19 Oct NIKHEF update 3 lines of attack: 1)Heating (Mod 30) 3 days at 45 C, 4 days at 48 C Q1: Change in geometry, gas tightness, gain? Q2: Effect on ageing? 2)Flushing (Mod 2) Improves rapidly, but suddenly worse Q: why?? 3)HV training (Mod 3) Damage reappears after 200 hrs Q: 200hrs of irradiation, or time constant?
19 Oct ) Heating Mod 30 Setup
19 Oct ) Heating Mod 30 Temperature: 1 st heating 3 days Procedure 1)Module 30 is heated while flushing with CO 2 2)One day at 35C 3)3 days at 48 C 4)4 days at 48 C Logbook 22-29SepMeasure dimension, gas tightness 29Sep35C1 day 29Sep-2 Oct48C3 days 2-4 OctMeasure dimension, gas tightness 4 OctFlush 24 hrs, then irradiate 6-10 Oct48C>4 days 10 OctMeasure dimension, gas tightness 10 OctFlush 24 hrs, then irradiate Sep29 Oct 2
19 Oct ) Heating Mod 30 Temperature: 2 nd heating 4 days Procedure 1)Module 30 is heated while flushing with CO 2 2)One day at 35C 3)3 days at 48 C 4)4 days at 48 C Logbook 22-29SepMeasure dimension, gas tightness 29Sep35C1 day 29Sep-2 Oct48C3 days 2-4 OctMeasure dimension, gas tightness 4 OctFlush 24 hrs, then irradiate 6-10 Oct48C>4 days 10 OctMeasure dimension, gas tightness 10 OctFlush 24 hrs, then irradiate Oct 5 Oct 6
19 Oct ) Heating Mod 30 Geometry: Flatness Flatness: Module is flat to +/- 200 μm Change after heating <100 μm Before After Row III II I
19 Oct ) Heating Mod 30 Geometry: Length Length: Module shrinked by 1.03±0.10mm Module shrinked by additional 0.38±0.10mm These shifts are easily seen by eye… DateabAverage (a+b)/2 Nominal: 2.46mm Delta 22Sep Sep Oct Oct Oct mm 8.0mm a b module table a+b/2
19 Oct ) Heating Mod 30 Geometry: Width Width: Module shrinked by 100 μm +/- 50 μm
19 Oct ) Heating Mod 30 Geometry: Shape Before After Consistency check of decreased width: ~ -100μm Shape: Straight within +/-100μm
19 Oct ) Heating Mod 30 Gas Tightness Before 1 st heating 2 nd heating DateLeakage Flow (l/s) 22Sep Sep Oct Oct Oct Oct Gas tightness: OK, Unchanged: l/s ± l/s Corresponding to 0.007mb/min
19 Oct ) Heating Mod 30 Ageing Sep 4, after 6 days of flushing Sep 19, after HV training Oct 4, after 3 days at 48 C Ageing: No sign of improvement after 3+4 days at 48 C! Module became very noisy?? Oct 11, after 3+4 days at 48 C Scan after Scan before
19 Oct Conclusions: Module 30 follows initial pattern from mod 2 What happened with module 2 ?? Briefly opened when moved from setup to setup Gas had finished before worsening of module 2 Flushing is only temporary benificial !? similar for heating?? 2) Long term flushing Module m 3 Compare to result from Heidelberg: 100 days M002 ?!? Heating of M030!?
