Apex Target Marco Oriunno, April 23, 2014. 2 Design and fabrication by: Marco Oriunno, Dieter Walz, Jim McDonald, Clive Field, Douglas Higginbotham, and.

Slides:



Advertisements
Similar presentations
Matt Rooney RAL The T2K Beam Window Matt Rooney Rutherford Appleton Laboratory BENE November 2006.
Advertisements

Heat Transfer to Solids in a Flowing Fluid
The Current T2K Beam Window Design and Upgrade Potential Oxford-Princeton Targetry Workshop Princeton, Nov 2008 Matt Rooney.
Thermoforming Process
Radiopharmaceutical Production Target Foil Characteristics STOP.
UNIT 13 : HEAT 13.1 Thermal Conductivity 13.2 Thermal Expansion.
Interim Design Amy Eckerle Andrew Whittington Philip Witherspoon Team 16.
Current and Resistance JH
Longitudinal Expansion of RFQ Vane Ends at Section-to-Section Interface.
MECHANISM OF HEAT TRANSFER Mode of Heat transfer Conduction Convection
Position [ mm ] Wire Current [ uA ] Results For the 1 mm solid wires, tungsten with the highest melting.
MuCool Absorber Review meeting FermiLab, Chicago 21 – 22 February 2003 Fluid Flow and Convective Heat Transfer Modelling by Wing Lau & Stephanie Yang Oxford.
High Power Hg Target Conceptual Design Review Hg Target Interface with Solenoid V.B. Graves P.T. Spampinato T.A. Gabriel Oak Ridge National Laboratory.
 Stephen Brooks / UKNF meeting, Warwick, April 2008 Pion Production from Water-Cooled Targets.
CHE/ME 109 Heat Transfer in Electronics
Performance of the DZero Layer 0 Detector Marvin Johnson For the DZero Silicon Group.
T. Horn, SHMS Optics Update SHMS Optics Update Tanja Horn Hall C Users Meeting 31 January 2009.
IBL Mock Up IBL Mock Up MANUFACTURING 2011/04/29 François-Xavier NUIRY Maxence CURDY Andrea CATINACCIO CERN PH/DT/PO 1.
CDC Scrutineer Talk Elliott Wolin GlueX Collaboration Meeting Jefferson Lab 9-Sep-2004.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
1 Proposal for a Multi-Optical Transition Radiation System in ATF2 A. Faus-Golfe, D. McCormick IFIC – SLAC 11 June th TB/SGC Meeting.
Electrostatic Septum For AGS C. Pai Brookhaven National Laboratory Collider-Accelerator Department
Calorimeter Analysis Tasks, July 2014 Revision B January 22, 2015.
Design of electrostatic septum for slow extraction from J-PARC main ring 2005, March 2nd ICFA septa workshop 2005 Acc. Lab., KEK M. Tomizawa, Y. Arakaki,
ATLAS Calorimeter Argon Gap Convection Test Bed Brian Cuerden 24 Apr
HPS Collaboration Meeting JLAB, May Tracker Design Status M.Oriunno, SLAC.
Mechanical Status of EUDET Module Marc Anduze – 05/04/07.
Position of the target cell A strange peak in the distribution of e + e - vertices and thoughtless alignment of the target 22 Aug H. Kanda.
NuMI NBI03 November 7-11, 2003 FNAL thin beam windows Jim Hylen / FNAL Page 1 FNAL experience with thin beam windows Issue is: Survival of window in high.
BTeV Pixel Substrate C. M. Lei November Design Spec. Exposed to >10 Mrad Radiation Exposed to Operational Temp about –15C Under Ultra-high Vacuum,
ATLAS Calorimeter Argon Gap Convection Test Bed April 25,
Heat load of the radiation cooled Ti target of the undulator based e+ source Felix Dietrich (DESY, TH-Wildau),Sabine Riemann(DESY), Andriy Ushakov(U- Hamburg),
Calculation of Beam loss on foil septa C. Pai Brookhaven National Laboratory Collider-Accelerator Department
THERMAL ANALYSIS SUMMARY FOR LBNE-BLIP IRRADIATION TESTS P. Hurh 2/19/2010.
ILC MDI workshop January 6-8, 2004 PEP-II IR M. Sullivan 1 Interaction Region of PEP-II M. Sullivan for the ILC MDI workshop January 6-8, 2005.
PCAL Strips light transmission properties April 25, 2011April 26, 20111April 27,
IP instrumentation configuration for Autumn 2010 ATF2 runs Toshiyuki OKUGI, KEK 2010 / 7/ 1 10 th ATF2 project meeting.
Multi-OTR Status A.Faus-Golfe, J.Alabau, C.Blanch, J.V.Civera, J.J.García Garrigós IFIC (CSIC-UV) D.McCormick, G.White, J. Cruz SLAC aand KEK team.
Ch26
Parameters of the NF Target Proton Beam pulsed10-50 Hz pulse length1-2  s energy 2-30 GeV average power ~4 MW Target (not a stopping target) mean power.
Vacuum Studies of LHCb Vertex Locator Sensors Gwenaëlle Lefeuvre, Ray Mountain, Marina Artuso Department of Physics, Syracuse University Abstract : The.
Marc Anduze – CALICE Meeting – KOBE 10/05/07 Mechanical R&D for Technological EUDET ECAL Prototype.
NUMI Flexible Joint/Floating Clamp WBS Power Supply System Level 3 Manager Nancy Grossman FNAL July 10, 2001.
Electron Spectrometer: Status July 14 Simon Jolly, Lawrence Deacon 1 st July 2014.
C osmic R Ay T elescope for the E ffects of R adiation CRaTER Thermal Analysis Huade Tan 6/27/05.
Slide 1 DNB Aperture Preconceptual Design.ppt Preconceptual Design of DNB Collimating Apertures Steve Scott April 28, 2003.
ILC Main Linac Superconducting Quadrupole V. Kashikhin for Superconducting Magnet Team.
ATF2 Magnets ATF2 Magnets 14 Sep 2007Cherrill Spencer, SLAC. Cooling Solid Wire Sextupoles 1 Report of the effort to cool an old FFTB solid wire sextupole.
BNL neutrino beam. Optimization and simulations Milind Diwan June 10.
Simulation of heat load at JHF decay pipe and beam dump KEK Yoshinari Hayato.
Technical Design for the Mu3e Detector Dirk Wiedner on behalf of Mu3e February Dirk Wiedner PSI 2/15.
ESS wire scanner Benjamin Cheymol
GOAL: To understand the physics of active region decay, and the Quiet Sun network APPROACH: Use physics-based numerical models to simulate the dynamic.
Marc Anduze – EUDET Meeting – PARIS 08/10/07 Mechanical R&D for EUDET module.
EUDET HCAL prototype; mechanics Felix Sefkow Work by K.Gadow, K.Kschioneck CALIC collaboration meeting Daegu, Korea, February 20, 2009.
Date of download: 10/14/2017 Copyright © ASME. All rights reserved.
National Research Center” Kurchatov Institute”
Structure and etc Shoji Uno (KEK) at B2GM
Thermoforming Process
Date of download: 12/25/2017 Copyright © ASME. All rights reserved.
Chapter 8 : Natural Convection
Atlas Calorimeter with LN2 Cooling Loops, Revision B
Acrolab Ltd. – Copyright 2003 – Improving Processing of Rubber
Atlas Calorimeter with LN2 Cooling Loops
Chapter 27 Problems 1,11,12,15,16,22,32,33,36,49,56.
Heat transfer Chapter 7.
Hall C Users Meeting 31 January 2009
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

