Safety Consolidation in and around the Injector chain* S Baird On behalf of R Brown, V Chohan, J-L Duran-Lopez, B Linseisen, R Steerenberg, F Szonsco (for.

Slides:



Advertisements
Similar presentations
Museum Presentation Intermuseum Conservation Association.
Advertisements

1 According to PETROSAFE safety policy, the company is keen that: Introduction All Egyptian Petroleum companies and foreign companies working in A.R.E.
Emergency Action Plans
Safety and Health Management Program
HSE’s Ageing and Life Extension Key Programme (KP4) and Human Factors
CERN TS Department / Civil Engineering Group 8 February 2008 Civil Engineering Layouts & Tunnel Cross Section 1 CLIC/ILC Collaboration Meeting 8 Feb 2008.
ODH Fans and Work Planning Protecting Against the Big Event 10 Questions Before Starting a Job at C-AD Photo of the Week Collider-Accelerator Department.
Emergency Evacuation.
13 Oct 2005 ICALEPCS RAMSES: The LHC RAdiation Monitoring System for the Environment and Safety G. Segura CERN on behalf of the RAMSES team.
PEP-II Ramp Down to a Minimum Maintenance State J. Seeman DOE PEP-II Ramp Down-D&D Review August 6-7, 2007.
Safety aspects: electrical and gas safety, Cs handling, radiation & fire protection Matthias Kronberger, Mats Wilhelmsson On Behalf of the Linac4 ion source,
W504 - Management of asbestos containing materials.
H IGH L UMINOSITY LHC WP1 - CERN S AFETY R EQUIREMENTS Stefan Roesler - Phillip Santos Silva – Ralf Trant EDMS# HSE Unit April 2011.
Christophe Delamare EDMS Accelerator Consolidation Workshop GS/ASE activities.
Pipeline Qra Seminar Title slide Title slide.
Interaction of ST & TIS in matters of safety Mandate & OrganisationMandate & Organisation InteractionsInteractions Basis for cooperationBasis for cooperation.
Michael P. Andrews NuMI Shutdown & Facility Coordinator LBNE Project ESH Manager AD ESH Special Projects Coordinator.

CV activities on LHC complex during the long shutdown Serge Deleval Thanks to M. Nonis, Y. Body, G. Peon, S. Moccia, M. Obrecht Chamonix 2011.
CLIC CES Webex 12 Nov Summary: – Set of fire safety measures defined in CERN Safety Report – Proposed Structure for CLIC/ILC Fire Safety Report Fabio.
Consolidation of access systems for the injector Complex ATOP days 4-6 March 2009 P. Ninin & R, Nunes in behalf of the PS and SPS access project teams…
Joint ILC/CLIC Safety document ► Incentive for this document:  Share effort to define a coherent safety protocol for future linear colliders.  Insure.
TS Department / Civil Engineering Group 17 October 2007 Civil Engineering Layouts & Tunnel Cross Section 1 CLIC workshop – Working group: Two beam hardware.
ASSURANCE PINNACOL ASSURANCE Wants you to know about : EMERGENCY/DISASTER PREPAREDNESS.
Hazards Identification and Risk Assessment
CLIC CES Meeting 14 jan 2009 A resume table for fire safety in LHC, and a possible scheme for other machine – part 1 CERN –SC Fabio Corsanego.
July LEReC Review July 2014 Low Energy RHIC electron Cooling Edward T. Lessard ESHQ.
Radiation Protection considerations concerning a future SPS dump design Helmut Vincke DGS-RP.
MG - IEFC meeting 22/01/20101 Linac 3 shielding S. Gilardoni, M. Giovannozzi, S. Baird, R. Brown, S. Damjanovic, T. Otto, M. Widorski, Acknowledgements:
Status Report from LHC Safety System Task Force Emmanuel Tsesmelis / TS-LEA on behalf of the Task Force LEAF 11 May 2007.
CLIC Implementation Studies Ph. Lebrun & J. Osborne CERN CLIC Collaboration Meeting addressing the Work Packages CERN, 3-4 November 2011.
RSSO refresher meeting J. Pedersen M. Tavlet, T. Otto.
This Project is funded by the European Union Project implemented by Human Dynamics Consortium This project is funded by the European Union Projekat finansira.
ST/MAforLHC April 2003Sixth ST workshop1 Summary of ST/MA deliverables for LHC Luigi Scibile for the ST/MA group.
© Module 4—Hazard Prevention and Control Safety Management Worksite Analysis Management Commitment and Employee Involvement Hazard Prevention and.
Building 867 Project TE/MPE workshop status and schedule Presented by Tony Fowler, TE-ABT on behalf of the Project Team 28/09/2010Building 867 Project:
Work Effort in the LHC Injector Complex for the Upgrade Scenarios B. Mikulec Thanks to all the valuable input from the LIU project leaders and LIU work-
How to keep the Injectors running for another 25 years S Baird (on behalf of EN/MEF/ABA) LHC Performance workshop Chamonix January 2010.
LS2 Safety Thomas Otto, LS2 Safety Coordinator.
ISOLDE Activities for LS2 Richard Catherall EN-STI ISOLDE Technical Coordinator.
Radiation Protection aspects for SHIP Doris Forkel-Wirth, Stefan Roesler, Helmut Vincke, Heinz Vincke CERN Radiation Protection Group 1 st SHIP workshop,
Overview of the main events related to TS equipment during 2007 Definition Number and category of the events Events and measures taken for each machine.
12th February 2010David Mcfarlane EN-MEF-ABA1. History of Booster The accelerator was built in The Proton Synchrotron Booster is the first, in the.
FACILITIES MAINTENANCE PLANNING
Risk Analysis P. Cennini AB-ATB on behalf of the n_TOF Team  Procedure  Documents in preparation  Conclusions Second n_TOF External Panel Review, CERN,
Last but not least : LS2 General Safety 1 Thomas Otto, LS2 Safety Coordinator for LHC Ana-Paula Bernardes, LS2 Safety Coordinator for Injectors.
EUROnu Costing Workshop May 2011 Beta-Beam Costing Exercise Elena Wildner, CERN 25/05/11 1 EUROnu Costing Workshop, CERN May 2011.
Extraction and beamline progress B.Goddard TE/ABT.
Safety in LS1 Thomas Otto, TE DSO.
CERN Jan 2006 Specific safety Issues for 2006 compared to 2004 P. Cennini AB Safety Requirement in case the Installation activities are going on.
Interface of FP420 to LHC FP420 meeting 28-Sep-2006.
Proton-Driven Plasma Wakefield Acceleration CERN Project Structure Edda Gschwendtner, CERN Lisbon Meeting, 22 June 2012Edda Gschwendtner, CERN2.
Health & Safety in Construction 4A7 Design & the Built Environment John O’Connor.
Linac4 Project Meeting 1/2011 3/3/2011 M. Vretenar Update on schedule and structure 1.
OHSAS Occupational health and safety management system.
BY FRANS WILBRINK WILBRINK & ASSOCIATES. OUTLINE Classify the different types of hazardous areas Identify the risks associated with each of these areas.
Work by contractors And Safety Coordination CONTRACTORS ’ ACTIVITIES What is the role of TSOs when contractors are working in their area? HSE Unit - Olivier.
Follow-Ups and Project Structure R2E Meeting September 8th Project / Study Group / RadWG R2E Mitigation Project:  Responsible of development and implementation.
- HEMIC Facility Inspections. Common Losses A fire breaks out in a 16 story office building An employee had the tips of two fingers amputated Could these.
1 How Many Protons can we afford to loose in the PS ? Thomas Otto SC-RP.
LS1 Day: The Injectors S. Baird EN/MEF Thanks to R Brown, N Gilbert, D McFarlane & V Chohan, IEFC workshop…. LS1 Day: The Injectors 1.
LS2 Safety Preparation Thomas Otto, LS2 Safety Support Officer for LHC
Safety in Construction and Upgrade Phases
HEL – Safety aspects Christelle Gaignant
Radiation protection of Linac4 M. Silari Radiation Protection Group
Quality Assurance applied to Accelerator Safety
Cryogenic Risk Assessment in LHC
Workshop on Accelerator Operations
IS&LEBT Commissioning Review Safety and Radiation Protection
Presentation transcript:

Safety Consolidation in and around the Injector chain* S Baird On behalf of R Brown, V Chohan, J-L Duran-Lopez, B Linseisen, R Steerenberg, F Szonsco (for PS Safety review) T Otto & the PS Radiation Working Group (PSRWG) P Bonnal (Risk analysis procedures) * Safety Consolidation at the PS

Safety Consolidation at the PS

In view of the decision to keep the PS as LHC Injector for 25 years* PS Safety review (F Szoncso) – Snapshot of the situation today – Aiming to identify Hazards Risk analysis (P Bonnal) – Establish a prioritized action list for risks identified by the PS Safety Review Input from the PS Radiation Working Group (T Otto) – Evaluation of beam intensities and loss rates – Identification of main radiation hazards – Impact on operations & tunnel interventions – Recommendations * Decided after Chamonix 2010

PS Safety review Mandated by S Myers & R Trant to: – ‘establish the facts related to the safety of the CERN PS and assess the safety compliance of the PS in view of it’s long-term operation as LHC injector’ Members: EN/MEF, HSE, BE/OP, TSO Aim to identify hazards whilst avoiding any prejudgment – Groups involved in the operation, maintenance, modification and emergency handling at the PS were contacted individually – Standard questionnaire plus specialized questions – Report the situation as it is today (as seen by those intervening in the tunnel) The results can be found in the CERN Proton Synchrotron Safety Review –

PS Safety Review: Teams contacted Civil Engineering, buildings, tunnel structures Services: Tunnel cooling and ventilation, Electricity, Cabling, Transport Beam related equipment: Vacuum, RF, Beam instrumentation, Kickers & Septa, Magnets Safety systems: Interlocks, Access and Safety systems, Fire Brigade, Environment Shutdown Coordination

PS Safety Review: Hazards indentified 1/2 41 potential hazards identified including… – Asbestos pipe insulation – Safety communication for personnel intervening in the tunnel (CERN and external contractors) – Leakage of air from the tunnel, smoke extraction system has no filter, problems to maintain constant pressure differentials in the tunnels – Possibility of corrosive smoke in case of fire (cables, batteries…) – No flooding warning interlock in presence of pressurized water systems – HV is present on ion pumps permanently (during access) – Many of the procedures for testing magnets and other elements rely on expert knowledge and not written instructions

– Cable deterioration due to radiation, overfilled cable trays & un- identified cables – Lack of building/tunnel maintenance (leaks, water infiltrations) – Some walkways and stairs are unsuitable and difficult to use – Tunnel concrete floor slabs damaged – The AUG layouts and the action of individual buttons are not clear – Few systems have individual emergency stop buttons (not coherent approach) – Lack of safety exercises and evacuation drills – Radiation issues are covered by the PSRWG PS Safety Review: Hazards indentified 2/2

Prioritizing risk mitigation measures « PS Safety Review » of Feb Risk Mitigating actions Prioritized list of risk mitigation measures Possible measures that will most improve outstanding safety issues  Top of the list Actions that are to be taken within budgetary limits

Identify all safety risks from the hazards listed in the PS Safety Review Report Evaluate those risks from to 2 perspectives: – Probability of occurrence – Impact on health, safety and environment Analyze those risks: – List the existing mitigation measures (already in place): Preventive measures (  probability) Protective measures (  impact) – List possible additional mitigation measures – Estimate their feasibility (cost, manpower, schedule…). Risk = P × I Evaluation and analysis phase

Review existing mitigation measures, i.e. those already in place (risks are weighed taking these measures into account) 1 st ranking (before new measures are implemented) sorting = from highest risk to lowest risk Identify additional mitigation measures (incl. their cost estimate, the manpower required, their feasibility from a schedule point of view…) Risks are then re-weighed considering the implementation of these additional mitigation measures 2 nd ranking (after new measures are implemented) sorting = from highest risk improvement to lowest.