19 Oct ) Long term flushing dips in Module 3? History: 21Mar – 12Apr: 28Mar-11Apr: opened module 15Apr – 23May: 25Apr-10May: played with water bottle 10May-15May: module not connected 23May – 19Jun: 6Jun: Change Ar bottle 6Jun – 19 Jun: Addition of O 2 19Jun-15Aug 20Jun-14Jul: module not connected ModDateLocI(nA)Time (hrs) 13B18Jancleanroom B23FebLab B21MarLab B12AprLab A15AprLab A23MayLab A19JunLab A15AugLab Mar: opened module during 14days 10May: opened module during 5days 6Jun: flushed with 4% O 2 for 13days 20Jun: opened module during 24days
19 Oct ) HV training Gas flow Conditions: Flow: Ar/CO 2 70/30, 20 l/hr Irradiation: 2mCu, 90 Sr source Sequence: 1)HV training ~40 hrs 1870 and 1920V 2)Irradiate 340 hrs 3)HV training 18 hrs 1910 V Conclusions: A second HV training helps again 340 hrs After HV Lower? 2 nd HV training1 st HV training NB: 700 hrs ~ s ~ 3 months nominal LHC hrs Rel.gain 3 rd HV training Lower??
19 Oct ) HV training Question: 1)Does it prevent ageing during 200 hrs of irradiation 2)Or does it prevent ageing for 200 hrs of flushing… It looks like 1) But untrained part improves!? 2 nd HV training1 st HV training3 rd HV training 8 days of flushing 3 days of flushing ?? Gain indeed went up Ratio 10Oct/3 Oct: 3Oct 29Sep -3Oct 10Oct
19 Oct ) HV training Question: Is ageing also prevented at previously unirradiated spots (pos. 190cm) ? Marginally… This seems in contradiction with measurements of Aug 20 on unirradiated spot (pos. 200cm) 20hrs 96hrs Deepest point Integrated loss over surface
19 Oct ) Heating Mod 30: high currents cured? After heating: many channels with high current 1)Loose wire tension? (shorter module?) 2)Loose wire tension? (loose soldering?) 3)Deformation of straw? 4)Humidity in module? 5)Broken feedthrough board? After additional 3 days of flushing: high currents disappeared! Scan after heating: Scan after heating and additional 3 days of flushing:
19 Oct Development of Currents: ch1; the side
19 Oct Development of Currents: ch64; the side
19 Oct Development of Currents: ch33; irradiated
19 Oct Development of Currents: ch27; ?
19 Oct ) Heating Mod 30 Ageing Sep 4, after 6 days of flushing Sep 19, after HV training Oct 4, after 3 days at 48 C Ageing: No sign of improvement after 3+4 days at 48 C! Module became very noisy?? Oct 11, after 3+4 days at 48 C Oct 16, 7days heating +4days flushing
19 Oct Ageing after Heating+Flushing Ageing: No sign of improvement after 3+4 days at 48 C Some improvement after flushing, but is it more than expected? Slope is nicely steep But is there a factor 5? 3+4 days heating +4 days flushing 3+4 days heating (heated module)
19 Oct A closer look: compare (using deepest point definition) 3+4 days heating +4 days flushing 3+4 days heating Conclusion? 11 days heating +3 days flushing Heidelberg 17 days heating
19 Oct A closer look: compare using HD definition 3+4 days heating +4 days flushing 3+4 days heating HD: ~90hrs 55 Fe NI: ~20hrs 90 Sr Conclusion? Is there a steeper slope when we heat ? 11 days heating +3 days flushing Heidelberg 17 days heating
19 Oct Summary HD – NIKHEF data HD: ~90hrs 55 Fe Mod 20 and Mod 7 heated Mod 7: 186 hr irradiation! NI: ~20hrs 90 Sr Mod 20+7 have steeper slope?? NB: Mod 7 2x the irradiation Mod 7 Mod 20
19 Oct m Module: an oldy… What is the 3.2m module? Construction date: 2001 Used in 2001 testbeam for TDR Straws glued to panels with Araldite or Stycast?? 16 channels connected LHCb
19 Oct Irradiating 3.2m Mod 20 hrs hrs 23 hrs 118 hrs Gas flow Two irradiations, 2 mCu 44 hrs 118 hrs very little damage 164 hrs
19 Oct Irradiation 3.2m Mod very little damage 3.2m: 15% after 200hrs Mod3: 35% after 200hrs Progressing in time Independent of definition Compare to F-mod 3: 3.2 m module (2001):