Netherlands Institute for Space Research Development of TES-microcalorimeter arrays and Frequency Domain Multiplexed read-out Henk Hoevers Division Sensor.

Slides:



Advertisements
Similar presentations
Flex Circuit Design for CCD Application ECEN 5004 Jon Mah.
Advertisements

Recent progress with TES microcalorimeters and signal multiplexing J. Ullom NIST NASA GSFC SRON J. Beall R. Doriese W. Duncan L. Ferreira G. Hilton R.
LTD12, Paris Microstructured magnetic calorimeter with meander shaped pickup coil A. Burck S. Kempf, S. Schäfer, H. Rotzinger, M. Rodrigues, T. Wolf, A.
Electrical Techniques MSN506 notes. Electrical characterization Electronic properties of materials are closely related to the structure of the material.
Victoria04 R. Frey1 Silicon/Tungsten ECal Status and Progress Ray Frey University of Oregon Victoria ALCPG Workshop July 29, 2004 Overview Current R&D.
CCD-style imaging for the JCMT. SCUBA-2 technology  the ability to construct large format detector arrays  signal readouts that can be multiplexed To.
TES Bolometer Array with SQUID readout for Apex
Fiber-Optic Communications
Presented by Paul Kasemir and Eric Wilson
RUN HISTORY Preparation: 17/10Cryostat, pumps and electronics mounted in the cabin (total time 2h) 18/10Cooling down to 80mK. Resonances OK (SRON array)
Position sensing in a GEM from charge dispersion on a resistive anode Bob Carnegie, Madhu Dixit, Steve Kennedy, Jean-Pierre Martin, Hans Mes, Ernie Neuheimer,
X-Ray Spectroscopy. 1 eV 100 eV 10 eV Energy (keV) The need for high resolution X-ray spectroscopy Astrophysical Plasmas: Simulation of the emission from.
Science Specification Table 12 keV keV for neutral particles 40.5 cm 2 image plane Electronic Noise 3 keV FWHM Proton Dead Layer
June X-Ray Spectroscopy with Microcalorimeters1 X-Ray Spectrometry with Microcalorimeters.
Fiber Optic Receiver A fiber optic receiver is an electro-optic device that accepts optical signals from an optical fiber and converts them into electrical.
Orit Skorka and Dileepan Joseph University of Alberta, Canada Reducing Crosstalk in Vertically- Integrated CMOS Image Sensors.
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
A new idea of the vertex detector for ILC Y. Sugimoto Nov
Lecture 2 Most basic facts from Electricity needed for understanding telecommunications Local transmission lines in the telephone system Decibels Signals.
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
Performance test of STS demonstrators Anton Lymanets 15 th CBM collaboration meeting, April 12 th, 2010.
Development of Low Temperature Detector S.C. Kim (SNU, DMRC)
Rome, January 17th,2006 Flavio Gatti WHIM and Mission Opportunities TES microcalorimeters in the European context Flavio Gatti University and INFN, Genoa.
X-ray radiation damage of silicon strip detectors AGH University of Science and Technology Faculty of Physics and Applied Computer Science, Kraków, Poland.
ConX – XEUS meeting Panu Helistö, Mikko Kiviranta Utrecht,
A. Monfardini, IAP 30/07/ NIKA (Néel IRAM KID Array) First light at the 30-m IRAM dish NIKA collaboration: - Institut Néel - Grenoble - AIG - Cardiff.
STREGA WP1/M1 mirror substrates GEO LIGO ISA Scientific motivation: Mechanical dissipation from dielectric mirror coatings is predicted to be a significant.
Planar Antenna-Coupled Hot-electron Microbolometer Shafinaz Ali 1, Dan Mccammon 1, Lance D. Cooley 2, Kari.L.Nelms 1, John Peck 3, Daniel Prober 4, Dan.
Silicon Sensor with Readout ASICs for EXAFS Spectroscopy Gianluigi De Geronimo, Paul O’Connor Microelectronics Group, Instrumentation Division, Brookhaven.
WIRELESS MICROMACHINED CERAMIC PRESSURE SENSORS
XEUS cryogenic instrument October 2004 CRYOGENIC SPECTROMETER PROTOTYPE Rationale: Development and demonstration of technical readiness for future.
MANU2: status report Maria Ribeiro Gomes* for the Genoa Group IAP, 14-Nov-05 * pos-doc under TRN HPRN-CT
R&D status of FPCCD VTX and its cooling system Yasuhiro Sugimoto for FPCCD VTX group 1.
