Recent Progress in X-ray Emittance Diagnostics at SPring-8 S. Takano, M. Masaki, and H. Sumitomo * JASRI/SPring-8, Hyogo, Japan SES, Hyogo, Japan *

Slides:



Advertisements
Similar presentations
R. Nagaoka, A. Nadji, M.E. Couprie, O. Marcouillé
Advertisements

Richard M. Bionta XTOD October 12, 2004 UCRL-PRES-XXXXX X Ray Transport, Optics, and Diagnostics, Overview Facility Advisory Committee.
Two-dimensional and wide dynamic range profile monitor using OTR/fluorescence screens for diagnosing beam halo of intense proton beam Y. Hashimoto, T.
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
U. Iriso, A. Nosich, and L. Torino Accelerator Division, CELLS May 2014 Beam Size Measurements at ALBA.
AWAKE Electron Spectrometer Design Simon Jolly 4 th September 2012.
Matching and Synchrotron Light Diagnostics F.Roncarolo, E.Bravin, S.Burger, A.Goldblatt, G.Trad.
LEPP, the Cornell University Laboratory for Elementary-Particle Physics, has joined with CHESS to become the Cornell Laboratory for Accelerator-based Sciences.
AC dipole for LHC Mei Bai Collider Accelerator Department Brookhaven National Laboratory.
Searching for Quantum LOVE at the Australian Synchrotron Light Source Eugene Tan On behalf of Rohan Dowd 120/10/2010Eugene Tan – IWLC 2010, Genega ASLS.
Beam Instrumentation for Orbit Stability I. Pinayev.
Ultra-Low Emittance Storage Ring David L. Rubin December 22, 2011.
Electromagnetic radiation sources based on relativistic electron and ion beams E.G.Bessonov 1.Introduction 2.Spontaneous and stimulated emission of electromagnetic.
June 14th 2005 Accelerator Division Overview of ALBA D. Einfeld Vacuum Workshop Barcelona, 12 th -13 th September 2005 General 10 th September 2005.
BROOKHAVEN SCIENCE ASSOCIATES BIW ’ 06 Lepton Beam Emittance Instrumentation Igor Pinayev National Synchrotron Light Source BNL, Upton, NY.
Transverse emittance Two different techniques were used to measure the transverse emittance. The multislit mask in the injector 9 MeV Quadrupole scan for.
Optical diagnostics for beam halo (I) Coronagraph (II) OTR halo monitor for J-PARC T. Mitsuhashi, KEK.
Eusoballoon optics test Baptiste Mot, Gilles Roudil, Camille Catalano, Peter von Ballmoos Test configuration Calibration of the light beam Exploration.
XBSM Analysis - Dan Peterson Review of the optics elements: Pinhole (“GAP”), FZP, Coded Aperture Extracting information from the GAP what is the GAP width?
05/05/2004Cyrille Thomas DIAMOND Storage Ring Optical and X-ray Diagnostics.
1 2. Focusing Microscopy Object placed close to secondary source: => strong magnification The smaller the focus, the sharper the image! Spectroscopy, tomography.
October 4-5, Electron Lens Beam Physics Overview Yun Luo for RHIC e-lens team October 4-5, 2010 Electron Lens.
Direct Observation of Ultralow Vertical Emittance Using a Vertical Undulator Kent P. Wootton The University of Melbourne.
Developments of Photon Beam Monitors in NSRRC (TLS) J.R. Chen, C.K. Kuan, T.C. Tseng, and G.Y. Hsiung National Synchrotron Radiation Research Center XBPM.
C. Fischer – LHC Instrumentation Review – 19-20/11/2001 Gas Monitors for Transverse Distribution Studies in the LHC LHC Instrumentation Review Workshop.
FFAG-Workshop Dec Kumatori Japan Diagnostics for FFAG- accelerator Takahisa ITAHASHI Department of Physics, Osaka Univ. Toyonaka, Osaka, ,Japan.
High resolution X-ray analysis of a proximal human femur with synchrotron radiation and an innovative linear detector M.Bettuzzi, R. Brancaccio, F.Casali,
A U.S. Department of Energy Office of Science Laboratory Operated by The University of Chicago Argonne National Laboratory Office of Science U.S. Department.
1 BROOKHAVEN SCIENCE ASSOCIATES Storage Ring Commissioning Samuel Krinsky-Accelerator Physics Group Leader NSLS-II ASAC Meeting October 14-15, 2010.
Development of a Gamma-Ray Beam Profile Monitor for the High-Intensity Gamma-Ray Source Thomas Regier, Department of Physics and Engineering Physics University.
