Low X-ray background measurements at the Underground Canfranc Laboratory E. Ferrer-Ribas, I. Giomataris, F.J. Iguaz T. Papaevangelou - IRFU/CEA-Saclay.

Slides:



Advertisements
Similar presentations
Beam-plug and shielding studies related to HCAL and M2 Robert Paluch, Burkhard Schmidt November 25,
Advertisements

Beam tests of Fast Neutron Imaging in China L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang 2, X.
Micromegas studies using cosmic rays Franck Sabatié May 7th 2009 Saclay cosmic ray bench Data acquisition system and analysis tools MIP detection Position.
Beijing, August 18, 2004 P. Colas - Micromegas for HEP 1 Recent developments of Micromegas detectors for High Energy Physics Principle of operationPrinciple.
The CAST experiment: status and perspectives Francisco José Iguaz Gutiérrez On behalf of the CAST Collaboration IDM2010-Montpellier 27th July 2010.
Bulk Micromegas Our Micromegas detectors are fabricated using the Bulk technology The fabrication consists in the lamination of a steel woven mesh and.
Activity for the Gerda-specific part Description of the Gerda setup including shielding (water tank, Cu tank, liquid Nitrogen), crystals array and kapton.
Status of Ultra-low Energy HPGe Detector for low-mass WIMP search Li Xin (Tsinghua University) KIMS collaboration Oct.22nd, 2005.
The AMS-02 detector is based on a large acceptance (~0.5 m²sr) and high sensitivity spectrometer composed by a super-conducting magnet (0.8 T), cooled.
Neutron background measurement at LNGS: present status Measurement carried out in collaboration between LNGS ILIAS-JRA1 and ICARUS groups.
X-Ray Fluorescence Analysis by Gergana Hristozova Project supervisor: s. eng. M. Gustova FLNR.
WP2: Detector development Summary G. Pugliese INFN - Politecnico of Bari.
Experimental Area Meeting V. Bobillier1 Good connection to earth (in many points) of every metallic parts to be installed in the cavern is very.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Lee, Myeong Jae DMRC, Seoul national university
I. Giomataris Large TPCs for low energy rare event detection NNN05 Next Generation of Nucleon Decay and Neutrino Detectors 7-9 April 2005 Aussois, Savoie,
Status of DRIFT II Ed Daw representing the DRIFT collaboration: Univ. of Sheffield, Univ. of Edinburgh, Occidental College, Univ. of New Mexico Overview.
CRESST Cryogenic Rare Event Search with Superconducting Thermometers Max-Planck-Institut für Physik University of Oxford Technische Universität München.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
Annual Modulation Study of Dark Matter Using CsI(Tl) Crystals In KIMS Experiment J.H. Choi (Seoul National University) SUSY2012, Beijing.
Cryogenic particle detection at the Canfranc Underground Laboratory First International Workshop for the Design of the ANDES Underground Laboratory Centro.
Status of the NO ν A Near Detector Prototype Timothy Kutnink Iowa State University For the NOvA Collaboration.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
Search for Solar Axions: the CAST experiment at CERN Berta Beltrán (University of Zaragoza, Spain) ASI Spin-Praha-2005 Prague, July 2005
ICHEP / 24 Status Report of CERN Axion Solar Telescope (CAST) Experiment Dieter H.H. Hoffmann (Tech. University Darmstadt & GSI – Darmstadt) on.
Design and development of micro-strip stacked module prototypes for tracking at S-LHC Motivations Tracking detectors at future hadron colliders will operate.
Large TPC Workshop, Paris, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay.
Lab tests of Thick GEMs (THGEM) Lab tests of Thick GEMs (THGEM) S. Dalla Torre, Elena Rocco, L. Ropelewski, F. Tessarotto May – August 2007.
Status of Surface Sensitive Bolometers University of Insubria – Como, Italy INFN – Milano, Italy Prague, Chiara Salvioni.
Diego Gonzalez Diaz (Univ. Zaragoza and CERN)
Underground Laboratories and Low Background Experiments Pia Loaiza Laboratoire Souterrain de Modane Bordeaux, March 16 th, 2006.
