PS3500 Power and Diagnostics Powering Availability.

Slides:



Advertisements
Similar presentations
Innovations Technology. Forward
Advertisements

Team: – Brad Jensen – Will Klema – Nate Schares Client: – PowerFilm, Inc. Advisor: – Dr. Ayman Fayed Solar-Powered Mobile Power Station (MPS)
MODULAR SMPS POWER PLANT
E VERY L IFE H AS A P URPOSE… Flame Detection Theory.
E VERY L IFE H AS A P URPOSE… FlameGard 5 UV/IR Flame Detector The Benefits of HART on Installation and Maintenance of Flame Detectors.
SITOP power - uninterruptible 24 V Excellencein Automation&Drives: Siemens A&D SE PS 9/00 N o 1 A standard with variety current keeps right on flowing.
Aloha Proof Module Design Cabled Observatory Presentation School of Ocean and Earth Science and Technology February 2006.
Chapter 8 Output Modules.
POWER SUPPILES LECTURE 20.
Phaseo Power Supplies ACE Expert Training Presentation 2009.
The Interface Solution Experts Intrinsically Safe Design, TCM installs in: Class I, II, & III Div 1 and 2 (Zones 0/1 & 2) Up to 32 Channels.
1 Modular DC/DC Converter. 2 PSC W Standard 19“ rack 4U – 6 prewired slots (single DC input/output connection for each unit)
1 © Red Lion Controls Inc. Introducing the RAM 9000.
System Elements HighPoint Broadband Delivery System Sector 1 Sector 3
DKTCOMEGA EDFA Product Line Jesper Broszka, Product Manager.
15. CBM Collaboration Meeting, GSI, Darmstadt, April 12–16, 2010 Status of Front End Electronics N-XYTER PCBs & Power Supply Volker Kleipa, GSI Darmstadt.
IUPS101 Product Overview I Copyright Extronics Ltd 2011 iUPS101 Partner Webinar Ross Tye, Andrew Peek & Paul Lazor 12 th Dec 2011.
AC backup solutions for business continuity. Secure your business, Stay on!
Emco High Voltage DC to DC Converters BY John Kmiec.
POWER PLANT USED IN TELECOM
InnovationValueTeamwork SHENZHEN INVT ELECTRIC CO., LTD.
MarsⅡ On-Line UPS Series
Dupline Specialist Seminar Jens Neigaard DuplineSafe.
HydroFly: Fuel Cell Group Group Members: -Adam Lint -Chris Cockrell -Dan Hubbard Sponsors: -Dr. Herb Hess -Dr. Brian Johnson.
Energy Consumption Dr. Farid Farahmand. Cost of one KWatt-hour.
Controls and Electrical Preferred Technologies Steve Pavis PH-DT-DI CERN Advel Power Supplies and ABB Circuit Breakers.
MUEV Phase III By: Kevin Jaris & Nathan Golick. Introduction Petroleum is a finite resource. Demand for clean energy is driving the increase in the production.
MonsonPeer Review – 5 December 2014 SPP/FIELDS LNPS PEER REVIEW Steven Monson University of Minnesota 1.
Smart Grid: Opportunities in the Data Center January 22, 2010 Charles O’Donnell, Vice President, Engineering Liebert AC Power Emerson Network Power.
1 Low Voltage Power Supply Specification DCS Workshop 8 Sept 03 L.Jirden.
E VERY L IFE H AS A P URPOSE… FlameGard 5 MSIR Flame Detector.
Engineer Training UV Electrical Cabinet (1-15) TJ8300 / TJ8500 UV Electrical Cabinet (Machines 1-15)
GSM sites Cooling systems description Standard Air Conditioner SystemEmergency Cooling SystemEnergy Saving Cooling System Air Conditioner Cooling system.
LDO or Switcher? …That is the Question Choosing between an LDO or DC/DC Converter Frank De Stasi Texas Instruments.
Power Supply System for DRFS
Excom ® Remote I/O in Zone 1. excom ® excom ® One system for all requirements in Zone 1.
Intermediate Course (3) Technical Basics - 2 Circuits Karl Davies East Kent Radio Society EKRS 1.
the compact air control solution
Chapter 2.3 Notes Work in Electrical Systems. A force does work on an object when it moves the object. A force does work on an object when it moves the.
1 Chelmsford Amateur Radio Society Intermediate Licence Course Murray Niman G6JYB Slide Set 4 (3) Technical Basics -2: Circuits Chelmsford Amateur Radio.
LP Series 400V CE GE Consumer & Industrial September 2004.
1 Powerware kVA The modular, scalable, redundant UPS for midrange applications.
Power Electronics and Switch Mode Power Supply
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
ACT20X Ex isolator/ amplifier. Page 2 ACT20X (Ex isolators family) Overview - Connects to process equipment in Class/Div, or Zone 0 - Zone 2 areas - ACT20X.
DC/DC Converter. Innovative products for industrial automation Stabilize control voltages in 24 V DC systems Compact and powerful DC/DC converters for.
PRO-H Power Supplies. PRO-H Series  P owerful R eliable O ptimized - H azardous Areas  Complete family of Power Supplies 1-phase 3.8A up to 25A  Output.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
FLATPACK Rev.5 September 2002 Updated versions may be available.
ESX10-T Electronic Circuit Protectors with Hazardous Area approvals.
Introduction to Linear Voltage Regulators Krishna Kishore Reddy K 2010H223084H.
Audio Power Amplifier Detailed Design
음향 시스템 사양서 POWER SUPLY WITH 3.5 PHOENIX CONNECTOR AMX: PSN6.5
EPR = Electronic Products and Relays
A transformer is a complex protective object
Power Block Implementation
Magnetostrictive Liquid Level Transmitter
PowerValue 11/31 T Sales Presentation
Introduction to Linear Voltage Regulators
Uninterruptable Power System
Harsh Environment Uninterruptable Power System
BLOCK DIAGRAM: Micro controller.
Outdoor Uninterruptable Power System
Uninterruptable Power System
Outdoor Uninterruptable Power System
Harsh Environment Uninterruptable Power System
Building a 2 KW SSPA for 23cm
XW9048(Xantrex inverters)
GasGard 100 Control System
Presentation transcript:

PS3500 Power and Diagnostics Powering Availability

What is an acceptable amount of downtime?

 Universal AC or DC input  22.5 …30 VDC adjustable output  15 Amps per module  Up to 91% 230 VAC input  Active load sharing High-Integrity Power

Failure of one module will not impact system operation  High system reliability (no internal fans)  ATEX Zone 2 and Class I/Div. 2  Hot-Swappable  Low noise for HART and Fieldbus applications

Thermal Dissipation Power supplies lose energy in the form of heat  PS3500 has very low heat dissipation due to high efficiency  +45° C without de-rating

Configurable Redundancy 90 A MAX 30 A MAX 45 A MAX

What if you could monitor power like any other field device?

PS3500 Diagnostic Module MainsOutputMonitoringPowerSuppliesDiagnostics Four layers of monitoring

Diagnostics Voltage Current Spikes Primary Voltage Ripple & noise Overall current Secondary 4 Temperatures Output current DC/DC frequency Usage clock Power Supply Ambient temperature Comm checksum Redundancy status Diagnostics

Warnings and Alarms  Configurable alarms  Log and time stamp  Simple setup

Plant Asset Management Integration Asset Management Integration  AMS - EDDL  RS485/HART  FDT/DTM

Markets  Where is N+1 redundancy required?  Oil & Gas Refineries  Continuous process Facilities  Safety Shut down systems /SIL 3  Offshore platforms  Fieldbus projects

PS3500 Application Success Stories  Shell  Shell/Albian Sands (Upstream) mine site- Bulk power for C300 control cabinets  Shell/Scotford Upgrader site: Bulk power for C300 control cabinets  Bentley Nevada / GE  Redundant bulk power vibration monitoring system  Mikron Infrared : Coal Gasification  Bulk power for Infrared camera purge: monitoring gas separation units  Cargill  Blaire, NE providing 24VDC redundant bulk power to instrumentation, throughout their facility...they produce corn based petroleum products; including eco friendly plastics, and ethanol