3rd NoRDHia 1 TITLE INVESTIGATION OF A SINGLE CRYSTAL DIAMOND SENSOR AND ITS APPLICATION IN BACKGROUND MEASUREMENTS FOR HERA Wolfgang Lange,

Slides:



Advertisements
Similar presentations
Investigation of Proton Irradiation-Induced Creep of Ultrafine Grain Graphite Anne A. Campbell & Gary S. Was University of Michigan Research Supported.
Advertisements

H1 SILICON DETECTORS PRESENT STATUS By Wolfgang Lange, DESY Zeuthen.
Combined Measurement Results of dedicated RD50 Charge Multiplication Sensors Christopher Betancourt 2, Tom Barber 2, Gianluigi Casse 1, Paul Dervan 1,
Design Studies and Sensor Test for the Beam Calorimeter of the ILC Detector E. Kuznetsova DESY Zeuthen.
New approach to simulate radiation damage to single-crystal diamonds with SILVACO TCAD Florian Kassel, Moritz Guthoff, Anne Dabrowski, Wim de Boer.
17-May-15Actual problems of microworld physics. Gomel Investigation of radiation hard sensors for the ILC forward calorimeter K. Afanaciev, Ch. Grah,
17-May-15Actual problems of microworld physics. Gomel Investigation of radiation hard sensor materials K. Afanaciev on behalf of FCAL collaboration.
For the RD42 Collaboration
DIAMOND ACTIVITIES DESY Zeuthen Wolfgang Lange. MOTIVATION and PEOPLE: Calorimetry in an environment with high radiation doses (TESLA beam cal) Beam diagnostics.
Investigation of the properties of diamond radiation detectors
Wide Bandgap Semiconductor Detectors for Harsh Radiation Environments
Measurements on Single and Poly Crystal CVD Diamond Sensors
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
August 2005Snowmass Workshop IP Instrumentation Wolfgang Lohmann, DESY Measurement of: Luminosity (precise and fast) Energy Polarisation.
Secondary Emission Ionization Calorimetry Detectors
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
Current Status of Diamond Sensors R&D in Minsk Group FCAL Collaboration Institute of Nuclear Physics PAN February 12-13, 2006, Krakow, Poland.
Radiation Hard Sensors for the Beam Calorimeter of the ILC C. Grah 1, R. Heller 1, H. Henschel 1, W. Lange 1, W. Lohmann 1, M. Ohlerich 1,3, R. Schmidt.
Semi-conductor Detectors HEP and Accelerators Geoffrey Taylor ARC Centre for Particle Physics at the Terascale (CoEPP) The University of Melbourne.
FCAL R&D in Minsk Group: Sensors and Electronics FCAL Collaboration MPI Munich October 17, 2006, Munich, Germany Presented by Igor Emeliantchik.
22 December 20143rd FCAL Hardware WG Meeting 1 BeamCal sensors overview Sergej Schuwalow, DESY Hamburg.
22 October 2009FCAL workshop, Geneve1 Polarization effects in the radiation damaged scCVD Diamond detectors Sergej Schuwalow, DESY Zeuthen On behalf of.
1 G. Pellegrini The 9th LC-Spain meeting 8th "Trento" Workshop on Advanced Silicon Radiation Detectors 3D Double-Sided sensors for the CMS phase-2 vertex.
14 December nd CARAT Workshop, GSI, Darmstadt1 Radiation hardness studies with relativistic electrons Sergej Schuwalow, Uni-HH / DESY On behalf of.
Calorimeter technologies for forward region instrumentation K. Afanaciev 2, R. Dollan 1 V. Drugakov 2, C. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
GEM: A new concept for electron amplification in gas detectors Contents 1.Introduction 2.Two-step amplification: MWPC combined with GEM 3.Measurement of.
High Dose Irradiation of Possible FCAL Sensors at the S-DALINAC Ch.Grah Physics and Detector Meeting DESY HH,
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
Heavy ion irradiation on silicon strip sensors for GLAST S.Yoshida, K.Yamanaka, T.Ohsugi, H.Masuda T.Mizuno, Y.Fukazawa (Hiroshima Univ.) Y.Iwata, T.Murakami.
SILICON DETECTOR DESY Zeuthen (up to now) By Wolfgang Lange, DESY Zeuthen.
Diamond Detector Developments at DESY and Measurements on homoepitaxial sCVD Diamond Christian Grah - DESY Zeuthen 2 nd NoRHDia Workshop at GSI Thursday,
CVD Diamond Sensor Studies for the Beam Calorimeter of the ILC Detector K. Afanaciev 2, I.Emelianchik 2, Ch. Grah 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C. Grah 1, U. Harder 1, H. Henschel 1, E. Kouznetsova 1, W. Lange 1, W. Lohmann 1, M.
