PF Coils Quench Protection Design of EAST Superconducting Tokamak Oct. 5, 2005 PF power supply team Institute of Plasma Physics,Chinese Academy of Sciences.

Slides:



Advertisements
Similar presentations
Electricity Chapter 13.
Advertisements

Chapter 9 Capacitors.
Inductance Self-Inductance RL Circuits Energy in a Magnetic Field
Safety / Intro The mains supply and batteries are sources of Electrical Energy Electrical Appliances are Energy Changers.
Chapter 12 Transformers. Chapter 12 Transformers.
CHAPTER TWO POWER SEMICONDUCTOR DIODES AND CIRCUITS DESIGNED BY DR. SAMEER KHADER PPU “E-learning Project”
Power Supply System John Joseph LBNL Spectrometer Solenoid Test Plan Review Feb 17 th 2012.

SMAW Equipment (Shielded Metal Arc Welding- commonly called “stick welding”, or “arc welding”)
Chapter 20 Electricity. Section 1 Electric charge and static electricity.
Inductors1 ELECTROMAGNETIC INDUCTION All conductors that carry a current produce a magnetic field As the magnet is moved in and out of a coil of wire in.
SELF INDUCTION DURING AC FLOW, MAGNETIC FIELD IS NOT CONSTANT. AN OPPOSING ACTION WITHIN THE COIL IS PRODUCED.
Circuit Protection  Protective Devices – terminate current flow in a circuit.  Located in series within a circuit  Excessive current flow results from.
Week 3 Electrical Circuits and Components. It’s a Radio!
Alternating Current Circuits
Department of Electronic Engineering BASIC ELECTRONIC ENGINEERING Transients Analysis.
CAPACITOR AND INDUCTOR
Department of Electronic Engineering BASIC ELECTRONIC ENGINEERING Transients Analysis.
EE 369 POWER SYSTEM ANALYSIS
Lecture - 4 Inductance and capacitance equivalent circuits
DC Motor Drives Dr. Ahmad Harb.
EGD ELECTRICAL ELECTRICAL SYMBOLS.
CIRCUIT TYPES PHYSICS UNIT E. CIRCUITS Need a source of energy, a pathway for electrons, and something that uses energy. Ex) Sources: Battery, 120 V plug,
Series vs. Parallel Circuits Physics Mrs. Tobler.
Main article: Leakage inductance
Engineering Practice Electric Fitting Resistance Electrical resistance is the ratio of voltage drop across a resistor to current flow through the resistor.
Electricity and Magnetism Chapters 11 and 12 Central High School Physical Science.
9/27/2004EE 42 fall 2004 lecture 121 Lecture #12 Circuit models for Diodes, Power supplies Reading: Malvino chapter 3, Next: 4.10, 5.1, 5.8 Then.
Single Phase Transformer
1. What type of voltage is supplied by a rectifier?
Electric Current Electrical current is the flow of electrons. Unlike static electricity, charges are in motion. Two types of Current I. Direct current.
Chapter 19: Electric Charges and Currents
Chapter 7 AC Power Analysis
NSTX Centerstack Upgrade: initial discussions of the Machine Protection System (MPS) Robert Woolley 4 November 2009.
Electric Circuits Series and Parallel Circuits. Light a bulb  You are given: Wires, a bulb and a battery. Your job is to: Light the bulb.
Superconducting IR Magnets CHEN, Fusan May 11, 2007.
EET 103 Transformer Chapter 5 1. A transformer is a device that changes ac electric energy at one voltage level to ac electric energy at another voltage.
Determine the mathematical models that capture the behavior of an electrical system 1.Elements making up an electrical system 2.First-principles modeling.
35 Electric Circuits Electrons flow from the negative part of the battery through the wire to the side (or bottom) of the bulb through the filament inside.
MICE Power Supply System John Joseph LBNL Spectrometer Solenoid Controls & Monitoring Review Dec 11 th 2012.
VOCABULARYOBJECTIVES  Parallel circuit  Kirchoff’s current law  Short circuit  Describe how current divides in a parallel circuit  Determine the voltage.
An inductor is a wire coil usually wrapped around an iron core
Electric Circuits. Electric circuit: a complete path from the positive terminal to the negative terminal.
FRESCA II dipole review, 28/ 03/2012, Ph. Fazilleau, M. Durante, 1/19 FRESCA II Dipole review March 28 th, CERN Magnet protection Protection studies.
Self Switching Power Supply. Introduction Self Switching Power Supply  Embedded system requires a regulated power supply.
Electricity and Electromagnetism. What is Electricity? Electricity is a form of energy resulting from charged particles.
Tiina Salmi and Antti Stenvall, Tampere University of technology, Finland FCCW2016 Roma, April 13 th, 2016 Quench protection of the 16T dipoles for the.
Chapter 9 CAPACITOR.
SC Undulators protection and commissioning W. Venturini Delsolaro Acknowledgements: R. Denz, R. Maccaferri.
Transformers and Impedance. Review Two types of current: –ac –dc Two fundamental principles: –Moving electrons create magnetic fields –Moving or changing.
TECHNOLOGIES ESO 4 UNIT 1: ELECTRICITY AND ELECTRONICS ANALOGIC ELECTRONICS (PART 1)
Electricity. TYPES OF CIRCUITS Individual electrical circuits normally combine one or more resistance or load devices. The design of the automotive electrical.
Parul Institute Of Technology Name Of Subject:-Electrical Machines Name Of Faculty:-(1) Suresh Sahoo (2) Yogendra Tiwari E&C 3 rd Sem. Prepaid By :- Sr.No.NameEnrolment.
Electrical Current & Circuits. Components of an electrical circuit Source of electrical energy (battery) A conductor of electrical energy (wire) Device.
CHATS-AS 2011clam1 Integrated analysis of quench propagation in a system of magnetically coupled solenoids CHATS-AS 2011 Claudio Marinucci, Luca Bottura,
Chapter 6: Voltage Regulator
PS-6.9: compare the functioning of simple series and parallel electrical circuits PS-6.10: compare alternating current and direct current in terms of the.
BASICS OF ELECTRONICS.
Power Supply and Energy Extraction System for the CBM magnet
INDUSTRIAL ELECTRONICS/ELECTRICITY
Inductance and Capacitance Response of First Order RL and RC
D1 and D2 powering and protection
Different Types of Relays.
Powering the LHC Magnets
CH 5 – Electricity and Magnetism
Power Supply and Energy Extraction System for the CBM magnet
Chapter 7 – Response of First Order RL and RC Circuits
COOLING OF POWER DEVICES
23.2 Applications of Circuits
Physics Circuit Types.
Presentation transcript:

PF Coils Quench Protection Design of EAST Superconducting Tokamak Oct. 5, 2005 PF power supply team Institute of Plasma Physics,Chinese Academy of Sciences Hefei Anhui P.R.China ASIPP EAST

ASIPP PF Coil Distribution The whole EAST PF magnet system consists of 14 coils, among them PF1 to PF6 are the CS coils, PF7 to PF10 are the diverter coils, and PF11 to PF14 are the PF big coils. They located symmetrically around the equatorial plane

ASIPP PF Coil current in EAST operation

ASIPP The connection between PF coils and PFPS The PF system consists of 14 upper and lower SC coils around the plasma in the EAST tokamak, due to the series connection in diverter, 12 set of PFPS is essential.

ASIPP Parameter for PF Magnet and Plasma Operation Nominal cycle period2800 s PF magnetization20 s PF dwell time to keep magnetization20 s Plasma initiation0.06 s Plasma current ramp up4 s Maximum plasma flat top1000 s Plasma current ramp down4 s

ASIPP PF Coil Parameters and Requirements Tab. 1 EAST PF magnet parameters Rated current15kA Excited time20s Voltage (terminal to terminal)10000V Voltage (magnet to ground)10000V Limited heat condition 5.1  10 8 A 2 s Quench protection delay1s Self inductance17.6~129.5mH Mutual inductance0.33~ 21.6mH Storage energy in operation42MJ (max. 140MJ)

ASIPP The power supply circuit of EAST PF coil

ASIPP The requirements of quench protection ★ to discharge the magnets in such a way that is less than a prescribed limit under all conditions; ★ to limit the maximum instantaneous voltages imposed on the magnet (terminal to terminal, and terminal to ground); ★ to ensure successful discharge with a prescribed reliability for a given number of events over the design lifetime.

ASIPP QP Feature for PF Coil ★ Frequent switching off. the high current rate, and plasma disruption in operation, The PF coil has possibly more quench, ★ strong coupling. The 12 pairs of coil have strong decoupling in each other, in QP the coil energy dissipation will be different from single coil. ★ Positive and negative current. in PF coil,it is important for QP design to use artificial current zero technology ★ High power in input power supply. In PF magnet system, the primary power supply usually is quite high voltage, therefore it is necessary to suppress the input power supply in QP

ASIPP PF Coil Storage Energy

ASIPP PF Coil Storage Energy for Each energy

ASIPP 不同运行方式下各线圈最大储能 ( MJ ) 托卡马克运 行方式 \ 线圈 号 1,21,2 3, 45, 67,89,1011,1213,14 大拉长运行 大截面运行 大体积运行 最大能量

ASIPP QP System configuration The QP consists of bypass, DCCB, PB, fuse, resistor

ASIPP QP Operation Scenario ★ Bypass primary PS. Upon command, the quench protection system will suppress the power supply, close the bypass CU3. ★ Open DCCB. open the DCCB1, after 100ms, and open DCB2. ★ Open PB. If the current detected by sensor DCCT after 200ms is not zero, the pyrobreaker PB will open. ★ Fuse melt, and Energy is dissipated in R. The current flowing through the magnet then follows the circuit through CU3, R and L, and the majority of the energy is deposited in R.

ASIPP DC Current Breaker Rated voltage1.5kV Rated current15kA Max. breaking current50kA Max. breaking voltage3.0kV Closing time110ms Switching time30ms Operation numbers10 4 times Weight210kg

ASIPP Current and voltage curve for DCCB test B– breaker current ; C– arc voltage

ASIPP Backup Breaker--PB Rated current20kA Max. breaking voltage2.0kV Max. voltage10kV Breaking time100µs weight110kg

ASIPP Discharge Resister and Fuse The QP in each power supply will work during the quench of any PF coil. Therefore the PF QP system consists of 12 R-L branches that have magnetic coupling, the total maximum energy E max stored in all coils should be dissipated in these resistor R of each QP. In R design it is necessary to consider whole energy transfer and max. energy storage in each PF coil and different operation time

ASIPP Fuse Pay attention: ★ at high current, melt rapidly ★ at low current, melt longer ★ shunt current from parallel switch ★ Suitable fuse parameter match with SC magnet heat condition. ★ two diodes in opposite parallel are in series with fuse CurrentMelting time 400ANot melt 1000A850s 2000A80s 5000A0.8s 15000A0.01s

ASIPP Coil Current in Quench protection 5s /elongation

ASIPP Coil energy in Quench protection 5s /elongation

ASIPP I 2 t in Quench protection 5s /elongation

Control Unit for QP ASIPP QP controllers consist of two parts: one is hardware controller realized by electronic circuit and relay; others is software controller realized by realtime operation system and industrial computers. Up commands …

ASIPP Parts of PF power supply equipment (7)