SPATIAL RESOLUTION OF NON- INVASIVE BEAM PROFILE MONITORBASED ON OPTICAL DIFFRACTION RADIATION A.P. Potylitsyn Tomsk Polytechnic University, , pr.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Overview Satoshi Ozaki Director, Accelerator Systems Division NSLS-II Project March 27, 2007.
ELECTRON MOVING AT CONSTANT VELOCITY
BSRT CALIBRATION MD SUMMARY LSWG #6-15/09/2015 BSRT TEAM.
1 H. Hayano for the ATF collaboration Low Emittance Beam Generation in ATF H. Hayano for the ATF collaboration BPM electronics improvement emittance tuning.
Vertical Emittance Tuning at the Australian Synchrotron Light Source Rohan Dowd Presented by Eugene Tan.
28-May-2008Non-linear Beam Dynamics WS1 On Injection Beam Loss at the SPring-8 Storage Ring Masaru TAKAO & J. Schimizu, K. Soutome, and H. Tanaka JASRI.
U. Iriso, A. Nosich, and L. Torino Accelerator Division, CELLS
Proposed NSLS X13B Microdiffraction Instrument Source & Optics James M. Ablett National Synchrotron Light Source.
Christoph Gabor, ASTeC HIPPI—Meeting (WP 5) 26 th – 28 th September 2007 Non—destructive transverse emittance measurement device The Front End Test Stand.
1 EMMA Tracking Studies Shinji Machida ASTeC/CCLRC/RAL 4 January, ffag/machida_ ppt & pdf.
Measurements of ultra-low emittances using a vertical undulator K.P. Wootton, G.N. Taylor, R.P. Rassool The University of Melbourne M.J. Boland, B.C.C.
Current status of the BaD-ElPh project at ELETTRA
New emittance monitor beamline
NON-INTERCEPTING DIAGNOSTIC FOR HIGH BRIGHTNESS ELECTRON BEAMS USING OPTICAL DIFFRACTION RADIATION INTERFERENCE (ODRI) A. Cianchi #1,2, M. Castellano 3,
Peterson xBSM Optics, Beam Size Calibration1 xBSM Beam Size Calibration Dan Peterson CesrTA general meeting introduction to the optics.
Argonne National Laboratory is managed by The University of Chicago for the U.S. Department of Energy Short Pulse Generation Through Beam Manipulation.
Beam dynamics in IDsBeam-based Diagnostics, USPAS, June 23-27, 2003, J. Safranek Beam Size Measurement m Survey of beam size measurement techniques and.
Calculation of the Coded Aperture zero-beam-size image (the “image”). The CA fitting procedure: The image is parameterized as a Sum-Of-Gaussians.
CESR Test Accelerator Optics Correction and Tuning Tools David Sagan Cornell University.
Angela Saa Hernandez, Martin Rohrer, Volker Schlott, Andreas Streun (PSI, Switzerland) Jonas Breunlin, Åke Andersson (MAX IV Laboratory, Sweden) Natalia.
XBSM Analysis - Dan Peterson Review of the optics elements: Pinhole (“GAP”), FZP, Coded Aperture Extracting information from the GAP what is the GAP width?
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
LCWS, UTA, Reaching ultra-low emittance at SLS through (systematic and) random optimization LCWS 2012 Joint CLIC/ILC Working Group – Damping.
Low Emittance Rings 2014 Workshop INFN-LNF, 18. September 2014 Low Emittance Studies at 3 GeV at PETRA III Joachim Keil DESY.
Workshop on Accelerator R&D for Ultimate Storage Rings – Oct Nov.1 – Huairou, Beijing, China A compact low emittance lattice with superbends for.
Beam Diagnostics Seminar, Nov.05, 2009 Das Tune-Meßverfahren für das neue POSI am SIS-18 U. Rauch GSI - Strahldiagnose.
Wir schaffen Wissen – heute für morgen PSI, March 2013 Paul Scherrer Institut PSI / DESY / KIT Mini-Workshop on Longitudinal Diagnostics for FELs.
Vertical Emittance Measurements using a Vertical Undulator K.P. Wootton, G.N. Taylor, R.P. Rassool Uni. Melbourne M.J. Boland, B.C.C. Cowie, R. Dowd, Y.-R.E.
Ultra-low Emittance Coupling, method and results from the Australian Synchrotron Light Source Rohan Dowd Accelerator Physicist Australian Synchrotron.
ESLS Workshop Nov 2015 MAX IV 3 GeV Ring Commissioning Pedro F. Tavares & Åke Andersson, on behalf of the whole MAX IV team.
G. Trad on the behalf of the BSRT team Emittance meeting 04/11/2015.
GSI IPMs.
Orbit Response Matrix Analysis
Vertical emittance measurement and modeling Correction methods
MD2243: Coronagraph commissioning at 6.5 TeV
Coupling Correction at the Australian Synchrotron
OTR based measurements for ELI-NP Gamma Beam Source
CLIC damping rings working plan towards the CDR
Diagnostics overview Beam profile monitors Cherenkov radiators Summary
Presentation transcript:

Recent Progress in X-ray Emittance Diagnostics at SPring-8 S. Takano, M. Masaki, and H. Sumitomo * JASRI/SPring-8, Hyogo, Japan SES, Hyogo, Japan *

Outline Introduction X-ray Pinhole Camera X-ray Fresnel Diffractometry Monitor (XFD) Conclusions 15 September 2015IBIC 2015 Melbourne1

Introduction Light Source Facilities are Competing to Achieve Lower Emittance and Emittance Coupling Ratio for Higher Brilliance. Serious and Elaborate Efforts are being Paid for Upgrade Plans of Existing Rings or New Plans of Low Emittance Rings. X-ray Synchrotron Radiation (SR) is Key Diagnostic Probe for Non-Destructive Beam Emittance Measurement. Both Direct Imaging and Interferometric Technique can Resolve the Micrometer-order Transverse Beam Size. Emittance is Obtained from the Measured Size with Other Knowledge (Betatron and Dispersion Functions, Energy Spread). 15 September 2015IBIC 2015 Melbourne2

Introduction Two Alternative Targets of X-ray Emittance Diagnostics at Light Source Rings Dipole Magnet Source and Insertion Device Source (Undulator) It Seems from the View Point of Machine Operation that Emittance Diagnostics of Dipole Source is Necessary and Sufficient for Tuning the Beam of the Accelerator Nonetheless, Diagnostics of Undulator Source Emittance Cannot be Avoided Because the Undulator is Just the Source of Light Delivered to Experimental Users Two X-ray Instruments for Emittance Diagnostics Recently Implemented at SPring-8 Dipole Source: X-ray pinhole camera Undulator source: X-ray Fresnel Diffractometry monitor (XFD) 15 September 2015IBIC 2015 Melbourne3

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne4 X-ray 6.24 m Source: Dipole (29B2) m m Layout

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne5 X-ray 6.2 m Source: Dipole (29B2) B = 0.5 T Ec = 21.1 keV Aluminum 3mm thick X-ray Alminum 5052 OFHC mask 1mm (H) X 5mm (V)

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne6 Pinhole 11.4 m Y slit Tungsten 3mm thick X-ray Aperture: 20  m x  m manual XZ stage rotary stage gonio stage X slit Tungsten 3mm thick

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne7 Scintillator & Camera 34.3m Mirror manual XZ stage CCD Camera (Basler piA gm) GigE interface 2448 x 2050 pixels 3.45  m x 3.45  m pixel size Lens object-space telecentric x2 magnification W. D. = 111 mm X-ray Scintillator CdWO 4 (CWO) 0.5mm thick

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne8 Resolution of Pinhole ( PSF calculation based on Wave Optics ) Pinhole Resolution (rms)  diff = 6.9  42 kev

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne9 Scintillator & Camera Assembly Resolution Calibration Resolution (rms) of Scintillator & Camera Assembly  CAM = 2.2  m sharpness of edge of W bar placed in front of scintillator measured

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne10 Total Spatial Resolution  XPC (rms) = 7.2  m Pinhole  diff = 6.9  m Scintillator & Camera  CAM = 2.2  m Scale of Camera Pixel to Beam Coordinate measured by introducing vertical bump orbits consistent with designed value  m/pixel

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne11 Projected  x = pixels Projected  y = 21.3 pixels Projected profiles (horizontal and vertical) consistent with Gaussian profiles Projected Beam Size  x = 96.0  m  y = 16.6  m (resolution subtracted) Example of data I = 100 mA, exposure time 1 ms

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne12 Control Room Display Live Beam Image View ~ 15 fps Parameters of Beam Profile beam size  x and  y beam tilt angle  Continuously Logged to SPring-8 Control Database By Periodical Image Analysis (1s cycle time) 2D Gaussian Profile is Fitted to Beam Image Data  y = 7.5 pm.rad (coupling 0.3%)

X-ray Pinhole SPring-8 15 September 2015IBIC 2015 Melbourne13 Control Room Display Live Beam Image View ~ 15 fps Parameters of Beam Profile beam size  x and  y beam tilt angle  Continuously Logged to SPring-8 Control Database By Periodical Image Analysis (1s cycle time) 2D Gaussian Profile is Fitted to Beam Image Data  y = 7.5 pm.rad (coupling 0.3%)

X-ray Pinhole SPring-8 15 September 2015 IBIC 2015 Melbourne14 Diagnostics for User Operation: Betatron Coupling induced by ID20 ID error fields excite betatron coupling in user operation. Betatron coupling is corrected by tuning skew Q parameters. gap closed skew Q correction gap opened

