Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION.

Slides:



Advertisements
Similar presentations
Titan EP Training For Programming a New Titan EP August 11, 2009.
Advertisements

Titan EP Training For Modifying a Preprogrammed Titan EP August 11, 2009.
Tuono Dashboard and immobilizer new features 1 2 Dashboard
DS|POWER DS300 series New generation DSP controlled Uninterruptible power supplies.
CL100D series DSP controlled Uninterruptible power supplies.
سیستم آلارم دیجیتالی مجهز به ثبات خطا
Square D Electrical Protection And Monitoring
When the Easy Fridge/Freezer Alarm is plugged into the wall it will ‘boot up’ and display the System Setup Menu Parameter menu will appear where you will.
Model H Free Standing Static Transfer Switch. Why choose a model H static transfer switch? Increases power availability. True solid state. Rugged, reliable.
Model W Wall Mount Static Transfer Switch. Why choose a model W static transfer switch? Increases power availability. Integrated maintenance bypass. True.
ModCon® 75 Controller.
Keypad / Display Keypad/Display Mounting 6 wire shielded cable 10’ length 3 twisted pairs Keypad Three function keys Four directions.
GE job title/1 GE internal information - Not for external distribution 1 GE Security EMEA NPI template – v1 1X Series (phase 1) Conventional Fire Panel.
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
MCS-Connect Intro to Connect Connection and Setup Display Menus Graphics Uses in troubleshooting Overview.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com.
PART-2. Access the functions as described. Accessing functions. To change the accessing password, follow the steps below. Use the NEXT key to select:
FireClass FC501. What’s FC501 ? An entry level Triple Circuit Single Loop addressable system featuring Intelli-Zone mapping An “out of the box” panel.
EDSM II Training. EDSM II EDSM II (Enhanced Digital Select Module) is a hand held program module used to program Atlas laundry dispensers –Recommended.
CheckMeter 2.3 Portable Working Standard Page 1 March 2009.
Monitoring systems COMET types MS55 & MS6 MS55/MS6 Configuration.
G GE Power Management 369 Motor Management Relay.
SEPAM Communications Troubleshooting. Power  Communications module not powered.
What is the It is the Next Generation, Calibration Station for the GasBadge ® Plus Personal Monitor
All content in this presentation is protected – © 2008 American Power Conversion Corporation Symmetra ® LX – redundant UPS High performance, redundant.
1 Starting & Stopping Motors Pico Pico LAB#4. 2 Program a series of three basic ladder logic rungs. These basic rungs are the most common rungs found.
Networking All talk - Selective listen Network up to 15 active nodes + 17 passive nodes Nexus/Discovery panels, network repeaters, R3 19” racks, Alarm.
RP-2000 Series Deluge & Agent Releasing Panels
The Vision of a Leader Rapid Eye Plus Technical Training.
Looking for a more powerful circuit monitor?
FG Wilson Access 4000 Control Panel
ICC Features Features Supporting unlimited projects per ICC –Advanced technical support Friendly registration utility 5 password-levels exceptional workspace.
Single Loop Analogue addressable fire control Panel
SFT 2841 IN CONNECTED MODE Prepare setting files.
Electrical Distribution Training
ECP Extinguishing Control Panel. Extinguishing Control Panel General overview Technical overview.
An Introduction to the R3 19 inch Rack The R3 control system comprises a number of different plug in modules, each of which is dedicated to a particular.
RPTCS Automatic Transfer Control System Low and Medium Voltage Power Transfer Control.
HP900 (ESP Protocol) Analogue Addressable Control Panels
Introducing the UHC-HD for McDonald’s
Electrical Distribution Training
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
EE330 Final Project Lithium Battery Monitor Evan Adkins and Brandon Umscheid.
SFT2841 disconnected Prepare setting files Experts: L.GIGLI
SmartMQn Motor Horner APG, LLC September 9, 2008.
MCS-Connect Revision - 12/22/2015.
Service Section Technical Training December 2005.
CheckMeter 2.1 Portable Working Standard Page 1 March 2009.
Multifunctional LCD Panel HDL-MPL8.48. LCD Panel Description The HDL-MPL8.48 series is a new generation of wall mounted switch, with a total of 8 metal.
Display System for 6400/6300 Protec Alarm Control Systems. Series of Graphic Screens shows all Addressable Devices and their status indication Complicated.
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
1 i-Pendant for the R-J3iC & R-30iA Controllers ArcTool Version (GMAW) i Pendant New.
Puissant Panel User Training Esc.. 09:11:35 ACTIVE # * 3 6 RESET SYSTEM CLEAR DISPLAY TEST DISPLAY SILENCE BUZZER ESCAPE ENTER SILENCE.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
G GE Power Management 269Plus Motor Management Relay.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
All Freezer Advance. When the Freezer is first supplied with power or if a power outage occurs, the display will indicate this by flashing the temperature.
KM SERIES VENDING MACHINES OPERATION MANUAL. ARM Main board & Driver Board DRIVING BOARD MAIN BOARD.
DIGITAL MULTIMETER DMG
MPU-16A / FPU-16 TEST UNIT TUTORIAL
Grid feeding monitoring relay
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
PowerLogic™ offer for the basic metering market
easYgen-3000XT Series Training
Nellcor™ Bedside SpO2 Patient Monitoring System, PM100N - Home use
Presentation transcript:

Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs SEPAM UMI OPERATION Use the different UMIs

Series 80 Remote advanced UMI Integrated advanced UMI Mimic-based UMI Series 20 & 40 Basic UMI Different SEPAM UMIs

Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs DESCRIPTIONS Descriptions

Basic UMI Display Series 80Series 20 & 40 –none on front panel Keypad LEDs –Reset key –9 LEDs –none – 2 LEDs visible on rear panel indicate Sepam operating status

Remote advanced UMI, and integrated UMI Graphic LCD display, 128 x 64 pixels, with backlighting 9-key keypad –Black keys for current operation –Blue keys for parameter and protection setting LEDs –2 LEDs for Sepam operating status –9 indication LEDs Series 20, 40 & 80 The remote UMI must be connected to a base unit without UMI by a CCA77x cord.

Mimic-base UMI Graphic LCD display, 128 x 240 pixels, with backlighting 9-key keypad –Black keys for current operation and parameter/protection setting –Blue key to confirm selection –White and red keys to control devices LEDs –2 LEDs for Sepam operating status –9 indication LEDs Remote / Local / Test selector switch Series 80

Description of advanced UMI PC connection Green ON LED Red Fault LED 9 indication LEDs Metering Switchgear, network and machine diagnosis Alarms LED test Acknowledge and clear alarms Reset Sepam Entry of password Setting of protection functions activated via SFT2841 Sepam characteristics Confirm user choices Move cursor up Move cursor down Series 20, 40 & 80

Description of advanced UMI DoorCartridge Battery –same display as SEPAM 20 & 40 –plus: Series 80

Entry of password MeteringDiagnosis LED test Alarms Protection setting Sepam characteristics Acknowledge and clear alarms Reset Sepam Confirm user choices Move cursor up Move cursor down Description of mimic-based UMI Door Cartridge Battery PC connection Green ON LED Red Fault LED 9 yellow indication LEDs Close switchgear Open switchgear 3-position selector switch Confirm user choices Move cursor up Move cursor down Mimic diagram Series 80

3 categories of users Operator: –Access to all data in read mode only –Clear/Reset actions Personnel qualified to set protection functions –Know the «Setting» code (1 key) –Operator + access to protection settings Personnel qualified to set Sepam parameters –Know the «Parameters» code (2 keys) –Operator + access to protection settings + access to Sepam parameters

Working language All the texts and messages are available in 2 languages: –English, the working language by default –a second, local language –French or Spanish –customized language, created via SFT2840 software

Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs CURRENT OPERATION (BLACK KEYS) Current operation (black keys)

Using the menus Chosen directly from a series of screens in a loop: Press the function key repeatedly to scroll the menus Series 20

