Stefan Hild for the GEO600 team 14th ILIAS WG1 meeting, October 2007, Hannover Mystery noise in GEO600.

Slides:



Advertisements
Similar presentations
Stefan Hild for the GEO600 team October 2007 LSC-Virgo meeting Hannover Homodyne readout of an interferometer with Signal Recycling.
Advertisements

Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut) HOMODYNE AND HETERODYNE READOUT OF A SIGNAL- RECYCLED GRAVITATIONAL WAVE DETECTOR.
Gravitational Wave Astronomy Dr. Giles Hammond Institute for Gravitational Research SUPA, University of Glasgow Universität Jena, August 2010.
Status of the Virgo Commissioning G.Losurdo – INFN Firenze/Urbino for the Virgo Collaboration.
Stefan Hild Ilias WG1 meeting, Casina, Januar 2005 Title Scattered Light at GEO 600 Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut)
One Arm Cavity M0 L1 L2 TM M0 L1 L2 TRIPLE QUAD 16m R = 20m, T=1% R = ∞, T=1%  Optimally coupled cavity (no mode matched light reflected back)  Finesse.
Takanori Sekiguchi Italy-Japan Workshop (19 April, 2013) Inverted Pendulum Control for KAGRA Seismic Attenuation System 1 D2, Institute for Cosmic Ray.
Cascina, January 24, 2005 Status of GEO600 Joshua Smith for the GEO600 team.
1 ILIAS WG1 meeting, Hannover, Alignment electronics noise budget ● Sources of electronic noise ● C7 electronic noise ● Electronic noise for.
Stefan Hild and A.Freise Advanced Virgo meeting, December 2008 Preliminary Thoughts on the optimal Arm Cavity Finesse of Advanced Virgo.
LIGO-G W Proposed LHO Commissioning Activities in May 02 Fred Raab 29 Apr 02.
1st ET General meeting, Pisa, November 2008 The ET sensitivity curve with ‘conventional‘ techniques Stefan Hild and Andreas Freise University of Birmingham.
Stefan Hild For the GEO-team March 2008, ILIAS WG1, Pisa Projection of small angle scattering.
TeV Particle Astrophysics August 2006 Caltech Australian National University Universitat Hannover/AEI LIGO Scientific Collaboration MIT Corbitt, Goda,
Generation of squeezed states using radiation pressure effects David Ottaway – for Nergis Mavalvala Australia-Italy Workshop October 2005.
Recent Developments toward Sub-Quantum-Noise-Limited Gravitational-wave Interferometers Nergis Mavalvala Aspen January 2005 LIGO-G R.
Towards dual recycling with the aid of time and frequency domain simulations M. Malec for the GEO 600 team Max-Planck-Institut für Gravitationsphysik Albert-Einstein-Institut.
GWADW, May 2012, Hawaii D. Friedrich ICRR, The University of Tokyo K. Agatsuma, S. Sakata, T. Mori, S. Kawamura QRPN Experiment with Suspended 20mg Mirrors.
Stefan Hild 1ILIAS WG1 meeting, Cascina, November 2006 Comparison of tuned and detuned Signal-Recycling Stefan Hild for the GEO-team.
GWADW 2010 in Kyoto, May 19, Development for Observation and Reduction of Radiation Pressure Noise T. Mori, S. Ballmer, K. Agatsuma, S. Sakata,
Stefan Hild 1Ilias WG1 meeting, Sep 2005, Perugia Title GEO 600 Commissioning progress Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut)
Max-Planck-Institut für Gravitationsphysik (Albert-Einstein-Institut) Institut für Atom- und Molekülphysik Detector Characterization of GEO 600 during.
Joshua Smith December 2003 Detector Characterization of Dual-Recycled GEO600 Joshua Smith for the GEO600 team.
Design of Stable Power-Recycling Cavities University of Florida 10/05/2005 Volker Quetschke, Guido Mueller.
Optical Configuration Advanced Virgo Review Andreas Freise for the OSD subsystem.
Interferometer Control Matt Evans …talk mostly taken from…
GEO‘s experience with Signal Recycling Harald Lück Perugia,
1 Noise sources at high frequency in Virgo E. Tournefier (LAPP-CNRS) ILAS WG1 meeting, Hannover December 12 th,2005 Recycled ITF sensitivities Noise sources.
Gabriele Vajente ILIAS WG1 meeting - Perugia Couplings of angular noises into dark fringe Diffused light studies.
WG1, Hannover, Jan Commissioning progress at GEO600 Martin Hewitson for the GEO team.
LISA October 3, 2005 LISA Laser Interferometer Space Antenna Gravitational Physics Program Technical implications Jo van.
Squeezed light and GEO600 Simon Chelkowski LSC Meeting, Hannover.
