Correlation Between Corneal Biomechanics and Wavefront Aberrations Alejandro Rivera, MD Private Practice Mexico City The author has no financial interest.

Slides:



Advertisements
Similar presentations
Asymmetric Keratoconus Study: Novel Tomographic Parameters to enhance sensitivity to detect abnormalities in eyes with normal axial curvature maps from.
Advertisements

Biomechanical Properties of the Cornea in Normal- Tension Glaucoma Authors: Leonidas Traipe Ines Cayuqueo Fabiola Cerfogli Claudia Goya Allister Gibbons.
Statement of Commercial Interest: RDJ: None DRH: honoraria from Reichert for educational lectures on corneal biomechanics Multiple studies have shown ex.
Comparison of Endothelial Cell Count by Manual and Automated Methods in Normal Corneas and in Fuchs' Endothelial Dystrophy Somasheila I Murthy, Debarun.
Corneal biomechanical properties and their association with intraocular pressure (IOP) and central corneal thickness (CCT) Dimitrios P. Bessinis 1, Pandelis.
Incidence of Blepharitis in Patients Undergoing Phacoemulsification Jodi Luchs, MD Carlos Buznego, MD William Trattler, MD The authors of this poster have.
Comparison of corneal astigmatism measured with 3 devices Mariko Shirayama, M.D, Li Wang, M.D, PhD, Mitchell P. Weikert, M.D, Douglas D. Koch, M.D. Cullen.
Correlation Of Corneal Contour With Higher Order Ocular Aberrations (HOA) In Indian Eyes Manish Chaudhary MS Amit Gupta MS Advanced Eye Centre, Postgraduate.
Long-Term Follow-Up of Toric Intraocular Lens Implantation for Keratoconus Alejandro Navas, MD, MSc, Martha Jaimes, MD, Jesús Cabral, MD, Arturo Ramirez.
Corneal Biomechanics, Pachymetric Progression Profile and Corneal Volume: Indices for Detecting Ectasia and Screening Refractive Candidates Renato Ambrósio.
E-Poster ALC Canedo, MD 2010 Rio de Janeiro CornealTomograhyandBiomechanics Study Group Study Group Comparative Study of Corneal Biomechanical Properties.
Purpose We studied the interdevice agreement of three systems in the different measurements of the corneal and anterior segment biometric parameters. The.
Personalised eye modelling for customised intraocular lens designs Matthew Sheehan, Eamonn O’Donoghue, Conor Sheil and Alexander Goncharov Photonics Ireland,
Phacoemulsification with Goniosynechialysis in the Management of Refractory Acute Angle-closure Glaucoma Ghasem Fakhraie*, MD, Mahmoud Jabbarvand, MD,
Outcome of refractive surgery in keratoconus suspect eyes
Repeatability of Anterior and Posterior Corneal Higher- Order Aberrations in 4 mm, 6 mm and 8 mm diameters measured by Pentacam System Jadwiga Wojtowicz.
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. David Zadok, MD, Yakov Goldich, MD, Yaniv Barkana,
Ahmad Kheirkhah MD, Rodrigo Muller MD, Deborah Pavan-Langston MD, Andrea Cruzat MD, Pedram Hamrah MD Ocular Surface Imaging Center, Massachusetts Eye and.
TRANSPALPEBRAL TONOMETER APPLICATION DURING INTRAOCULAR PRESSURE EVALUATION IN THE PATIENTS WITH REFRACTION ANOMALY BEFORE AND AFTER KERATOPHOTOREFRACTIVE.
Evaluation of Interface Reflectivity and Corneal Aberrations following DSAEK Hamid Khakshoor, MD Professor of Ophthalmology Mashhad University of Medical.
Characterization of Higher Order Ocular Aberrations (HOA) In ‘Normal’ Versus Myopic Eyes To Study The Effect Of Myopia On Higher Order Aberrations Amit.
Relationship between Pachymetry and Ocular Response Analyzer Measurements Alejandro Rivera MD.
ASCRS 08 Changes Of Higher Order Aberrations After Excimer Laser Treatment For Moderate Myopia by Means of Preoperative Wavefront Aberration Levels using.
The authors have no financial interest in the subject matter of this poster Yinfei Xu, Peter S. Hersh, MD, David S. Chu, MD Institutional Affiliations.
Tear-film Stability in Patients with Obstructive Sleep Apnea Syndrome Masaki Sato, MD Tetsuro Oshika, MD Department of Ophthalmology University of Tsukuba.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Khairidzan Mohd Kamal MD
Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. Yakov Goldich, MD, David Zadok MD, Yaniv Barkana,
Reproducibility of Optical Measurements in Pseudophakic eyes Using Double-Pass Measurement System St Thomas Hospital, London Anish Dhital, David Spalton,