PSRWG: PS Beam Intensities and Loss IntensityRelative LossLoss rate Injection s -1 6 % s -1 Extraction (high.int. beams) s -1 CT10 % s -1 MTE1 – 2 %Up to s -1 The PSRWG evaluated beam intensities and loss rates for 2010 operation of the PS. This allowed a correlation between beam loss and the observed radiation hazards Average/supercycle Calculated from intensity & loss Not including nTOF, LHC, EAST HALL

Main Radiation Hazards in PS HazardMain LocationsConcernMitigation* Air activationWhole PS, numerous pathways Release to environment, radiation dose to workers and public Assessment to demonstrate negligibility Stray radiationRoute Goward Downstream of South-hall External irradiation of personnel on- site and of public Shielding Activation of material in the tunnel SMH16 (MTE) Downstream SEH31 (CT) External irradiation of workers during access Allow decay time * other than reduction of beam loss Not measured today

Activation: Ambient dose rates limit the possibility for urgent interventions 14 days Solutions: Hardware upgrade to allow remote handling Wait longer (unrealistic due to logarithmic decay characteristics) Reduce and/or constrain beam loss 14 days after accelerator stop: H*(10)  20 mSv h -1 Septum exchange possible without breaking internal RP rules E.g. Replacement of SMH16

PSRWG Recommendations (1) Air activation – Cost an upgrade of ventilation allowing proper assessment of releases, in terms of CHF and of person-mSv – Take an informed decision Stray Radiation – Homogenise radiation shielding on top of PS, allowing for probable intensity upgrades: Linac 4 and 2 GeV PS Booster at full capacity – cm earth downstream of South-Hall – +180 cm concrete on Route Goward

PSWRG Recommendations (2) Accelerator Activation – Reduce loss focalized on SMH16 by various means (dummy septum, barrier buckets, …) – Introduce a beam loss constraint for routine operation: < s -1 at any location (without septa) < s -1 at septa < s -1 overall – These constraints allow major interventions after a breakdown (magnet or septum exchange) with 14 days decay time

Actions for the future Hazards identified in the PS Safety review – Risk analysis to assess the hazards identified and produce a set of prioritized actions – Implement inside an Injector Consolidation program? PSRWG – Modify ventilation system to allow measurement of air activation – Additional shielding requirements identified – Remote handling for certain elements? – Reduce localized losses with “technical or beam” solutions – Use a beam loss constraint rather than an extracted intensity limit

Questions asked 1/3 Do you believe that your equipment is operationally safe today? What risk does your equipment pose for the safe operation of the PS? Does your equipment pose any safety issue to other personnel? Do you believe your equipment will degrade in terms of safety and will require replacing or even redesigning? How could your equipment be improved to make it safer than it is today? When making interventions on your equipment, do you consider the procedures you follow today are safe? To make your interventions safer, what procedures should be improved?

Questions asked 2/3 Do you consider the PS tunnel to be a safe working environment? What elements of the tunnel do you consider to be either unsafe or a potential risk to your health and safety? Do you consider any other PS hardware to be unsafe? Are you aware of any environmental issue in the PS that should be addressed? Are you and your team fully aware of the emergency equipment and procedures while working in the tunnel? – Emergency exits? – Emergency lighting? – Emergency phones and numbers? – Emergency stop buttons (AUG)? – Fire fighting equipment? Extinguishers, what type and how to use them?

Questions asked 3/3 Specific questions…. – Can beam losses affect your equipment? – Does induced radio-activity affect interventions on your equipment? – Is your equipment protected by specific interlocks? – Do you use/store dangerous chemicals/materials – Do you have dangerous systems which must remain on during a shutdown period? – Is the tunnel equipped with smoke extractions systems? – Do your equipment present a particular fire risk? – How is the AUG system laid out? – …………….