Precision Analysis of Electron Energy Deposition in Detectors Simulated by Geant4 M. Bati č, S. Granato, G. Hoff, M.G. Pia, G. Weidenspointner 2012 NSS-MIC.

Slides:



Advertisements
Similar presentations
Maria Grazia Pia, INFN Genova Test & Analysis Project Maria Grazia Pia, INFN Genova on behalf of the T&A team
Advertisements

1 COMPARISON BETWEEN PLATO ISODOSE DISTRIBUTION OF A 192 IR SOURCE AND THOSE SIMULATED WITH GEANT4 TOOLKIT F. Foppiano 1, S. Agostinelli 1, S. Garelli.
Precision validation of Geant4 electromagnetic physics Katsuya Amako, Susanna Guatelli, Vladimir Ivanchenko, Michel Maire, Barbara Mascialino, Koichi Murakami,
Stefan Roesler SC-RP/CERN on behalf of the CERN-SLAC RP Collaboration
Advanced GAmma Tracking Array
Maria Grazia Pia, INFN Genova Atomic Relaxation Models A. Mantero, B. Mascialino, Maria Grazia Pia INFN Genova, Italy P. Nieminen ESA/ESTEC
Parameterized Shower Simulation in Lelaps: a Comparison with Geant4 Daniel Birt, Amy Nicholson.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
Geant4-Genova Group Validation of Susanna Guatelli, Alfonso Mantero, Barbara Mascialino, Maria Grazia Pia, Valentina Zampichelli INFN Genova, Italy IEEE.
Max-Planck-Institut für extraterrestrische Physik and Halbleiterlabor, Germany Space Sciences Lab., UC Berkeley, USA CNES, Toulouse, France INFN Genova.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
J. Tinslay 1, B. Faddegon 2, J. Perl 1 and M. Asai 1 (1) Stanford Linear Accelerator Center, Menlo Park, CA, (2) UC San Francisco, San Francisco, CA Verification.
Simulations with MEGAlib Jau-Shian Liang Department of Physics, NTHU / SSL, UCB 2007/05/15.
etc… Analysing samples with complex geometries Particles Inclusions
1 M.G. Pia et al. The application of GEANT4 simulation code for brachytherapy treatment Maria Grazia Pia INFN Genova, Italy and CERN/IT
Cross section measurements for analysis of D and T in thicker films Liqun Shi Institute of Modern Physics, Fudan University, Shanghai, , People’s.
Validation of the Bremsstrahlung models Susanna Guatelli, Barbara Mascialino, Luciano Pandola, Maria Grazia Pia, Pedro Rodrigues, Andreia Trindade IEEE.
Geant4 simulation of the attenuation properties of plastic shield for  - radionuclides employed in internal radiotherapy Domenico Lizio 1, Ernesto Amato.
Evaluation of G4 Releases in CMS (Sub-detector Studies) Software used Electrons in Tracker Photons in the Electromagnetic Calorimeter Pions in the Calorimeter.
Workshop on Physics on Nuclei at Extremes, Tokyo Institute of Technology, Institute for Nuclear Research and Nuclear Energy Bulgarian Academy.
Geant4: Electromagnetic Processes 2 V.Ivanchenko, BINP & CERN
Sergey Ananko Saint-Petersburg State University Department of Physics
St. Petersburg State University. Department of Physics. Division of Computational Physics. COMPUTER SIMULATION OF CURRENT PRODUCED BY PULSE OF HARD RADIATION.
Summary of Work Zhang Qiwei INFN - CIAE. Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases.
FRANK LABORATORY OF NEUTRON PHYSICS ION BEAM ANALYSIS STANCIU-OPREAN LIGIA SUPERVISOR DR. KOBZEV ALEXANDER.
Space Instrumentation. Definition How do we measure these particles? h p+p+ e-e- Device Signal Source.
Geant4 Electromagnetic Physics Introduction V.Ivanchenko, M.Maire, M.Verderi  Process interface  Physics categories  Electromagnetic physics  PhysicsList.
Implementing a dual readout calorimeter in SLIC and testing Geant4 Physics Hans Wenzel Fermilab Friday, 2 nd October 2009 ALCPG 2009.
DDEP 2012 | C. Bisch – Study of beta shape spectra 1 Study of the shape of  spectra Development of a Si spectrometer for measurement of  spectra 
Biomedical Mechatronics Lab M ONTE C ARLO M ODELING AND A NALYSIS OF S TRUCTURED C S I S CINTILLATOR - COUPLED P IXEL D ETECTORS Chang Hwy Lim, Ho Kyung.
IEEE NSS 2012 IEEE NSS 2007 Honolulu, HI Best Student Paper (A. Lechner) IEEE TNS April 2009 Same geometry, primary generator and energy deposition scoring.
Susanna Guatelli & Barbara Mascialino G.A.P. Cirrone (INFN LNS), G. Cuttone (INFN LNS), S. Donadio (INFN,Genova), S. Guatelli (INFN Genova), M. Maire (LAPP),
Performance limits of a 55  m pixel CdTe detector G.Pellegrini, M. Lozano, R. Martinez, M. Ullan Centro Nacional de Microelectronica, Barcelona, 08193,
Hadronic Interaction Studies for LHCb Nigel Watson/Birmingham [Thanks to Silvia M., Jeroen v T.]
Calorimeters Chapter 4 Chapter 4 Electromagnetic Showers.
2. RUTHERFORD BACKSCATTERING SPECTROMETRY Basic Principles.
A Study of Background Particles for the Implementation of a Neutron Veto into SuperCDMS Johanna-Laina Fischer 1, Dr. Lauren Hsu 2 1 Physics and Space Sciences.
Simulation of the energy response of  rays in CsI crystal arrays Thomas ZERGUERRAS EXL-R3B Collaboration Meeting, Orsay (France), 02/02/ /03/2006.
Detector Simulation Presentation # 3 Nafisa Tasneem CHEP,KNU  How to do HEP experiment  What is detector simulation?
8 June 2006V. Niess- CALOR Chicago1 The Simulation of the ATLAS Liquid Argon Calorimetry V. Niess CPPM - IN2P3/CNRS - U. Méditerranée – France On.
Precision Validation of Geant4 Electromagnetic Physics Geant4 DNA Project Meeting 26 July 2004, CERN Michela.
Precision analysis of Geant4 condensed transport effects on energy deposition in detectors M. Batič 1,2, G. Hoff 1,3, M. G. Pia 1 1 INFN Sezione di Genova,
Effects of Surrounding Materials on Proton-Induced Energy Deposition in Large Silicon Diode Arrays Christina L. Howe 1, Robert A. Weller 1, Robert A. Reed.
NA62 Gigatracker Working Group 28 July 2009 Massimiliano Fiorini CERN.
Chapter 5 Interactions of Ionizing Radiation. Ionization The process by which a neutral atom acquires a positive or a negative charge Directly ionizing.
1ECFA/Vienna 16/11/05D.R. Ward David Ward Compare these test beam data with Geant4 and Geant3 Monte Carlos. CALICE has tested an (incomplete) prototype.
DVCS – Hall A Study of the Background Noise HUGS 2008 Florian ITARD.
Physics Data Libraries: Content and Algorithms for Improved Monte Carlo Simulation Physics data libraries play an important role in Monte Carlo simulation:
K. Jahoda, 6 Aug 2007 X-ray School, GWU Proportional Counters Some of what you should know in order to use proportional counters for Spectroscopy, Timing,
Validation of EM Part of Geant4
NANO5 – Geant4 related R&D for new particle transport methods M. Augelli, M. Begalli, T. Evans, E. Gargioni, B. Grosswendt, S. Hauf, C. H. Kim, M. Kuster,
Validation of the bremssrahlung process IV Workshop on Geant4 physics validation Susanna Guatelli, Luciano Pandola, Maria Grazia Pia, Valentina Zampichelli.
Numerical Model of an Internal Pellet Target O. Bezshyyko *, K. Bezshyyko *, A. Dolinskii †,I. Kadenko *, R. Yermolenko *, V. Ziemann ¶ * Nuclear Physics.
Validation of Geant4 EM physics for gamma rays against the SANDIA, EPDL97 and NIST databases Zhang Qiwei INFN-LNS/CIAE 14th Geant4 Users and Collaboration.
meeting, Oct. 1 st 2015 meeting, Oct. 1 st Gas Pixel: TRD + Tracker.
Introduction to Hadronic Final State Reconstruction in Collider Experiments Introduction to Hadronic Final State Reconstruction in Collider Experiments.
1 Activation by Medium Energy Beams V. Chetvertkova, E. Mustafin, I. Strasik (GSI, B eschleunigerphysik), L. Latysheva, N. Sobolevskiy (INR RAS), U. Ratzinger.
Proposed Laboratory Simulation of Galactic Positron In-Flight Annihilation in Atomic Hydrogen Benjamin Brown, Marquette University, Milwaukee, WI, USA.
Validation of GEANT4 versus EGSnrc Yann PERROT LPC, CNRS/IN2P3
Geant4 Simulation for KM3 Georgios Stavropoulos NESTOR Institute WP2 meeting, Paris December 2008.
MCS overview in radiation therapy
Charge transport model for Swept Charge Devices (SCD) P. S. Athiray Post Doctoral Research Fellow, Manipal Centre for Natural Sciences, Manipal University,
A Study of Reverse MC and Space Charge Effect Simulation with Geant4
Performance of the Medipix and Timepix devices for the recognition of electron-gamma radiation fields C. Teyssier1,3, J. Bouchami1, F. Dallaire1, J. Idarraga1,
Hadronic physics validation of Geant4
Geant4: Electromagnetic Processes 2
The Hadrontherapy Geant4 advanced example
Precision validation of Geant4 electromagnetic physics
The Geant4 Hadrontherapy Advanced Example
Presentation transcript:

Precision Analysis of Electron Energy Deposition in Detectors Simulated by Geant4 M. Bati č, S. Granato, G. Hoff, M.G. Pia, G. Weidenspointner 2012 NSS-MIC Anaheim, CA Oct. 29 – Nov. 3, 2012

Why electrons (in) matter e - are of fundamental importance for a multipurpose Monte Carlo tool such as Geant4 o most detectors: measured signal is energy deposited by ionization, i.e. energy imparted on e - o many applications: e- are primary particles, or important constituents of a particle cascade e - are intrinsically difficult to simulate o photons: discrete interactions o electrons: on microscopic level, discrete interactions, but usually a condensed transport scheme is employed to avoid IR divergence ⇒ requires model for multiple scattering (continuous energy loss) ⇒ Geant4: mix of continuous and discrete energy loss

eROSITA eROSITA: extended Roentgen Survey with an Imaging Telescope Array launch 2014 on Russian-German mission Spectrum-X-gamma energy range 200 eV to 10 keV first imaging all-sky survey in 2.5 – 10 keV ⇒ observation of 10 5 clusters of galaxies ⇒ structure formation, dark energy, … Seven X-ray telescopes, each with a pnCCD developed at MPI HLL pnCCD calibration ⇒ X-ray spectral response of pnCCDs (external or on-chip optical/UV blocking filter) MPE AIP

eROSITA X-ray spectral response Measurement: BESSY II at PTB Berlin – 11 keV photons Simulation: Geant4 version 9.2 p02 + HLLDetSim S. Granato good agreement

eROSITA X-ray spectral response Measurement: BESSY II at PTB Berlin – 7 keV photons Simulation: Geant4 version 9.2 p02 + HLLDetSim S. Granato good agreement

eROSITA X-ray spectral response Measurement: BESSY II at PTB Berlin – 3 keV photons Simulation: Geant4 version 9.2 p02 + HLLDetSim S. Granato overall good agreement, but deviations due to low energy e - generated close to volume boundaries (photon absorption length 3 μm)

eROSITA X-ray spectral response Measurement: BESSY II at PTB Berlin – keV photons Simulation: Geant4 version 9.2 p02 + HLLDetSim S. Granato No good agreement, problems due to low energy e - generated close to volume boundaries (photon absorption length < 2 μm)

eROSITA X-ray spectral response Measurement: BESSY II at PTB Berlin – keV photons Simulation: Geant4 version 9.2 p02 + HLLDetSim S. Granato overall good agreement, but deviations due to low energy e - generated close to volume boundaries (photon absorption length < 20 μm)

e - and X-rays at volume boundaries Photo-electric effect: expected behaviour at volume boundaries S. Granato X rays Si bulkentrance windowvacuum

e - and X-rays at volume boundaries Electron energy loss by ionization: pronounced discontinuities / spikes at volume boundaries Origin unknown… (related to multiple scattering algorithm?) S. Granato 50 keV electrons Si bulk 50 keV electrons entrance window

Validation of Geant4 with Sandia electron data validation of Geant4 requires adequate experimental data to our knowledge: no suitable experimental electron data for energies below 25 keV BUT: Sandia National Laboratory precision data for 25 keV – 1 MeV e -, for various incidence angles and materials ⇒ reference for validation of electron transport models o SAND , Lockwood et al., 1987a Calorimetric Measurement of Electron Energy Deposition in Extended Media – Theory vs Experiment ⇒ validate energy deposition as a function of depth o SAND , Lockwood et al., 1987b Electron Energy and Charge Albedos – Calorimetric Measurement vs Monte Carlo Theory ⇒ validate electron backscattering and total energy deposition

Validation of Geant4 with Sandia electron data status report work is ongoing current work based on and extends A. Lecher, M.G. Pia and M. Sudhakar, 2009, TNS 56, pp. 398 ff. Validation of Geant4 Low Energy Electromagnetic Processes against Precision Measurements of Electron Energy Deposition same analysis procedure for consistency

Simulation configuration semi-infinite layer e - beam calorimeter front foil Sandia79: calorimeter placed at different depths all volumes same material Sandia80: single sensitive volume Geometry: as in experiment e - /γ physics: o low energy EEDL/EPDL (“Livermore”) o low energy Penelope o standard Multiple scattering models: o Urban o Goudsmit-Saunderson Secondary e - production threshold: o 250 eV (low energy, Penelope) o 1 keV (standard) Step limitation: o 1, 10, 1000 μm o no limitation Geant4 versions (with latest patches) 8.1, 9.1, 9.2, 9.3, 9.4, 9.5, 9.6-β

Validation analysis Compatibility of simulation with experiment: o  2 test o  2 test case: target material, beam energy, beam incidence angle o significance of  2 test: α = 0.01 Efficiency of a Geant4 physics model: o fraction of test cases in which simulation is compatible with experiment Significance of difference in accuracy between models or versions: o categorical analysis  G4model = N  >0.01 N tot

Total energy deposition Single volume of single-element material – simplest possible test case! Used default settings for all models (Geant4 optimized parameters) ⇒ highest efficiency (best version): Geant4 9.1 ⇒ Geant4 9.4: very poor, dependence on step limitation…!

Energy deposition profiles Test case: Carbon, 1 MeV, θ = 90˚ Layers of single-element material – second simplest possible test case! Used default settings for all models (Geant4 optimized parameters) ⇒ Best Geant4 version: 9.1

Note: Geant  similar to 9.5 Energy deposition profiles Test case: Carbon, 1 MeV, θ = 90˚ Most accurate Geant4: o version 9.1 o “Livermore” model equivalence of Geant4 versions and models: o 9.1 and 9.5: p-value = o “Livermore” and Penelope: p-value = o “Livermore” and standard: p-value < 0.001

Conclusions Accuracy of e - energy deposition in Geant4 depends on: o use case o software version o physics model Best choice for low energy electrons: Geant4 version 9.1 with “Livermore” model Final results will be published soon in TNS – stay tuned…