1 Virgo commissioning: Next steps December 12 st 2005 Hannover, ILIAS-GWA WG1 Matteo Barsuglia, LAL/CNRS.
1 Virgo Commissioning progress ILIAS, Nov 13 th 2006 Matteo Barsuglia on behalf of the Commissioning Team.
Stefan Hild 1GWDAW 10, Brownsville, December 2005 Status of GEO 600 Stefan Hild, AEI Hannover for the GEO-team.
Harald Lückfor the GEO600 Comissioning team 1ILIAS Meeting, Palma, Oct Title GEO 600 Commissioning Status Based on a talk of Stefan Hild for the.
MSC - 18 Oct 071 LOW FREQUENCY SEISMIC NOISE: LOCKING AND SENSITIVITY ISSUE Paolo Ruggi noise meeting.
Nov 3, 2008 Detection System for AdV 1/8 Detection (DET) Subsystem for AdV  Main tasks and requirements for the subsystem  DC readout  Design for: the.
Perugia, Italy Reducing the Noise in GEO600 Joshua Smith for the GEO 600 team.
1 LESSONS FROM VIRGO+ May 17th 2010 E. Calloni for the Virgo collaboration.
M. Mantovani, ILIAS Meeting 7 April 2005 Hannover Linear Alignment System for the VIRGO Interferometer M. Mantovani, A. Freise, J. Marque, G. Vajente.
Dual Recycling in GEO 600 H. Grote, A. Freise, M. Malec for the GEO600 team Institut für Atom- und Molekülphysik University of Hannover Max-Planck-Institut.
1 Virgo Commissioning Status WG1 meeting Potsdam, 21 st July 2006.
Stefan Hild 111th WG1 meeting, Hannover, January 2007 DC-Readout for GEO Stefan Hild for the GEO-team.
Paolo La Penna ILIAS N5-WP1 meeting Commissioning Progress Hannover, July 2004 VIRGO commissioning progress report.
1 DC readout for Virgo+? E. Tournefier WG1 meeting, Hannover January 23 rd,2007 DC vs AC readout: technical noises Output mode cleaner for DC readout.
Joshua Smith July 2004 Identifying limiting noise sources of GEO600 ILIAS WG1 Meeting Joshua Smith for the GEO team.
Joshua Smith August Identifying and eliminating limiting noise sources of GEO600 LSC Meeting, Hanford WA, August `04 Joshua Smith for the GEO team.
1 Frequency Noise in Virgo by Matt Evans. 2 The Actors  Noise Sources  Input Mode Cleaner length noise  Sensing noise on IMC lock  Frequency Servo.
Internal Mode Qs of Monolithically Suspended Test Masses in GEO600 Joshua Smith, Harald Lück, Stefan Goßler, Gianpietro Cagnoli, David Crooks, Sheila Rowan,
NLC - The Next Linear Collider Project Keeping Nanometer Beams Colliding Vibration Stabilization of the Final Doublet Tom Himel SLAC NLC MAC review October.
GEO Status and Prospects Harald Lück ILIAS / ETmeeting Cascina November 2008.
Stefan Hild 1GWADW, Elba, May 2006 Experience with Signal- Recycling in GEO 600 Stefan Hild, AEI Hannover for the GEO-team.
Active Vibration Isolation using a Suspension Point Interferometer Youichi Aso Dept. Physics, University of Tokyo ASPEN Winter Conference on Gravitational.
LIGO-G D Advanced LIGO Systems & Interferometer Sensing & Control (ISC) Peter Fritschel, LIGO MIT PAC 12 Meeting, 27 June 2002.
ET-ILIAS_GWA joint meeting, Nov Henning Rehbein Detuned signal-recycling interferometer unstableresonance worsesensitivity enhancedsensitivity.
Daniel Sigg, Commissioning Meeting, 11/11/16
Reaching the Advanced LIGO Detector Design Sensitivity
Nergis Mavalvala Aspen January 2005
Generation of squeezed states using radiation pressure effects
Design of Stable Power-Recycling Cavities
Homodyne readout of an interferometer with Signal Recycling
Commissioning progress Stefan Hild Ilias WG1 meeting, Sep 2005
Calibration of TAMA300 in Time Domain
Very brief update on the GEO mystery noise investigations
Frequency Noise in Virgo
Advanced Optical Sensing
Talk prepared by Stefan Hild AEI Hannover for the GEO-team
The ET sensitivity curve with ‘conventional‘ techniques
Homodyne detection: understanding the laser noise amplitude transfer function Jérôme Degallaix Ilias meeting – June 2007.
Presentation transcript:

Stefan Hild for the GEO600 team 14th ILIAS WG1 meeting, October 2007, Hannover Mystery noise in GEO600

Stefan HildILIAS WG1 10/2007Slide 2 Intro: What is „mystery noise“? There is a big gap between the uncorrelated sum (pink) of all known noise contributions and the actually measured sensitivity (red).

