Part 1: Basic Principle of Measurements

Slides:



Advertisements
Similar presentations
Industrial Instrumentation
Advertisements

It is very difficult to measure the small change in volume of the mercury. If the mercury had the shape of a sphere, the change in diameter would be very.
Instructor: Lichuan Gui
Dynamic Performance Class 4.
Lecture Notes Part 4 ET 483b Sequential Control and Data Acquisition
Control System Instrumentation
Learning Objectives Static and Dynamic Characteristics of Signals
1 Chapter 2: Measurement Errors  Gross Errors or Human Errors –Resulting from carelessness, e.g. misreading, incorrectly recording.
Characteristics of Instruments P M V Subbarao Professor Mechanical Engineering Department A Step Towards Design of Instruments….
STATIC CHARACTERISTICS OF MEASURING INSTRUNMENTS
1 Fourth Lecture Static Characteristics of Measurement Systems (continued) Instrumentation and Product Testing.
Part 1: Basic Principle of Measurements
1 Seventh Lecture Error Analysis Instrumentation and Product Testing.
Data Converter Performance Metric
Chapter One Characteristics of Instrumentation بسم الله الرحمن الرحيم.
Performance Characteristics of Sensors and Actuators
Classification of Instruments :
Types of Measurement Direct Measurement : In direct measurement, the meaning of the measurement and the purpose of the processing operation are identical.
Topic 1 different attributes that characterize sensors ETEC 6405.
1 Measurement and Instrumentation. 2 CODE: MET General Introduction to Measurement and Instrumentation Kamoleka, Masoud MSc(Renewable Energy), UDSM.
1 Input transduction Input transduction 6. MEASUREMENT SYSTEM CHARACTERISTICS General structure of a measurement system 6. MEASUREMENT SYSTEM CHARACTERISTICS.
Instrumentation and Measurements
Metrology and Gauging Instructed by: Dr. Sajid Zaidi
Sensitivity System sensitivity is defined as the available input signal level Si for a given (SNR)O Si is called the minimum detectable signal An expression.
Transducers/Sensors Transducer/sensor converts a non- electrical quantity, measurand, into a related electrical output signal Ideally there is a linear.
Understanding ADC Specifications September Definition of Terms 000 Analogue Input Voltage Digital Output Code FS1/2.
INTRODUCTION TO MEASUREMENT
1 Passive components and circuits - CCP Lecture 4.
Performance characteristics for measurement and instrumentation system
LECTURER PROF.Dr. DEMIR BAYKA AUTOMOTIVE ENGINEERING LABORATORY I.
Instrumentation and Measurements Class 3 Instrument Performance Characteristics.
3. Sensor characteristics Static sensor characteristics
Lecture 3 Mechanical Measurement and Instrumentation MECN 4600 Department of Mechanical Engineering Inter American University of Puerto Rico Bayamon Campus.
Capacitive transducer. We know that : C=kЄ° (A/d) Where : K=dielectric constant Є° =8.854 *10^-12 D=distance between the plates A=the area over lapping.
Lecture I Sensors.
Definition Metrology is the name given to the science of pure measurement. Engineering Metrology is restricted to measurements of length & angle Measurement.
Module 1: Measurements & Error Analysis Measurement usually takes one of the following forms especially in industries: Physical dimension of an object.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Measurements Measurements and errors : - Here, the goal is to have some understanding of the operation and behavior of electrical test instruments. Also,
Definition of a sensor Def. 1. (Oxford dictionary)
Basic Concepts: Definitions Readability (R): indicates the closeness with which the scale of the instrument may be read.Readability (R): indicates the.
Lecture 7: Measurement Systems.
Instrument Characteristics  Scientific Instrument: l A device for making a measurement.  Measurement: l An action intended to assign a number as the.
This represents the most probable value of the measured variable. The more readings you take, the more accurate result you will get.
Department of Optical Engineering Zhejiang University Department of Optical Engineering Zhejiang University Advanced Sensor Technology Lecture 2 Jun. QIAN.
G UJARAT P OWER E NGINEERING A ND R ESEARCH I NSTITUTE, M EWAD PHILOSOPHY OF MEASUREMENT Created By: 1. Urvish Mehta ( ) 2. Viraj Shah ( )
2. Sensor characteristics Static sensor characteristics
MECH 373 Instrumentation and Measurements
MECH 373 Instrumentation and Measurement
ELECTRONIC INSTRUMENTATIONS
MECH 373 Instrumentation and Measurement
MMM Lecture 2.
Performance characteristics
(7) Measurement Systems.
ELECTRICAL MEASURMENT AND INSTRUMENTS
Electronic Instrumentation Lectrurer Touseef Yaqoob
Lesson 2: Performance of Control Systems
Characteristics of measurement systems
Electronic Control Systems Week 4 – Signaling and Calibration
Chapter 2: Performance Characteristics of Instruments
BASICS OF MEASUREMENT AND INSTRUMENTATION
Control System Instrumentation
Mechanical Measurements and Metrology
Instrumentation & Measurement (ME342)
Lesson 10: Sensor and Transducer Electrical Characteristics
Measurements Measurements and errors :
Measurement errors and uncertainties
Measurements & Error Analysis
Measurements and Instrumentation
Basic Steps in Development of Instruments
Presentation transcript:

Part 1: Basic Principle of Measurements 4/23/2017 www.notesht.com

Basic components in a measurement system Basic components in a measurement system are shown below: Amplification and Conditioning It is also important to mention that a power supply is an important element for the entire system. 4/23/2017 www.notesht.com

INSTRUMENTATION CHARACTERISTICS Shows the performance of instruments to be used. Divided into two categories: static and dynamic characteristics. Static characteristics refer to the comparison between steady output and ideal output when the input is constant. Dynamic characteristics refer to the comparison between instrument output and ideal output when the input changes. 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS ACCURACY Accuracy is the ability of an instrument to show the exact reading. Always related to the extent of the wrong reading/non accuracy. Normally shown in percentage of error which of the full scale reading percentage. 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS 2. PRECISION An equipment which is precise is not necessarily accurate. Defined as the capability of an instrument to show the same reading when used each time (reproducibility of the instrument). 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS Example : X : result Centre circle : true value XXX Low accuracy, high precision XXX XXXX X X X High accuracy, high precision x x Low accuracy, low precision 4/23/2017 www.notesht.com

Accuracy vs Precision High Precision, but low accuracy. There is a systematic error. 4/23/2017 www.notesht.com

Accuracy vs Precision (Cont) High accuracy means that the mean is close to the true value, while high precision means that the standard deviation σ is small. 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS 3. TOLERANCE Closely related to accuracy of an equipment where the accuracy of an equipment is sometimes referred to in the form of tolerance limit. Defined as the maximum error expected in an instrument. Explains the maximum deviation of an output component at a certain value. 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS 4. RANGE OF SPAN It defines the maximum and minimum values of the inputs or the outputs for which the instrument is recommended to use. For example, for a temperature measuring instrument the input range may be 100-500 oC and the output range may be 4-20 mA. 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS 5. BIAS Constant error which occurs during the measurement of an instrument. This error is usually rectified through calibration. Example : A weighing scale always gives a bias reading. This equipment always gives a reading of 1 kg even without any load applied. Therefore, if A with a weight of 70 kg weighs himself, the given reading would be 71 kg. This would indicate that there is a constant bias of 1 kg to be corrected. 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS 6. LINEARITY Maximum deviation from linear relation between input and output. The output of an instrument has to be linearly proportionate to the measured quantity. Normally shown in the form of full scale percentage (% fs). The graph shows the output reading of an instrument when a few input readings are entered. Linearity = maximum deviation from the reading of x and the straight line. 4/23/2017 www.notesht.com

Linearity Output Readings Measured Quantity 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS 7. SENSIVITY Defined as the ratio of change in output towards the change in input at a steady state condition. Sensitivity (K) = Δθο Δθi Δθο : change in output; Δθi : change in input Example 1: The resistance value of a Platinum Resistance Thermometer changes when the temperature increases. Therefore, the unit of sensitivity for this equipment is Ohm/°C. 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS 8. DEAD SPACE / DEAD BAND Output Reading - + Measured Variables Dead Space Defined as the range of input reading when there is no change in output (unresponsive system). 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS 9. RESOLUTION The smallest change in input reading that can be traced accurately. Given in the form ‘% of full scale (% fs)’. Available in digital instrumentation. 4/23/2017 www.notesht.com

STATIC CHARACTERISTICS 10. THRESHOLD When the reading of an input is increased from zero, the input reading will reach a certain value before change occurs in the output. The minimum limit of the input reading is ‘threshold’. 4/23/2017 www.notesht.com