Apex Target Marco Oriunno, April 23, 2014

2 Design and fabrication by: Marco Oriunno, Dieter Walz, Jim McDonald, Clive Field, Douglas Higginbotham, and many others…

Beam parameters assumed 40 µA Vertical width 400 µm Horizontal width 400 µm Vertical dither 5 mm Horizontal dither 1.5 mm. Requirements 3

Beam direction General Layout 1.First Row (from the top) Carbon foils 100um, calibration of the spectrometer with wide angle pion. The first foil is probably BeO. 2.Second Row: Wires H/V for low current beam position and angle scanner. 3.Third Row: Tungsten Foil 15um (more stable that Tantalum). More foils downstream increase the Rate. 4

10 layers of 15 µm thick tungsten ribbons (4.3% rad length) 2.5 mm wide in X Separated by 5.5 cm along beam - Tracks from A´ decays produced in a ribbon, and going into the spectrometers, will not be intercepted by the next ribbon Production target: 5

6

At 40 µA, the target will become hot! The tungsten will expand - The frames that hold the tungsten have enough spring to maintain the ribbons under tension, even when hot. The hot tungsten may be much weaker than at room temperature - The temperature range and tension are selected to stay away from breaking point g tension (Verify the tension is still 250 g) Cooling in the beam region is mostly by black-body radiation. Conduction becomes more important at lower temperatures closer to the supports. Numerous calculations of thermal effects and a simulation allowing for temperature dependence of thermal properties:-- Target issues: 7

Peak temp 1300 K Steady State after 20 sec. Temperature Transient (black body radiation only) 8

Across the beam width Temperature Distribution Temp. fairly uniform horizontally across ribbon 9

Elongation 130 µm Thermal Expansion 10

Beam at < 5 µA for alignment work A set of tungsten wires spaced along the length of the target 4 horizontal wires in 5 mm vertical steps, at -25, -10, 10, 25 cm along the beam 3 vertical wires in 0.25 mm horiz steps, at -20, 0, 20 cm along the beam 100 µm diameter tungsten Still gets hot! But not as bad as the production target ribbons. - Still, use similar tensioning technique as for the ribbons g tension Alignment relative to target 11

Peak temp 900 K Tungsten wire Calibration Target - Heating 12

Produce copious pion signal 8 foils spaced along the length of the target (-30, -22.5, -15, -7.5, 7.5, 15, 22.5, 30 cm) Target frames are mounted on an aluminum plate Plate is cooled by N2 flow through heat sinks on reverse side Optical targets for use during installation are inserted in the back of the plate, (ruby balls) The wire positions have been surveyed relative to the optical alignment targets. BeO scintillator for beam diagnostics Calibration Target - carbon foils 13

Work that should be done on the target -Visually inspect it -Check that the target ribbons and wires are under adequate tension -Check that the structure is clean enough for vacuum -I believe that one or two of the target ribbons were made of tantalum, the intention being to hedge our bets and see if either metal survived better during special test runs (not carried out). The tantalum was found to be mechanically liable to crack during flexing. ->Decide whether to replace the tantalum with tungsten. 14

15