EURECA  XEUS EURopean-JapanEse micro-Calorimeter Array Piet de Korte.
MVE MURI 99 Kick-off Meeting R. Barker, Technical Monitor Started 1 May 99 October 1999 Project Introduction and Motivation Millimeter-wave switches may.
Pixel 2000 Workshop Christian Grah University of Wuppertal June 2000, Genova O. Bäsken K.H.Becks.
1 Development of the input circuit for GOSSIP vertex detector in 0.13 μm CMOS technology. Vladimir Gromov, Ruud Kluit, Harry van der Graaf. NIKHEF, Amsterdam,
Fine Pixel CCD for ILC Vertex Detector ‘08 7/31 Y. Takubo (Tohoku U.) for ILC-FPCCD vertex group ILC vertex detector Fine Pixel CCD (FPCCD) Test-sample.
JW den Herder 1 18/10/2004 Science case Main science drivers (comsic vision ): Super Novae and the life cycle of matter Study of cluster evolution.
Status of Development of Metallic Magnetic Calorimeters A.Fleischmann, T. Daniyarov H. Rotzinger, M. Linck, C. Enss Kirchhoff-Institut für Physik Universität.
Beam Tests of 3D Vertically Interconnected Prototypes Matthew Jones (Purdue University) Grzegorz Deptuch, Scott Holm, Ryan Rivera, Lorenzo Uplegger (FNAL)
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
C03 High speed photon number resolving detector with titanium transition edge sensors Daiji Fukuda, Go Fujii, R.M.T. Damayanthi, Akio Yoshizawa, Hidemi.
Low Resistance Strip Sensors – RD50 Common Project – RD50/ CNM (Barcelona), SCIPP (Santa Cruz), IFIC (Valencia) Contact person: Miguel Ullán.
Cryogenic Detectors and Test Infrastructure at the University of Leicester G.W. Fraser Space Research Centre, Michael Atiyah Building, Department of Physics.
PARISUTHAM INSTITUTE OF TECHNOLOGY AND SCIENCE DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING II YEAR/ III SEMESTER LINEAR INTEGRATED CIRCUITS AND.
XEUS Cryogenic Instrument October 2004 Cryogenic X-ray sensor development in US, Europe and Japan Micro-calorimeters Doped - thermistors Astro-E2.
Optical Receivers Theory and Operation
Compilation of Dis-/Advantages of DC-DC Conversion Schemes Power Task Force Meeting December 16 th, 2008 Katja Klein 1. Physikalisches Institut B RWTH.
Metallic Magnetic Calorimeters for High-Resolution X-ray Spectroscopy D. Hengstler, C. Pies, S. Schäfer, S. Kempf, M. Krantz, L. Gamer, J. Geist, A. Pabinger,
Demonstration of a Far-IR Detector for Space Imaging Principal Investigators: C. Darren Dowell (326), Jonas Zmuidzinas (Caltech) Co-Investigators: Peter.
Progress with GaAs Pixel Detectors K.M.Smith University of Glasgow Acknowledgements: RD8 & RD19 (CERN Detector R.&D. collaboration) XIMAGE (Aixtron, I.M.C.,
STATUS OF R&D AT UCSB Paul Szypryt Mazin Lab August 26, 2013.
Philip Bambade, Pierre Barillon, Frédéric Bogard, Selma Conforti, Patrick Cornebise, Shan Liu, Illia Khvastunov Journée PHIL
V.Aulchenko 1,2, L.Shekhtman 1,2, B.Tolochko 3,2, V.Zhulanov 1,2 Budker Institute of Nuclear Physics, , Novosibirsk, Russia Novosibirsk State University,
Low Temperature Detector Design for the particle search Kim Seung Cheon (DMRC,SNU)
전자파 연구실 1. Fundamentals. 전자파 연구실 1.1 Frequency and time Passive circuit elements is emphasized in high speed digital design : Wires, PCB, IC- package.
SiW Electromagnetic Calorimeter - The EUDET Module Calorimeter R&D for the within the CALICE collaboration SiW Electromagnetic Calorimeter - The EUDET.
Noise & Grounding Andrei Nomerotski (U.Oxford) 17 July 2007.
Progress with GaAs Pixel Detectors
Design and Fabrication
Microwave SQUID multiplexer for the readout of large MMC arrays
Calorimeter Mu2e Development electronics Front-end Review
TriQuint Semiconductor, Inc.
Planar Antenna-Coupled Hot-electron Microbolometer
Large bolometer arrays on radio telescopes.
Some thoughts on readout
Yasuhiro Sugimoto KEK 17 R&D status of FPCCD VTX Yasuhiro Sugimoto KEK 17
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
Why silicon detectors? Main characteristics of silicon detectors:
Presentation transcript:

Netherlands Institute for Space Research Development of TES-microcalorimeter arrays and Frequency Domain Multiplexed read-out Henk Hoevers Division Sensor Research and Technology

Netherlands Institute for Space Research Research Facilities for TES-microcalorimeter array and FDM development Two Kelvinox 100 dilution fridges SQUID channels moveable slit to position X-ray beam (micron resolution) data-acquisition facilities: RT-, IV-curves, analog and digital pulse processing X-ray sources: 5.9 keV and 1.5/2.2/3.0/3.3/5.9 keV In-house clean room -> short turn-around times for detector research class processing on 4” wafers, sputter deposition, thermal evaporation, spinners, mask aligners, wire bonders, inspection equipment Staff Physicists: 6 fte (senior) scientists Electronics: 2.5 fte (senior) design engineers Support staff: 2.5 fte (mechanical, electronical, lab assistant) Clean room staff: 3 full-time persons

Netherlands Institute for Space Research Funding of TES-microcalorimeter array and FDM development SRON staff from NWO income (Dutch Organization for Scientific Research) ESA TRP contract ‘Cryogenic Imaging Spectrometer’ (XEUS – NFI2) SRON TES-based arrays (thin film processing, testing), prime contractor MESA+, Twente University, the Netherlands micromachining development VTT Automation Technology, Espoo, Finland SQUID development Space Research Center, Leicester, UK detector packaging, pulse processing University of Jyvaskyla, Finland material parameters at sub-Kelvin temperatures Metorex, Espoo, Finland electrical crosstalk simulations (dense wiring) SRON and partners will tender on X-10 (expected ESA TRP on array read-out)

Netherlands Institute for Space Research Set-up of the talk TES microcalorimeter array development Status of Frequency Domain Multiplexing Outlook area: energy resolution

Netherlands Institute for Space Research Microcalorimeter array development for XEUS; approach 1) development of 5 x 5 pixel array with XEUS specification 2) address/investigate scalability from 5 x 5 array to 32 x 32 array Production: fabrication of prototype 5 x 5 arrays following two routes bulk micromachining surface micromachining Performance characterization of 5 x 5 pixel arrays R(T), I(V) curves and their reproducibility noise and energy resolution Detector (re)design (5 x 5 -> 32 x 32) uses performance (and understanding) of 5 x 5 arrays additional measurements of all relevant low-temperature material parameters development of a Finite Element Model of the 5 x 5 array (thermal design) The Finite Element Model is also suited for performance analysis (time dependent pulse modeling) and investigation of other pixel sizes and/or geometries

Netherlands Institute for Space Research Bulk and surface micromachining (SRON-MESA); the 5 x 5 arrays TiAu TES (100 mK) and Cu absorber on slotted SiN membrane 240 μm

Netherlands Institute for Space Research R(T) and I(V) curves Bulk MM Three pixels in the same array Bulk MM Three pixels in different arrays/chips Surface MM Three pixels in the same array