Piggyback seal Micromegas D. Attié, A. Chaus, D. Durand, D. Deforges, E. Ferrer Ribas, J. Galán, I.Giomataris, A. Gongadze, F.J. Iguaz, F. Jeanneau, R.
Neutrinos are tiny, neutral, elementary particles which interact with matter via the “weak force”. The Sun produces over two hundred trillion trillion.
Update on the Triple GEM Detectors for Muon Tomography K. Gnanvo, M. Hohlmann, L. Grasso, A. Quintero Florida Institute of Technology, Melbourne, FL.
I. Giomataris NOSTOS a new low energy neutrino experiment Detect low energy neutrinos from a tritium source using a spherical gaseous TPC Study neutrino.
G4 Validation meeting (5/11/2003) S.VIRET LPSC Grenoble Photon testbeam Data/G4 comparison  Motivation  Testbeam setup & simulation  Analysis & results.
DEAR SDD --> SIDDHARTA
VIeme rencontres du Vietnam
Tracking (wire chamber) Shield radon, neutron,  Source foil (40 mg/cm 2 ) Scintillator + PMT 2 modules 2  3 m 2 → 12 m 2 Background < 1 event / month.
Muon and Neutron Backgrounds at Yangyang underground lab Muju Workshop Kwak, Jungwon Seoul National University 1.External Backgrounds 2.Muon.
1 GEM R&D Activity in USTC Yi Zhou University of Science & Technology of China.
Radioactive source and cosmic-ray test for the MWPC Davide Pinci on behalf of the Frascati-Roma1 MWPC group.
? At Yangyang beach, looking for something in the swamp of particles and waves. 1 The recent results from KIMS Seung Cheon Kim (Seoul National University)
Results of the NEMO-3 experiment (Summer 2009) Outline   The  decay  The NEMO-3 experiment  Measurement of the backgrounds   and  results.
Results and perspectives of the solar axion search with the CAST experiment Esther Ferrer Ribas IRFU/CEA-Saclay For the CAST Collaboration Rencontres de.
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
The COBRA Experiment Jeanne Wilson University of Sussex, UK On behalf of the COBRA Collaboration TAUP 2007, Sendai, Japan.
1 MPGD2009 Advancements of labelled radio-pharmaceutics imaging with the PIM-MPGD J. Donnard a, N.Arlicot b,
I. Giomataris, CEA-Irfu-France
Search for new physics from the CERN Axion Solar Telescope (CAST) high-energy calorimeter David W. Miller Advisor: Juan I. Collar Bachelor’s thesis Defense.
NoV. 11, 2009 WP meeting 94 1 D. Attié, P. Colas, E. Ferrer-Ribas, A. Giganon, I. Giomataris, F. Jeanneau, P. Shune, M. Titov, W. Wang, S. Wu RD51 Collaboration.
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
R&D Collaboration, CERN – September 10, Micromegas Performance and Ageing studies David Attié MPGD. Towards an R&D Collaboration,
Systematic studies for microbulk detectors E. Ferrer Ribas, A. Giganon, Y. Giomataris, FJ Iguaz, T. Papaevangelou (Saclay) A. Gris, R. de Oliveira (CERN)
Energy resolution results for Microbulk MICROMEGAS at high energy and pressure. Alfredo Tomás Alquézar Universidad de Zaragoza on behalf of the collaboration.
R&D WITH MICROMEGAS FOR LOW BACKGROUND APPLICATIONS: THE T-REX PROJECT Laura Seguí and Juan Antonio García Universidad de Zaragoza CEA, Saclay December.
SIMULATION OF BACKGROUND REDUCTION TECHNIQUES FOR Ge DBD DETECTORS Héctor Gómez Maluenda. University of Zaragoza. GERDA/Majorana MC Meeting.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
Precision Drift Tube Detectors for High Counting Rates O. Kortner, H. Kroha, F. Legger, R. Richter Max-Planck-Institut für Physik, Munich, Germany A. Engl,
NEXT: A Neutrinoless 2  Experiment with a Gaseous XeTPC Thorsten Lux IFAE Barcelona in behalf of the NEXT Collaboration.
TPC for ILC and application to Fast Neutron Imaging L. An 2, D. Attié 1, Y. Chen 2, P. Colas 1, M. Riallot 1, H. Shen 2, W. Wang 1,2, X. Wang 2, C. Zhang.
ICARUS T600: low energy electrons
GEM and MicroMegas R&D Xiaomei Li Science and Technology
Saikat Biswas, A. Abuhoza, U. Frankenfeld, C. Garabatos,
Double Beta Decay of 48Ca with CaF2(Eu) - ELEGANT VI -
Potential Ion Gate using GEM: experiment and simulation
The MICROMEGAS detector in CAST
High Rate Photon Irradiation Test with an 8-Plane TRT Sector Prototype
Gain measurements of Chromium GEM foils
Presentation transcript:

Low X-ray background measurements at the Underground Canfranc Laboratory E. Ferrer-Ribas, I. Giomataris, F.J. Iguaz T. Papaevangelou - IRFU/CEA-Saclay T. Dafni, J.A. García, I. Irastorza, A. Rodríguez & A. Tomás – Univ. Zaragoza T. Vafeiadis – CERN/AUTH A. Gardikiotis – University of Patras C. Yildiz - Dogus University J. Galan - IRFU/CEA-Saclay On behalf of the CAST Micromegas team

The role of low X-ray background detectors for the axion search in the CAST experiment. Low nominal background levels achievable with Micromegas detectors. Where it does come from the motivation to study and characterize the influence of different shielding set-ups? Set-up preparation and background levels achieved Underground. Geant4 simulations to undestand the background nature. Undergoing CAST experiment shielding tests. A preview of this talk …

CAST sensitivity depends on the detector background 0.3 counts/hour in 14.5 cm 2 g aγγ = GeV -1 Helioscope detection principle and CAST experiment description The CAST experiment Idea : Axions would be produced in the Sun’s core and re-converted to x-rays inside an intense magnetic field. P. Sikivie, Phys. Rev. Lett. 51, 1415–1417 (1983) CAST is using a prototype superconducting LHC dipole magnet able to track the Sun for about 1.5 hours during Sunrise and Sunset. Operation at T=1.8 K, I=13,000A, B=9T, L=9.26m Expected signal X-Ray excess during tracking at 1-10 keV region Earth axion spectrum

Micromegas detectors in CAST after 2008 The CAST experiment Remarkable improvement of Micromegas detectors inside CAST experiment. 3 Micromegas (Microbulk technology) installed in 3 of the 4 CAST magnet apertures. Operating with Ar + 2% Isobutane at 1.45 bar Readout 106x106 strips -> 6x6 cm2 Plus mesh temporal signal Detectors installation in 2008 Sunrise side detector Sunset side detectors

Pulse shape Fast pulses Strips and mesh energy balance The CAST experiment X-ray events selection is obtained from temporal and spatial information 6keV events from an 55 Fe source are used for X-ray selection and background discrimination. No cuts: Including only 1 xy-cluster events

The CAST experiment Nominal background levels in CAST during last data taking periods. The nominal background during recent data taking phase is below keV -1 cm -2 s -1 Mean background evolution during 2008 data taking period for Sunrise side detector. Nominal background level before 2007 (~4.5 x1 0-5 keV -1 cm -2 s -1 ). Standard Micromegas + naked detector Meaning around 2.25 counts per hour at the CAST sensitive area and energy.

The CAST experiment Ultra-low background periods observed in CAST Several ultra-low background periods appeared in 2009 and Impressive result, but yet non well understood background reduction. Radon? Nitrogen flow? Humidity? Always around September. Lower level would increase our sensitivity, so … Where is the lowest limit of background level?

Measurements at the Canfranc Underground Laboratory We need to know … What is the nature of the background reduction in CAST? Which is the lower limit of background level we can reach? Lower level would increase our sensitivity, so … It is important to study and to understand the influence of external background in order to improve our set-up on CAST. Thus, further tests under laboratory controlled conditions are well motivated

New acquisition software completely based in C++, ROOT, python and GNUPLOT. Shielding reproduces sunrise configuration. Faraday box prepared for automatic calibrations with 55 Fe source. Slow control: temperature and pressure and detector currents Gas, Ar + 2% iso, flowing in open loop with flow and pressure controlled Some modifications in electronics. Fundamental modules are the same. Nitrogen flux = l/h (for vol < 17 l) Capacity for more than 2 weeks. Measurements at the Canfranc Underground Laboratory Set-up at the laboratory in the Universty of Zaragoza

All the connections extracted via feedthroughts. internal configuration: front-end electronics and shielding 4π inner shielding: 5 mm Cu + 25 mm Pb + 8 cm polyethylene external shielding (With exception of a minimum gap for the calibrator to introduce the source) Automatic calibration system N2 flowing into the inner shielding Measurements at the Canfranc Underground Laboratory The detector Faraday cage set-up

Canfranc Underground Lab (LSC) situated in the spanish Pyrenees at the deep of 2500 m.w.e  10 4 reduction factor in cosmic muons  Stable environmental conditions (T, P, humidity)  Environmental gamma radiation well known. At surface, registered ~1 Hz trigger rate and performed a final background level of: ~8·10 -6 counts keV -1 cm -2 s -1 (2-7 keV) Once underground trigger rate is only ~0.2 Hz and the background: ~9·10 -6 counts keV -1 cm -2 s -1 (2-7 keV)  Cosmic rays domain the trigger rate at surface but had only a small effect in background after offline analysis, events are easily discriminated.  In principle the level obtained is comparable to CAST nominal background with a CAST like shielding. The CAST experimentMeasurements at the Canfranc Underground Laboratory The Micromegas X-ray detector fingerprints (Microbulk M10 detector)

Measurements at the Canfranc Underground Laboratory Equipping the lab for installing lead and preparing cleaning material Roman Lead bricks ( 4 tons ) Cleanning material Underground habitants Final shielding emplacement

Measurements at the Canfranc Underground Laboratory Lead bricks cleaning process Cleaning ingredients: 1. Nitric acid (4%). HNO 3 2. Distilled water 3. Alcohol (as much as better) Cleaning process Cleaning and transporting lead is a heavy task. Lead transportation device

Measurements at the Canfranc Underground Laboratory Final shieding installation Some members of the crew proud of the new heavy gift just installed. Bricks ready to be mounted. Crosschecking electronic noise and acquisition tuning Small cabling passthrough hole

CAST-like shieldingShielding upgrade Measurements at the Canfranc Underground Laboratory Effect on the overall trigger rate 0.2Hz Trigger rate before cuts 0.02Hz

Measurements at the Canfranc Underground Laboratory Nitrogen flux effect on the spark rate Spark rate as measured by the power supply current increases when the Nitrogen flux is disconnected. Since the sparks were not observed on surface, they are probably due to the higher radon abundance underground (4.8 MeV  s). Nitrogen flux ON Nitrogen flux OFF

Complete: 20 cm external Pb “Half” closed: 5π/6 20 cm external Pb CAST-like: No external Pb (but still 4п) 0,5 cm Cu + 2,5 cm Pb + Nitrogen flux to avoid Rn Measurements at the Canfranc Underground Laboratory 3 different shielding configurations

1 week with 109 Cd source Hz trigger rate First approach to final background limited only by intrinsic radioactivity (from microbulk, chamber materials, inner shielding): < 2·10 -7 counts keV -1 cm -2 s -1 [2-7 keV] (~1 count/day) This result proves that background levels >20 times lower that current CAST MM nominal background are possible via shielding improvement. 0.2 Hz trigger rate Measurements at the Canfranc Underground Laboratory 3 different configurations underground

