A Universal Free-Standing Accessory to Improve ICP Productivity Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd., Pocasset, MA 02559,

Slides:



Advertisements
Similar presentations
Titan EP Training For Programming a New Titan EP August 11, 2009.
Advertisements

Titan EP Training For Modifying a Preprogrammed Titan EP August 11, 2009.
Increasing Demand for Reduced Test Turn Around Time (TAT) and Specimen Quality Emergency Department “I want SPEED” “I want specimen QUALITY & PURITY”
Layer 3 Switching. Routers vs Layer 3 Switches Both forward on the basis of IP addresses But Layer 3 switches are faster and cheaper However, Layer 3.
GASMET DX4040 Antti Heikkilä.
Chapter 1 - VB 2008 by Schneider1 Chapter 1 - An Introduction to Computers and Problem Solving 1.1 An Introduction to Computers 1.2 Windows, Folders, and.
Retail In-store applications Mobile price labelling and mark down.
A Modern Approach to Controlling ICP Spray Chamber Temperature Jerry Dulude, Glass Expansion,
Ion Sources Some characteristics of ion sources (especially in high precision work): It should have high efficiency in generating ions of the element of.
Elemental Scientific | | PC 3 Advantages Thermal stabilization of spray chamber improves long-term stability Reduces effect.
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
IDDepth δ 13 CCarbonNitrogenδ 13 C Depth: (cm)(‰)(%) (‰)(cm) Gr. 3-5A %0.17% Gr %0.12% Gr %0.09%
© Copyright 2002 ABB. All rights reserved. - Microelectromechanical Systems for Process Analytics IFPAC 2003 Dr. Berthold Andres ABB Automation Products.
Outline of Presentation Introduction to Analog Interfaces, Inc. Introduction to the Indenter Polymer Aging Monitor Principle of Indenter measurements How.
Printed by Approaching a Universal Pneumatic Nebulizer – the next step Jerry Dulude and Ron Stux (USA), Vesna Dolic and Peter Liddell.
Introducing the LabFit AS-3000 Series Automated pH Analyzers Labfit Pty Ltd 102 Goodwood Parade PO Box 343 Burswood, Western Australia 6100 Tel +(618)
Introducing the EASY-nLC™
Printed by Approaching a Universal Pneumatic Nebulizer Jerry Dulude (USA), Vesna Dolic and Peter Liddell (Australia), Glass Expansion.
Temperature-Related Stability in Plasma Spectrometry Jerry Dulude, Ron Stux, and Vesna Dolic, Glass Expansion,
Summary Slide Allegro Vivace (Fast and Lively) Your Logo Here Automated Financial Reconciliations Website – Automated Financial.
Summary Slide Allegro Vivace (Fast and Lively) Your Logo Here Automated Financial Reconciliations Website – Automated Financial.
Design and Development of High Performance PC Based Logic Analyzer MSc Project by Rab Nawaz Advisor: Dr. Shahid Masud.
ChemConnect Leading in negotiation solutions for commercial products.
PH and ICP Techniques Clemson. pH quality control checks Scoop 2 checks One blank Double scoop 6 samples Tag set with lab number, check, and blank positions.
Chem415 Quantitative Bio-Element Imaging Center (QBIC): Part II APRIL 13, 2015 DIRECTOR: PROFESSOR THOMAS V. O’HALLORAN MANAGING DIRECTOR: KEITH MACRENARIS,
Agilent 7500 ICP-MS Date: 28JUL2005.
Windows 1.0 and later Windows 95, Windows 98, Windows Me, Windows 2000.
Introducing the LEO 1400 Series
Client Case Studies Revenue Assurance & Revenue Intelligence.
Materials Characterization Lab Elemental Analyses by ICP-AES Henry Gong, Senior Analytical Chemist September 10, 2008.
Consultancy.
The determination of lead by MD-HG-AFS in APMP*-QM-P3 comparison Lu Xiaohua, Lu Hai, Ma Liandi, Cui Yanjie National Research Center for Certified Reference.
Printed by Monitoring Metals Hypersensitivity by Measuring Chromium, Cobalt and Molybdenum in Whole Blood Elzbieta (Ela) Bakowska,
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
Welcome! West Allis: Yes you can!. Terms: Data – Any form of information stored in a computer Data – Any form of information stored in a computer Database.
ICP Shutdown. Pump Flush the nebulizer spray chamber with acid for 5 minutes by choosing the location of the 3% HNO3 and moving the sample needle “position”.
Smart solutions for faster product and process innovation InsightFaraday  A New Approach to Boosting R&D Productivity.
A Single Calibration for Waters and Soil Samples Performing EPA Method 8260 Anne Jurek – Applications Chemist.
Varian 920-LC Integrated Analytical HPLC
Advantages of a Syringe Driven Sample Introduction Accessory for ICP Spectrometry Jerry Dulude and Scott Bridger Glass Expansion.
May03-12: Freeze-Thaw Concrete Chamber Controller Team Members: Team Members: Craig Rueter Craig Rueter Steven Spencer Steven Spencer Jason Stowe Jason.
IChemExplorer iChemExplorer ™ Chemistry Screening Tools.
Discovering a New Choice in ICP- MS Low Volume Handling MVX-7100 µL Workstation.
A UNIVERSAL PROGRAMMABLE TEMPERATURE SPRAY CHAMBER Jerry Dulude, Glass Expansion,
Doc.: IEEE /97 Submission March 1998 Pat Kinney, IntermecSlide 1 Wireless Solutions Continuum of needs for wireless products No one product which.
Automating Continuous Gas Lift
Printed by Techniques for Increasing Productivity in ICP Spectrometry Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd.,
SPRAY CHAMBER TEMPERATURE: A CRITICAL (YET OFTEN MISSING) PARAMETER IN ICP EXPERIMENTS Jerry Dulude, Ron Stux, and Vesna Dolic, Glass Expansion,
Nitro New Program Training December 1, Nitro bridges the gap between compact basic dispensers and large feature full dispensers too bulky for smaller.
Innovations in ICP Sample Introduction
Or Are You Also Wandering ? Tzu-Jui Wang, Visual Communications Lab, Taiwan
GROWIFY What Will You GROW? Presented by: Erik Tetland.
Printed by A New Versatile Programmable Temperature Spray Chamber for ICP Jerry Dulude and Ron Stux (USA), Vesna Dolic (Australia),
2006 HPLC Market Analysis. 180,000 operating systems worldwide This figure is growing by ~6% every year Total revenue in 2006 was $3225M* To put this.
A STAND-ALONE DEVICE TO SPEED ICP ANALYSES Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd., Pocasset, MA 02559,
Biochemical instrumental analysis-14
1 Logic State Analyzers A tool for observing logic states of multiple signals at once, in time A logic probe can show only one bit at a time. Extremely.
Equipment Familiarization Hanse Environmental Inc. VTC Series.
1 In-house Training on ICP-MS. ICP-MS??? Inductively Coupled Plasma Mass Spectrometry or ICP-MS is an analytical technique used for elemental determinations.
Eric Burgstrom, Rebecca Haley, Keaton Nahan, Dr. James Mack and Dr
Azure Hybrid Use Benefit Overview
Introduction to Decision Analysis & Modeling
August 23, 2000 R.N. Dubois Dow Chemical
The Analysis of Soils and Waters in Accordance with U. S
Carrier moves through the valve while sample is drawn into the loop and valve Load: 4 seconds.
Load Sample is loaded into the P7+ loop in 4 seconds. Carrier runs through the P6 valve.
Particle Insight Getting Started – Start-up & New Run….
Particle Insight Getting Started – Start-up & New Run….
GASMET DX4040 Antti Heikkilä 1.
Gary Yanik (PDR-Separations) Leo Hsu, Xiqin Yang, Dave Thornton (GSK)
Presentation transcript:

A Universal Free-Standing Accessory to Improve ICP Productivity Jerry Dulude, Glass Expansion, Inc., 4 Barlows Landing Rd., Pocasset, MA 02559,

Glass Expansion Sample Cycle for Unattended ICP Analysis AS to sample Smpl fills line Plasma equil Integration AS to rinse Rinse Smpl empties line

Glass Expansion Benefits of Decreasing the Analytical Cycle More samples/hour Faster sample turn-around time Delay procurement of additional instruments Reduce consumables cost/sample Argon Torches Nebulizers Cones

Glass Expansion Methods to Reduce Analysis Cycle (without degrading performance) Minimize dead volume Software approaches Valve switching

Glass Expansion Removing Dead Volume Nebulizer – EzyFit Spray chamber – Helix Internal Standard – Low volume chamber

Glass Expansion Software Approaches to Speeding Analysis Fast pump in rinse mode longer equilibration Predictive Rinse QC’s complicated Risk of carryover Intelligent Rinse Rinse is based on sample results Analyzes rinse to determine optimum time Modest productivity gain

Glass Expansion Niagara™ Rapid Rinse Accessory Interfaces between ICP & Autosampler Reduces required rinse time Programmable delay time Less than 8 inches high Includes adj. height stand

Glass Expansion How Niagara Works Analysis Rinse

Glass Expansion Niagara Interface – no software required Started with hardware trigger on AS Recently modified to serial interface Serial cable runs from ICP computer through the AS to the Niagara. Each Niagara is preprogrammed for a specific ICP/AS combination. Niagara ICP-OES or ICP-MS Autosampler PC

Glass Expansion Niagara Time Saving Elan 6000 ICP-MS, Hill Labs, New Zealand Standard SystemWith Niagara Probe to sample44 Uptake delay20 Stabilization88 Read40 Probe to rinse44 Rinse (washout)1610 Rinse (rinse)140 Total (seconds)10686 Total Rinse (seconds)38 = Rinse steps for nebulizer & spray chamber 30 second rinse10 second rinse

Glass Expansion ICP-MS Carryover Comparison BFeZnSeMoCdSnSbTlBi 5ppm Solution Blank Blank Blank Blank Blank Blank BFeZnSeMoCdSnSbTlBi 5ppm Solution Blank Blank Blank Blank Blank Blank Standard method without Niagara With Niagara

Glass Expansion ICP-MS Carryover Comparison Boron Moly Zinc Thallium

Glass Expansion On-Line Productivity Calculator

Glass Expansion Payback with Niagara- Commercial Lab Without NiagaraWith Niagara Samples/hour3445 Samples/ 8 hour day Extra samples per day088 Extra samples less QC’s079 Price per sample$50 Extra revenue per day$0$3950 Extra revenue per month$0$79,000 Extra revenue per year$0 $948,000

Glass Expansion Summary Decrease dead-volume in sample introduction system to reduce rinse time Software approaches produce marginal productivity improvements Niagara produces clear gains in productivity without jeopardizing performance.