Design of Ventricular Assist Device Basic Components of VAD 1. Blood pump 2. Controller 3. Power source Two Categories of VAD’s Pump 1. Pulsatile flow.

Slides:



Advertisements
Similar presentations
Introduction to Pneumatic Components Build a Working Pneumatic Circuit
Advertisements

Pneumatic Cylinders Chapter 3.
Landstown High School Governors STEM & Technology Academy
Purpose Body Making module is designed for bending the laminated foil film in the shape of a tube, for welding the side seam and for cutting bodies with.
HYDRAULICS & PNEUMATICS
Unit Ten Directional Control Valves
Mechatronics Department Graduation Project II. OutlineIntroduction. Methodology. Mechanical Design. Control Design.
Labyrinth seal into two halves
1 CAUTION: Federal Law (USA) restricts this device to sale by or on the order of a physician. Refer to the “Instructions For Use” for complete Indications.
Compressors CM4120 Julie King.
The End Stage Heart Disease Jennifer Ellis, M.D., FACS The Washington Hospital Center November 9, 2010.
Basics of Pump Vigyan Ashram, Pabal.
Conversion of energy from one form to another Creating useful energy for a certain task Can use any type of energy.
Logic-level outputs can’t drive a motor directly. Solution: Relays –Relays allow one circuit to switch a second circuit –isolates circuit from potentially.
Gas Turbine engines.
Conversion of energy from one form to another Creating useful energy for a certain task Can use any type of energy.
TURBINES.
Actuators.
Sensors and Actuators John Errington MSc. Sensors and Actuators Sensors produce a signal in response to a change in their surroundings e.g. Thermostat.
Air Compressors.
TURBINE & COOLING SYSTEM Presented By – AVIJEET PRATAP 07ME12 IET AGRA
Electrical Fundamentals
Components of Centrifugal pumps
7.3 ENERGY LOSSES AND ADDITIONS  Objective: to describe general types of devices and components of fluid flow systems.
MECH1300 Pneumatic Power Supply Topics Compressor Types Compressor Sizing Vacuum Pumps Chapter 11.
1 Motors and Generators ©Dr. B. C. Paul More Fun with Flux Mechanically Rotated Shaft Slip Rings Wires with brush contacts to slip rings Electromagnetic.
PRESENTED BY : N.SRIKAUSIGARAMAN
 Switches are commonly employed as input devices to indicate the presence or absence of a particular condition in a system or process that is being monitored.
ELECTRO – PROPORTIONAL VALVES
HYDRAULIC MOTORS.
Parul Institute of Engineering & Technology Subject Code : Name Of Subject : Fluid Power Engineering Name of Unit : Pumps Topic : Reciprocating.
PRINCIPLE & CONSTRUCTION OF HYDRAULIC PUMPS
DC Machines and Drives . Books
Transducers – changing one form of energy to another Piezoelectric Microphone Ultrasound Motors/Generators Switches Solenoids Relays EAPs Overview.
Fluid Power Control.
Pneumatics Hydraulics
Submitted by Pradeep pataskar Roll no.11031M02034.
L.J.INSTITUTE OF ENGINEERING AND TECHNOLOGY compressors Shah Aadishkumar Aileshbhai (enrollment no ) (div A roll no. 55) Guided by Mr.hemangsir.
R ECIPROCATING P UMPS Prof. Shrikant M. Harle Dept of Civil Engg PRMCEAM, Badnera.
Positive Displacement Pumps
Prepare by :- Shivkumar Panjabi 1.  Introduction.  Types of compressors.  Positive displacement compressors.  Dynamic compressors.  Reciprocating.
Prepared By Rohit G. Sorte M.Tech
A.D PATEL INST OF TECH. NAME : SETA BHAUMIK D. ( ) TOPIC : CENTRIFUGAL PUMPS FACULTY : BHAUMIK SHETH.
HALBACH ARRAY LINEAR MOTOR ACTUATOR FOR THE TOTAL ARTIFICIAL HEART
Fluid Power Control.
Active Learning Assignment, FFO, BE- Sem 3rd – 2nd year
FLUID POWER CONTROL ME604C. FLUID POWER MODULE:02 ~ HYDRAULIC SYSTEM COMPONENTS.
Principles, Components & Advantages Hydraulic System Created by : Aamir Shaikh Er No
FLUID FLOW FOR CHEMICAL ENGINEERING Dr Mohd Azmier Ahmad Tel: +60 (4) EKC 212 CHAPTER 8 (Part 3) TRANSPORTATION SYSTEM.
CNC FEED DRIVES Akhil Krishnan G M.Tech 1. CONTENTS 1.Introduction 2.Requirements of CNC feed drives 3.Servo motor 3.1 Servo drive control 3.2 Components.
CNC FEED DRIVES.
Linear actuator Cylinders Single acting Double acting
Unit III Class II Pneumatic actuators.
Prepared by: Patel Nirav ( )
Presentation on Actuators.
Chapter Electromechanical Systems 6. Chapter Electromechanical Systems 6.
Optimum Pump Performance for Process Applications
10/11/2011 Ashton Pepple Kyler Sanders
HYDRAULICS & PNEUMATICS
Cylinder Cushioning mechanism
Hydraulics Motor.
CLUTCHES.
Axial and centrifugal continuous-flow rotary pumps: A translation from pump mechanics to clinical practice  Nader Moazami, MD, Kiyotaka Fukamachi, MD,
اندازه گیری جریان سیال.
A course in turbomachinery……………lecturer: Dr.Naseer Al-Janabi
Siavash S. Asgari, MS, Pramod Bonde, MD 
Heart Mate Pump 2 LVAD Patient Stories
A course in Turbomachinery Lecturer: Dr.Naseer Al-Janabi
Classification of air compressors. What are compressors? Compressors are mechanical devices that compresses gases. It is widely used in industries and.
PUMPS AND DRIVERS NCCER
Presentation transcript:

Design of Ventricular Assist Device Basic Components of VAD 1. Blood pump 2. Controller 3. Power source Two Categories of VAD’s Pump 1. Pulsatile flow : rythmic propagation of blood flow 2. Continuous flow

Design of Ventricular Assist Device First Generation VADs - Displacement blood pumps - External control system triggers pumping by a pusher plate or diaphragm mechanism - Pneumatic console used to drive pump, but now have been replaced by implantable electric system - This mechanism provides pulsatile stroke volume - But there’s problem with weight, size, driveline infection and thromboembolism. - e.g. Abiomed BVS®5000, Thoratec, LionHeart

Design of Ventricular Assist Device LionHeart™ VAD - Implantable - Consist of internal components : blood pump, system controller, rechargeable batteries, compliance chamber, internal power coil - Also there are external components : power pack, power transmitter, telemetry wand, charger, battery - No percutaneous leads : - reduction in risk of infection - improved mobility - enhanced quality of life - Pump consist of : - Titanium case with motor - Seam-free polyurethane blood sac - Pusher plate - Unidirectional inlet/outlet mechanical heart valve

Design of Ventricular Assist Device

- Principle operation : - - equipment powered using trancutaneous energy transmission (TET) i.e. wireless power transmission. - - external DC power converted to AC allowing TET. - - external transformer coil will placed over implanted transformer coil.

Design of Ventricular Assist Device

- - implanted power coil produce current to run the motor. - - motor actuates roller screw and pusher plate. - - motor will drive the roller screw mechanism. - - linear motion of screw will results in linear motion of pusher plate. - - pusher plate will compress blood sac. - - compressed blood sac will eject blood from the pump. - - when pusher plate releases, blood will fill the pump. - - LionHeart capable to produce 3-7 L/min of output. - - controller housed in titanium case. - - continuous monitoring of EDV using Hall Effect sensor for control system. - - pump rate automatically adjusted to match the rate of blood filling the sac.

Design of Ventricular Assist Device - - gas-filled compliance chamber ensure constant air pressure inside the pump. - - otherwise it could cause fatigue to motor components. - Technical data: - Pump: size 71×69 mm, weight 680 g, stroke volume 64 ml, flow rate 8 l/min. - Controller: size 102×95×29 mm (length×width×height), weight 500 g. - TET internal coil: size 73×16 mm (diameter×thickness), weight 136 g. - Compliance chamber: size 127×13 mm (diameter×thickness), weight 91 g.

Design of Ventricular Assist Device Novacor® LVA System - - electromechanical vented VAD. - - controller and battery located externally. - - pump design is dual-plate pusher. - - percutaneous lead connecting pump with external component. - - the system can be operated in fixed-pulse rate, synchronous or automatic mode. - - inflow conduit designed to reduce thromboembolic complications. - - vibration damping in pump driving unit. - Technical data Novacor® LVA System: weight 860 g, external volume 400 cm³, stroke volume 70 ml, flow rate 10 l/min.

