PXISA Jet Engine DAQ Simulation/Demo Measured Engine Parameters: Temperatures, Pressures, Flow, RPM, ARINC-429 864 total channels in a single chassis Compact.

Slides:



Advertisements
Similar presentations
Georgia Tech Digital Back-end µHRG interface Curtis Mayberry School of Electrical and Computer Engineering Georgia Institute of Technology January 13 th,
Advertisements

PXI 总线技术. Overview PXI/CompactPCI Architecture Mechanical Electrical Software 3rd Party Support PICMG PXI Systems Alliance Configuring a PXI System Products.
Inc. Supplier Presentation Loofie Gutterman Geotest – Marvin Test Systems, Inc. (Automatic Test Equipment (ATE) Standardization and Commercialization)
Data Acquisition Risanuri Hidayat.
1 RIO Pocket PLC. 2 Smart. Compact. Low Cost. Lots of I/O. Smart – RISC processor, memory, pulse counters, PID process loops, web interface, capability,
STARLight PDR 3 Oct ‘01I.1 Miller STARLight Control Module Design Ryan Miller STARLight Electrical Engineer (734)
Bradley University Department of Electrical and Computer Engineering 2011 Wind Tunnel Control (WEBWIND) By: Adam Green Advisor: Dr. Aleksander Malinowski.
Data Acquisition Hardware By Joe Eastman. 3-Feb-03Joe Eastman Types of Hardware PCI and ISA Boards PCMCIA Cards USB Serial Port.
FOLLOWER SENSORS AND ACTUATORS EE 552 INTSTRUCTOR :Dr MOHAN KRISNAN BY MOHAMMED KASHIF IQBAL ANESH BODDAPATTI UNIVERSITY OF DETROIT MERCY.
Aloha Proof Module Design Cabled Observatory Presentation School of Ocean and Earth Science and Technology February 2006.
Arduino Week 3 Lab ECE 1020 Prof. Ahmadi. Objective Data acquisition (DAQ) is the process of measuring an electrical or physical phenomenon such as voltage,
Diamond D10 Test Platform
ASPPRATECH.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
Introduction to the Raw Handheld Board Jason Miller, David Wentzlaff, Nathan Shnidman.
EtherCAT Driver for Remote I/O James Rowland, Ronaldo Mercado and Nick Rees.
Who is National Instruments? Culture & Philosophy 3 Decades of Products A closer look at current Products The Next Decade.
Moore’s Law and Modular Instrument Technology Speaker/Author:Paul Packebush Senior Group Manager Corporate Metrology, R&D National Instruments N.
Keep it Cheap: EPICS Devices for the Small Laboratory
Data Converters ELEC 330 Digital Systems Engineering Dr. Ron Hayne
DATA ACQUISITION Today’s Topics Define DAQ and DAQ systems Signals (digital and analogue types) Transducers Signal Conditioning - Importance of grounding.
WaveBook, Personal Daq, and DaqBoard/3000 USB Overview John Rys Product Support Engineer.
Industrial Automation T Rajendran. Industrial Automation  Control Systems  Process Control  Industrial Control  Computer Integrated Manufacturing.
DAQ Cards, or Instruments The purpose of this presentation is to familiarize new Lab View users to the different computer aided test recourses available.
A new class in PC Data Acquisition Delphin Technology AG Felix Ottofuelling V5.0.
Embedded device set for control systems. Implementation and application. Victor R. Kozak BINP, Novosibirsk, Russia Budker INP, Novosibirsk RuPAC-2006.
Measurement Fundamentals Rajesh Vaidya DAQ Software Engineer Wed 10:15a, 12:45p, and 3:30p Colorado (6A) Rajesh Vaidya DAQ Software Engineer.
XFEL The European X-Ray Laser Project X-Ray Free-Electron Laser Tomasz Czarski, Maciej Linczuk, Institute of Electronic Systems, WUT, Warsaw LLRF ATCA.
15 March 2001Absorber Review Meeting at NIU1 DAQ for Pressure Test, and later... Michael J. Haney University of Illinois
Rl/ic/ukdmc cPCI - DAQ for NaI Crystals. rl/ic/ukdmc DC MS/s (*) Sampling Rate simultan. on all channels 150 MHz (*) Bandwidth 128 kpoints per.
Hardware Architecture A. Voto, I. Dai, P. Oleniuk, B. Todd Standardisation of Automated Industrial Test Equipment for Mass Production of Control Systems.
Multiplexers and De-Multiplexers 1
ECE 353 Introduction to Microprocessor Systems Michael G. Morrow, P.E. Module #7 Assessment Quiz.
PXI Systems - Discussions Gueorgui ANTCHEV / EP-ESSEPTAB Meeting February 2003Slide 1 of 3 PXI = Compact PCI + eXtensions for Instrumentation PXI is an.
Industrial Controls Engineering Department First CERN PXI Users Group meeting 19 th October 2011 – Hubert REYMOND – EN/ICE 1.
Comparators, DAC, and ADC
Multiplexers and De-Multiplexers
Notes on visit to Rome 28/04/2014 Christian Joram Szymon Kulis Samir Arfaoui.
A Presentation on Mr. SAJID NAEEM M.SC – Electronics (UOP) PG-DEP (C-DAC)
PXI-Based Hybrid Test Systems Nick Hickford UK Sales Manager, Pickering Interfaces
Humidity Meter | Digital Counter | pH Controller.
ECE 101 Exploring Electrical Engineering Chapter 7 Data Acquisition Herbert G. Mayer, PSU Status 11/30/2015 Derived with permission from PSU Prof. Phillip.
Institute of Applied Astronomy Third International VLBI Technology Workshop, Groningen/Dwingeloo, Netherlands, November 10-13, 2014 Current State of Russian.
Hall B Gas System Controls Physics Detector Support Group.
WORLD PC-BASED TEST AND MEASUREMENT EQUIPMENT STUDY Study Definition: ‘PC cards that are plugged into slots inside the computer or into PC bus expanders,
Fast Digitizers ACAS Workshop, December 2010 Greg Tate Agilent Technologies Asia-Pacific Business Manager Modular Product Operations.
High Voltage Power Supply for RPC Suvendu Nath Bose, Satyajit Saha, Sudeb Bhattacharya, Saha Institute of Nuclear Physics, Kolkata,, Description Presently.
Front End. Charge pre-amp and detector Voltage regulator. TOP side. Detector linear voltage regulator BOTTOM side. Charge pre-amp.
Arduino Week 3 Lab ECE 1020 Prof. Ahmadi. Objective Data acquisition (DAQ) is the process of measuring an electrical or physical phenomenon such as voltage,
1 MIPI Interfaces in a Mobile Platform This picture is only an illustrative example for several ways of integration with the purpose of demonstrating.
DAQ ACQUISITION FOR THE dE/dX DETECTOR
Intro to USB-6009 DAQ.
Setup for automated measurements (parametrization) of ASD2 chip
RF acceleration and transverse damper systems
@ Professor Doug Harper Department of Physics and Astronomy
SCADA for Remote Industrial Plant
PSD Front-End-Electronics A.Ivashkin, V.Marin (INR, Moscow)
Ewald Effinger, Bernd Dehning
Disc Thickness Measurement System
Engineering Technology Division
Introduction.
Lecture 15 Computer Data Acquisition Systems
VELO readout On detector electronics Off detector electronics to DAQ
Status of Fast Controller EPICS Supports for ITER Project
הודעות ריענון מהיר והרחבות דגימת אות Low-Level
asyn Driver Tutorial Measurement Computing 1608GX-2A0
Data Acquisition (DAQ)
Straw tubes for LoKI Davide Raspino IKON
Programmable Interval Timer
Dr. Fred Bloennigen CEO, BUSTEC
Presentation transcript:

PXISA Jet Engine DAQ Simulation/Demo Measured Engine Parameters: Temperatures, Pressures, Flow, RPM, ARINC total channels in a single chassis Compact PXI platform – 3U & 6U Six PXI Vendors: KineticSystems GaGe Keithley Geotest ADLINK National Instruments

PXISA Jet Engine DAQ Simulation/Demo Equipment Shown in Demo: –KineticSystems 2x – CP387: High-density Digital I/O (6U) 2x – CP213: 64-ch, 16-bit Scanning ADC with Signal Conditioning (6U) 1x – CP266: 64-ch, 16-bit DAC (6U) 1x – P580: 34x2 Scanning Differential Relay Multiplexer (3U) 1x – P635: 8-ch Frequency Counter with Signal Conditioning (3U) 1x – V765: Termination Panel 1x – V792: Isothermal Termination Panel –GaGe 1x – CS14100C: 2-ch, 14-bit, 100MHz Digitizer (6U) –Keithley 1x – KPXI-DAQ-96-3M: Multifunction DAQ (3U) –Geotest 1x – GX7100A: 3U/6U Combo Chassis 1x – GX E: Embedded 1.7GHz P4 / 512MB PXI Processor (6U) –ADLINK 1x – cPCI-8554: Counter/Timer (3U) –National Instruments – LabWindows CVI

PXISA Jet Engine DAQ Simulation/Demo Channel Matrix Mfg. / ModelADCDACDigital I/O FreqTimerCounterRelayDigitizerSignal Conditioning KS CP KS CP KS CP KS CP Gain/Filter KS CP Gain/Filter KS P KS P635 8 Gain/Filter GaGe CS14100C 2Gain Keithley KPXI-DAQ-96-3M Gain AdLink cPCI Summary:Differential ADC Channels with Gain/Filter128 Differential ADC Channels with Gain 48 Differential DAC Channels 64 Digital I/O Channles568 Frequency Counter Channels with Gain/Filter 8 Relay Switches 34 Digitizer Channels 2 Counter/Timer Channels 12 Total Channel Count:864

PXISA Jet Engine DAQ Simulation/Demo KineticSystems 64-ch, 16-bit, Scanning ADC CP213 (6U) Software: LabWindows CVI 3U/6U PXI Chassis: Geotest 7100A Processor: Geotest GX E (1.7GHz P4/512MB Embedded PXI Processor) KineticSystems 64-ch, 16-bit, Scanning ADC CP213 (6U) KineticSystems 256-ch Digital I/O CP387 (6U) KineticSystems 256-ch Digital I/O CP387 (6U) KineticSystems 64-ch, 16-bit DAC CP266 (6U) KineticSystems 8-ch, 100KHz Frequency In P635 (3U) KineticSystems Relay Multiplexer P580 – 3U Keithley Multi- function DAQ KPXI-DAQ- 96-3M (3U) GaGe 2-ch, 100MHz Digitizer CS14100C – 6U ADLINK Counter / Timer cPCI-8554 – 3U