Stefan HildILIAS WG1 10/2007Slide 3 Intro: What is „mystery noise“? (2) Also the fundamental noise contributions, especially thermal noises are far below the current sensitivity.

Stefan HildILIAS WG1 10/2007Slide 4 Mystery noise => High Priority Limits the GEO sensitivity bet- ween 100 and 800 Hz. Around 200 Hz without mystery noise the sensitivity would be 3 times better. The peak sensitivity (550 Hz) could be improved by about a factor sqrt(2). As long as mystery noise is present, i.e. GEO is not shot noise limited over the major part of the detection band, improvements like increased laser power, DC-readout, squeezing are partly worthless. We need to find the mystery noise! (There is NO other option)

Stefan HildILIAS WG1 10/2007Slide 5 How to tackle the mystery noise ? Mystery noise

Stefan HildILIAS WG1 10/2007Slide 6 How to tackle the mystery noise ? Mystery noise Characteristics of the mystery noise Displacement noise Yes / No ? Any clues from the observation? Displacement-like or not? Stationary? Related to glitches?....

Stefan HildILIAS WG1 10/2007Slide 7 How to tackle the mystery noise ? Mystery noise Fundamental noises Projected noises Characteristics of the mystery noise Displacement noise Yes / No ? Is the gap real? All projections correct? Are all noises projected? Calculations of fundamental noises correct?

Stefan HildILIAS WG1 10/2007Slide 8 How to tackle the mystery noise ? Mystery noise Fundamental noises Projected noises Upconversion Scattered light Characteristics of the mystery noise Exotic noises Displacement noise Yes / No ? Can we rule out the usual candidates: non-linearly coupling noises? How about exotic noises ?....

Stefan HildILIAS WG1 10/2007Slide 9

Stefan HildILIAS WG1 10/2007Slide 10 History of the mystery noise Broadband noise (without significant structure /features) Mystery noise is found to be fairly stable over 15 months (within about 25%). Seems to be independent from environmental conditions. Spectrum (roughly): 1/f^2 below 200 Hz, 1/f above 200 Hz Characteristics of the mystery noise

Stefan HildILIAS WG1 10/2007Slide 11 Mystery noise is independent of the glirchrate Characteristics of the mystery noise Eventhough we observe strong fluctuations in the glitchrate, the mystery noise stays always constant.

Stefan HildILIAS WG1 10/2007Slide 12

Stefan HildILIAS WG1 10/2007Slide 13 Does the mystery noise behave like displacement noise ?? If we could find out life would be much easier... If the mystery noise doesn‘t look like displacement noise: Can rule out all thermal noises Can rule out any noise of the test masses.... If the mystery noise looks like displacement noise: We can rule out many technical noises like oscillator phase noise, oscillator amplitude noise, frequency noise..... Displacement noise Yes / No ?

Stefan HildILIAS WG1 10/2007Slide 14 Checking the mystery noise for different Signal Recycling tunings (1) Mystery noise has different shape and level in 1kHz and 550Hz tuning. => Indication: does not look like displacement noise Displacement noise Yes / No ?

Stefan HildILIAS WG1 10/2007Slide 15 Checking the mystery noise for different Signal Recycling tunings (2) Mystery noise has same shape and level in 350Hz and 550Hz tuning. => Indication: does look like displacement noise Displacement noise Yes / No ?

Stefan HildILIAS WG1 10/2007Slide 16 Displacement noise like: YES / NO ? Mystery noise has same shape and level in 350Hz and 550Hz tuning. => Indication: does look like displacement noise. Mystery noise has different shape and level in 1kHz and 550Hz tuning. => Indication: does not look like displacement noise. Observation 1: Observation 2: Summary: We cannot decide whether the mystery noise is displacment noise or not. (Perhaps it consists of two different components.) => We have to investigate both: displacement AND non-displacement noises. Displacement noise Yes / No ?