Endothelial Keratoplasty in Patients With an Anterior Chamber Intraocular Lens: A Montreal Experience Georges M. Durr, MD 1,2 Johanna Choremis, MD, FRCSC.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Myoung Joon Kim, MD / Sara Yoon, MD Tracy Purcell, PhD / David J Schanzlin, MD L aser In Situ Keratomileusis versus Photorefractive Keratectomy for the.
Analysis of Ocular Wavefront Aberrations in Post Penetrating Keratoplasty Eyes with Two Different Hartmann-Shack Aberrometers Adriana S. Forseto 1, MD;
Correlation of Len Aberrations with Incipient Cataracts Using the Tracey iTrace Visual Function Analyzer by Dr. Paulo Pedri Brazil.
A Prospective Trial Comparing Pneumotonometry of Cornea and Sclera Usiwoma Abugo BS 1, Sara Duke MD 2, Shuchi Patel, MD 2 1 Loyola University Chicago,
Adriana S. Forseto1, MD Walton Nosé1,2, MD
E-Poster Rio de Janeiro Corneal Tomography and Biomechanics Study Group The study of the correlations of the optic disc size with Cornal Geometry and Biomechanical.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
The effect of corneal edema on intraocular pressure measurements after phacoemulsification surgery Ilker Eser M.D. 1 Arzu Taskiran-Comez M.D. 1 Baris Komur.
Futoshi Taketani, MD,PhD,
Ocular functional optical zone following hyperopic LASIK/PRK: Analysis based on polychromatic retinal image quality Mitchell P. Weikert, MD Li Wang, MD,
Ocular Response Analyzer Waveform Analysis in the Ectatic Corneas: Correlation of the New Corneal Biomechanics Parameters and Severity of Keratoconus Kristin.
Financial Disclosure: Medical Director–Galilei R&D Consultant, Ziemer Group AG, Port, Switzerland Consultant & Territory Manager for.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Authors: Leonidas Traipe Magdalena Rios Edison Villagra Allister Gibbons Marcelo Hidalgo Claudia Goya Authors have no financial interest.
Wavefront-guided Ablation Retreatment in Myopic Eyes Engy M Mohamed MD, Orkun Muftuoglu MD, R.Wayne Bowman MD, V. Vinod Mootha MD, H. Dwight Cavanagh MD,PhD,
Corneal Hysteresis Role of Corneal Biomechanics in Refractive Surgery Luis Rodriguez, MD Anny Villegas, MD Clínica de Córnea Centro Médico Docente La Trinidad.
BIOMECHANICAL PROPERTIES OF THE CORNEA IN PSEUDO-EXFOLIATION SYNDROME Aylin Kılıç Ertan, MD Özgür Bilen, MD Kudret Eye Hospital, Ankara, Turkey There is.
Corneal Biomechanical Changes Following Surface Keratorefractive Surgery Teeravee Hongyok, MD, Christopher J. Rapuano, MD, Ajoy Virdi, MBBS, Elisabeth.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
CORNEAL ENDOTHELIAL PROFILE AFTER FERRARA RING IMPLANTATION Leonardo Torquetti, MD, PhD Paulo Ferrara, MD, PhD Paulo Ferrara Eye Clinic Belo Horizonte.
Instituto para Preservación de la Visión
Department of Ophthalmology, University of Ulsan College of Medicine,
Comparison of Endothelial Cell Loss After Phacoemulsification Performed by Third Year Residents and Anterior Segment Surgeons Alexandra Braunstein, MD.
Characteristics of Primary Angle-Closure Glaucoma Patients with Normal Intraocular Pressure at the First Visit Won Hyuk Oh1, Bum Gi Kim1, Joo Hwa Lee2.
Charlotte ROHART1, Gilles Chaine1, Damien GATINEL2
Corneal Pachymetry in Prediction of Refraction After Cataract Surgery
Corneal High-Order Aberrations in Keratoconus
Influence of UVA-Riboflavin corneal collagen cross-linking on biomechanical properties of keratoconic eyes David Zadok MD, Yakov Goldich MD, Yaniv Barkana.
L. Espandar, MD ; M. D. Mifflin, MD; M. Moshirfar MD, FACS
Jodi Luchs, MD Carlos Buznego, MD William Trattler, MD
Comparison of corneal powers obtained from four different devices
Asociación Para Evitar La Ceguera En México
Mohamed A Guenena, MD Helga P Sandoval, MD, MSCR Kerry D Solomon, MD
Associate Professor of Ophthalmology
Vicente J. Correa-Gomez MD, Guillermo Tapia MD, Oscar Macias Manuel MD, Alejandro Navas Perez MD, Gilberto Islas MD, Tito Ramírez-Luquin MD, Enrique O.
Federal University of São Paulo, Brazil
Corneal Biomechanics after Penetrating Keratoplasty and Descemet’s Stripping Automated Endothelial Keratoplasty Samer Hamada MRCOphth FRCS(Ed)1,3 Louai.
Jun Her MD. PhD, Sung-wook Kim MD, Jae-hwan Ahn MD
The Effect of Corneal Thickness on Ocular Drug Penetration
Presentation transcript:

Correlation Between Corneal Biomechanics and Wavefront Aberrations Alejandro Rivera, MD Private Practice Mexico City The author has no financial interest in any material or method mentioned Alejandro Rivera, MD Private Practice Mexico City The author has no financial interest in any material or method mentioned

Purpose  The cornea is one of the main refractive structures of the eye and therefore its contribution to the presentation of wavefront aberrations is critical. There is no complete knowledge of the origin of higher-order aberrations. The influence of intraocular pressure (1), corneal thickness (2), eyelid pressure (3), tear film (4), age (5), etc. has been studied. Altered biomechanical parameters in the cornea as a result of refractive surgery can increase ocular image errors. The purpose of this study was to know if in the normal cornea there is a direct correlation between changes in the biomechanical parameters and the presentation of wavefront aberrations.

Methods  The design was an observational series of patients without history of ocular abnormalities. 230 eyes of 115 patients were retrospectively evaluated. The data were taken from files of patients evaluated for refractive surgery. The inclusion criteria were patients of age 18 to 35 years, without clinical signs of keratoconus or other ectatic diseases, no contact lens use, no ocular pathology. The root-mean-square (RMS) wavefront error of the combined coma-like aberrations was measured by an Optical Path Difference Scan II ARK (Nidek Corporation, Hiroishi-Cho, Japan). The Ocular Response Analyzer (Reichert Corporation, Depew, USA) was used to determine the corneal hysteresis (CH). The relationship between higher-order wavefront aberrations and a biomechanical parameter such as corneal hysteresis was statistically analyzed using the Analise-it for Microsoft Excel program (Version 2.07, Analise-it Software, Ltd. Leeds, UK).

Results  Using the Pearson Correlation Coefficient a negative correlation was found between RMS Coma and corneal hysteresis (r = , 2-tailed p < ).

Conclusion  Anterior corneal aberrations vary greatly from patient to patient (6) and little of this is attributable to age, refraction, corneal thickness or intraocular pressure. Changes in higher-order aberrations after refractive or cataract surgery are well known and are believed to be a consequence of variations in factors such as corneal thickness (2) among other causes. Corneal hysteresis is a main biomechanical parameter and it could be considered as playing a role in the origin of wavefront aberrations. However, it was found in this study that in the normal eye there is a negative correlation between RMS coma and corneal hysteresis. The real sources of higher-order aberrations in the normal eye are still unknown (1).

References 1.Qu J, Lu F, Wu JX, Wang QM, Xu CC, Zhou XT, He JC. Wavefront aberration and its association with intraocular pressure and central corneal thickness in myopic eyes. J Cataract Refract Surg 2007; 33: Mierdel P, Krinke HE, Pollack K, Spoerl E. Diurnal fluctuation of Higher order ocular aberrations: Correlation with intraocular pressure and corneal thickness. J Cataract Refract Surg 2004; 20: Lieberman DM, Grierson JW, The lids influence on corneal shape. Cornea 2000; 19: Montés-Micó R, Phil M. Role of the tear film in the optical quality of the human eye. J Cataract Refract Surg 2007; 33: Amano S, Amano Y, Yamagami S, Miyai T, Miyata K, Samejima T, Oshika T. Age-related changes in corneal and ocular higher-order wavefront aberrations. Am J Ophthalmol 2004; 137: Wang L, Dai E, Koch D, Nathoo A. Optical aberrations of the human anterior cornea. J Cataract Refract Surg 2003; 29: Qu J, Lu F, Wu JX, Wang QM, Xu CC, Zhou XT, He JC. Wavefront aberration and its association with intraocular pressure and central corneal thickness in myopic eyes. J Cataract Refract Surg 2007; 33: Mierdel P, Krinke HE, Pollack K, Spoerl E. Diurnal fluctuation of Higher order ocular aberrations: Correlation with intraocular pressure and corneal thickness. J Cataract Refract Surg 2004; 20: Lieberman DM, Grierson JW, The lids influence on corneal shape. Cornea 2000; 19: Montés-Micó R, Phil M. Role of the tear film in the optical quality of the human eye. J Cataract Refract Surg 2007; 33: Amano S, Amano Y, Yamagami S, Miyai T, Miyata K, Samejima T, Oshika T. Age-related changes in corneal and ocular higher-order wavefront aberrations. Am J Ophthalmol 2004; 137: Wang L, Dai E, Koch D, Nathoo A. Optical aberrations of the human anterior cornea. J Cataract Refract Surg 2003; 29: