PART 3: Breathing Circuit

Slides:



Advertisements
Similar presentations
INHALATION ANAESTHESIA BREATHING SYSTEMS Prepare and monitor anaesthesia in animals INHALATION ANAESTHESIA BREATHING SYSTEMS.
Advertisements

CPAP/PSV.
ANESTHETIC MACHINES.
CARBON DIOXIDE ABSORPTION
Anesthesia Machine Presented by Gil Soto C.R.N.A.
Use of the Inhalant Anesthetic Machines
Respiration. How does respiration take place? There are two respiratory movements: Inspiration (inhalation) Expiration (exhalation) When you inhale, air.
The Mechanics of Breathing
The process of breathing is called RESPIRATION
Check Valves and Manufacturer-Recommended Leak Test
Trigger/Limit/Cycle/Baseline
Scavenging System  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected to a.
Initiating Positive Pressure CMV A generic approach!
Anesthetic Equipment.
Oxygen Delivery Devices they’re not what you think.
 We take about breaths per minute  How many breaths per day?  How many breaths per lifetime?  You take between 500 million to 750 million breaths.
Bird respiration Respiratory structures of birds differ from mammals Birds distinguished by presence of several large thin- walled air sacs And air spaces.
PART 3: Breathing Circuit
Parts of the Anesthetic Machine
Ventilation / Ventilation Control Tests
A). When the carrier gas is quickly switched to 100% nitrous oxide (B). the halothane concentration decreases to 3% within 8 to 10 seconds A new steady-state.
Anesthesia Breathing Systems
Inhaled anesthetic Delivery Systems
Scavenging System A&A Pg 356  To reduce exposure to waste anesthetic gases  Can be active or passive scavenging system Active Scavenging System  Connected.
Endotracheal tubes Made of either rubber, vinyl plastic, or silicone plastic rubber tubes (red color) dry and crack over time with exposure to disinfectant.
+ Surgical Procedures 7.01 Implement techniques to prepare and monitor patients for surgery.
Non-Rebreathing System  Used for patients weighing < 7 kg  Attach the clear, plastic hose to the fresh gas inlet (this tube comes from the vaporizer.
Respiratory Therapy! Just breathe!.
Ventilators All you need to know is….
AMIR SALAH MODERN ANAESTHETIC MACHINE MODERN ANAESTHETIC MACHINE 2 of 4.
Introductory Lecture Series: The Anesthesia Machine
Without reference, identify principles about volume/pressure and high frequency ventilators with at least 70 percent accuracy.
Oxygenation And Ventilation
ANAESTHESIA BREATHING CIRCUITS
8.1 The Task of Respiration
How and why Gas Exchange happens: Location: The alveoli Method: Diffusion.
Lesson 7 – Structure and Processes of Respiratory System
Anesthetic Problems and Emergencies A&A pg Why Do Problems Arise?  Human error  Equipment error  Adverse effects  Patient factors  Anesthetic.
Pulmonary Circulation- THIS IS A REVIEW!!!! ______________ blood enters the lungs from ______ ventricle of heart through the pulmonary ______. Pulmonary.
Human Organ Systems The Respiratory System The Respiratory System.
© SSER Ltd.. The basic breathing rhythm is a reflex action under the control of the nervous system The region of the brain controlling this basic rhythm.
Anesthesia Machine Circuits
These are measured with a spirometer This is estimated, based on
The Respiratory System
The purpose of the breathing rhythm is to ventilate the lungs to allow delivery of oxygen to the alveoli, and elimination of the waste gas carbon dioxide.
Ventilator Management James Eakins, MD FACS Director, Trauma and Surgical Critical Care Hahnemann University Hospital.
Parts of the Anesthetic Machine A&A Pages
11.1 The Function of Respiration
PART 3: Breathing Circuit
The Human Respiratory System
Chapter 6 The Respiratory System and Its Regulation.
Short Term Effects of Exercise Works harder to meet the demands for more O2 Increased Breathing Rate Take more breaths to get more O2 into the CV system.
Intubation and Anesthetic Machines
Introductory Lecture Series: The Anesthesia Machine
BREATHING SYSTEMS.
PRESSURE CONTROL VENTILATION
11.1 The Function of Respiration. Agenda Lesson 11.1 The Function of Respiration Read p Vocabulary Learning Check SG 166 # 1-3, SG 167 #1-3.
PART 3: Breathing System Parts
MACS CPAP System Self Guided Tour.
Non-Rebreathing System
Parts of the Anesthetic Machine Parts 1 & 2: A&A pages
Mechanical Ventilator 2
Non-Rebreathing System
What it Means to Breathe
Breathing Systems Tom Williams.
© SSER Ltd..
© SSER Ltd..
Human Organ Systems The Respiratory System.
Presentation transcript:

PART 3: Breathing Circuit The system that brings the fresh gas from the vaporizer to the patient and takes the expired gases from the patient to the scavenger. May contain unidirectional valves, reservoir bag, pop off valve, CO2 canister, negative pressure relief valve, pressure manometer. Non-rebreathing System Rebreathing System

Rebreathing System Set up as a circle system  exhaled gases are recirculated and rebreathed by the patient New fresh gas is also added in Used for patients weighing >7kg Can be used as a closed or semi-closed system Begins with the fresh gas inlet Vaporizer outlet port connects to the fresh gas inlet, which connects to the inspiratory unidirectional valve

