Clinical Observations of the Single-Use Irrigation/Aspiration Tip

Slides:



Advertisements
Similar presentations
Manual Vs Instrumental Phaco
Advertisements

TESTUPLOAD. TORSIONAL PHACOEMULSIFICATION In January 2006 Alcon Surgical incorporated Ozil torsional into the Infiniti Vision System. Unlike the conventional.
OHM Comparative quantification of ingress of trypan blue into anterior chamber following microcoaxial phacoemulsification with torsional or longitudinal.
ASCRS-ASOA Early Regression of Limbal Relaxing Incisions in Phacoemulsification Patients: At 1 and 6 Weeks Postoperatively by Melissa M. Cable, MD,
Comparison between phaco-chop, divide-conquer and stop & chop phaco-technique according to the cataract density Hae ri Yum, M.D., Man Soo Kim, M.D. Eun.
Early Outcomes of Descemet’s Stripping Automated Endothelial Keratoplasty in Pseudophakic Eyes with Anterior Chamber Intraocular Lenses Preeya K. Gupta.
Action on cataract Whipps Cross Hospital Harold Wood Hospital North East London Eye Partnership.
CATARACT ASSESSMENT Cataract: opacity of the lens Population at risk: greater than 70 years old S&S: blurred vision.
Yüksel Totan, Ramazan Yaĝcı, Zeynel Arslanyılmaz, Uĝurcan Keskin The authors have no financial interest.
Clear Corneal Vitrectomy Combined with Phacoemulsification and Foldable Intraocular Lens Implantation. Takeshi Iwase , Tsuyoshi Yoshita  and Kazuhisa.
The new Akreos MI 60 lens Joel Pynson, MD - Director Design Engineering Bausch & Lomb, Toulouse - France London, September 9th 2006.
Astigmatism Following 2 IOL Injection Techniques: Wound Assisted Versus Wound Directed Jay J. Meyer, MD Hart B. Moss, MD Kenneth L. Cohen, MD University.
Dislocation of the DSEK Donor Graft into the Posterior Segment An Intraoperative Complication in DSEK Surgery Mark M Fernandez MD, Mark S Gorovoy MD, George.
Core Anterior Vitrectomy following Posterior Capsular Rupture SURYA.
Phaco-drainage Phacosection Amporn technique
Outcomes of surgery for posterior polar cataract using torsional handpiece Dr. Aysel Pelit, Dr. Yonca A. Akova Baskent University, Faculty of Medicine,
Implantation of a single-piece acrylic intraocular lens using an anterior chamber maintainer Tomoyuki Kunishige, Hisaharu Suzuki, Toshihiko Shiwa, Hiroshi.
Removal of Pediatric Cataract with Intraocular Lens Implantation Using 23 gauge Incisions and 25 gauge Instrumentation Irena Tsui, M.D. Steven Kane, M.D.,
Thermal Imaging Comparison of Longitudinal versus Torsional Phacoemulsification in INFINITI Young Keun Han, M.D., Kevin M. Miller, M.D. Department of Ophthalmology,
Contrast-Enhanced Corneal Wound Imaging by Optical Coherence Tomography Preeya K. Gupta, MD Justis P. Ehlers, MD Terry Kim, MD Duke Eye Center, Durham,
So-Hyang Chung, MD, PhD, Choun-Ki Joo, MD, PhD Department of Ophthalmology and Visual Science, College of Medicine, The Catholic University of Korea, Seoul,
Hyun Seung Kim, M.D. Department of Ophthalmology, St. Mary’s hospital, The Catholic University of Korea Changes in Astigmatism After Clear Corneal Temporal.
Transparency of Transition from 2.75 mm to 1.8 mm Microincision Surgery Jay McDonald II, MD Adjunct Clinical Professor University of Arkansas School of.
Assisting with minor surgery and suture removal. Minor Surgery includes Removal of warts, cysts, tumors, growths, foreign objects Performing biopsies.
Pop and Pre-Chop A Safe Supracapsular Phacoemulsification Technique
Kendall R.B. Dobbins, MD Geisinger Medical Center
Step by step: Learning Phacoemulsification and MICS for Tremor Surgeons Gede Pardianto Sumatera Eye Hospital Medan - Indonesia.
Evaluation of Corneal Parameters and Spherical Aberration After DSAEK Measured with Pentacam System Orkun Muftuoglu, Pawan Prasher, R. Wayne Bowman, Steven.
1.8 mm Cataract Surgery: Clinical Results 6 Months after Coaxial and Biaxial MICS and Implantation of a New Micro- incision IOL Rosa Braga-Mele, M. Ed,
Spending 40 cc in an entire Cataract Surgery. Comparative study. Arturo Pèrez-Arteaga M.D. Medical Director & Founder Centro Oftalmològico Tlalnepantla,
Occurrence of Retinal Detachment After Cataract Surgery Peter Jeppesen MD, PhD and Thomas K. Olsen, MD, DMSc Department of Ophthalmology Århus University.
