1 Workshop on X-ray Mission Architectural Concepts Linthicum, MD December 14-15, 2011 Enabling Technologies for the High-Resolution Imaging Spectrometer.

Slides:



Advertisements
Similar presentations
CHAPTER 4 HELIX TRAVELING-WAVE TUBES(TWT’S)
Advertisements

Present status of the laser system for KAGRA Univ. of Tokyo Mio Lab. Photon Science Center SUZUKI, Ken-ichiro.
Recent progress with TES microcalorimeters and signal multiplexing J. Ullom NIST NASA GSFC SRON J. Beall R. Doriese W. Duncan L. Ferreira G. Hilton R.
Readout ASIC Development VERITAS II Garching, 28 January 2014 Matteo Porro.
Superconducting Quantum Interference Device SQUID C. P. Sun Department of Physics National Sun Yat Sen University.
LTD12, Paris Microstructured magnetic calorimeter with meander shaped pickup coil A. Burck S. Kempf, S. Schäfer, H. Rotzinger, M. Rodrigues, T. Wolf, A.
X-ray Astronomy Lee Yacobi Selected Topics in Astrophysics July 9.
Hybrid MKIDs with ground-side deposition - A novel method for microwave detection with a resonator separated from antenna H. Watanabe, M. Hazumi a, H.
Astro-E2 and Japanese future space programs for high energy astrophysics Astro-E2 NeXT XEUS Small satellite programs Tadayasu Dotani (ISAS)
1 Chapter 6 Low-Noise Design Methodology. 2 Low-noise design from the system designer’s viewpoint is concerned with the following problem: Given a sensor.
1 Chapter 5 Sensors and Detectors A detector is typically the first stage of a communication system. Noise in this stage may have significant effects on.
CCD-style imaging for the JCMT. SCUBA-2 technology  the ability to construct large format detector arrays  signal readouts that can be multiplexed To.
Ultimate Cold-Electron Bolometer with Strong Electrothermal Feedback Leonid Kuzmin Chalmers University of Technology Bolometer Group Björkliden
Microwave Spectroscopy of the radio- frequency Cooper Pair Transistor A. J. Ferguson, N. A. Court & R. G. Clark Centre for Quantum Computer Technology,
Third International Conference on Frontier Science Villa Mondragone – Monteporzio Catone Physics and Astrophysics in Space June 14, 2004 Mercedes Paniccia.
1 Detectors RIT Course Number Lecture Single Element Detectors.
X-Ray Spectroscopy. 1 eV 100 eV 10 eV Energy (keV) The need for high resolution X-ray spectroscopy Astrophysical Plasmas: Simulation of the emission from.
June X-Ray Spectroscopy with Microcalorimeters1 X-Ray Spectrometry with Microcalorimeters.
Chapter 6 FM Circuits.
Fiber Optic Receiver A fiber optic receiver is an electro-optic device that accepts optical signals from an optical fiber and converts them into electrical.
Orit Skorka and Dileepan Joseph University of Alberta, Canada Reducing Crosstalk in Vertically- Integrated CMOS Image Sensors.
Superconducting Qubits Kyle Garton Physics C191 Fall 2009.
Electron Spin Resonance Spectroscopy
TRANSISTOR Transistor is a semiconductor device made of a solid piece of semiconductor material,with atleast three terminals for connection to an external.
Cardiff University Astronomy Instrumentation Group IRAM Camera meeting October 13-14, Cardiff University Astronomical Instrumentation Peter Ade.
Passive components and circuits
Low Temperature X-ray Detectors Caroline K. Stahle NASA / Goddard Space Flight Center.
High-resolution X-ray spectroscopy with microcalorimeters L. Piro Some key scientific drivers: –GRB engine and progenitors: X-ray lines and absorption.
LEKIDs effort in Italy Martino Calvo B-Pol workshop, IAP Paris, July.
Why silicon detectors? Main characteristics of silicon detectors: Small band gap (E g = 1.12 V)  good resolution in the deposited energy  3.6 eV of deposited.
Development of Low Temperature Detector S.C. Kim (SNU, DMRC)
Rome, January 17th,2006 Flavio Gatti WHIM and Mission Opportunities TES microcalorimeters in the European context Flavio Gatti University and INFN, Genoa.
