Bias and Errors. Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness.

Slides:



Advertisements
Similar presentations
Radiochemical Methods and Data Evaluation
Advertisements

Quality is a Lousy Idea-
Dr. Birgit Schmauser, BfArM, Bonn
Validation of screening methods (2002/657/EC)
Instrumental Analysis
Calibration methods Chemistry 243.
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
Errors in Chemical Analyses: Assessing the Quality of Results
Selectivity, Sensitivity, Signal to Noise, Detection Limit
Quality in Environmental Analysis Tuesday, June 27, 2000 Goldwater Center Room 487.
Result validation. Exercise 1 You’ve done an analysis to the best of your ability using the correct procedure. Is your answer correct? possibly, hopefully.
Chapter 1 Introduction Analytical Chemistry deals with methods for determining the chemical composition of samples. Qualitative Analysis (identification)
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
Basic Questions Regarding All Analytical & Instrumental Methods (p 17-18) What accuracy and precision are required? How much sample do I have available,
Instrumental Methods: Intro  Types of Instrumental Methods  Fundamental Components of an Instrument  Instruments Measure Voltages and Currents! (“Machines”
Biomedical Tracers Biology 685 University of Massachusetts at Boston created by Kenneth L. Campbell, PhD.
Supplementary Training Modules on Good Manufacturing Practice
Types of experimental error
Chemometrics Method comparison
Lecture 1 INTRODUCTION TO INSTRUMENTAL ANALYSIS Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Quality Control In Measurements Tom Colella CLAS Goldwater Environmental Lab.
Validation of Analytical Method
Laboratory Validation of Analytical Methods
CH915: Elemental Analysis
Quality assurance of sampling and analytical instruments
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical considerations
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
Quality WHAT IS QUALITY
Define Problem Select Appropriate Methods Obtain and store sample Pre-treat sample Perform required measurements Compare results with standards Apply necessary.
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
Chapter 5 Errors In Chemical Analyses Mean, arithmetic mean, and average (x) are synonyms for the quantity obtained by dividing the sum of replicate measurements.
Er. J.S. Kamyotra Central Pollution Control Board Ministry of Environment & Forests New Delhi Website: MALE’ DECLARATION ON CONTROL.
ME551/GEO551 Introduction to Geology of Industrial Minerals Spring 2005 SAMPLING.
Quality Assurance How do you know your results are correct? How confident are you?
Data Analysis: Quantitative Statements about Instrument and Method Performance.
Data Analysis and Presentation Chapter 5- Calibration Methods and Quality Assurance EXCEL – How To Do 1- least squares and linear calibration curve/function.
1 Exercise 7: Accuracy and precision. 2 Origin of the error : Accuracy and precision Systematic (not random) –bias –impossible to be corrected  accuracy.
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
Instrumental Methods: Intro
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Lab Skills Recap Biotech II. Metrology Vocabulary Unit of measurement Accuracy Precision Standards Calibration Verification Traceability Tolerance Errors.
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
Errors. Random Errors A random error is due to the effects of uncontrolled variables. These exhibit no pattern. These errors can cause measurements to.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
Chapter 1: Introduction Analytical Chemistry Analytical Chemistry Qualitative analysis Qualitative analysis Quantitative analysis Quantitative analysis.
Quality Control Internal QC External QC. -Monitors a test's method precision and analytical bias. -Preparation of quality control samples and their interpretation.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Chapter 5: Errors in Chemical Analysis. Errors are caused by faulty calibrations or standardizations or by random variations and uncertainties in results.
EQUIPMENT and METHOD VALIDATION
Method Validation of VINDTA 3C (TA/DIC) Marine Scotland Science (MSS) Experience and Concerns Pamela Walsham.
1 Analytical Chemistry II Somsak Sirichai Lectures: Tuesday p.m. Friday a.m. C
Determinations and Interpretations of FTIR Detection Limits
Quality is a Lousy Idea-
The standard deviation (SD) quantifies variability
World Health Organization
Dr. Birgit Schmauser, BfArM, Bonn
Instrumental Methods: Intro
Strategies for Eliminating Interferences in Optical Emission Spectroscopy Best practices to optimize your method and correct for interferences to produce.
Quality is a Lousy Idea-
Chapter 5 Quality Assurance and Calibration Methods
ANALYTICAL METHOD VALIDATION
World Health Organization
Introduction To Medical Technology
Satish Pradhan Dnyanasadhana College, Thane. Department of Chemistry S
▪Internal quality control:
Measurements & Error Analysis
Presentation transcript:

Bias and Errors

Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness

Accuracy and Precision... Before we can appreciate the term Bias, we must first understand the basic terms “accuracy” and “precision”. Accuracy is the closeness of a result to that of an expected value. Consider the following example: –10 µL of each 1 ppm, 5 ppm, 10 ppm, 50 ppm and 100 ppm standards of caffeine standards (USP) are injected into an LC-MS. An external standard calibration curve is generated. –10 µL of a “reference” (NIST traceable) sample containing caffeine of a concentration unknown to us is then injected into the LC-MS. The response, once interpolated from the calibration curve, yields 11 ppm in the sample. –We find out later that the actual concentration of the “reference” caffeine standard is 10 ppm. –Under what conditions should we be concerned about this result? –What are some reasons why this occurred?

...Accuracy and Precision... We must appreciate that the so-called determination of an analyte concentration in a sample is really, at best, an “estimate” of its actual concentration. Associated with every determination is a level of “precision” or “reproducibility”. Consider the following continuing with our caffeine determination: (Note, the red bar is the “true” concentration of the target analyte and is 10 ppm.) ppm 10 measurements, with an average concentration of 10 ppm, yet the range of concentrations is >20% RSD. Accurate Not Precise

...Accuracy and Precision ppm 10 measurements, with an average concentration of 13 ppm and with >20% RSD. Not Accurate and Not Precise ppm 10 measurements, with an average concentration of 11 ppm, yet with <10% RSD. Precise Not Accurate

...Accuracy and Precision ppm 10 measurements, with an average concentration of 10.1 ppm, and with <2% RSD. ACCURATE and PRECISE From this, we can see clues re. BIAS, t-test comparison of means of results using different methods (ANOVA), LOD, LOQ, and even ruggedness.

Bias and Errors Page 12-on and A2-A5 Skoog Holler Nieman BIAS: The systematic departure of the “measured” value from the “true” or “expected” value. There are many sources of BIAS, and they may be additive. Accuracy can be assessed quite simply using certified or standard reference materials that “match” your test standards and samples. –Matrix effects can create artifacts resulting in BIAS, positive or negative. SYSTEMATIC ERRORS can result in BIAS.SYSTEMATIC ERRORS can result in BIAS. A: No BIAS; B: BIAS +ve

Errors... Three basic types: –Instrumental –Method –Personal Overall: Systematic or Determinate Random Mistakes (human errors, or prejudice) Instrumental Errors “Drift” in electronic circuits (e.g., improper zero) Temperature control is unstable is subject to ambient parameters. Poor power supplies, e.g., other instruments on the same power grid perturbing the instrument’s power. Other systems in the area creating a field that influences detector response, coincidentally while the samples are running, but not the standards. Regular calibration is required, the frequency of which is for the most part empirically determined (from actual experiments). In all cases, accuracy is most likely affected

...Errors... Method Errors Often introduced by non-ideal chemical behaviour. Loss of sol’n by evaporation. Analyte losses upon unexpected adsorption or absorption. Contaminants. Interferences (affects selectivity, e.g., electrochemical methods, AA) Instability of reagents. Difficult to detect the target analytes. The solution used to prepare the standards is not the same as the sample matrix. This can be easily accomplished by Standard Addition, Isotope Dilution (deuterated analogues). This is where External Standard Calibration can result in BIAS. Use of CRM (certified reference materials), intra- and inter-laboratory method validation, and verification by other analysts really helps here.

...Errors... Human (Personal) Errors Made unknowingly and sometimes knowingly. Prejudice w.r.t. reading meniscus, thermometers, pH meters, peak integration (apex determinations), colour end points.

...Errors... Sources of BIAS and VARIABILITY in the Lab Sample storage (contamination, physical or chemical degradation) Sample handling (contamination during preparation). Sub-sampling Weighing and volumetric devices Solvent purity Extraction yields - low and/or variable Analyte concentration following evaporation Clean-up steps (analyte losses) Quality of reference standards Instrument calibration Instrumental - injection variability and/or discrimination, matrix effects, changes in detector response during the course of the sample analyses Different analysts Environmental and electrical conditions in the lab (T, RH).

...Errors Assessing BIAS and Variability Use of reference materials Comparison to another method (preferably a standard method) Use of representative blank matrices and spikes Use of true positive samples and spikes, which have been confirmed by other analysts or lab Within-run and between-run variability studies

Comparison to Another Method

Comparison to a Reference Value