Example: metering loop Using the menus 2.Then a series of screens in a loop: 1.A menu page opens for the user to choose a type of data – Press the function key repeatedly to scroll – Press or to select an item – Confirm via the key After the user presses the function key: Series 40 & 80 Vector

4 main functions (black keys) MeteringDiagnosisAlarms Reset Series 80 reset Series 20 & 40

Metering Displays the measurements provided by Sepam Series 20 "Vector" menu: on mimic-based UMI only Series 40 & 80 Vector l1 l2 l3 lo l1 l2 l3 Imoy1 2 3 Imax1 2 3 T1 to T8 V1 V2 V3 U12,32,13 Vo F RMS current measurement Residual current, digital and bargraph Phase current bargraph Average current value Peak demand current Temperature on sensor Phase-to-neutral voltage Phase-to-phase voltage Residual voltage Frequency

Diagnosis Information on switching device and additional measurements to facilitate fault analysis Series 40 & 80Series 20 trip l1, l2, l3, lo unbalance breaking dev. kA 2 E Istart Tstart Nb st, waitT Phase and residual trip currents Unbalance ration (negative sequence) Trip circuit supervision, nb. of operations, operating and charging time Cumulative breaking current Heat rise, Overheating, time before tripping, time before starting authorization Starting current and time Start inhibit time/nb of starts before inhibition Running hour counter Positive sequence voltage Ch Vd Diagnosis Trip -1 Trip -3 Trip -2 Trip -4 Trip 0 Diagnosis

"List" loop: press the button to clear the alarms displayed Used to look up the 16 most recent alarms not yet acknowledged Alarms Alarms are not saved in the event of a power failure. Series 40 & 80Series 20 Alarms ListDetails

«Alarms» menu (cont'd) “Alarm details” loop –The loop presents the details of alarms that have not been cleared (16 maximum). –Alarms that have not been acknowledged are differentiated from acknowledged alarms by the icon: Acknowledged alarm Unacknowledged alarm 2 cases occur when the clear key is pressed –The alarm is not acknowledged: the alarm is acknowledged but not cleared. –The alarm is acknowledged: the alarm is cleared and the user goes on to the next one or to the menu if there are no more alarms. Series 40 & 80

Reset Resets Sepam and / or releases protection latching reset Series 20, 40 & 80 PHASE FAULT

LED test Runs a sequence of LED and display tests No effect when an alarm is present Series 20, 40 & 80

Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs PARAMETER / PROTECTION SETTING Parameter / protection setting (blue keys)

Wrench key For the entry of passwords to access the different modes: –protection setting –parameter setting and return to "operation" mode = no password Series 20, 40 & 80 Password

Status key To display and enter Sepam general settings: –protected equipment characteristics –optional modules Series 20

«General settings» menu Series 40Series 80Series 20 modbus MSA TC / TP O1 main LDC Sepam info MES I / O communication parameter setting analog output module option nb, type, ratio of sensors parameter setting output O1 setting mode, modif, passwords CB control, choice of use of inputs type, version input/output module option In put reading, output reading & testing General settings GeneralModules I/O test Logipam

Protection To display, set and activate/deactivate protection functions Series 40 & 80Series 20 Trip

«Protection» menu (cont'd) There is one field for each protection function (ANSI code), provided access to: Some protection settings may not be adjusted. A specific screen informs the user when this is the case. Only protection functions with at least one unit activated are displayed. Series 80 –protection threshold (if protection setting is allowed on the DSM module). –time delay setting

Current operation (black keys) Descriptions Parameter / protection setting (blue keys) Main points to remember A B C D ? SEPAM UMIs MAIN POINTS TO REMEMBER

Main points to remember 3 Different UMI available matching to the customer needs Protected by PASS WORD for 3 categories of users. Displays the Measurements provided by Sepam Diagnosis of Switching device and Network Displays the 16 most recent alarms Manages Acknowledgement of alarm and Reset Set Protection functions for Sepam 20,40 and Adjust some for Sepam 80 Remote UMI Mimic UMI Advanced UMI