DYNAMIC CHARACTERISTICS Explains the behaviour system of instruments system when the input signal is changed. Depends on a few standard input signals such as ‘step input’, ‘ramp input’ dan ‘sine-wave input’. 4/23/2017 www.notesht.com

DYNAMIC CHARACTERISTICS Step Input Sudden change in input signal from steady state. The output signal for this kind of input is known as ‘transient response’. Input Time 4/23/2017 www.notesht.com

DYNAMIC CHARACTERISTICS Ramp Input The signal changes linearly. The output signal for ramp input is ‘ramp response’. Input Time 4/23/2017 www.notesht.com

DYNAMIC CHARACTERISTICS Sine-wave Input The signal is harmonic. The output signal is ‘frequency response’. Input Time 4/23/2017 www.notesht.com

Response time One would like to have a measurement system with fast response. In other words, the effect of the measurement system on the measurement should be as small as possible. 4/23/2017 www.notesht.com

EXAMPLE OF DYNAMIC CHARACTERISTICS Response from a 2nd order instrument: Output 100% 90% 10% tr Time 4/23/2017 www.notesht.com

EXAMPLE OF DYNAMIC CHARACTERISTICS Response from a 2nd order instrument: Rise Time ( tr ) Time taken for the output to rise from 10% to 90 % of the steady state value. Settling time (ts) Time taken for output to reach a steady state value. 4/23/2017 www.notesht.com

Sensor Performance Characteristics Transfer Function: The functional relationship between physical input signal and electrical output signal. Usually, this relationship is represented as a graph showing the relationship between the input and output signal, and the details of this relationship may constitute a complete description of the sensor characteristics. For expensive sensors which are individually calibrated, this might take the form of the certified calibration curve. Sensitivity: The sensitivity is defined in terms of the relationship between input physical signal and output electrical signal. The sensitivity is generally the ratio between a small change in electrical signal to a small change in physical signal. As such, it may be expressed as the derivative of the transfer function with respect to physical signal. Typical units : Volts/Kelvin. A Thermometer would have "high sensitivity" if a small temperature change resulted in a large voltage change. Span or Dynamic Range: The range of input physical signals which may be converted to electrical signals by the sensor. Signals outside of this range are expected to cause unacceptably large inaccuracy. This span or dynamic range is usually specified by the sensor supplier as the range over which other performance characteristics described in the data sheets are expected to apply. 4/23/2017 www.notesht.com

Sensor Performance Characteristics Accuracy: Generally defined as the largest expected error between actual and ideal output signals. Typical Units : Kelvin. Sometimes this is quoted as a fraction of the full scale output. For example, a thermometer might be guaranteed accurate to within 5% of FSO (Full Scale Output) Hysteresis: Some sensors do not return to the same output value when the input stimulus is cycled up or down. The width of the expected error in terms of the measured quantity is defined as the hysteresis. Typical units : Kelvin or % of FSO Nonlinearity (often called Linearity): The maximum deviation from a linear transfer function over the specified dynamic range. There are several measures of this error. The most common compares the actual transfer function with the `best straight line', which lies midway between the two parallel lines which encompasses the entire transfer function over the specified dynamic range of the device. This choice of comparison method is popular because it makes most sensors look the best. 4/23/2017 www.notesht.com

Sensor Performance Characteristics Noise: All sensors produce some output noise in addition to the output signal. The noise of the sensor limits the performance of the system based on the sensor. Noise is generally distributed across the frequency spectrum. Many common noise sources produce a white noise distribution, which is to say that the spectral noise density is the same at all frequencies. Since there is an inverse relationship between the bandwidth and measurement time, it can be said that the noise decreases with the square root of the measurement time. Resolution: The resolution of a sensor is defined as the minimum detectable signal fluctuation. Since fluctuations are temporal phenomena, there is some relationship between the timescale for the fluctuation and the minimum detectable amplitude. Therefore, the definition of resolution must include some information about the nature of the measurement being carried out. Bandwidth: All sensors have finite response times to an instantaneous change in physical signal. In addition, many sensors have decay times, which would represent the time after a step change in physical signal for the sensor output to decay to its original value. The reciprocal of these times correspond to the upper and lower cutoff frequencies, respectively. The bandwidth of a sensor is the frequency range between these two frequencies. 4/23/2017 www.notesht.com