Introducing the Varian 356-LC Refractive Index Detector

Slides:



Advertisements
Similar presentations
1 The YL9100S HPLC All your needs for semi-preparative applications.
Advertisements

Gas Chromatography Introduction 1.) Gas Chromatography
Chromatography Integration and Trouble-shooting
Evaporative Light Scattering Detector Product Range
Compact & Perfect for Your Satisfaction
Electric Circuits Notes
Analog to Digital Converters (ADC) 2 ©Paul Godin Created April 2008.
Market introduction CellaTemp PA.  Newest interface technology  Latest high-resolution microprocessors  Newest sensors  New amplifier technology 
Chromatography.
Evaporative Light Scattering Detector
AccuMax Multi-Point Injection Mechanics
3D Micromanufacturing Lab. School of Mechatronics Gwangju Institute of Science and Technology 3D Micromanufacturing Lab. School of Mechatronics Gwangju.
Gas Liquid Chromatography
Introducing the LEO 1400 Series
Chapter 6 - Chromatography
Introduction to the HPLC ChemStation and Acquisition.
High Performance Liquid Chromatography
Electronics for PS and LHC transformers Grzegorz Kasprowicz Supervisor: David Belohrad AB-BDI-PI Technical student report.
High Sensitivity Smoke Detection
Method conditions Excellent resolution and fast run times 2 x OligoPore, 4.6 x 250 mm columns gave excellent oligomeric resolution for the PS 580 sample.
High Performance Liquid Chromatography Instrumentation.
ProStar 210/218 Solvent Delivery Modules
ProStar 325 Detector Petro van Poppel – Field Support Specialist Friday, 9 October 2015.
Varian 920-LC Integrated Analytical HPLC
Using Linear Scale-up Principles and the Varian 940-LC with Scale-Up Module for the Isolation of 5-Hydroxytryptophan from Griffonia Simplicifolia Dennis.
Simple Scale-up on a 940-LC Analytical to Preparative HPLC
900-LC P. van Poppel – Field Support Specialist October 2009.
Comparison of Competitors’ Evaporative Light Scattering Detectors
Varian 900-LC Series iHPLC
VARIAN, INC. HPLC Products
Sphere Standards and Standard Spheres Dr. Richard Young Optronic Laboratories, Inc.
1 Varian 940-LC Analytical to Prep HPLC. 2 Varian 940-LC Silver Bullets The 940-LC one instrument – many uses: –High performance automated Analytical.
Analysis of Ibuprofen in Tablets According to the US Pharmacopoiea using a Varian 920-LC Analytical HPLC and Pursuit ® XRs column By Phuong Truong Varian.
Sales Objections and FAQ’s 940-LC Analytical to Preparative Systems.
Comparison of Competitor
Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.
First Impressions Compact, modern design Flat top Small footprint, stackable Operation via control panel and simple keypad Column connection at front of.
Sales Objections and FAQs 920-LC Analytical Systems.
ProStar 500 CVM P. van Poppel – Field Support Specialist October 2009.
PL-ELS 2100 Ice. PL-ELS 2100 Ice Evaporation at Sub Ambient Temperatures The PL-ELS 2100 Ice comprises an Integrated Cooled Evaporator in combination.
HPLC Introduction & Safety P. van Poppel – Field Support SpecialistMarch 2010.
Varian Integrated HPLC Systems (iHPLC) Frankie Button HPLC Instrument Manager, Europe Region 1 November 2007.
Diagnostics – Detectors Analytical 920 LCSemi-Prep 940 LC.
Introducing the PL-ELS 2100 & PL-ELS 2100 Ice Evaporative Light Scattering Detector Presentation to describe the state-of-the art developments in ELS.
High Performance Liquid Chromatography. The chromatogram is a record of detector output Vs time as the analyte passes through the chromatography.
HPLC – High Performance Liquid Chromatography
Introduction to training
212-LC Pump Technology Background August Dual Piston Pump Single piston pumps deliver then refill, forcing the use of a very large pulse damper.
The Chromatogram  Terms:  Retention time  Peak area  Peak width (at half height, at base)  Peak height  Void time/volume  Adjusted retention time.
Created with MindGenius Business 2005® Instrumentation (1) Instrumentation (1) Origins Preparative column chromatography (Glass columns) Internal diameter:
HPLC.
Chapter 28 High Performance Liquid Chromatography.
LC/MS Chromatography Systems 212-LC. 2 The Complete Solution Varian LC components, pumps, autosamplers and the New MS Workstation SW (V6.6) can be used.
Lecture 8 Peak Parameters and Quantitative chromatography
Instrumental Analysis (I)  HPLC Tutorial #7 PHCMt561 – 5 th Sem. Pharm.
PCAR Precision In Practice 1 Precision In Practice Achieving the best results with precision Digital Multimeter measurements Paul Roberts Fluke Precision.
MECH 373 Instrumentation and Measurements
Digital Light Sources First introduced in 2001.
C1300 advanced circular chart recorder
LIQUID CHROMATOGRAPHY
LIQUID CHROMATOGRAPHY
Chromatography- TLC & HPLC
MP3L David Keng, Monica Agarwal 03/17/2008
Hemodialysis Lecture 3.
Varian 940-LC Analytical to Prep HPLC
Size Exclusion Chromatography (SEC)
Running the BioLogic DuoFlow Starter Kit
Diagnostics Analytical 920 LC Semi-Prep 940 LC
Chromatography Daheeya Alenazi.
Gas chromatography Software
Presentation transcript:

Introducing the Varian 356-LC Refractive Index Detector

Introduction The Varian 356-LC detector is being introduced to replace the ProStar 355 detector. The 356-LC detector was designed and built at Polymer Labs, UK. The Varian 356-LC is a high performance refractive index detector designed to meet virtually all customer needs for refractive index detection. This universal detector is ideal for the analysis of non-absorbing compounds such as polymers, carbohydrates, alcohols, and fatty acids.

Overview The Varian 356-LC has been designed to integrate into the ProStar range of detectors. Status LED Showing Power, Purge, zero and error Leak drain Hinges for “Barbie” shower 211 mm 477 mm 296 mm Access panel to connections On/Off switch

Overview Outlet Inlet Waste for internal leaks

Principle of Operation Refractive index detectors are universal detectors designed for analysis of compounds that do not strongly absorb UV light and, therefore, cannot be assayed with a UV detector. The usual compounds analyzed are sugars, polymers, aliphatic amines, organic acids, and alcohols. The Varian 356-LC is functionally identical to other deflection type refractive index detector, it comprises: LED light source, 6 µL flowcell with reference and sample compartments split photodiode detector The complete assembly is housed in a thermally controlled block to maintain baseline stability.

Principle of Operation Generic diagram of the Varian 356-LC Refractive Index Detector

Principle of Operation When both cell compartments contain the same solvent, the light beam is positioned equally on the two detector diodes I1 and I2 When solvent containing a compound passes through the sample side of the cell the difference in refractive index causes the light beam to be proportionally deflected (according to Snell’s refraction law). The change in light intensities between I1 & I2, is proportional to concentration and refractive index of the sample solution. I1 I2 Refractive index is a bulk property of the mobile phase and is very sensitive to changes in ambient temperature RI detectors are also sensitive to flow-rate changes and cannot be used for gradient elution.

Internal Flow Path Normal Operating Conditions: Purge Conditions: The incoming solvent passes into & out of the sample side of the flowcell, then to waste Purge Conditions: The incoming solvent passes into sample & reference side of the flowcell, before going to waste The Varian 356-LC has only 15 µL of volume between inlet and cell to keep dispersion to a minimum The maximum recommended flow rate permitted through the Varian 356-LC Detector is 10 mL/min

Operational Parameters Purge When Purge is selected, the purge indicator light is highlighted, and solvent flow is diverted through the reference side of the RI cell, instead of the sample side; before going to waste. The purge time can be adjusted to compensate for different solvents & eluent flow rates. Auto-Zero The detector output is re-set to zero when the auto-zero function is selected. An error will occur if the auto-zero process takes longer than 5 minsn Response Time The Varian 356-LC has a default response time of 1.0 second, with a settable range of 0.1 –5.0 seconds.

Operational Parameters Sensitivity The sensitivity of the Varian 356-LC can be adjusted to provide greater flexibility. The three possible sensitivity settings are described below: Low - Suitable for highly concentrated samples (e.g. Prep LC) Standard - Default setting, ideal for the majority of LC applications High - Suitable for samples of low concentration in order to maximize signal‑to‑noise. Temperature The temperature of the Varian 356-LC can be set between 30-50 °C (1 °C increments) or turned off. The default value is 35 °C. It is recommended that the temperature should be set at least 5 °C above ambient temperature in order to ensure a stable thermal environment.  

Operational Parameters Polarity The output of the Varian 356-LC refractive index detector can be either positive or negative; therefore it is essential that the polarity of the detector signal be configured. The polarity parameter is used to invert the sign of the refractive index data. A positive polarity leaves the data unaffected, whilst a negative polarity essentially inverts the chromatogram.   Baseline Offset The baseline offset of the Varian 356-LC can be set between the ranges –100 to +100 µRIU.

Not Ready (i.e. changing temp) Front Panel Status The Varian 356-LC, like other Varian modules, has no front-panel display or hard-key control. Full functionality is provided by Galaxie CDS, which gives the user greater flexibility and control than the ProStar 355. Three indicator lights are located at the top left of the front panel of the module to display the status of the instrument Status Color Ready Not Ready (i.e. changing temp) Error Green Orange Red Auto-zero on Purge on

Galaxie Control The Varian 356-LC can be connected directly to the PC via an RS232 connection, for full Galaxie Control Detector output and status quickly accessed in overview window Status window displays all current detector conditions A/Z & purge function easily accessed

Galaxie Control All detector parameters can be changed via the configuration window Send button downloads settings to detector

Key Benefits Sensitivity Baseline Stability Superior Peak Shape The Varian 356-LC provides three sensitivity settings, HIGH, STD & LOW, that can be selected according to the type of analysis. For example, the LOW setting is ideal for preparative LC in order to prevent the signal from saturating at the high concentrations typically encountered. Baseline Stability Flow cell thermostating in the Varian 356-LC eliminates temperature effects on the RI baseline. Stable baselines mean lower detection limits for both analytical and preparative applications. Temperatures are controlled in one degree increments from 30 °C to 50 °C. Superior Peak Shape The custom designed 6µL ‘flow-efficient’ cell for minimal peak dispersion delivers outstanding peak shape, and superior resolution.

Key Benefits: Superior Peak Shape At 1 mL/min the Varian 356-LC peak width* is 50% narrower than the ProStar 355 Varian 356-LC ProStar 355 *measure at ½ height

Key Benefits: Superior Resolution The Varian 356-LC provides better resolution between peaks than the ProStar 355. Resolution 1.17 This is beneficial when analysing compounds of similar properties under isocratic conditions. Resolution 1.18

Key Benefits: Automating the 356-LC Fully Automated via Galaxie Galaxie Software from Varian provides control and automation capabilities. The detector can be automatically purged prior to analysis for overnight operation. The Varian 356-LC can be externally controlled, permitting a device (for instance, a pump) to automatically activate functions such as electronic optical zero and reference cell flush. Digital Data Acquisition Unlike the ProStar 355 the Varian 356-LC offers the user a digital data signal, which can be taken directly into a PC, using an RS232 cable, without the need for an MIB800 module.

Automation via Galaxie Software Detector settings can be saved in a Galaxie method along with pump program for individual applications Automatic Purge and A/Z are possible within a Galaxie method Varian 356-LC can be automated using a sequence of Galaxie methods

Applications: Carbohydrates in Fruit Juice A cost-effective and simple separation to identify food adulteration in fruit juice can be achieved using the Varian 356-LC and PL-Hiplex columns.

Applications: Maltodextrin in Sports Drink The low dispersion characteristics of the Varian 356-LC provides excellent resolution for maltodextrin analysis in sports beverages.

Applications: Epoxy Resins The Varian 356-LC is ideal for GPC analysis, when combined with Galaxie and Cirrus GPC software.

Product Positioning The Varian 356-LC and PL-ELS 2100 ELSD are both universal detectors and should have distinct positions in the market place: ELSDs are typically more expensive than RID, and there is no justification for the higher cost and added complexity of method development if the RI detector can already adequately perform the analysis. The Varian 356-LC should be positioned as a high performance general use refractive index detector with low noise, excellent thermal control & advanced capabilities such as automatic purge & auto zero using Galaxie software.

Varian 356-LC Features & Benefits Feature Benefit Low dead-volume flow-cell Improved resolution and sensitivity Active temperature compensation Lower base-line drift and improved reproducibility Galaxie Control Improved productivity through automated, unattended sequence runs Easy to use and consistent user interface Improved traceability using Galaxie operation logs Digital data output Simple to set up Better value – do not need an expensive analog to digital interface board Long-Life LED Reduced maintenance and quick start-up as the LED is always on and has a indefinite life time

Varian 356-LC Specifications RI range (RIU) 1.0~1.75 Range (µRIU) 150-600x10-6 RIU/FS Linearity (µRIU) 600 Sensitivity (mV/µRIU) LOW (2), STD (4), HIGH (8) Short-term noise (nRIU) <5.0 Drift (nRIU/hr) <250 Response time (s) 0.1–5.0 Temperature control (°C) OFF, 30–50 (1 °C increments) Cell volume (µL) 6.0 Light source LED 880 nm Analog output 1V FSD Digital output 24 bit (10 Hz) via serial port Flow rate range (mL/min) 0.1–10 Dimensions (w x d x h) (unpacked) 296 x 475 x 212 mm  PC control (software) Galaxie Software 200mm 200mm 415mm 450mm 450mm

Ordering Information Varian 356-LC Detector PL0880-0000 Packing List Manual for Varian 356-LC detector PL0880-0010 1.5M PTFE Outlet Tubing assembly PL0880-0300 Aux I/O Cable (5 m) PL0860-0055 RS232 Communication cable PL091-24950 Green Half Moon Door 01 107288 00 Door Cap 09 102066 00 Accessories Analogue Cable PL0880-0310 Mains Inlet Fuses (pk 5) PL0860-0420 Field Upgrades LED assembly PL0880-0110 Flow Cell PL0880-0120 Cell Seals (Top) PL0880-0150 Cell Seals (Bottom) PL0880-0160 Purge Valve PL0880-0210

Product Information Folder (PIF) * The Varian 356-LC PIF contains additional information *