Design of Ventricular Assist Device

Second Generation VADs - Of rotary pump type i.e. axial flow impeller pumps and centrifugal/radial flow pump. - Provide continuous, non-pulsatile flow. - Electromagnetic mechanism consist of rotor and impeller blades - Advantage of rotary pump over pulsatile flow : - - small size - - fewer moving part - - elimination of compliance chamber or external vent tube - - absence of valves - - quiet operation - - fewer infections and thromboembolic complications - e.g DeBakey VAD, FlowMaker, HeartMate II

Design of Ventricular Assist Device DeBakey VAD® - Axial flow blood pump. - The pump composed of : - - titanium pump housing - - inlet cannula - - rotating inducer impeller - - stationary flow straightener - - percutaneous cable assembly with controller connector - Inducer impeller supported at both ends by double pivot bearings. - Impeller has six blades rotated by electromagnetic force. - Pump driven by DC motor stator contained in stator housing. - Ultrasonic flow probe placed on outflow graft. - Controller module has audible and visual alarms with LCD to display messages.

Design of Ventricular Assist Device

- Technical data: weight 95 g, size 86×25 mm (length×diameter), external volume 37 cm³, flow rate 5-10 l/min, rotational speed ,000 rpm, power requirement 6 W.

Design of Ventricular Assist Device HeartMate II - Axial flow blood pump. - The pump unit has blood immersed mechanical bearings. - External power source connected by abdominal percutaneous electrical lead. - Designed for thrombosis and haemolysis reduction using computational fluid dynamics and laser flow visualization. - Smooth and textured design for blood contacting surfaces to eliminate thrombus at inlet and outlet stator. - Manual or auto mode for rotation speed control. - For auto mode, motor speed control based on characteristics of pump’s head pressure, pump flow and current consumption. - Technical data: weight 350 g, 60x43 mm (lengthxdiameter), external volume 63cm3, flow rate up to 10 L/min, rotational speed rpm.

Design of Ventricular Assist Device

Third Generation VADs - Replacement of mechanical bearings of 2 nd generation by hydrodynamics bearing and/or full magnetic suspension pumps thus allow higher durability and reliability. - In hydrodynamic bearing, rotor partially supported by a film of blood that counteract mechanical loads on pump rotor. - Magnetic suspension(levitation) allow large clearances around impeller and permits optimised flow. - Longer life expectancy (10-15 yrs) since there is no friction effect at contact bearings. - No contact between impeller and static part, thus it is a silent device. - Sensor linked to magnetic bearing provide info on flow rate and pump performance. - e.g. INCOR® LVAD, MicroVAD, MagneVAD, EVAHEART

Design of Ventricular Assist Device INCOR® LVAD - Axial flow blood pump. - Free floating active magnetic bearing stabilize impeller in axial direction. No contacts with other parts - Percutaneous driveline to controller and power pack. - Integrated sensor system to measure pressure of head. - Automatic anti-suction algorithm based on grade of pulsatility of blood flow across pump. - The blood coming from the heart flows into the INCOR® axial pump and first passes the inducer which guides the laminar flow onto the actual impeller. - stationary diffuser behind the rotor has specially aligned blades which reduce the rotational effects of the blood flow and adds additional pressure to assist the transport of the blood in the outflow cannula to the aorta.

Design of Ventricular Assist Device Incor VAD

Design of Ventricular Assist Device VentrAssist LVAD - Centrifugal flow pump. - Contact-free hydrodynamicaly suspended impeller. - Integrated rare earth magnet motor. - designed to have no wearing parts or cause blood damage. - Pump encased in biocompatible titanium alloy shell - weighs just 298 grams (10oz) and measures 60mm (2.5 inches) in diameter

Design of Ventricular Assist Device Classification of VADs 1. Pulsatile flow 2. Continuous flow (or rotary pump) : - axial flow - centrifugal flow - magnetic bearing supported - blood immersed bearing supported - hybrid magnetic/blood bearings Examples of VAD design will be shown :

Design of Ventricular Assist Device Baxtor/Novacor Pulsatile Pumping Mechanism

Design of Ventricular Assist Device - Electromagnetic actuator closes rapidly. - Stores energy by deforming a compliant flexure drives the pump. - Deformed flexure compresses the flexible blood sac to move the blood. Mechanism - Pump sac filled with blood and solenoid is unlatched. - Solenoid closed rapidly at start of pump ejection. - Beam spring defelected through pump pusher plates. - Force exerted on surfaces of blood in pump sac.

Design of Ventricular Assist Device

Nimbus Rotary LVAD - With blood immersed bearing. - Such bearings has high shear rates* - Bearings also might cause blood damage. - Thrombus might be formed around the bearing. Magnetically Levitated Pump - Magnetic bearings with large gaps replace blood immersed bearing. - Impeller supported by passive permanent magnet toward inlet. - Active conical bearing support towards outlet of the pump. *gradient of velocity

Design of Ventricular Assist Device

Medtronic Centrifugal Pump

Design of Ventricular Assist Device - Impeller driven to rotate by external motor and power console. - Impeller’s rotation produces vortexing effect establishing suction in inlet cannula. - Blood enters the pump and ejected tangentially.