQ’s) Indoor (2) Outdoor IBC Requirement IFC Requirements NFPA 45 NFPA 1

Control Area Inside a building, a control area is a space bounded by exterior walls, fire walls, fire barriers, horizontal assemblies, roofs or a combination of these. The amount of hazardous materials stored and used in a control area must be equal to or less than the MAQ (IBC).

Control Area The MAQ is based on the physical state, situation and hazard classification of the material. Up to the MAQ for each class of hazardous material is permitted in each control area (IBC). The concept of the control area is to limit the maximum allowable quantity (MAQ) of hazardous materials per control area rather than per building, and then limit the number of control areas within each building (IBC).

Control Area

Control Area

Development of FHA MAQ’s Identified (Business Occupancy) Tables summarize General limitations

FHA Comments Identify Materials with Classification Identify MAQ’s for Actual Quantities Tables need to Reflect Actual Materials, not in General Terms Apply later edition of NFPA 1 (2006) Modify Occupancy Classification from Business Occupancy to Industrial

Comment Resolution Development of Material Inventory Tables reflect actual user materials Used code of record No need to change occupancy classification (MAQ not exceeded)

Code Change Impact NFPA 1 (2003 Ed)- MAQ’s same for both occupancies (one table)

Code Change Impact NFPA 1, (2006 Ed) Tables were added for specific occupancies such as business 2006 Industrial Occupancy Table is the same as the 2003 Business/Industrial 2006 Business Occupancy Table is different

Material Inventory Example

IFC MAQ’s per Control Area Storage Use-Closed Systems Use-Open Systems Material Class Solid pounds (cubic feet) Liquid gallons (pounds) Gas (cubic feet at NTP) Solid Pounds Combustible liquid II IIIA IIIB N/A 120 1,2 330 1,2 13,2002,3 1201 3301 13,2003 301 801 3,3003 Flammable gas Gaseous Liquefied 30 1,2 1,000 1,2 301,2 1,0001,2 Flammable liquid 1A, 1B and 1C 10 1 30 1 Combination flammable (1A, 1B, 1C) 120 1,2,5 1201,5 301,5 Flammable solid 1251,2 1251 251 Organic peroxide UD I III IV V 12,4 51,2 501,2 NL (1)2,4 (5) 1,2 (50) 1,2 (125) 1,2 0.254 11 501 N/L (0.25)4 (1) (50)1 (125)1 101 (1)1 (10)1 (25)1 Oxidizer 4 36 2 1 101,2 2501,2 4,0002,3 (10)1,2 (250)1,2 (4,000)2,3 N /A 21 2501 4,0003 (2)1 (250)1 (4,000)3 1,0003 (1,000)3 Oxidizing gas liquefied 151,2 1,5001,2 Pyrophoric material 4 2,4 (4)2,4 502,4 14 (1)4 102,4 Unstable (reactive) 3 (1) 2,4 (5)1,2 (50)1,2 10 2 2,4 0.25)4 Water reactive 51 (5)1

Lessons Learned Establish an occupancy classification to provide flexibility for future Identify actual materials during PFHA Identify quantity of material during PFHA Partner with user of facility and have open communication to meet everyone’s needs

Questions?

Ion Beam Facility Sandia National Laboratory