All rights reserved MV SWITCHGEAR.

Slides:



Advertisements
Similar presentations
Introduction to Switchgear
Advertisements

MEP201 Mechanical Engineering Drawing 1st semester
Gdpack 40.5kV Technical Data Sheet MV-LV Prefabricated Substation
1S25 Arc Fault Monitor. 1S25 Arc Fault Monitor 1S25 Arc Fault Monitor Electrical arc short circuits in metal clad switchgear may occur for many different.
Tuesday 13 th December 2005 Substation SB400. Final testing in 10Kv substation.
UniGear type ZS2 Product Presentation
G GE Power Management DDS Integrated P&C System INTGRATED PROTECTION AND CONTROL SYSTEM DDS INTEGRATED PROTECTION INTEGRATED CONTROL.
SHS2 Gas insulated switch–disconnector / isolator
ACADs (08-006) Covered Keywords Switchgear, motor control, ground, circuit breaker. Description Supporting Material
EVD4 - The Smart eVolution Primary distribution circuit-breaker with integrated protection, control and sensors © ABB Group 15. April 2017 | Slide 1 1.
Electrical Systems Electrical Engineering in Railways –Rolling Stock –Communications & Control –Signalling –LV Installations in Stations and Buildings.
GE Consumer & Industrial Multilin  Single & Three phase models  Specific mount CT’s  Rectangular & Toroidial models  Plastic case & cast models  Multi.
Breaker Basics Welcome to this general overview of ABB.
EE4503 Electrical Systems Design
Unit Transformer Unit transformer are step up transformer which is connected to generating house & step up voltage from 15kV voltage to 132 voltage level.
MaxSG - Low Voltage Switchgear
Medium Voltage Switchgear
WFR-12~24 Product presentation
UniGear ZVC Standard Product
PRESENTATION ON SUBSTATION DESIGN
ABS Ennin, George Coleman, David Dadson & Anthony Ansah
The Home Inspection Book: A Guide for Professionals By Marcia Darvin Spada Copyright, Thomson/South-Western, 2003, Revised, 2006.
Motor Control Center MNS iS with Condition Monitoring
Unit-3 SUBSTATIONS.
THE ELECTRIC SUB STATION
TF Joint Voltage Drop Instrumentation Robert Marsala (609) Hans Schneider (609) Engineering Operations August 7, 2003 TF_JOINT_Final_Design_Review.ppt.
All rights reserved Gas-insulated Switchgear (GIS)
Electrical Materials Continued. Powering your home Homes in Ontario now have Smart Meters, these meters keep track of how much you use and when. The idea.
Sepam case studie EN 2007_01.ppt1 Installation single-line diagram G M Transformer 63KV / 6.3KV 10MVA Generator 2MVA 30A / 5s 6A continuous 1 CSH 30A /
Power Plant Construction and QA/QC Section 4.4 – In-Plant Electrical Distribution Engineering Technology Division.
PowerIT Air Insulated Cubicle Uniswitch
Consumer’s Main Switchroom & Main L.V. Switchboard
POWER HOUSE.
Introduction to switchgears
A PRESENTATION OF PRACTICAL TRAINING ON “400KV GSS “ \
A SUMMER TRANNING PRESENTATION ON 400 KV GRID SUB STATION BIKANER
A Presentation On 132 KV GSS BEHROR
Submitted to: Submitted by:
PRACTICAL ELECTRICAL ENGINEERING BASICS
SUBSTATION LAYOUT AND ACCESSORIES
SEMINAR PRESENTATION ON 220 KV GSS UDAIPUR
Department of Electrical Engineering
A Training Presentation On 220 KV GSS CHOMU,JAIPUR
A Training Presentation On 132 KV GSS JAIPUR Submitted in partial fulfillment For the award of the degree of BACHELOR OF TECHNOLOGY Submitted To:- Submitted.
220 KV GRID SUB STATION MORAK,KOTA SUBMITTED TO:- SUBMITTED BY:- SHRI VIKAS BHALLA LAKHAN SINGH ASSISTENT PROFESSOR ROLL NO.-12ECTEE029 ELECRTICAL DEPARTMENT.
132KV GSS PIPAR CITY JODHPUR
Evolution and Prospects of Relay Protection and Automation Systems Evolution and Prospects of Relay Protection and Automation Systems Moderator: Janez.
A SEMINAR ON 400 KV GSS(RRVPNL) BIKANER.
Submitted To:- Submitted By:- Mr.
Switchgear for Primary Distribution
Presentation Topic: Circuit Breakers Represented to: Dr. M. Riaz Khan Represented by: M. Mujahid.
This project on Primary sub station of Visakhapatnam port trust at Visakhapatnam. It is 132kv/11kv substation with incoming feeder from APTransco and 11.
5SL4 10 kA / 5SL6 6 kA miniature circuit breakers
ELECTRICAL INSTRUMENTS ( service and utilization )
Gas-insulated switchgear type ZX0
P2 - Physics Mains Electricity
SYNERGY INSTITUTE OF ENGINEERING AND TECHNOLOGY
AUTOMATIC CIRCUIT RECLOSER
Electrical Current & Circuits. Components of an electrical circuit Source of electrical energy (battery) A conductor of electrical energy (wire) Device.
6 Week industrial Training Presentation
STUDY OF ELEMENTS OF A 220/132/33KV SUBSTATION
SINGLE LINE DIAGRAM.
Overview of PowerCube Units and ANSI frames
NEC Wiring Diagrams.
Introduction to IEC/TR A status update and insides
All rights reserved Gas-insulated Switchgear (GIS)
P2 - Physics Mains Electricity.
Substation Equipment's
DIPLOMA In ELECTRICAL ENGINEERING DEPARTMENT OF ELECTRICAL ENGINEERING GOVERNMENT POLYTECHNIC COLLEGE, HANUMANGARH Sept A Training Presentation On.
Presentation transcript:

All rights reserved MV SWITCHGEAR

All rights reserved STANDARDS IEC High-voltage switchgear and controlgear – AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV

All rights reserved Metal-enclosed Switchgears Busbar Compartment Circuit Breaker Compartment Cable Compartment LV Compartment

All rights reserved Circuit Breaker Compartment

All rights reserved Main busbar system Branch busbar connections Through insulators for segregation of neighboring busbar compartments Busbar Compartment

All rights reserved Earthing switch Busbar branch connections Power cables Surge arresters Instrument transformers (current transformers, voltage transformers) Cable Compartment

All rights reserved Microprocessor relay protection Automation and SCADA elements Auxiliary wiring (control, supply, signalling circuits) Transit auxiliary wiring Local control and signalling elements Low-Voltage Compartment

All rights reserved Internal Construction 1 Circuit Breaker compartment 2 Main busbar compartment 3 Cable compartment 4 LV compartment 5 Arc duct/channel 6 Current transformers 8 Earthing switch 7 Voltage transformers

All rights reserved Internal Arc Protection Front Protection Rear Protection Lateral Protection Release of hot gases from each compartment in case of internal arc fault

All rights reserved Single Line Diagram

All rights reserved IF & OF – Incoming & Outgoing Feeder 6 Cables Withdrawable VT Fixed VT + 6cables

All rights reserved BC – Bus Coupler Left/Right Versions

All rights reserved BR – Bus Riser Metering Version With VT Truck Version With No VT Truck

All rights reserved Rating

All rights reserved Gas-Insulated Switchgear

All rights reserved Panel Components

All rights reserved IF & OFBC + BR Single Line Diagram