Rebreathing System: Closed Pop-off valve is completely closed! Only provides enough oxygen to meet metabolic demands of the patient Oxygen flow rates (L/min) must be kept very low!! The volume of gas added to the circuit = the volume of gas used by the patient *This is very tricky to achieve and is therefore not commonly used

Rebreathing System: Semi-Closed Also known as partial rebreathing system This is much more common! Pop-off valve is open or partially closed This system requires a scavenging system because more oxygen than the patient needs is being provided

Unidirectional Valves One-way valves that allow the flow of fresh gas to enter the inhalation valve and exit the exhalation valve. Valve is either a rigid disk or a flap that flutters as gas flows past it Inspiratory/Inhalation valve opens as patient inhales Fresh gas enters the inspiratory breathing hose, then the ET tube and then the patient’s lungs Gas exchange occurs now = sleepy patient 02 CO2

Unidirectional Valves CO2 and anesthetic gases are then exhaled and travel up the expiratory breathing hose. Gas flows through the unidirectional exhalation valve This valve prevents the expired gases from traveling back to the patient before the CO2 is removed.

Breathing Tubes for Rebreathing System 1. Y Tubes Come in large animal, small animal, and pediatric Large animal tubes can only be used on large animal machines 2. Universal F-circuit Come in adult (green-blue) and pediatric (red or green) Pediatric = patients 15-35 lbs Adult = patients weight > 35 lbs The inspiratory tube is located within the expiratory tube Each connects to the machine separately at their respective flutter valves  CO2 absorber

F-circuit Y tubing

CO2 Absorber Exhaled gases flow out of the expiratory breathing tube and into the CO2 canister CO2 canisters usually contain calcium hydroxide granules that selectively absorb CO2 from other gases breathed out. Example: soda lime granules “Exhausted” soda lime granules no longer absorb CO2. patient breathes in CO2

HOW DO I KNOW WHEN THE GRANULES ARE EXHAUSTED? CO2 Absorber HOW DO I KNOW WHEN THE GRANULES ARE EXHAUSTED? Color change to violet, off-white or pink depending on the brand. CO2 saturated granules are hard and brittle; new ones can be chipped and crumbled Once color becomes abnormal, it is possible that it changes back to normal within hours! VTI note: Change q 8 hours of use next, gas flows into the rebreathing bag AND through the pop-off simultaneously 

Reservoir Bag- aka rebreathing bag Expandable bag that fills as gases enter the circuit or as patient exhales Deflates as patient inhales Range in size from 0.5 L to 30 L; 1 L increments Volume of bag should be minimally 60 mL/kg *This is equal to 6 times their minimum tidal volume

Reservoir Bag Calculation If your patient weighs 15 lbs, how many mLs of air should the bag hold? How many liters is this? *Always round up to next highest bag *If that size doesn’t work for your patient, switch it out!

Reservoir Bag Functions Helps in determining correct ET tube placement movement of bag with breaths = tube in trachea (yay!) Allows assessment of respiratory rate and depth Good for when you can’t see your patient Why can’t you see your patient?! Allows manual ventilation of the patient Also known as “giving a breath” or “bagging”

Indications for Manual Ventilation Reverse atelectasis if present; prevent if not Done by closing pop-off and gently squeezing bag Performed once q 10 minutes = “sighing” patient Removal of CO2 and anesthetic that builds up when respirations have decreased in volume Anesthetics decrease tidal volume up to 50% Forcing fresh gas in stimulates gas exchange in the alveoli Assist or control ventilation – especially if in respiratory arrest or “deciding not to breathe” IPPV

Is Your Reservoir Bag the Right Size? Bags should consistently be ½ to ¾ full upon exhalation If bag is going from over-inflated to flat = Bag is too small and doesn’t hold enough oxygen  patient won’t be able to fully inflate lungs on inhalation AND Bag will overinflate on exhalation increases pressure in the circuit If bag is flat during respirations (under-inflated) = Bag is too big  will not see movements with each breath and wasted space in circuit

Pressure Manometer Measures pressure of gas within the breathing circuit this includes the patient’s lungs Unit is in cm H20 Should read between 0-2 cm H2O during normal respirations Pressure increases as system is closed How do we close the circle and why? Gauge should never exceed 20 cm H20 in small animals! Watch manometer while “bagging” patient

Pop-off Valve - aka pressure relief valve, exhaust valve Always kept open for semi-closed system Allows exhaled gas to leave the breathing circuit and be scavenged Prevents the build-up of excess gas or pressure within the circuit. If the pressure were allowed to build up (forgot to open pop-off valve), the alveoli in the lungs could rupture!

Pop-off Valve The degree that the pop off valve is opened changes the flow rate and how full the reservoir bag is. (semi-closed system) If you see your reservoir bag unintentionally expanding very quickly- check pop-off! Only close the pop-off valve when you are currently providing breaths for the patient Must be opened between breaths!

Occlusion Valve This one is safety regulated

Negative Pressure Release Valve aka Air Intake Valve Special feature activated in emergencies Indicated by a completely empty reservoir bag 1. When an active scavenging system is utilized, if negative pressure is detected in the circuit, this valve opens and allows room air in. Instances when there is excessive suction 2. O2 flow rate is too low or tank runs out of O2 ALWAYS keep an eye on your oxygen pressure gauge *Better for the patient to breathe room air than no air