Stefan HildILIAS WG1 10/2007Slide 17

Stefan HildILIAS WG1 10/2007Slide 18 What do we have to check in terms of noise projections? Are the noise projections we do correct? Did we miss to project any relevant noise source? Are the transferfunctions used for the projections correct? Projected noises

Stefan HildILIAS WG1 10/2007Slide 19 Which noise projections are relevant for the mystery noise frequency range ? Oscillator phase noise Oscillator amp noise Laser power noise Frequency noise Detection dark noise Two main suspects:  OPN: shape would fit and is not too far from limiting.  PR-noise: Was never really understood (In-loop, high gain) Projected noises

Stefan HildILIAS WG1 10/2007Slide 20 OPN investigations 1: 2f local oscillator Nominal setup: Signal passes optical system, while LO is electrically. Using 2f signal from darkport (devided by 2) as LO => Signal and LO travel the same path. Suppression of OPN Using 2f LO gives same sensitivity Indication: mystery noise is not related to OPN Projected noises

Stefan HildILIAS WG1 10/2007Slide 21 OPN investigations 2: wire instead of MI Idea: Replacing the IFO by a wire should give lower limit of OPN. Replacing: EOM, IFO and photodiode by a ‘good‘ wire Projected noises

Stefan HildILIAS WG1 10/2007Slide 22 OPN investigations 2: wire instead of MI ‚Wire projection‘ gives a noise (yellow trace) close to shot noise. => Mystery noise gap gets smaller. Projected noises

Stefan HildILIAS WG1 10/2007Slide 23 Frequency noise projection: A smoking gun ? The change of the mystery noise from 550Hz to 1kHz tuning looks suspiciously similar to the change of the frequency noise transfer function. Projected noises

Stefan HildILIAS WG1 10/2007Slide 24 Frequency noise projection (2) Main problem of this loop: In-loop measurement with high gain. One important experiment is to set up an out-of-loop photodiode. Projected noises Can rule out any sensing noise of the PR-loop. Left over: Any frequency noise on the light (4 above detection noise) could be the mystery noise.

Stefan HildILIAS WG1 10/2007Slide 25 Noise projections summary improved existing projections added a few missing projections checked for any non-linearities in the transferfunctions (compared swept sine and random noise measurements) the gap got smaller, but is still there.... We believe that OPN is not causing the mystery noise. We believe that the mystery is not related to magnetic fields. We believe that frequency noise is still a good candidate.  Can rule out the electronics (?)  Can rule out the detection  Frequency noise on the light could explain the mystery noise. Projected noises

Stefan HildILIAS WG1 10/2007Slide 26

Stefan HildILIAS WG1 10/2007Slide 27 Checking correctness of shot noise (1) Attenuation experiment: Attenuated the detected light at main photodetector. The sensitivity measured matches the shot noise calculations. Nominal light power Expected sensitivity decrease found (all frequencies) Fundamental noises

Stefan HildILIAS WG1 10/2007Slide 28 Checking correctness of shot noise (2) Shot noise simulations using FINESSE: Fundamental noises

Stefan HildILIAS WG1 10/2007Slide 29 Revisiting the thermal noise calculations The Glasgow group (Reid, Rowan, Hough) revisited all thermal noise calculations: Draft version of a nice and detailed document is available now (includes all equations, references and used parameters). Fundamental noises

Stefan HildILIAS WG1 10/2007Slide 30 Revisiting the thermal noise calculations The Glasgow group (Reid, Rowan, Hough) revisited all thermal noise calculations: Draft version of a nice and detailed document is available now (includes all equations, references and used parameters). Coating TN now distingished in thermorefractive, thermoelastic and brownian. Brownian is the dominant contribution. Didn‘t change. Substrate Brownian noise. Changed slope and level. Now lower, but less steep. BS thermorefractive noise. Now 3.5 times higher. => Dominating TN for frequencies up to 1.5kHz. Fundamental noises

Stefan HildILIAS WG1 10/2007Slide 31 New thermal noise calculations Revisited thermal noises cannot explain the mystery noise. Fundamental noises

Stefan HildILIAS WG1 10/2007Slide 32 Increased thermal noise due to excess damping ? IDEA:  Testmass is close to touching its catcher  There might be conditions where additional damping is caused  Could such damping reduce the Q of the modes and therfore increase the thermal noise ???  (Famous Livingston Earthquake stops???)  We tried to take photographs of the testmasses. Due to the restricted view angles for 4 of the 5 main optics we cannot say how far they are from their catchers. Fundamental noises

Stefan HildILIAS WG1 10/2007Slide 33

Stefan HildILIAS WG1 10/2007Slide 34 Is there any indication for upconversion? Scatter plots: low freq signal vs sensitivity Used low-freq channels: Seismic, MI differential lenght, MI differential auto-alignment Usually no indication of significant upconversion So far only a single data set showed indication for upconversion (0.1 –0.3 Hz) from MID long and MID AA. Upconversion