Netherlands Institute for Space Research Bulk micromachining; pulse performance/energy resolution Effective time constant: τ eff = 300 to 400 μs This is times lower than expected (and what was designed for) Thermal conductance of SiN/Si(110) is times lower than of SiN/Si(100) Measured energy resolution ∆E = eV at 6 keV Resolution not understood; from the measured noise eV is expected Note: the best single pixels have ∆E = 3.9 eV and τ eff = 85 μs

Netherlands Institute for Space Research In progress: Bi-absorber arrays (7 μm thick with Cu bottom/thermalisation layer) Mushroom shaped absorbers: thermal evaporation and lift-off Problems encountered for XEUS sized pixels (240 x 240 μm 2 ) in 5 x 5 arrays: lift-off edges, particle-like anomalies, μ-cracks in Bi 5 x 5 array Bi absorbers Hat: 240 x 240 μm 2 Stem: 100 x 100 μm 2 Single pixel Bi-absorber Hat: 160 x 160 μm 2 Stem: 100 x 100 μm 2

Netherlands Institute for Space Research Advanced detector design through Finite Element Modelling (2D, 3D) Basic layout of a sensor pixel Measured and modelled thermal transport el-ph coupling in TES and absorber Kapitza coupling between TES - SiN conductance silicon nitride membranes conductance Si support beams thermal coupling of Si chip to heat bath Measured and modelled thermal transport el-ph coupling in TES and absorber Kapitza coupling between TES - SiN conductance silicon nitride membranes conductance Si support beams thermal coupling of Si chip to heat bath 5 x 5 pixel array 32 x 32 pixel array Material parameters and Finite Element Modeling

Netherlands Institute for Space Research Thermal coupling of detector pixels to heat bath Bare Si chip T chip = 187 mK T Si beam = 200 mK Cu coating back-side Si-chip T chip = 41 mK T Si beam = 140 mK Cu coating on Si beams and chip T chip = 41 mK T Si beam = 47 mK Finite Element Model of the XEUS array (1000 pixels of 10 pW each) Improvement of coupling to heat bath and a small thermal gradient in Si beam: proper heat bath Improvement of coupling chip to bath Future XEUS 32 x 32 pixel array SiN Si-beam Beam with Cu side view Si(110) beam Si-beam with Cu SiN Uncoated Si

Netherlands Institute for Space Research Array development - summary Array production based on bulk and surface micromachining The pixel to pixel performance in BMM and SMM arrays is quite good (R(T), I(V)) Thermal conductance of SiN on Si(110) is lower than expected -> τ eff too high To be measured: pixels with redesigned thermal support Improvement of ΔE from eV to values smaller than 5 eV needed Working on reduced sensitivity of set-up for EMI Working on more fundamental issues of the energy resolution Development of large mushroom-shaped absorbers is critical and has high priority The XEUS detector chip and pixels can be adequately cooled Detailed Finite Element Model is available for thermal design, all relevant low-temperature material parameters measured

Netherlands Institute for Space Research Frequency Domain Multiplexing - Motivation for multiplexed read-out Thermal aspects related to the read-out and biasing of one pixel Power dissipation: 10 pW/pixel Power dissipation; 100pW/shunt resistor Power dissipation: 1 nW/SQUID current amplifier Heat input through wiring (5 at minimum, 4 twisted-wire pairs preferred) Available cooling power XEUS ADR: mK 32 x 32 pixel array without multiplexing: only ~4 hours of operation!

