Acoustic and Implant Driven Vibrations of the Round Window Jonathan H. Spindel 1, Richard L. Goode 2, Alex Huber 3, Geoffrey Ball 4 Department of Integrated.

Slides:



Advertisements
Similar presentations
ANATOMY AND PHYSIOLOGY OF THE EAR
Advertisements

Physiology of Hearing & Equilibrium
What is the Baha ® system? The BAHA system has been a well recognized hearing treatment for conductive and mixed hearing losses since 1977 (Collaborative.
MEMS Rigid Diaphragm Speaker
June 02, 2009 Today ’ s Agenda – Warm up – Video 06/02: Min day 06/03: 06/04: CE Due 06/05: Return Books to Library 06/08: Unit Test Warm- up question:
The Stimulus Input: Sound Waves
M.Sc. in Medical Engineering
Bone Anchored Hearing Aid or Cochlea Implant?
The fish inner ear Swim bladder Weberian ossicle.
THE HUMAN EAR AND SIMPLE TESTS OF HEARING Ear Anatomy  Outer Ear  Auricle, external auditory canal and the tympanic membrane  Middle Ear  An air filled.
The Ear.
The Ear: Hearing and Balance
Hearing.
R3.6.4 Improved Hearing Assessment in Noisy Environments – Parts 1 & 2 Project Leader: Michael Fisher Principal Researcher (Part 1): the late Ben Rudzyn.
A New Bone Conductor with Improved Performance Authors: Eric Burwood (NAL); George Raicevich (NAL); Harvey Dillon (NAL); Carit Laursen (Ortofon) Acknowledgement:
Nick Hamilton EE April 2015 Abstract: When natural hearing is lost, cochlear implants provide an opportunity to restore hearing. These electronic.
What causes hearing loss?
Audiology Training Course ——Marketing Dept. Configuration of the ear ① Pinna ② Ear canal ③ Eardrum ④ Malleus ⑤ Incus ⑥ Eustachian tube ⑦ Stapes ⑧ Semicircular.
Hearing: physiology.
EE Audio Signals and Systems Kevin D. Donohue Electrical and Computer Engineering University of Kentucky.
Esteem Hearing Implant Andrew Dunne. What is Esteem?  A totally implantable hearing system that is implanted under the skin behind the ear and within.
CSD 5400 REHABILITATION PROCEDURES FOR THE HARD OF HEARING Amplification Implantable Hearing Aids.
Humans can hear sounds at frequencies from about 20Hz to 20,000Hz.
BASIC OVERVIEW OF THE EAR AND HEARING LOSS The Ear.
1 Hearing or Audition Module 14. Hearing Our auditory sense.
Cochlear Implants American Sign Language Children & Cochlear Implants Psychological Evaluation of Implant Candidates James H. Johnson, Ph.D., ABPP Department.
Sense of Hearing External Ear Auricle (pinna) - outer ear External Auditory Meatus.
Dr.Khabti Muhanna Mr.Khalid Alaqeel Department of Otolaryngology,
© 2011 The McGraw-Hill Companies, Inc. Instructor name Class Title, Term/Semester, Year Institution Introductory Psychology Concepts Hearing.
The Ear.
Test of Hearing And Pure-tone Audiometry
Hearing and Equilibrium
ANATOMY AND PHYSIOLOGY OF THE EAR
By: Kaeleigh G, Julie B, Sami S, and Kyle S. Parts of the Ear  External (Outer) Ear: The auricle or pinna channels the sound and collects auditory.
transduction , AUDITORY PATHOLOGY , AND AUDITORY PERCEPTION
CHAPTER 6 Outer and Middle Ears.
1 PSYCHOLOGY (8th Edition, in Modules) David Myers PowerPoint Slides Aneeq Ahmad Henderson State University Worth Publishers, © 2007.
Pure Tone Audiometry most commonly used test for evaluating auditory sensitivity delivered primarily through air conduction and bone conduction displayed.
IB Assessment Statements Option I-1, The Ear and Hearing: I.1.1.Describe the basic structure of the human ear. I.1.2.State and explain how sound pressure.
Functions of Ear.
