Access Control ( Hardware ) June 25, 2010 Created by Castaly / Andy Chen
Access Control Guideline Introduction GV-Reader Series GV-Controller Series Accessories Advance Section Summary FAQ
Guideline for Access Control
AS-H Access Control Introduction
What is access control? –Access Control is any mechanism by which a system grants or revokes the right to access some data, or perform some action. Normally, a user must first login to a system, using some Authentication system. Next, the Access Control mechanism controls what operations the user may or may not make by comparing the UserID to an Access Control database. Introduction
In order to install an Access Control System, you will need the hardware items below. –GV-Controller –GV-Readers / GV-GF Fingerprint Reader Introduction
AS-H01 Access Control System Structure
System Structure for Access Control
AS-H02 GV-Reader Series
What’s Reader? Data Reader A input device A combination of readers or tags
GV-Reader Series Products –GV-Reader 1251 –GV-Reader 1352 V2 –GV-GF1900 –GV-GF1901 –GV-GF1902 –GV-AS100 What’s Reader?
GV-Reader 1251 –Support Wiegand 26 / RS485 Interface –Frequency: 125KHz –Type of Card: E –Card / Tag distance: 4 cm / 3 cm –Temperature: -20 ~ 65 C What’s Reader?
GV-Reader 1352V2 –Support Wiegand 26 / RS485 Interface –Frequency: 13.56MHz –Type of Card: M / F –Card / Tag distance: 5 cm / 4 cm –Temperature: -20 ~ 65 C What’s Reader?
GV-Reader 1251 GV-Reader 1352V2 Communication Wiegand 26 / RS-485 Wiegand 26 / RS-485 Frequency125 KHz13.56 MHz Card / Tag TypeEM / F Distance between Card & Reader 4 / 3 (cm)5 / 4 (cm) Temperature -20 ~ 65°C / -4 ~ 149°F -20 ~ 65°C / -4 ~ 149°F What’s Reader?
GV-GF Enrolled Installation What’s Reader?
GV-GF1900 –Wigand 26 –Frequency: 13.56MHz –Type of GV-Card: F –Temperature: 0 ~ 65 C –Sensing Area: 12 mm x 16 mm –Sensor: Capacitive –No output –Operate Mode: Card + Finger What’s Reader?
GV-GF1901 –Wigand 26 / RS485 –Frequency: 13.56MHz –Type of GV-Card: F –Temperature: 0 ~ 65 C –Sensing Area: 13.2 mm x 18.5 mm –Sensor: Capacitive –Support 1 output ( 240V, 2.5A ) –1900 Fingerprints –Operate Mode: Card + Finger or Finger Only mode What’s Reader?
GV-GF1902 –Wigand 26 / RS485 –Frequency: 13.56MHz –Type of GV-Card: F –Temperature: 0 ~ 65 C –Sensing Area: 17 mm x 20 mm –Sensor: Optical –Support 1 output ( 240V, 2.5A ) –1900 Fingerprints –Operate Mode: Card + Finger or Finger Only mode What’s Reader?
