KEKB Crab Development K. Hosoyama (KEK) Crab Cavity for HER Crab Cavity for LER Crab Cavity for KEKB History of Crab Cavity R&D Characteristics of Crab.

Slides:



Advertisements
Similar presentations
Stochastic cooling and 56 MHz SRF update for Run-14 W. Fischer 21 January 2014.
Advertisements

Cavity tuning etc Cryogenics Cavity tuning Tuner Input couplers 6 th October 2009 video meeting K.Nakanishi.
Accelerator Science and Technology Centre Prospects of Compact Crab Cavities for LHC Peter McIntosh LHC-CC Workshop, CERN 21 st August 2008.
Juliette PLOUIN – CEA/SaclayCARE’08, 3 December /21 Superconducting Cavity activities within HIPPI CARE ‘08 CERN, 2-5 December 2008 Juliette PLOUIN.
Slim crab cavity development Luca Ficcadenti, Joachim Tuckmantel CERN – Geneva LHC-CC11, 5th LHC Crab Cavity Workshop.
KAGEYAMA, T. Open Meeting for Proto-Collaboration March 19, 2008.
ANL HWR Cryomodule Status Update 27 January 2015 Zachary Conway On behalf of the ANL Linac Development Group Argonne National Laboratory Physics Division.
Progress of SC RF Cavity during the RF Group May 10, 2007.
SRF Results and Requirements Internal MLC Review Matthias Liepe1.
R&D Status and Plan on The Cryostat N. Ohuchi, K. Tsuchiya, A. Terashima, H. Hisamatsu, M. Masuzawa, T. Okamura, H. Hayano 1.STF-Cryostat Design 2.Construction.
ESS cavities interfaces
Zenghai Li SLAC National Accelerator Laboratory LHC-CC13 CERN, December 9-11, 2013 HOM Coupler Optimization & RF Modeling.
Cavity status; recent KEK activities : Hayano (1) STF CM-1 cavities are; MHI-014: 3-rd VT:36MV/m (finished) MHI-015: 3-rd VT: > 18.4MV/m.
Status of crab crossing studies Presented by NAKANISHI Kota (KEK) 2008/1/25.
Blade Tuner assembly Instruction for tuner assembly on a cryomodule May
STF Plan & Schedule H. Hayano, KEK. Superconducting RF Test Facility Comprehensive Test Facility dedicated to ILC SC-RF R&D (expandable to FEL, ERL) for.
Detail discussion of S1 Global at STF H. Hayano (KEK) GDE Mar 3-6, 2008.
STF plan overview H. Hayano, KEK LCPAC 02/25/2005.
STF status Mar.22,2005 H. Hayano, KEK. STF Phase 1 Test Accelerator DC gun : 200kV CsTe photocathode for quick start UV(262nm) Laser (337ns spacing, 2820bunches)
ILC WG2 (Main Linac System) status & report H. Hayano, KEK.
S.Noguchi (KEK) ILC08 Chicago , Nov . 17, Cavity Package Test in STF STF Phase-1 E. Kako, S. Noguchi, H. Hayano, T. Shishido, M. Sato, K. Watanabe,
July LEReC Review July 2014 Low Energy RHIC electron Cooling Sergey Belomestnykh SRF and RF systems.
KEK R&D for LHC Plan of 800MHz Cavity Calculation of 400MHz Cavity 16 th September 2009, LHC-CC09 at CERN K.Nakanishi.
KEKB RF Cavity Commissioning and Operation Yoshiyuki MORITA KEK Introduction Commissioning Frequency tuner Oscillation of high current crabbing beam Trip.
LCWS13, November 2013 At the University of Tokyo W.–D. Möller Status of the TTF3 RF Power Coupler.
● Offer the reliable system to the Asian regional facility STF. ● Improve TTF design and demonstrate in the beam line for RDR / TDR. ● Establish industrial.
1 HIGH ENERGY ACCELERATOR RESEARCH ORGANIZATION KEKB Review Committee/ NAKAI Hirotaka KEK Crab Cavity - Cryogenics - KEKB Crab Cavity Group - presented.
I. Ben-Zvi Update Ilan Ben-Zvi for the Stony Brook, BNL and AES SPL teams Presented by Rama Calaga.
Test plan for SPL short cryomodule O. Brunner, W. Weingarten WW 1SPL cryo-module meeting 19 October 2010.
56 MHz SRF Cavity Thermal Analysis and Vacuum Chamber Strength C. Pai
1Matthias LiepeAugust 2, 2007 Future Options Matthias Liepe.