Diamond Sensor Diamond Sensor for Particle Detection Maria Hempel Beam Impact Meeting Geneva,
Heavy ion irradiation on silicon strip sensors for GLAST & Radiation hardening of silicon strip sensors S.Yoshida, K.Yamanaka, T.Ohsugi, H.Masuda T.Mizuno,
8 July 1999A. Peisert, N. Zamiatin1 Silicon Detectors Status Anna Peisert, Cern Nikolai Zamiatin, JINR Plan Design R&D results Specifications Status of.
September 2006 / 1. / 2 1) GaAs, who needs it anyway ? 2) IV - Measurments 3) IT - Measurments 4) CCD - Measurments Overview.
State of the art on epitaxial GaAs detectors
First results from silicon and diamond sensors K. Afanasiev 1, I. Emeliantchik 1, E. Kouznetsova 2, W. Lohmann 2, W. Lange 2 1 NC PHEP, Minsk 2 DESY Zeuthen.
Octobre MPI Munich VFCAL Report W. Lohmann, DESY Laser alignment system Infrastructure for sensor diagnostics Sensor test facilities FE design Labs.
3rd NoRDHia 1 TITLE INVESTIGATION OF DIAMOND SAMPLES UNDER HIGH DOSES OF ELECTROMAGNETIC IRRADIATION (at S-DALINAC) Wolfgang Lange, DESY Zeuthen.
Itzhak Tserruya, BNL, May13, HBD R&D Update: Demonstration of Hadron Blindness A. Kozlov, I. Ravinovich, L. Shekhtman and I. Tserruya Weizmann Institute,
Investigation of CVD Diamonds as Sensor Material for BeamCal Alexandr Ignatenko FCAL Collaboration Meeting, Orsay October 6-7, 2007.
Application of Diamond Sensors at FLASH M.-E. Castro-Carballo, H. Henschel, A. Ignatenko, W. Lange, O. Novgorodova, W. Lohmann, R. Schmidt, S. Schuwalow.
December 7, 2005DESY EUDET in FCAL VINCA, Belgrade Univ. of Colorado, Boulder, BNL, Brookhaven, AGH Univ., INP & Jagiell. Univ. Cracow, JINR, Dubna, NCPHEP,
Electrical features of diamond sensors D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
A Quantum Computer in a Diamond Grant Riley. Outline Requirements for a quantum computer Chemical Vapor Deposition Diamonds – Properties – Impurities.
We are investigating the dependence of efficiency of diamond detector samples on accumulated radiation dose. We have Sr 90  -source of known activity.
A Prototype Diamond Detector for the Compton Polarimeter in Jefferson lab, Hall C Medium Energy Physics Group Amrendra.
Lucia Bortko | Optimisation Studies for the BeamCal Design | | IFJ PAN Krakow | Page 1/16 Optimisation Studies for the BeamCal Design Lucia.
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, E. Kouznetsova, W. Lange, W. Lohmann.
Albuquerque 1 Wolfgang Lohmann DESY On behalf of the FCAL collaboration Forward Region Instrumentation.
Polycrystalline CVD Diamonds for the Beam Calorimeter of the ILC C.Grah ILC ECFA 2006 Valencia, 9 th November 2006.
1 Performance of a CCD tracker at room temperature T. Tsukamoto (Saga Univ.) T. Kuniya, H. Watanabe (Saga Univ.); A. Miyamoto, Y. Sugimoto (KEK); S. Takahashi,
6th Trento Workshop on Advanced Silicon Radiation Detectors1/16 J.P. BalbuenaInstituto de Microelectrónica de Barcelona IMB-CNM (CSIC) J.P. Balbuena, G.
C. Weiss 1, 2, G. Badurek 2, E. Berthoumieux 3, M. Calviani 1, E. Chiaveri 1, D. Dobos 1, E. Griesmayer 4,C. Guerrero 1,E. Jericha 2, F. Kaeppeler 5, H.
Diamond Sensor Tests for the CMS BCM Alexandr Ignatenko FCAL collaboration meeting May 7, 2008.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, Aging test of high rate MRPC Wang Yi Department of Engineering.
Manoj B. Jadhav Supervisor Prof. Raghava Varma I.I.T. Bombay PANDA Collaboration Meeting, PARIS – September 11, 2012.
Investigation of the effects of thickness, pitch and manufacturer on charge multiplication properties of highly irradiated n-in-p FZ silicon strips A.
FCAL R&D towards a prototype of very compact calorimeter
Kröhnke, 14 November 2012 FCAL Collaboration Meeting Sergej Schuwalow
Investigation of diamond sensors for calorimetry
(proxy for Harris Kagan) for the RD42 Collaboration
Testbeam Results for GaAs and Radiation-hard Si Sensors
PERFORMANCE OF THE METAL RADIATION MONITORING SYSTEMS
Radiation hard sensors for ILC forward calorimeter
CVD Diamond Sensors for the Very Forward Calorimeter of a Linear Collider Detector K. Afanaciev, D. Drachenberg, E. Kouznetsova, W. Lange, W. Lohmann.
Diamond Measurements in Zeuthen
Presentation transcript:

3rd NoRDHia 1 TITLE INVESTIGATION OF A SINGLE CRYSTAL DIAMOND SENSOR AND ITS APPLICATION IN BACKGROUND MEASUREMENTS FOR HERA Wolfgang Lange, DESY Zeuthen

3rd NoRDHia 2 OUTLINE OF THIS TALK 1.Motivation 2.The Sensor 3.Measurements 1.Static Measurements 2.Particle Detection (Source) 3.Charge Collection during Irradiation 4.Results 5.Outlook Wolfgang Lange

3rd NoRDHia 3 MOTIVATION Wolfgang Lange Investigation of one of the first available single crystal diamond sensors Not only measurement of properties but also practical use in an application to achieve experience Extend this application into environments with radiation load later

3rd NoRDHia 4 SENSOR Wolfgang Lange Single Crystal (CVD grown on substrate) by E6 About 5 by 5 square millimeters Metallization 3 mm in diameter Thickness 320 µm Connected via ultrasonic Al bonding

3rd NoRDHia 5 MEASUREMENTS (1) Wolfgang Lange Diamond Keithley 487 HV N2N2

3rd NoRDHia 6 MEASUREMENTS (2) Wolfgang Lange

3rd NoRDHia 7 MEASUREMENTS (3) Wolfgang Lange Charge Collection Distance: CCD reaches 50V (100% efficiency, thickness = 320 µm)

3rd NoRDHia 8 MEASUREMENTS (4) Wolfgang Lange Charge Collection Distance: 80V (100% efficiency, thickness = 320 µm), measured for low doses (Sr90)

3rd NoRDHia 9 RESULTS Wolfgang Lange 100% charge collection efficiency, CCD = thickness Stable for low doses Clearly separated spectrum of minimal ionizing particles 1 mip results in 11.5 ke - (1.84 fC)

3rd NoRDHia 10 OUTLOOK Wolfgang Lange application of this sensor in particle counting: use of a preamplifier, put it in a box, interface electronics appointed application: radiation monitor (HERA, Zeus)