Netherlands Institute for Space Research Frequency Domain Multiplexing AC-biasing of TES microcalorimeter TES acts as AM-modulator LC noise blocking filters One SQUID per column

Netherlands Institute for Space Research Need for loop gain Large dynamic range required (current pulse vs current noise) DR = = Φ 0 /(2Φ SQUID ) (1+L FLL ); low-noise VTT SQUID: L FLL > 1.4 Common impedance (SQUID input coil) leads to cross talk (from f 1 to f 2 ) CT = = [L c /(1+L FLL )/L]2; L FLL > 10 The SQUID is an non-linear component -> mixing products (from f 1 to f 2 ) CT = requires L FLL > 15

Netherlands Institute for Space Research Limitations of the achievable loop gain Phase rotation due to cable delay imposes: t delay.f operation < 0.11/L F; For an optimized cryostat with 20 cm distance between SQUID and warm electronics (t delay = 3 ns) Phase rotation of the amplifier (simulation performed for a 200 MHz amplifier with one pole zero compensation) Standard FLL Combining 32 channels (with 100 kHz seperation) requires 3 MHz L FLL ~ 3 MHz It requires very close packing and the available low loop gain is low; it implies an appreciable fraction of mixing products Baseband feedback The carrier is deterministic and carries no information (use it in the feedback) In principle, only the signal bandwidth (200 kHz) is relevant; it allows for high loop gains L FLL ~ 200 kHz

Netherlands Institute for Space Research Standard FLL Pro:Con: FLL proven concept- A-linearity in SQUID introduces crosstalk at 0.2% level - Common impedance leads to crosstalk at 0.4% level - Bandwidth limited to ~3 MHz, 32 close packed channels

Netherlands Institute for Space Research Pro:Con: L > 200 results in:Complex demux/mux electronics A-linearity in SQUID: crosstalk at < 0.01% level Idle-current cancellation not required Available bandwidth is up to ~10 MHz; allows for well-spaced carriers -> cross-talk due to common impedance is no longer a problem Baseband feedback

Netherlands Institute for Space Research Experimental status Frequency Domain Multiplexing (biasing of detectors) Biasing of microcalorimeter AC-bias measurements at 500 kHz to study potential switch-off behavior Microcalorimeter can be biased over the whole transition provided that the there is a small impedance in the biasing circuit low dielectric loss in C Set-up for 250 kHz FLL operational and optimized Electronic resolution of FLL electronics, bias sources and mixers/de-mixers, and SQUID for detector biased in normal state is at present 2 eV Tests with a TES microcalorimeter with 5 eV 6 keV (DC) AC-bias experiment at 50 kHz with keV Baseline noise 5 eV (~sensor dominated resolution) AC-bias experiment at 500 kHz with keV SQUID back-action noise (L SQUID ) limits resolution of 8-9 eV AC-bias experiment at 250 kHz with 7 6 keV Baseline noise eV (sensor dominated resolution)

Netherlands Institute for Space Research Status Frequency Domain Multiplexing (noise blocking filters) LC filters required with Q ~2500 (depends on carrier frequency) Washer-type superconducting coils Minimize dimensions (reduce intercoil cross-talk) Superconducting capacitors High dielectric constant (small components) Low dielectric losses (tan δ < 0.001; introduces resistance) Si 3 N 4 (VTT): Q = 2800 (compatibility of Si 3 N 4 process) Al 2 O 3 (SRON): Q = 300 (limited by critical current) Test structures: 2.4 to 240 nF; size up to 4 x 4 mm 2 Low leakage, R ~ 1 mΩ L = 100 nH 500  m

Netherlands Institute for Space Research Outlook area: energy resolution ΔE = 2.35 ξ [k B T 2 C] 1/2 Microcalorimeter physics Low heat capacity absorbers What motivates the improvement of ΔE? there is still very limited margin on ΔE with respect to the specification for XEUS and other applications the development of large area pixels with a good ΔE requires that ξ and/or C are as low as possible (and under control)

Netherlands Institute for Space Research Outlook – summary Detector physics – improvement of energy resolution (design: 1 – 1.5 eV) Typical energy resolution (measured)4 - 5 eV Possible improvement pulse filtering factor 1.5 – 2(Fixsen method) Possible improvement by ITFN reduction factor 1.5 – 2(TES with lower R N ) Device testing (single pixels and arrays) Large area pixels Low C materials: Bi, Sn Compatibility with large arrays? Design optimization, thermalization issues: ΔE and ΔE_xy (position dependence) Production Device testing (single pixels and arrays), E < 6 keV Absorber development