Date 2007/Oct./23 FNAL-GDE-Meeting Global Design Effort 1 Cryomodule Interface Definition (FNAL-GDE-Meeting) N. Ohuchi.
Nov. 28, 2003RF System Overview, K. Akai1 RF System Overview Contents: ◆ High beam current and measures ◆ Construction ◆ Damping ring RF system ◆ Crab.
Bunch Separation with RF Deflectors D. Rubin,R.Helms Cornell University.
LHC Cryostat evaluation Nikolay Solyak Thanks Rama Calaga, Tom Peterson, Slava Yakovlev, Ivan Gonin C11 workshop. FNAL, Oct 27-28, 2008.
The Superconducting cavities of the European Spallation Source Superconducting Technologies Workshop CERN – 4 & 5 December 2012 Sébastien Bousson (CNRS/IN2P3/IPN.
Date 2007/Sept./12-14 EDR kick-off-meeting Global Design Effort 1 Cryomodule Interface definition N. Ohuchi.
KEKB crab RF architecture & controls K.Nakanishi KEK Dec. 16, 2010 LHC-CC10 1.
Update on LHC 800MHz Crab Cavity Conceptual Design Liling Xiao, Zenghai Li Advanced Computations Department, SLAC Presented at LARP-CM12, April 9, 2009.
S1-Global status report KEK Norihito Ohuchi 2008/11/171ILC08-GDE-Meeting-Chicago.
Preparation procedure and RF processining of cERL-ML power coupler at KEK Hiroshi Sakai, Takaaki Furuya, Masato Sato, Kenji Shinoe, Kensei Umemori, Kazuhiro.
Experiences with KEK-B Crab Cavity KEKB and Crab Cavity History of Crab Cavity Construction and Operation of KEKB Crab Cavities What the KEKB Crab Cavity.
CW Cryomodules for Project X Yuriy Orlov, Tom Nicol, and Tom Peterson Cryomodules for Project X, 14 June 2013Page 1.
NSCL Professor, SRF Department Manager Kenji Saito Status of FRIB: design plans, cavity and cryomodule development TTC Meeting November TTC meeting.
Ralf Eichhorn CLASSE, Cornell University. I will not talk about: Cavities (Nick and Sam did this) HOM absorbers (did that yesterday) Power couplers (see.
Spoke section of the ESS linac: - the Spoke cryomodules - the cryogenic distribution system P. DUTHIL (CNRS-IN2P3 IPN Orsay / Division Accélérateurs) on.
Developments of new treatment techniques for SRF cavities at KEK HORIZONTAL HPR FOR PERFORMANCE RECOVERY Yoshiyuki MORITA Motivation of developing HHPR.
The HiLumi LHC Design Study is included in the High Luminosity LHC project and is partly funded by the European Commission within the Framework Programme.
Shuichi NoguchiTTC Meeting at Milano, Injector Cryomodule for cERL at KEK Cavity 2 Prototypes were tested. Input Coupler 2 Couplers were tested.
ESS Cryomodule Status Meeting – Introduction | | Christine Darve Introduction to Cryomodules for the ESS 2013 January, 9 th Christine Darve.
650 MHz, Beta = 0.9, 11 April 2012Page 1650 MHz, Beta = 0.9, 11 April 2012Page 1 Project X Beta = 0.9, 650 MHz Cavity and Cryomodule Status Tom Peterson.
Operation Status of the RF Systems and Taiwan Photon Source
CERN – Zanon discussions
CW couplers; KEK injector couplers Eiji Kako (KEK, Japan)
WP5 Elliptical cavities
Re-entrant BPM R&D for ILC Main Linac
Odu/slac rf-dipole prototype
TTC Topical Workshop - CW SRF, Cornell 12th – 14th June 2013
Crab Cavity R&D Plan Kirk 1 6/Dec/2016
LHC Crab Cavity Conceptual Design at SLAC
Design Fabrication and Processing Group H. Padamsee
Jiyuan Zhai ( IHEP ) TTC Meeting, JLAB, 6 Nov 2012
Bunch Separation with RF Deflectors
KEK injector cryomodule
HIE-LINAC status report
Overview of SRF system of Ring and Linac (1)
IHEP Cryomodule Status
IHEP ILC Cavity Status Jiyuan Zhai (IHEP)
CEPC-650MHz Cavity Cryomodule
V. Veshcherevich Cornell University
Presentation transcript:

KEKB Crab Development K. Hosoyama (KEK) Crab Cavity for HER Crab Cavity for LER Crab Cavity for KEKB History of Crab Cavity R&D Characteristics of Crab Cavty Cryostat for Crab Cavity Frequency Tuner High Power Test at D10 Test Stand Commissioning of Crab Cavities for KEKB Summary

Crab Cavities for KEKB Collision Point Tsukuba Nikko Oho Fuji 8 SC-Cavities KEKB LER 3.5 GeV HER 8.0 GeV RF freq MHz Cross. Ang. 2 x 11 m rad. Mt. Tsukuba Photon Factory 2 Crab Cavities Nikko Tsukuba 2 Crab Cavities at “Nikko” Helium Ref. Beam-bunch wiggle around the whole ring! Advantage: We can use existing cryogenic system for Acc. S.C. cavities

Milestone of KEKB Crab Cavity Development 1)Full Scale 500MHz Prototype Crab Cavity 2 Nb Cavities # 1 & # 2 Coaxial Coupler Prototype Horizontal Cryostat ( # 2 was Installed into Prototype Horizontal Cryostat for Cool down Test) Installation of 2 crab cavities in KEKB was decided 2) KEKB Crab Cavity 509MHz 2 Nb Cavities for LER, HER Cold Tested in Vertical Cryostat Assembling and High power test Installation Commissioning and Operation 0) 1/3 scale 1.5 GHz model ~

Conceptual Design of KEKB Crab Cavity E EB The squashed cell shape cavity scheme was studied extensively by Akai at Cornell in 1991 and 1992 for CESR-B under KEK-Cornell collaboration. We adopted this design as “base design”! Crab Kick TM110 B-field Coaxial Coupler TM010, TE111 Squashed Cell Shape Cavity TM110* Top View Squashed Cell Shape Cavity

Characteristics of KEKB Crab Cavity “Squashed cell shape” design is adopted to push up the unwanted regenerative mode of the TM 110 crab mode up 700MHz Higher Order / the Lowest Mode Damped Cavity; Large beam pipe is designed for Higher Order Mode damping Coaxial coupler is put into the cell through beam pipe for the Lowest TM 010 acceleration mode damping Coaxial coupler must adjust on axis of crab cavity Head of coaxial coupler must cool to keep superconductive state Notch filter in the coaxial coupler reject outgoing crab mode Big concern for the Multipacting at coaxial coupler Non-axial symmetric and large in size cavity design Need care in designing, fabrication and EP of the cavity

Why squashed cell shape cavity? TM110TM010 TE MHz 324MHz 720MHz TM110 - like Mode 500MHz TM010 - like Mode 413.3MHz 700MHz MHz / 677.6MHz Unwanted Modes Crab Mode E B The squashed cell shape cavity scheme was studied extensively at Cornell in 1991 and 1992 for CESR-B under KEK-Cornell collaboration. Degenerative Mode TM110 Unwanted Modes

KEKB Superconducting Crab Cavity Non-axial Symmetric Structure Thickness of 4.5 mm Nb Cavity Reinforced by Ribs Simplified Coaxial Coupler

with coaxial coupler Test Result of Prototype #1 Crab Cavity without coaxial coupler 4.2 K without coaxial coupler 2.8 K Design Esp Esp [MV/m] Q0Q0 RF Performance Test with a Coaxial Coupler; Multipacting was observed at very low RF power, but we could overcome by RF process.