Internal part of the shielding is based in copper (including the cathode with the calibration window in Canfranc’s set-up) An excess of counts around 5-6 keV made us think about the presence of a soft X-rays source in the environment of the detector (maybe 55 Fe contamination). Blocked window config Calibration window (4 µm thickness) Limiting the background? Measurements at the Canfranc Underground Laboratory Contamination coming from the drift window side

Measurements at the Canfranc Underground Laboratory The lowest background level reached Removing the hotspots from the data we obtain the following background lower limit Effective exposure time hours Rate (2-7keV)1.46e-07 keV -1 ·cm -2 ·s -1 Rate (2-9 keV) 1.71e-07 keV -1 ·cm -2 ·s cm Effect from 8keV peak 2 Hotspots are found in the background hitmap during these days. A total of 21 events from 62! concentrated in 2 spots of 2.2mm 2 : 9 and 12 events

Measurements at the Canfranc Underground Laboratory The lowest background level reached Removing the hotspots from the data we obtain the following background lower limit Effective exposure time hours Rate (2-7keV)1.46e-07 keV -1 ·cm -2 ·s -1 Rate (2-9 keV) 1.71e-07 keV -1 ·cm -2 ·s cm Effect from 8keV peak 2 Hotspots are found in the background hitmap during these days. A total of 21 events from 62! concentrated in 2 spots of 2.2mm 2 : 9 and 12 events Effective exposure is 41 days. If we do not consider the events in the spot it means 1 count/day! (In the actual CAST detection area) On average, 1 background count every 16 trackings! With a background level like that, it looks easier to see axions, or not? Remark: Beginning of CAST the background was around 15 counts/tracking

Geant4 Simulations Strips and mesh readout generation from Geant4 simulation. Simulations include a detailed geometry and readout electronics, including temporal and spatial signal, in order to apply the corresponding discrimination cuts afterwards. Comparison between experimental results and outcome of simulations will allow to determine the nature of the background, and to optimize future shielding set-ups.

Shielding improvement at the CAST experiment CAST Sunrise detector shielding upgrade Additional tests are actually going on at CAST experiment in order to improve the background level for the coming data taking period. The idea is to reduce the background by shielding the iron stainlessteel pipe which could produce additional fluorescence. Background analysis is going on already, a considerable reduction has been observed, but it is early to give a final value.

Background levels of Micromegas detectors in CAST over the years. Nominal values during data taking campaigns Unshielded Micromegas (classic technology) Shielded Micromegas (bulk and microbulk technology) Especial shielding conditions in Canfranc Underground Lab Shielding improvement at the CAST experiment Final conclusions The improvement of the shielding design. + The fact that microbulk technology is built from low radiactivity materials. + The improved discrimination capabilities of the microbulk detector given by a better energy resolution. = An improvement in the lower background level reached during last years.

Backup Slides

M10 55 Fe Spectrum ≈ 15% FWHM - Similar CAST operating conditions. - Ar+2% Iso at 1.4 bar. - Good energy resolution irradiating the entire surface of the detector. The CAST experimentMeasurements at the Canfranc Underground Laboratory The Micromegas X-ray detector fingerprints (Microbulk M10 detector)

Measurements at the Canfranc Underground Laboratory Many different settings for understanding influence on background Each 1-2 weeks a new setting/modification is applied in order to see the influence on the background level. Main changes concern to Timing Settings and Drift window materials.

Measurements at the Canfranc Underground Laboratory Many different settings for understanding influence on background An example, 2 comparable different settings with blocked window. Background Level 1.32e-07 keV -1 ·cm -2 ·s -1 Background Level 1.63e-07 keV -1 ·cm -2 ·s -1

Shielding improvement at the CAST experiment CAST Sunrise detector shielding upgrade Additional tests are actually going on at CAST experiment in order to improve the background level. The idea is to reduce the background by shielding the iron stainlessteel pipe which could produce additional fluorescence. Background analysis is going on already, a considerable reduction has been observed, but it is early to give a final value.