ConX – XEUS meeting Panu Helistö, Mikko Kiviranta Utrecht,
EE1008- ELECTRICAL AND ELECTRONICS MEASUREMENTS AND INSTRUMENTATION
Avalanche Transit Time Devices
MANU2: status report Maria Ribeiro Gomes* for the Genoa Group IAP, 14-Nov-05 * pos-doc under TRN HPRN-CT
1 Approved for public release, distribution unlimited Workshop on X­ Ray Mission Architectural C oncepts December 14-15, 2011 Approved for public release,
EE1008- ELECTRICAL AND ELECTRONICS MEASUREMENTS AND INSTRUMENTATION UNIT -1 Measurement of R, L, C 10/21/2015www.noteshit.com1.
Recent Progress in Silicon Microcalorimeters and Their Prospects for NeXT (and other missions) Caroline A. Kilbourne NASA Goddard Space Flight Center.
Large Area Microcalorimeters of the Diffuse X-ray Background Sarah Bank Towson University August 5, 2004.
MVE MURI 99 Kick-off Meeting R. Barker, Technical Monitor Started 1 May 99 October 1999 Project Introduction and Motivation Millimeter-wave switches may.
Astronomy detectors Andy Vick (UKATC). Introduction and contents General overview of astronomy detectors, mainly visible, IR, sub-mm –Radio is a different,
WFIRST 10  m Pixel Pitch Detector Considerations March 10, /10/
Instrumental Development in Japan for Future Missions 1.Si strip detectors(GLAST) 2.Supermirror technology 3.New hard-X/  detectors 4.TES calorimeters.
Metallic magnetic calorimeters (MMC) for high resolution x-ray spectroscopy Loredana GASTALDO, Markus LINCK, Sönke SCHÄFER, Hannes ROTZINGER, Andreas BURCK,
Status of Development of Metallic Magnetic Calorimeters A.Fleischmann, T. Daniyarov H. Rotzinger, M. Linck, C. Enss Kirchhoff-Institut für Physik Universität.
SiD R&D tasks for the LOI - Subsystem R&D tasks - Summary of SiD R&D - Prioritization of R&D tasks -> Document for DoE/NSF ~Feb 2009 (Mainly based on Marty’s.
Cryogenic Detectors and Test Infrastructure at the University of Leicester G.W. Fraser Space Research Centre, Michael Atiyah Building, Department of Physics.
XEUS Cryogenic Instrument October 2004 Cryogenic X-ray sensor development in US, Europe and Japan Micro-calorimeters Doped - thermistors Astro-E2.
Metallic Magnetic Calorimeters for High-Resolution X-ray Spectroscopy D. Hengstler, C. Pies, S. Schäfer, S. Kempf, M. Krantz, L. Gamer, J. Geist, A. Pabinger,
Demonstration of a Far-IR Detector for Space Imaging Principal Investigators: C. Darren Dowell (326), Jonas Zmuidzinas (Caltech) Co-Investigators: Peter.
MPI Semiconductor Laboratory, The XEUS Instrument Working Group, PNSensor The X-ray Evolving-Universe Spectroscopy (XEUS) mission is under study by the.
MARE Microcalorimeter Arrays for a Rhenium Experiment A DETECTOR OVERVIEW Andrea Giuliani, University of Insubria, Como, and INFN Milano on behalf of the.
1 MARE Direct determination of neutrino mass with Low Temperature Microcalorimeters Flavio Gatti University and INFN of Genoa CSNII, 29 Sept 2009.
STATUS OF R&D AT UCSB Paul Szypryt Mazin Lab August 26, 2013.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
Clear Performance and Demonstration of a novel Clear Concept for DEPFET Active Pixel Sensors Stefan Rummel Max-Planck-Institut für Physik – Halbleiterlabor.
EKT 451 CHAPTER 6 Sensor & Transducers.
Yong-Hamb Kim Development of cryogenic CaMoO 4 detector 2nd International Workshop on double beta decay search Oct. 7~ Oct. 8, 2010.
Low Temperature Detector Design for the particle search Kim Seung Cheon (DMRC,SNU)
Current status of R&D on MMC and TES and a full size crystal test setup Sang-jun Lee Seoul National University.
Institute for Photonics and Nanotechnologies
Microwave SQUID multiplexer for the readout of large MMC arrays
Basic Circuit Components
Pulse Processing and Shaping
Large bolometer arrays on radio telescopes.
PIN DIODE.
Some thoughts on readout
POWER SEMICONDUCTOR DEVICES OVERVIEW
Why silicon detectors? Main characteristics of silicon detectors:
Presentation transcript:

1 Workshop on X-ray Mission Architectural Concepts Linthicum, MD December 14-15, 2011 Enabling Technologies for the High-Resolution Imaging Spectrometer of the Next NASA X-ray Astronomy Mission – Options, Status, and Roadmap Caroline Kilbourne NASA Goddard Space Flight Center S. Bandler 1, J. Chervenak 1, W.B. Doriese 1, G. Hilton 2, K. Irwin 2, R. Kelley 1, F.S. Porter 1, C. Reintsema 2, J. Ullom 2 1 Goddard 2 NIST

2  Why high-resolution detectors are low-temperature detectors  Leading technologies  Multiplexed read-out  Technology roadmap Outline

3 High-resolution imaging spectroscopy requires low-temperature detectors Non-equilibrium:  Energy creates quantized excitations (E >> kT)  Number of excitations proportional to E  Fano-limited resolution  Low temperature required to avoid thermally generated excitations Equilibrium:  Sensor is in thermal equilibrium –  T proportional to  E/C  Resolution from accuracy of measuring  T on background of T fluctuations  Low-temperature needed to minimize thermal fluctuations and lower C ** For eV-scale resolution, T < ~ 0.1 K is required. **

4 Highest resolution demonstrated with equilibrium devices (microcalorimeters)  Thermometers can be based on: resistance, capacitance, inductance, paramagnetism, magnetic penetration, electron tunneling …  The leading technologies: –Resistance (semiconductor thermistors and resistive transition of superconductors) –Magnetically coupled calorimeters

5 Silicon thermistor-based calorimeter array for Astro-H  Base temperature of 50 mK  36 pixels – silicon thermistors on 0.83 mm pitch with HgTe absorbers  Resolution at 6 keV ranges from 3.6 – 4.6 eV across EM and FM arrays  Lack of large-scale read-out technology limits arrays to a few hundred pixels –Further investment warranted if technique for multiplexing is demonstrated SXS FM candidate array

6 Transition-edge sensors (TES) – IXO/XMS baseline  Temperature and current dependence of the transition from the zero- resistance to normal-resistance state used for thermometry  XMS reference design based on GSFC TES design –Membrane-isolated Mo/Au TES with T c ~ 90 mK, (base temperature at 50 mK) –Electroplated Bi/Au absorbers, 0.25 – 0.30 mm pitch –1.8 eV resolution demonstrated, 2 – 3 eV routine in this design –Multiplexed SQUID read-out close to requirements for few-thousand pixel array –32x32 arrays with microstrip leads successfully fabricated

7 TES – smaller pixels  Small pixels suited to shorter focal lengths and/or higher spatial resolution  In small TES devices, T c depends sensitively on current – extends linear operating range of pixels  Don’t need membrane isolation; small size limits coupling to solid substrate –Heat sinking of solid substrate minimizes thermal crosstalk  Through choice of T c, can be optimized for speed or resolution mm pixel with 0.03 ms time constant

8 TES – sub-eV resolution  TES on mm pitch  Au absorber: mm x mm x mm  Design uses relatively slow pixels (1.6 ms decay times)

9 Inductive thermometers – using temperature dependence of paramagnetism or magnetic penetration of a superconductor  Arrays of Nb meanders with layer of magnetic material (Au:Er) or a low- Tc superconductor (Mo/Au) –change of magnetization measured as change of inductance  The Heidelberg group has achieved just better than 2.0 eV resolution at 6 keV with a Au:Er metallic magnetic calorimeter (MMC)  GSFC group recently obtained 2.3 eV resolution with Mo/Au magnetic penetration thermometer (MPT).

10 Magnetically coupled calorimeters (MCC) compared with TES  MCCs are intrinsically dissipationless –very large-format focal-plane arrays  MCC sensor material is electrically isolated –can be directly connected to metallic heat sink – simplifying reduction of thermal crosstalk  Dissipation in TES calorimeters allows electrothermal feedback –stabilizes operating temperature, relaxing temperature stability required at heat sink  TES read-out allows easy signal filtering, simplifying multiplexing. Each has advantages and disadvantages – parallel investment in both TES and MCCs is recommended

11 Using the non-equilibrium signal in equilibrium devices for position discrimination  Multiple absorbers connected thermally to the same thermometer via different thermal links  Demonstrated for TESs and MMCs eV resolution obtained in 9-pixel TES device with mm pixels  Ideal “hydra” obtains somewhat worse resolution than for one big pixel of the same area due to thermal fluctuations between the absorbers

