Status of the control system of Alba Introduction The construction of ALBA, the 3 GeV Synchrotron Light Source near Barcelona (Spain) is proceeding according.

Slides:



Advertisements
Similar presentations
SESAME Radiation Safety and PSS Phase I : Microtron + Booster Morteza Mansouri on behalf of Safety group TAC SESAME TAC 2013 : Morteza Mansouri.
Advertisements

Control and IT Systems status and strategy ALBA, Piotr Goryl on behalf of Michał Ostoja-Gajewski, Krzysztof Wawrzyniak, Łukasz Żytniak, Tadeusz.
RTEMS and Linux at the Canadian Light Source Tony Wilson Canadian Light Source University of Saskatchewan.
2002 November 16 CLS PROJECT STATUS M.S. de Jong Project Leader November 16, 2002 Annual Users’ Meeting.
André Augustinus 16 June 2003 DCS Workshop Safety.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Shielding Workshop S. Buda Personnel Protective Systems March 27, 2007.
F. Fernandez 28/10/ Ferran Fernandez WAO2014 Operators training experience at the ALBA synchrotron light source.
Wayne Lewis Australian Synchrotron Beamline Controls Design and Implementation.
F.Brinker, DESY, July 17 st 2008 Injection to Doris and Petra Fitting the detector in the IP-region Radiation issues Beam optic, Target cell Polarisation.
Hamid Shoaee LCLS FAC Review – October Control System Overview Hamid Shoaee Controls System Manager Injector control system commissioning & Support.
EPICS on TPS RF System Yu-Hang Lin Radio Frequency Group NSRRC.
Linac Front-End R&D --- Systems Integration and Meson Lab Setup
Elder Matias Canadian Light Source University of Saskatchewan CLS – Control System Overview.
Marco Lonza, “The Control System of the ELETTRA Booster Injector” ICALEPCS2005, Geneva October 2005 The Control System of the ELETTRA Booster Injector.
DFC on behalf of Pep Ribas and the controls software and electronics group Bliss day out January 15 th 2007.
3 rd Libera Users Meeting – June 2009 Preparation work for ALBA’s Closed-Orbit BPMs 1/33 Preparation work for ALBA’s Closed-Orbit BPMs 3rd Libera Users.
EPICS Insertion Device Control System Pete Owens EPICS Collaboration Meeting June 2003 Control System for a Helical Undulator Pete Owens Daresbury Laboratory.
SESAME PSS Phase I : Microtron + Booster Morteza Mansouri SESAME PSS engineer on behalf of Safety group TAC Morteza Mansouri, SESAME TAC 2012, Nov.10th,2012.
DLS Digital Controller Tony Dobbing Head of Power Supplies Group.
EPICS Collaboration Meeting Spring 2010, Aix France, Jun 2, 2010 Page 1 ITER CODAC COntrol, Data Access and Communication System for ITER Anders Wallander.
NCSX NCSX Preliminary Design Review ‒ October 7-9, 2003 G. Oliaro 1 G. Oliaro - WBS 5 Central Instrumentation/Data Acquisition and Controls Princeton Plasma.
June 14th 2005 Accelerator Division Overview of ALBA D. Einfeld Vacuum Workshop Barcelona, 12 th -13 th September 2005 General 10 th September 2005.
June 14th 2005 Accelerator Division Overview of ALBA D. Einfeld Vacuum Workshop Barcelona, 12 th -13 th September 2005 General 10 th September 2005.
Status of BEPCII Timing System Presented by Ge Lei IMAC 2006.
Micro-Research Finland Oy MRF Timing System Jukka Pietarinen Timing Workshop CERN February 2008.
Problems setting-up the ALBA FOFB Problems setting-up the ALBA FOFB DEELS May - ESRF Angel Olmos.
Stephen Schuh Vacuum Controls SCR and 16 November 2005 Vacuum Controls System Concept Review and Preliminary Design Review.
The microIOC Family Gasper Pajor EPICS Collaboration Meeting Argonne National Laboratory June 2006.