X-ray Pinhole SPring-8 15 September 2015 IBIC 2015 Melbourne15 Diagnostics for Machine Tuning: Betatron Coupling induced by ID10 Search for Correcting skew Q parameters Gap 6 mm Gap 50 mm (full-open) * radiation induced-demagnetization of ID10 suspected, and B field readjusted in March 2015

X-ray Pinhole SPring-8 15 September 2015 IBIC 2015 Melbourne16 Preliminary Plan for SPring-8 Upgrade (SPring-8-II) Source: Dipole Magnet Layout (distance from source) Pinhole: 6.5m, Scintillator: 32m Pinhole Magnification : x 3.9 Size : 20  m x 20  m Point Spread Function ( Wave Optics Calculation ) Pinhole Resolution (rms) better than 5  m feasible for 40 – 50 keV X-rays Resolution of Present Scintillator Assembly scales to 1.1  m

X-ray Pinhole SPring-8 Summary Live Beam Image Control Room ~ 15 fps Parameters of Beam Profile Continuously Logged to SPring-8 Control DB Indispensable for Beam Tuning and User Operation Resolution (rms) Better than 5  m Feasible for Upgrade Plan of SPring-8 15 September 2015IBIC 2015 Melbourne17 Specifications of the SPring-8 X-ray Pinhole Camera Light SourceBending Magnent (29B2) PinholeDistance from Source (m)11.4 Aperture Size (  m) 20 x 20 ScintillatorDistance from Source (m)34.3 MaterialCdWO 4 CameraNumber of Pixels2448 x 2050 Pixel Size (  m) 3.45 x 3.45 Magnification Factorx 4 ( Pinhole: x 2, Lens: x 2 ) Resolution (rms) (  m) 7.2 ( Pinhole: 6.9, Scintillator & Camera: 2.2 )

15 September 2015 IBIC 2015 Melbourne18 Diffraction patterns depending on a width A of the slit Fraunhofer Diffraction narrow slit (A 2 << R ) Fresnel Diffraction wide slit (A 2 > R ) X-ray Fresnel Diffractometry Monitor (XFD) Principle Double-Lobed Fresnel Diffraction The depth of a median dip correlates with a light source size. optimum slit width for the deepest dip M. Masaki et al., IBIC2014 TUCZB1 (2014). M. Masaki et al., Phys. Rev. ST Accel. Beams 18, (2015).

SPring-8 15 September 2015 IBIC 2015 Melbourne19 ID05 - N u =51 - u =76 mm Monochromator L = 26.8 m R = 65.4 m X-ray camera Slit Setup for Initial Experiments optimum slit width A for the deepest dip - P43 Screen - lenses - CCD camera min. exp. time: 1ms resolution  res : 6.8  m

SPring-8 15 September 2015 IBIC 2015 Melbourne20 Initial Results M. Masaki et al., IBIC2014 TUCZB1 (2014). M. Masaki et al., Phys. Rev. ST Accel. Beams 18, (2015). deeper dip X-ray energy 7.2 keV slit width  Y = 150  m Undulator source size smaller than 10  m successfully resolved

SPring-8 15 September 2015 IBIC 2015 Melbourne21 Recent Progress New X-ray Imaging Setup X-ray Lens: x20 Imaging Resolution Source Point: 2.2 μm <- 6.8  m (previous) Edge of Ta slit exp. time 0.5 ms source size 6.3  m (rms) Camera : pixel size 16x16 μm min. exp. time 0.2 ms Screen: YAG(Ce), 50  mt Ta slit Increased Observing Energy: 16 keV previous Result  y = 7.9 pm.rad (coupling 0.3%)

XFD 15 September 2015 IBIC 2015 Melbourne22 Summary Diagnostic technique for light source rings to measure small beam size at ID (undulator) source point Able to resolve beam size smaller 5  m Requires only slit, monochromator, and imaging device (X-ray camera) Has potential universal availability to ID beamlines of the diffraction limited storage rings (DLSRs)

Conclusions 15 September 2015IBIC 2015 Melbourne23 SPring-8 X-ray Pinhole Camera Resolution (rms) ~ 7  m Live Beam Image Control Room ~ 15 fps Beam Parameters Logged to Control DB by Periodical (1s cycle) Image Analysis Indispensable for Beam Tuning and User Operation of SPring-8 X-ray Fresnel Diffraction (XFD) Monitor Diagnostic Technique for Light Source Rings to Measure Small Beam Size at ID (Undulator) Source Point Requires Only Slit, Monochromator, and Imaging Device (X-ray Camera) Able to Resolve Beam Size smaller 5  m

Acknowledgements 15 September 2015IBIC 2015 Melbourne24 Many thanks to colleagues of SPring-8/SACLA and SES For their help in vacuum, alignment, control and operation etc.

15 September 2015IBIC 2015 Melbourne25 Thank you for your attention !