1.3.2 Conduction vs. Sensoneural Deafnness Causes and Corrections.
Noncontact Modal Analysis of a Pipe Organ Reed using Airborne Ultrasound Stimulated Vibrometry May 25, 2004 Acoustical Society of America Meeting Thomas.
Topic Sense of hearing. Topic Sense of hearing.
IB Biology Neurology Unit Option E
Anatomy of the Ear Medical
Anatomy and physiology of the ear. External ear Pinna (auricle) & External auditory meatus Pinna (auricle) & External auditory meatus Function: Localization.
AUDIOLOGY IN ORL DR. BANDAR MOHAMMED AL- QAHTANI, M.D KSMC.
The Lever Ratio. Purpose of ME To transmit sound energy from the air space in the EAC to the fluid in the cochlea This is accomplished by vibration of.
Otoacoustic Emissions
52 The Sense of Hearing Dr. A.R. Jamshidi Fard 2011.
Humans can hear sounds at frequencies from about 20Hz to 20,000Hz.
Physiology Middle ear space stiffness dominated: High- frequency emphasis.
1 Chapter 32 Hearing Loss in Osteogenesis Imperfecta Copyright © 2014 Elsevier Inc. All rights reserved.
Anatomy of the Ear Dr isazadehfar.
Chapter 4 Sensation and Perception. The Ear Audition = hearing Audition = hearing Sounds = mechanical energy typically caused by vibrating objects Sounds.
HEARING- 3. LEARNING OBJECTIVES LEARNING OBJECTIVES Discuss the principles used in performing tests of hearing Discuss the principles used in performing.
Listen and speak clinic is a leading & Speech Therapy and Hearing Aid Center in Pune, Maharashtra. Our staff are multilingual in.
Date of download: 6/29/2016 Copyright © 2016 SPIE. All rights reserved. (a)–(d) shows the access to the cochlea and placement of the optical fiber. The.
COCHLEAR IMPLANTS INSERVICE.  Middle Ear  Hammer  Anvil  Stapes How the ear works  Outer Ear  Inner Ear  Cochlea  Auditory Nerve.
Hearing Module 14.
Hearing tests.
Rehabilitation of Hearing Impaired Individuals
Chapter Menu Lesson 1: Sound Lesson 2: The Ear and Hearing
Unit 1.3 Review MI.
ANATOMY THE EAR Dr. J.K. GERALD, (MD, MSc.).
ANATOMY AND PHYSIOLOGY OF THE EAR
Total implantation of the implex TICA hearing amplifier implant for high-frequency sensorineural hearing loss  Hans Peter Zenner, MD, Hans Leysieffer,
Neurology of The Ear.
ANATOMY AND PHYSIOLOGY OF THE EAR (HEARING)
Sound in the Ear Presentation
Presentation transcript:

Acoustic and Implant Driven Vibrations of the Round Window Jonathan H. Spindel 1, Richard L. Goode 2, Alex Huber 3, Geoffrey Ball 4 Department of Integrated Science and Technology and Department of Communication Sciences and Disorders, James Madison University, Harrisonburg, Virginia, USA 1 Division Of otolaryngology – HNS, Stanford University, Palo Alto California 2 Department of Otorhinolaryngology, University Hospital, Zurich, Switzerland 3 Institute for Applied Physics, University of Innsbruck, Innsbruck, Austria 4 Abstract Research and development over the past two decades has been directed at defining implantable hearing devices that can be used to circumvent issues associated with conventional acoustic amplification. As a result of these efforts a variety of implantable transducers have been developed, tested and applied clinically for the rehabilitation of hearing loss. Within the context of these efforts, debate continues to focus on the site of implantation that can maximize the transfer of vibrational energy to cochlea. The objective of the current study is to investigate the response of a round window implantable hearing device. Potential advantages of a round window-based implant could include increased efficiency for delivering energy to the cochlea, use in treating conductive or mixed losses and an ability to treat patients with middle ear abnormality. A series of bench top studies using human temporal bone were employed to examine round window vibrations in non-implanted bones and bones implanted with floating mass transducers (FMT; Vibrant Med-El, Innsbruck, Austria). Bones were tested using scanning and single point laser Doppler vibrometry (LDV). Scanning measures were obtained for round window vibrations in non-implanted bones while single point LDV measures were taken under three stages of implantation: (a) un-implanted, (b) implanted with a standard incus FMT placement (I-FMT), (c) implanted with an FMT placed on the round window membrane (RW-FMT). Derived measures of induced displacement provided objective measurement of the vibratory input to cochlea and throughout the middle