DFC on behalf of controls software and electronics groups Tango meeting March 19 th 2007 Status of Alba Controls.
Instrumentation at CLS (Presentation to Saskatchewan Instrumentation Society Executive) Elder Matias Canadian Light Source University of Saskatchewan
March 2008EPICS Meeting in Shanghai1 KEKB Control System Status Mar Tatsuro NAKAMURA KEKB Control Group, KEK.
Eugenia Hatziangeli Beams Department Controls Group CERN, Accelerators and Technology Sector E.Hatziangeli - CERN-Greece Industry day, Athens 31st March.
Control Hardware Design Control Hardware Wiring IOC Software (Low Level) OPI Software (High Level) Final Test Front-End (Connection to SR1 Ring) Done Insertion.
Oct 8-9, 2005ACS Collaboration Meeting – Archamps, France The MicroIOC From Custom To Production First customer: PSI 25 pieces.
Online Software 8-July-98 Commissioning Working Group DØ Workshop S. Fuess Objective: Define for you, the customers of the Online system, the products.
Booster Top-off Computer Controls System C. Timossi November 22, 2004.
5-Oct-051 Tango collaboration status ICALEPCS 2005 Geneva (October 2005)
Jørgen S. Nielsen Institute for Storage Ring Facilities (ISA) Aarhus University Denmark 1 ESLS-RF 14 (29-30/9 2010), ASTRID and ASTRID2 new LLRF.
1 BROOKHAVEN SCIENCE ASSOCIATES NSLS-II Overview Satoshi Ozaki Director, Accelerator Systems Division NSLS-II Project March 27, 2007.
February 2010 ALBA Synchrotron Light Source Francis Perez.
14 th ESLS RF Meeting – Trieste, September 2010 ALBA RF Status 1/28 ALBA RF Status Francis Perez.
The recent history and current state of the linac control system Tom Himel Dec 1,
ICALEPCS 2007 The Evolution of the Elettra Control System The evolution of the Elettra Control Sytem C. Scafuri, L. Pivetta.
Commissioning of the ALBA IOT-Transmitters Paco Sanchez - 14th ESLS RF - ELETTRA, September Paco Sanchez, RF Group, CELLS (Consortium for.
GAN: remote operation of accelerator diagnosis systems Matthias Werner, DESY MDI.
11 th February 2008Brian Martlew EPICS for MICE Status of the MICE slow control system Brian Martlew STFC, Daresbury Laboratory.
CEA DSM Irfu SIS LDISC 18/04/2012 Paul Lotrus 1 Control Command Overview GBAR Collaboration Meeting Paul Lotrus CEA/DSM/Irfu/SIS.
1 September 2007 – Tango Meeting – A.Buteau ICALEPS 2005 Status report SOLEIL September 2007.
4. Operations and Performance M. Lonza, D. Bulfone, V. Forchi’, G. Gaio, L. Pivetta, Sincrotrone Trieste, Trieste, Italy A Fast Orbit Feedback for the.
Programmable Logic Controller & Distributed Control System Yoon-Je Choi 17 th June 2006.
ALBA RF System Paco Sanchez - 13th ESLS RF - DESY, 30 September Paco Sanchez, RF Group, CELLS (Consortium for the Exploitation of the Synchrotron.
Failure Analysis Tools at DESY. M. Bieler, T. Lensch, M. Werner, DESY ARW 2013, Melbourne,
ICS interfaces Timo Korhonen ICS Apr 22, 2015.
Redundancy in the Control System of DESY’s Cryogenic Facility. M. Bieler, M. Clausen, J. Penning, B. Schoeneburg, DESY ARW 2013, Melbourne,
V Review SPARC Diagnostic & Control Status G. Di Pirro On behalf control and diagnostic group.
Tango Meeting Grenoble September 5/ Claudio Scafuri, Elettra ELETTRA Status Claudio Scafuri
Operation Status of the RF Systems and Taiwan Photon Source
Report Technical Director Storage-Ring-Installation Completed
MicroTCA Development and Status
Operations Machine Simulator.