12 Superconducting Non-equilibrium Detectors  X-ray energy breaks Cooper pairs in a superconductor into quasiparticles. Microwave kinetic inductance detectors (MKIDs) are one technique for measuring the number of quasiparticles produced. –quasiparticles are trapped near sensitive element of a microwave resonator. –measure change in kinetic inductance from change in quasiparticle density  Intrinsic advantages: –speed of signal and high multiplexibility of MKIDs  Intrinsic disadvantages: –good energy resolution not demonstrated –competitive resolution at 6 keV not even theoretically possible with Nb  Not best match to IXO science; could be important for other experiments not requiring highest-resolution spectroscopy

13 Multiplexed read out: switched SQUID multiplexing  XMS reference design included time-division multiplexing (TDM) –Individual TES pixels are coupled (via each pixel’s SQUID) to a single amplifier –Multiplexed by sequential switching between SQUIDs –Used in TRL-4 TES read-out demo in 2008 (2.6 – 3.1 eV across 16 mux’d TESs)  Code Division Multiplexing (CDM) will soon reach TDM TRL level –All pixels ON all the time, polarity of coupling is switched –CDM has a sqrt(N) noise advantage over TDM, where N is the multiplexing scale –IXO/XMS noise budget extremely tight – CDM could provide important margin  CDM demonstrated: < 3 eV on 16 switched pixels using flux-matrixed CDM TDM CDM

14 Frequency domain multiplexing (FDM)  TES bias modulation –Different TES pixels AC-biased at different frequencies read out by single SQUID –X-ray pulses seen in amplitude modulation –Like CDM, pixels on all the time, imparting a sqrt(N) advantage over TDM –However, in identical pixels tested with AC and DC bias, significantly better resolution was obtained in the DC bias case, which may be fundamental  Microwave multiplexing –Pixel electronics form high-Q microwave resonant circuits (GHz scale), hundreds of which can be combined on a single coax –For MKIDs the sensor itself is part of the resonator –For TESs, MMCs, and MPTs, an unshunted rf SQUID is incorporated into the read out of each pixel, which is in turn coupled to a resonant circuit –Likely to be needed for pixel scales > ~10,000

15 Technology roadmap  SCOPE –Impossible to define a generic technology roadmap for new mission concepts that meet all or some of the original IXO scientific objectives. –Thus, we have kept close to the original XMS baseline for the detector system for the projected roadmap and cost, with an allowance for alternate technologies to merge into the flow. –Development of many of the alternate technologies is already funded for other applications. –The IXO/XMS roadmap is representative of the roadmaps needed for other LTD-based instruments  IXO/XMS TRL 4 reached in 2008 –The “2x8 demo” of multiplexed read-out of part of a TES array achieved the most fundamental goal of a demonstration of TRL 4 – basic technological components were integrated to establish that they will work together.

16 IXO/XMS roadmap – representative development path for a multi-component focal plane (from mid-TRL technologies)  TRL 5 demo of core array –Demonstrate multiplexed (3 columns x 32 rows) read-out of 96 different flight- like pixels … work towards an Athena-scaled version (3x16) in progress now (Goddard/NIST)  TRL 5 demo of outer array –Demonstrate multiplexed (2 columns x 32 rows) read-out of 8x8 array of four- absorber devices…  TRL 5 of particle veto –Demonstrate particle veto prototype on scale appropriate for full XMS array…  integrated detector system TRL 5 –Demonstrate core array, outer array, and anti-coincidence detector together, though not in a flight-like arrangement.

17 IXO/XMS roadmap (3)  integrated detector system TRL 6 –Multiplexed (6x32) read-out of portion of full composite focal plane array 128 different single-TES pixels in a 40x40 core array 64 multi-absorber TES ( mm pixels) of a full-sized outer array Particle-veto integrated into the test set-up. Electrical and thermal interconnects and staging approach flight-worthy design

18 Going forward  Cost to TRL 6 –Depends on mission goals and whether funding ramps up quickly or slowly. –Range ~$10M to $20M first is for focused development of only the core-array technologies over ~4 years latter is for slower development of something like full IXO/XMS detector system »some investment in technology variations, such as CDM based on historical cost of advancing these technologies through APRA, Con-X development, and other sources.  Forecast –CDM could replace TDM in the roadmap in the next two years –In 2-4 years, new TES designs will enable improvements in intrinsic TES resolution –By 2017, magnetically coupled calorimeters and microwave multiplexing will be on solid footing, advancing towards mega-pixel arrays.

19 Development trajectory