Implantable Collamer Lens Complications
Recentering of ReZoom IOL by Suturing Technique to Optimize Visual Acuity Francis A. D’Ambrosio Jr., M.D. Lisa M. Wilson, O.D. Lancaster, MA.
*Financial Interest: The authors have no financial interest in the subject matter of this poster. *Disclosure of Unapproved/Off-Label Use: The use of cholesterol.
Astigmatism management with toric intraocular lenses in cataract patients Adriano Guarnieri 1-2, Luis W. Lu 3-4, Alfonso Arias- Puente INCIVI, Madrid,
Riley Hall BSc α, Robert Mitchell MD, FRCSC β University of Saskatchewan α, University of Calgary β Authors have no financial interest Comparison of postoperative.
Mitsui Memorial Hospital Takayuki Akahoshi, MD The author has no financial interest in the products introduced in this presentation.
Analysis of Intraoperative Capsular Trauma Induced by a New Single-Use Polymer Irrigation/Aspiration Tip During Posterior Capsule Polishing Don Davis,
A New Technique for Precise, Predictable SBK Surgery Using the B&L Zyoptix XP Microkeratome David R. Shapiro, MD Shapiro Laser Eye Center Ventura, California.
Thermal Study of Longitudinal and Torsional Ultrasound Phacoemulsification : Tracking the Temperature of Corneal Surface, Incision and Handpiece Bokkwan.
The Effect of Corneal Anterior Surface Eccentricity on Astigmatism after Cataract Surgery Choul Yong Park MD 1 Sung Jun Lee MD 1 Prabjot Channa MD 2 Roy.
Modern Cataract Surgery Professor Ejaz Ansari, FRCOphth MD.
Relationship Between Postphaco TASS and U/S Tip and Sleeve Lumen
Influence of IOL optic material on posterior capsule opacification and visual function Ken Hayashi, MD Hideyuki Hayashi, MD Hayashi Eye Hospital, Fukuoka,
Zonular Weakness in Patients with Primary Angle-Closure Glaucoma Yong Yeon Kim 1, Keny Kirti 2, Bokun Rho 1 Department of Ophthalmology, Korea University.
Corneal Wound Architecture and Integrity after OZil and Mixed Phacoemulsification: Evaluation of Standard and Microincisional Coaxial Techniques Bokkwan.
Johns Hopkins Hospital
Anesthetic Effect of Topical Agents in Cataract Surgery Ross B. L. MacIntyre, MD Paul S. Koch, MD Dr. Ross MacIntyre has no financial interests to disclose.
Corneal Wound: Architecture and Integrity Luis E. Fernández de Castro, M.D. 1 Helga P. Sandoval, M.D., M.S.C.R. 1 Kerry D. Solomon, M.D. 1 1 Magill Research.
Advanced Preloaded IOL System A Visco-free Preloaded Injector Kimiya Shimizu MD Professor & Chairman, Department of Ophthalmology Kitasato University,
Date of download: 5/28/2016 Copyright © ASME. All rights reserved. From: An Experimental Low-Cost Ultrasonic Phacoemulsifier—A Prototype Test J. Med. Devices.
Pearls for Success with the Synchrony Dual-Optic Accommodating IOL Preloaded Injector Víctor M. Bohórquez, MD Ricardo Alarcón, MD ServiOftalmos Bogotá,
Corneal Endothelial Cell Loss Results in a Comparison of Longitudinal vs. Torsional with Vacuum Demand Interjected Longitudinal (IP) Phacoemulsification.
Nepafenac-Assisted Mydriasis During Cataract Surgery in a Rabbit Model Michael K. Yoon, MD and Stephen McLeod, MD UCSF Laser Vision Center, San Francisco,
Rengaraj Venkatesh, MD, Colin S. H
Authors have no any financial interest in the subject matter
Special considerations for DSEK in monocameral eyes
Experimental evaluation of various disposable micro-incision knives in comparaison to a diamond knife G. LESIEUR ALBI P: Royalty from a PhysIOL ophthalmic.
Cataracts and Cataract Operations (Second of Two Parts)*
The authors have no financial interest
 فیکو امروزه از دستگاه فیکو برای عمل های جراحی چشم مورد استفاده قرار می گیرد . بخاطر پیشرفت های زیادی که در این دستگاه وجود دارد طول برش روی قرنیه . عوارض.
B.MALYUGIN MD,PhD A.GOLOVIN MD
Hayashi Eye Hospital, Fukuoka, Japan
versus 2.75mm Incision Phacoemulsification
성모병원 안센터 CHANGES IN ASTIGMATISM RELATIVE TO IOL HAPTIC INSERTION AXIS IN WITH-THE-RULE AND AGAINST-THE-RULE ASTIGMATISM PATIENTS Hyun Seung Kim, M.D.
Hayashi Eye Hospital, Fukuoka, Japan
Authors have no financial interests
Eye Clinic Day Hospital - SÃO Paulo - Brazil
Five-Year Experience With Routine Use of Healon5 in Cataract Surgery
A Simple and Easy Procedure
Presentation transcript:

Clinical Observations of the Single-Use Irrigation/Aspiration Tip Preeya K. Gupta, MD Terry Kim, MD Duke Eye Center Durham, NC Financial Disclosures: TK—consultant for Alcon

Purpose To assess the clinical performance and experience of the newly introduced single-use Intrepid® Polymer irrigation and aspiration (I/A) tip Methods Design: Retrospective review of a single surgeon experience during routine phacoemulsification

Intrepid® Polymer I/A tip Specially designed for MICP (microincisional coaxial phacoemulsification), 1.8—2.4 mm incisions Soft, smooth polymer tip Disposable, single-use tip

Intrepid® Polymer I/A: 3 Tip Types Straight Tip 35° Bent Tip 20° Curved Tip

Metal I/A: 3 Types of Tips Straight Tip 45° Tip 90° Tip

Metal/Silicone vs Intrepid® Polymer I/A tips Metal tips may have sharp edges and tears in silicone tips and/or sleeves can increase the risk for posterior capsule damage/tear Metal tips can stretch the wound Intrepid® Polymer I/A tip easily fits through 1.8—2.4 mm corneal incisions and is capsule-friendly

Clinical Pearls for Using the Intrepid® Polymer Single-Use I/A tip - May have to steepen the angle of the handpiece upon insertion/removal to avoid ‘catching’ the wound edge

Transitioning Users of the 90° metal I/A tips may find it easier to transition to the 35° Intrepid® Polymer I/A tip Users of the 45° and straight metal I/A tip should try either the 20° or 35° Intrepid® Polymer I/A tip Straight 35° Bent Tip 20° Curved Straight 45° 90°

Results The new Intrepid® Polymer I/A tip is specifically designed for MICP and provides superior performance to the metal I/A tips and comparable performance to the silicone I/A tips The transition to this tip is seamless with a short learning curve The disposable, single-use nature of this new polymer tip has theoretical value in prevention or decrease in post-operative infections and toxic anterior segment syndrome (TASS)

Conclusions The Intrepid® Polymer single use I/A tip is a viable alternative to traditional I/A tips and may provide advantages over traditional metal I/A tips and silicone I/A tips.