SESAME Control System Status
J. Meyer European Synchrotron Radiation Facility (ESRF)
Laboratorio per dottorandi 2017 Particle Accelerators Control System
PLC-based control systems at SOLEIL - ICALEPCS 2017
SESAME Control System Status
                                                                       TANGO Collaboration Experience for running a multi-site international software project.
DFC Tango meeting, Hamburg, September 17th 2007
SOLEIL Fast Orbit Feedback System
COntrol, Data Access and Communication System for ITER
Rack installation and local tests for the MEBT Chopper Rack
Presentation transcript:

Status of the control system of Alba Introduction The construction of ALBA, the 3 GeV Synchrotron Light Source near Barcelona (Spain) is proceeding according to schedule. Although the building will be finished on June 2008, the preparation and installation of the components for the Linac is foreseen in November The 100 MeV Linac is manufactured by Thales Commu-nication as a turnkey system. The 3GeV booster and the storage ring are installed in the same tunnel. Picture: September 1 st 2007 Picture: July 1 st 2007 Seven beamlines are being built in the first phase: “XAS: X-ray Absortion Spectroscopy”, “PD: High Resolution Powder Diffraction”, “XALOC: Macromolecular Crystallography”, “NCD: Non-Crystalline Diffraction”, “CIRCE: Photoemission Spectroscopy and Microscopy”, “MISTRAL: Soft X-Ray Microscopy”. One of them is on a bending magnet. Insertion devices are: a Wiggler (W80), a Super-conducting Wiggler (SCW31), two in-vacuum undulators (IVU21) and two Apple2 (EU71 and EU62). Tunnel. Picture: October 1 st 2007 Beamlines: A project for writing a generic tool for beamline control has been started at Alba, and now the European Synchrotron Radiation Facility (ESRF) [8] is collaborating in the development. This “device pool” provides a common way of acquiring data, moving motors, scanning and in general interfacing any device. It is based on Tango, written in C++ and Python. This is very appropriate for beamline controls, diffractometers, detectors, motors, counters, etc. but also for some applications in the accelerator controls. The Icepap electronics is a development of the ESRF.. It is fully configurable by software and accessed by Ethernet or serial lines. RF Storage Ring: six radio frequency plants with a power of 160 kW (two transmitters of 80 kW each). Booster one plant of 80 kW. Pulses in the electron gun are chopped at MHz. A transmitter including a high voltage power supply (HVPS) and an Inductive Output Tube (IOT) has been already installed in the Radiofrequency lab. The control system for the transmitter is based on Siemens Programmable Logic Controllers (PLCs) and delivered by Thomson. The interlock system follows the same philosophy as the general Equipment Protection System (EPS) and uses B&R PLCs with CPUs installed in cabinets outside the tunnel and distributed I/O modules inside the tunnel. Both are interconnected through an X20 bus. Graphical interfaces are written in Python [3] and Qt4 [4] Vacuum Main vacuum electronics is Varian Dual Ion Pump controllers. Gauge controllers are decided in the following weeks. They are interfaced by RS232/RS485. An industrial PC per sector (16 in total) is in charge of the vacuum control. This includes serial connections, Tango servers for the different controllers, and connections with the different PLCs. PLCs manage interlocks of the different devices, as well as temperature readouts. They follow the Alba standard distributed architecture, having a CPU installed in a cabinet in the service area and distributed I/O modules installed inside the tunnel on cable trays. Boxes to be installed in the tunnel are shielded with 1.5 mm of lead. Power Converters All power converters have an Ethernet interface complemented with an external trigger input. Corrector magnets of the storage ring will have a fast link for the fast orbit feedback [6]. They are interlocked with the corresponding magnet flow-switches and thermo-switches by the EPS, and each of them having the corresponding Tango server (implementing the power supply interface) for slow control and data acquisition. Timing system It is based on events where an Event Generator (EVG) produces the event stream that is communicated to multiple Event Receivers (EVR). Transmission to all event receivers is multiplexed with fan-out modules and carried out by optic fibers of the same length. This system follows the same philosophy as SLS, Diamond, Soleil and few other institutes and has been manufactured by Microresearch Finland. Linac The 100 MeV Linac manufactured by Thales Communication. The control system is based on PLCs with 2 interfaces based on a common library. One of the interfaces is for local control, intended to be used for commissioning. Beam dynamics Storage Ring: 88 Libera BPM electronics [5] and 88 correctors in each plane for orbit correction. Corrector magnets are integrated in the sextupoles as extra coils. Data from the Liberas is being distributed among the liberas up to the Compact PCI crate using the protocol developed at Diamond. This data transmission meant to be used for the fast orbit correction uses a dedicated fiber optics link. A tango server for every Libera box runs in the Compact PCI crate and is accessible from the control system for the slow orbit correction, displays, archiving etc... This so called slow control goes over the normal Ethernet link. Graphical user Interface for vacuum B&R PLC of the Equipment Protection system Acknowledgments Many developers are working or have worked in this project. Besides the computing division at Alba, I would like to thank specially E. Taurel, A. Homs, M. Guijarro, and V. Rey from the ESRF. Also special thanks to the Tango collaborators who have written most of the standard Tango Applications and Tools available for the community: ESRF, Soleil and Elettra. Recently Hasylab has also joined the community. References. [1] [2] [3] [4] [5] [6] D. Einfeld et al. “Status of the Alba project”, PAC’07. Albuquerque, June p [7] D. Beltran et al. “Initial design of the global fast orbit feedback for the Alba synchrotron”, These procedures. [8] [9] Conclusion Major choices like Ethernet as field bus, PCI and cPCI, Libera, Icepap, Linux and evidently Tango have been taken. Prototypes have already been implemented mostly for the RF lab which needs an RF control, EPS, Vacuum control, Archivers, Save/Restore, and even a PSS. Choices up to now demonstrated to fulfill all the needs and expectations. However, large scale systems need still to be tested, in particular for the archiver and tango databases Alba: A Tango based Control system. David Fernández Carreiras on Behalf of control groups. ICALEPCS 2007 Hosted by SNS. Oak Ridge, National Laboratory. October 15 – Knoxville. Tennessee. Model of the building PSS The system is based on Safety PLCs from Pilz, following the golden rule of redundancy and diversity. All inputs and outputs like door switches, radiation monitors, emergency stops, shutter limit switches; have redundant cabling, actuators and contacts. The PSS interlocks every RF transmitter (out of 13) in two different ways as well as both klystrons of the Linac and the electron gun. 3D model of the elements installed in the girder. The boxes for Equipment protection system are Installed on the cable tray. 30 CCD cameras for fluorescence screens are also read by Ethernet, using the E-Giga protocol Arquitecture The architecture of the control system is distributed. Boot servers, Tango [2] databases and archivers run on boxes in the computing room. Tango servers run in IOCs (Input Output Controllers) which are linux boxes, most of them diskless. Compact PCI crates are installed in all those devices where a timing event receiver is needed. The remaining ones are Industrial PCs. Beamlines have industrial PCs with disk Ethernet is widely used by the control electronics. Power supplies, Liberas, CCD cameras, Oscilloscopes, and of course IOCs are connected by Ethernet. Most IOCs get a dynamic address by Dynamic Host Configuration Protocol (DHCP). Few VLANS (Virtual Local Area Networks) are defined. The main control, EPS, Liberas, power supplies and diagnostics are separated into different VLANS as most communications are between devices of the same group. The Tango database and databases for archivers (mysql) reside in linux boxes in the computing room whereas fast data loggers for RF and eventually vacuum will store data online. Pilz PLC installed on the cabinet of the PSS of the RF lab TANGO Device Pool configuration tool Icepap configuration and test tool Icepap crate. Graphical user interface for Liberas Liberas installed in the Electronics Lab