Conceptual Design of Cryostat for KEKB Crab Cavity Top View Input coupler Magnetic Shield ( Jacket Type ) 80 K LN2 Radiation Shield Coaxial Coupler Stub Support Bellows Main He Vessel Monitor Port RF Absorber Frequency Tuning by Adjusting Distance Crab Mode Reject Filter RF Absorber I.D. 240 I.D.100 Frequency Tuning Coaxial Coupler ~30 kHz / mm Stub-Support -- Mechanical Support & Cooling of Coaxial Coupler Jacket-type Helium Vessel (Main He Vessel and Sub He Vessel ) Jacket-type Magnetic Shield Sub Liq. He Vesse ~ 18 kW at LER 1.6 A 1300 bunch ~ 8 kW Characteristics

Cryostat for KEKB Crab Cavity Input Coupler Beam RF Damper Gate Valve 5 m Total Weight ~5ton

Crab Cavity & Coaxial Coupler in Cryo-module Support Rod for Cavity Invar Jacket Type Main He vessel SUS316L Jacket Type Sub He vessel Coaxial Coupler (Nb) Stub Support Crab Cavity Cell Notch Filter Tuning Pipe and Rod RF Absorber Extract TM 010, TE 111 Mode Frequency Tuning Input Coupler Bellows 1)Crab Cavity is hanged by 4 invar support rods. 2)Coaxial coupler is hanged by 4 stainless rods which are supported by 2 support arms. 3)Head position of the coaxial coupler is controlled by 2 tuning rods. 4)Head of coaxial coupler is cooled by liq. helium supplied from stub support. Support Rod for Stub Support Support Arm

Main Liq. He Vessel Input Coupler Stub Support RF Monitor Coaxial Coupler Beam KEKB Crab Cavity Frequency Tuner Main Tuner Mechanical + Piezo 6 mm mm Bellows Driving Plate Cryostat Vacuum End Cell Sub Liq. He Vessel Pickup Probe Main Tuner : Frequency Tuning ~30 kHz / mm Sub Tuner : Adjust Position of Coaxial Coupler Tuning Rod Sub Tuner Mechanical Support Pipe Load Cells Top View 1)The jacketed crab cavity is fixed to the vacuum vessel. 2)Insertion of the coaxial coupler to the crab cavity is controlled by changing position of the sub liquid helium against the end plate by two driving rods. 3) Transverse position of coaxial coupler tip is controlled by adjusting distance D R and D L. DRDR DLDL If the coaxial coupler set in center of crab cavity, there is no RF power flow to pickup probe.

Frequency Tuner Test Frequency Tuner Crab Cavity for HER Resonance Frequency Resonance frequency can be controlled by main tuner. Coaxial coupler position can be controlled by sub-tuner. RF Power 6 mm 1 mm 10 dB Dip of RF power means good position! RF Power at Pickup Probe

Insertion of Coaxial Coupler (1/2) Slide Rotate Assembling the coaxial coupler to the cryostat was very “tough job” Inner conductor of coaxial coupler must be connect tightly without gap Bayonet type connection was adopted Precise alignment was needed; not only the position of axis but also direction of axis ! The insertion tool must be rigid enough to support heavy component and need precise adjustment knobs.

Insertion of Coaxial Coupler (2/2) Crab Cavity (Cryostat) SideNotch Filter Side We could assemble it by using improved Insertion tool!

Move to Test Stand for Cool-down & High Power Test Mt. Tsukuba Crab cavity for HER April 26, st Oct. 16, nd Crab cavity for LER Dec. 6, 2006

Final High Power Test at Test Stand Crab cavity for HER and LER were cooled down without leakage. Resonant frequency could adjust to operating frequency of 508.9MHz. V kick = 1.8 MV and 1.93 MV respectively, exceed the design value of 1.44 MV. Qo – values at design kick voltage were higher than 1x10 9. Cavity and coaxial coupler was cooled stably during the high power test. Cryogenic system worked very well! Frequency tuner of crab cavity HER work very well and Phase stability of crab cavity HER is good. Phase stability of crab cavity LER is not good, but this problem could be saved by RF feed-back system.

Installation & Commissioning of Crab Cavities Installation of Crab Cavities for HER Jan. 8, 2007, for LER Jan. 11, 2007 Crab Cavity for HER Crab Cavity for LER Carrying the crab cavity using crane track Cool-down of Crab Cavities Jan. 29, 2007 Beam Operation Start Feb. 13 e-e- e+e+

SUMMARY During more than 10 years of crab cavity development, We designed and fabricated the crab cavities and related components including the cryostat. We construct the facilities for assembling and cold RF test. 2 KEKB crab cavities have been constructed and installed in KEKB. The crab cavities operate more than 3 years without serious problems. The peak luminocity L peak = 20 x /cm 2 /s was attained under crab on operation. By the successful construction and operation of KEKB crab cavity, the reliability of superconducting crab cavity was proved for future application.