GV-GF1900GV-GF1901GV-GF1902 產品差異產品差異 CommunicationWiegand 26 RS-485 Wiegand 26 RS-485 Frequency13.56 MHz Card / Tag TypeFFF Temperature 0 ~ 65°C / 32 ~ 149°F Finger 感應介面電容式 光學式 Finger 感應面積 12x16(mm) 17x20(mm) I / O 介面 None1 Port (240V/2.5A) Support ModeCard + Finger Mode Finger only Mode Card + Finger Mode Finger only Mode Card + Finger Mode 優點 1. 感應速度快 2. 不受光線干擾 1. 感應速度快 2. 不受光線干擾 1. 指紋偵測面積較大 2. 無手汗症 & 乾手症感 應不良的狀況 缺點 1. 對於手汗症 & 乾手 症感應較差 2. 無 RS-485 介面 3. 無 output 輸出 1. 對於手汗症 & 乾手症感 應較差 1. 光線干擾問題 2. 感應速度較慢
AS-H03 Access Control GV-Controller Series
Access Control GV-AS200 Controller GV-AS400 Controller GV-AS100 Controller GV-ASBox
GV-AS200 Controller GV-AS200
GV-AS200 Controller –Two to four doors controller –Support 4 Wiegand card reader 26~40 bits –Support up to 8 card readers via RS485 –4 Inputs / 3 outputs for each door Inputs: Sensor, Button, Fire, Tamper Outputs: Alarm, Door, Urgent GV-AS200
GV-AS200 Controller –What if there is a disconnection between GV- AS200 controller and GV- ASManager, can GV-AS200 controller still be operated? event buffer access card information –What happens to GV-AS200 controller if connection is back? GV-AS200
GV-AS200 Controller –Not support GV-GFV1901, GV- GFV1902 RS485 interface –GV-GF can ONLY use Wiegand interface –Connect to ASManager via RS485 or TCP/IP RS485 must connect to GV-Hub, GV-Com or GV-Net I/O card v3.1 –Connect Card Reader to AS200 Controller via Wiegand or RS485 GV-AS200
GV-AS400 Controller GV-AS400
GV-AS400 Controller –A four doors controller –Support 8 Wiegand card reader 26~64 bits –Support up to 8 GV-Readers / GV-GF via RS485 –16 Inputs / 16 outputs Max voltage / current difference between 1~8 outputs and 9~16 outputs GV-AS400
GV-AS400 Controller –Connect up to 4 GV-I/O box GV-IOBox 4,8,16 Max 80 inputs / 80 outputs –GV-Reader / GV-GF can connect up to 8 via RS485 connection Only compatible with GeoFinger1901/1902 –Not support Security mode GV-AS400
GV-AS400 Controller –What does it mean when ” low battery” error message shows up in GV-ASKeypad? AS400 remains 10 hours after the battery stops working. GV-AS400
GV-AS100
–One door controller –Support 1 Wiegand interface ( 26~64 bits ) –65536 event buffer –Support 1000 Card information –3 inputs and 2 outputs –No support tag GV-AS100
–Program Mode *227 Access the card manager function *276 Access Security Mode *347 Display system information *738 Access Parameter Setting *737 Restores GV-AS100 to factory default GV-AS100
–Program Mode *837 Test numeral keys to see if they can be displayed properly * Used to cancel the selection or go back to previous page 0 Used to go to the next page # Used to save the data that was modified or programmed in the system and quit. GV-AS100
GV-AS100 With GV-ASBox –Support Doors 1 door to 2 doors –The card information 1000 to –The internet connection RS485 to TCP/IP –I/O 3 IN / 2 Out to 11 IN / 10 Out GV-AS100 GV-ASBox
GV-AS100 With GV-ASBox –Wigand interface 2 in total –RS485 interface 1 in total –GV-GF 4 in total ( ASBox ) GV-AS100 GV-ASBox
GV-AS100 With GV-ASBox –Web Setting Switch When this switch is on, you can modify advance setting of GV-AS100 through the web interface. When the switch is off, advance setting are not accessible. –Briefly went through web interface of GV-AS100 with GVAS- box. ( Very similar to AS400 ) GV-AS100 GV-ASBox
AS-H04 Access Control Accessories
Accessories GV-Keypad GV-Battery
GV-Keypad –Load default in AS200 and ASBox –Upgrade Firmware –Setting Parameter, such as ID, local time –Display System information, such as memory status, IP address, firmware version…etc
GV-Battery –Act as UPS –4 hours max Life span –Can be used in GV-AS200 Controller and other GeoVision device. –Recommended third party battery Yuasa NPH 5-12 GP1245 ( CSB )
GV-Battery –Minimum Requirement for the third-party battery Voltage 12v with suggested 5A Must have Terminal for Power cable connection The size of Battery approximately around the below –Length 3.54” –Width 2.75” –Height 3.93” GV-Battery
AS-H05 Access Control Advance Section – Demo
1)How to connect GV-Reader via RS-485? 2)How to connect GV-Reader via Wiegand? 3)How to setup I/O in GV-AS 200 controller? 4)How to setup I/O in GV-AS400 controller? 5)How to setup I/O in GV-AS100 with ASBox controller? 6)How to add / delete a card in GV- AS100? 6)How to enable / disable a card in GV-AS100? 7)How to restore Factory Default in GV-AS100? Advance Section - Demo
Access Control Summary AS-H06
Review All different Hardware’s features Summary
Review All different Hardware’s features Summary
Access Control FAQ