Stefan HildILIAS WG1 10/2007Slide 35

Stefan HildILIAS WG1 10/2007Slide 36 Scattering Overview External Scattering (outside the vacuum) All interferometer ports Detection bench In-vacuum-Scattering Scattered light from catchers Scattering inside the central cluster Small angle scattering in the folded arms ‚Grating‘-scattering from coating defects Scattered light

Stefan HildILIAS WG1 10/2007Slide 37 External Scattering All interferometer ports We did 2 complete rounds of filter / blocking experiments for all ports outside the vacuum. => No limiting scattering observed Detection bench Ruled out scattering from HPD-path and quadrant path by using an opto-mechanical phase shifter. Scattered light reduction of the o.m. phase shifter Scattered light

Stefan HildILIAS WG1 10/2007Slide 38 Scattered light from the catchers (1) Scattered light Light on the catchers from small angle scattering. Catchers are not seismically isolated Light scattered back into IFO mode can harm sensitivity

Stefan HildILIAS WG1 10/2007Slide 39 Scattered light from the catchers (2) Scattered light Displacement noise from scattering Displacement of catcher Preliminary. Uncertanties= f_cat and X_cat

Stefan HildILIAS WG1 10/2007Slide 40 Scattered light from the catchers (3) Seismic excitation of catchers => no change in h(t) => ruled out scattering from catchers However, probably not far from limiting => preparing baffles Seismic excitation No seismic excitation Scattered light

Stefan HildILIAS WG1 10/2007Slide 41 Scattering inside the central cluster (involving tank walls) Idea: We observe a lot of scattered light inside the central cluster. Some of the stray light from the tank wall might mind find the way to the detection port Ruled out by external shaking of the tank walls: shaking the tank wallsno influence to mystery noise Scattered light

Stefan HildILIAS WG1 10/2007Slide 42 Small angle scattering in the folded arms Scattered light IDEA: Some light hitting the far mirrors is directly scattered back. Can be ruled out as mystery noise:  Far mirrors only move a few microns (rms)  Mirrors are isolated by triple pendulum

Stefan HildILIAS WG1 10/2007Slide 43 ‚Grating‘-scattering from coating defects IDEA: Coating defects can be described as grating. Scattering path: Coating defect => tank wall => Coating defect Beam jitter would cause phase noise analogous to a grating. Inverted photographs of a far mirror (IFO is flashing) Not completely understood so far. However, could be ruled out by shaking experiments. Scattered light

Stefan HildILIAS WG1 10/2007Slide 44 Scattering Overview External Scattering (outside the vacuum) All interferometer ports Detection bench In-vacuum-Scattering Scattered light from catchers Scattering inside the central cluster Small angle scattering in the folded arms ‚Grating‘-scattering from coating defects Scattered light We think we ruled out NEARLY ALL scattered processes we can think of.

Stefan HildILIAS WG1 10/2007Slide 45

Stefan HildILIAS WG1 10/2007Slide 46 Controlled increase of pressure inside the vacuum system (1) Is the mystery noise caused by residual gas pressure? Experiment: Closed all valves to turbo pumps. Pressure at all sensors increa- sed by about a factor 30. Exotic noises

Stefan HildILIAS WG1 10/2007Slide 47 Controlled increase of pressure inside the vacuum system (2) No effect seen in sensitivity. Can ruled out residual pressure as cause of the mystery noise. Exotic noises

Stefan HildILIAS WG1 10/2007Slide 48 Effects from test mass charging? Exotic noises Charges on test masses Measured posi- tive charging of testmasses Discharged by using a UV-lamp (electrons are freed from ESD electrodes) BEFORE AFTER 100V 15V Problem: charges on test masses effect out calibration. However, we believe the charges did not harm the sensitivity.

Stefan HildILIAS WG1 10/2007Slide 49 What else is left over ?? Barkhausen noise Unlikely: Only MSR and MPR have magnets directly at the mirror Maybe the mystery noise is a new type of noise (GEO specific): ESDs ? Signal-Recycling ? Monolithic suspensions ? Folded arms ? High power in BS substrate ? High PR gain ? Exotic noises

Stefan HildILIAS WG1 10/2007Slide 50 Does the mystery noise depend on the optical power ?? Using only 66% of nominal optical power reduces the ‚gap‘. Above 300 Hz the mystery noise is smaller with low power, while below 300 Hz it stays constant. Another indication that we are looking for more than one mystery noises. Exotic noises

Stefan HildILIAS WG1 10/2007Slide 51 Additional Slides

Stefan HildILIAS WG1 10/2007Slide 52 The Vacuum system of GEO600