ear. These data indicate that that for a similar electric signal, the RW-FMT provides dB greater linear displacement than the I-FMT. Normalization of the RW-FMT data to account for area differences between oval and round windows, however, indicates that the two attachments will result in similar volume displacements. Continuing studies in patients will provide greater insight into perceived loudness differences between these two methods of cochlear stimulation and help define surgical technique and clinical applicability of the round window approach. Results Measurement of displacement of the stapes footplate in response to the I-FMT is shown in Figure 3 for three stimulation levels. Figure 4 shows the response of the RW-FMT to these same driving signals. Figure 5 shows a direct comparison of average cochlear window displacements measured for an external ear canal (EAC) acoustic stimulation of 100 dB SPL compared to I-FMT and RW-FMT stimuli. RW-FMT responses at the round window are between 8 dB and 17 dB greater than that obtained from the I-FMT at the stapes footplate for the equivalent drive current to the transducer. Single Point Measures Ten fresh frozen temporal bones were examined visually for abnormalities. Each bone was fitted with a probe microphone and acoustic transducer. Each bone was tested using acoustic stimuli, stimuli from an FMT attached to the incus (I-FMT) and stimuli from an FMT in contact with the round window membrane (RW-FMT). A 0.5 mm long, 0.5 mm diameter nylon rod glued to one end of the RW-FMT facilitated placement and contact with the round window membrane. Laser Doppler Vibrometry data provided measurement of vibrational velocity. Velocity data was obtained from the stapes footplate and round window membrane for each test condition and mathematically converted to displacement data. Conclusions The corrected area response shown in Figure 5 implies that the volume displacement of the cochlear fluid is roughly equivalent in both incus and round window FMT driven stimuli. Nevertheless, these findings clearly demonstrate that a round window FMT stimulus is fully capable of driving the ear at or above levels achieved by an ossicular placement. Placement of an FMT, or other vibrational direct drive system, on the round window membrane bypasses the middle ear and delivers vibrational energy almost directly to the cochlear fluid. Avoiding reliance on ossicular placement permits a round window based device to be used to treat a range of middle ear pathologies outside of the inclusion criteria for current middle ear implants including chronic conductive and mixed losses. The potential for higher levels of stimulation to the ear for equivalent drive current may permit use of this approach for high gain applications. Further human clinical investigation to define and refine surgical placement methodologies and clinical objective and subjective responses are necessary to support and confirm the validity of this approach. Use in treating conductive or mixed losses Ability to treat patients with middle ear abnormalities Potential for use as a electro-acoustic device A B Figure 2: Surgical view of the round window without (A) and with (B) the RW-FMT in place. Contact with the RW membrane was accomplish using a 0.5 mm long 0.5 mm diameter nylon rod attached to the FMT. The Vibrant Soundbridge (Vibrant Med-El, Innsbruck, Austria) is an approved clinical implantable hearing device that uses a floating mass transducer to impart vibrational energy to the cochlea through an attachment to the incus. This device has been shown to effective for use in the rehabilitation of sensorineural hearing loss Figure 3: The displacement of the stapes footplate in response to I-FMT stimuli Figure 4: The displacement of the round window in response to RW-FMT stimuli Background The objective of the current study is to investigate the response of this device when applied to the cochlear round window. Advantages of a round window- based implant may include: Scanning LDV Measures Figure 1: Scanning Laser Doppler Vibrometery (SLDV) captures time dependent “images” of round window vibrations under conditions of acoustically induced vibration of the tympanic membrane at 1 kHz (adapted from Huber, Goode and Ball data). Figure 5: Comparison of displacement responses for the I- FMT and RW-FMT. The solid blue line indicates the RW-FMT response corrected for round window area.