14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE.

Slides:



Advertisements
Similar presentations
Electromagnetic shower in the AHCAL selection criteria data / MonteCarlo comparison of: handling linearity shower shapes CALICE collaboration meeting may.
Advertisements

2 Introduction   MiniCal test-beam studies started at the beginning of March (till March 6 we only had 17 APD’s, then 33 APD’s)   A few days were.
Digital Filtering Performance in the ATLAS Level-1 Calorimeter Trigger David Hadley on behalf of the ATLAS Collaboration.
Preshower 15/03/2005 P.Kokkas Preshower September Run Data Analysis P. Kokkas.
1 Veto Wall Test Hyupwoo Lee MINERvA/Jupiter Group Meeting June 20, 2007.
Calibration of the 10inch PMT for IceCube Experiment 03UM1106 Kazuhiro Fujimoto A thesis submitted in partial fulfillment of the requirements of the degree.
In order to acquire the full physics potential of the LHC, the ATLAS electromagnetic calorimeter must be able to efficiently identify photons and electrons.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
MEG II 実験液体キセノンガンマ線検出器 における再構成法の開発 Development of the event reconstruction method for MEG II liquid xenon gamma-ray detector 小川真治、 他 MEG II
Trend ground array 1 1.General considerations 2.Study on the prototype detector 3.Inclined ground array simulation 4.Making work plan in 2014.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Coincidence analysis in ANTARES: Potassium-40 and muons  Brief overview of ANTARES experiment  Potassium-40 calibration technique  Adjacent floor coincidences.
IceTop Tank Calibration Abstract This report outlines the preliminary method developed to calibrate IceTop tanks using through going single muon signals.
EHE Search for EHE neutrinos with the IceCube detector Aya Ishihara for the IceCube collaboration Chiba University.
1 S. E. Tzamarias Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Readout Electronics DAQ & Calibration.
Tests with JT0623 & JT0947 at Indiana University Nagoya PMT database test results for JT0623 at 3220V: This tube has somewhat higher than usual gain. 5×10.
Analysis of PSI beam test R.Sawada 09/Feb/2004 MEG collaboration R.Sawada 09/Feb/2004 MEG collaboration
Timing Counter Report of Feb. 14 th, 2007 P.W. Cattaneo.
1 N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Operation and performance of the NESTOR test detector.
Timing Counter Report of Feb 20th, 2008 F.Gatti. Final Construction Phase of TC TC with fibers exposed TC upside down for Fiber APD gluing High reflectance.
1 MEG 陽電子タイミングカウンタの ビーム中での性能評価と 解析方法の研究 * 内山雄祐 東大素粒子セ, INFN-Genova A, INFN-Pavia B 森俊則 F. Gatti. A,S.Dussoni A,G.Boca B,P.W.Cattaneo B, 他 MEG Collaboration.
06 February 2007Fabrizio Cei1 INFN and University of Pisa INFN Scientific Commission I Rome, 06 February 2007 Status of MEG Software.
NA62 Gigatracker Working Group Meeting 23 March 2010 Massimiliano Fiorini CERN.
1 A.Andronic 1, H.Appelshäuser 1, V.Babkin 2, P.Braun-Munzinger 1, S.Chernenko 2, D.Emschernmann 3, C.Garabatos 1, V.Golovatyuk 2, J.Hehner 1, M.Hoppe.
Liquid Xenon Calorimeter Analysis R.Sawada on behalf of the MEG LXe analysis group 17/Feb/2009.
Neutron detection in LHe ( HMI run 2004) R.Golub, E. Korobkina, J. Zou M. Hayden, G. Archibold J. Boissevain, W.S.Wilburn C. Gould.
1 水质契仑科夫探测器中的中子识别 张海兵 清华大学 , 南京 First Study of Neutron Tagging with a Water Cherenkov Detector.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
MEG Run 2008 液体キセノンガンマ線検出器 東京大学 素粒子物理国際研究セン ター 西村 康宏、 他 MEG コラボレー ション 2008 年秋季物理学会@山形大学小白川キャンパス.
CEA DSM Irfu Reconstruction and analysis of ANTARES 5 line data Niccolò Cottini on behalf of the ANTARES Collaboration XX th Rencontres de Blois 21 / 05.
W-DHCAL Analysis Overview José Repond Argonne National Laboratory.
Mar 20, 2005 Iterative pe finder: IceTop data compression applied to In-ice D. Seckel, Univ. of Delaware.
1 NaI calibrationneutron observation NaI calibration and neutron observation during the charge exchange experiment 1.Improving the NaI energy resolution.
Trip-t testing progress report
Test beam preliminary results D. Di Filippo, P. Massarotti, T. Spadaro.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
MEG 実験 背景ガンマ線の研究 澤田 龍 MEG コラボーレーション 東京大学素粒子物理国際研究センター 2010 年 9 月 11 日 日本物理学会 2010 年秋季大会 九州工業大学戸畑キャンパス.
Measurement of the Charge Ratio of Cosmic Muons using CMS Data M. Aldaya, P. García-Abia (CIEMAT-Madrid) On behalf of the CMS Collaboration Sector 10 Sector.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
1 Electronics Status Trigger and DAQ run successfully in RUN2006 for the first time Trigger communication to DRS boards via trigger bus Trigger firmware.
Reconstructing energy from HERD beam test data Zheng QUAN IHEP 3 rd HERD work shop Xi’an, 20 Jan
PMT Calibration R.Sawada 7/Jan/2007. Time calibration Method was talked at the previous meeting. The problems which was shown before were because I used.
Some feedbacks from DRS data analysis (very preliminary) F. Scuri - I.N.F.N Sezione di Pisa RD52 – Collaboration Meeting – Pavia, March 12, 2013 F. Scuri.
CALICE, CERN June 29, 2004J. Zálešák, APDs for tileHCAL1 APDs for tileHCAL MiniCal studies with APDs in e-test beam J. Zálešák, Prague with different preamplifiers.
Comparison of MC and data Abelardo Moralejo Padova.
MEG 実験 2009 液体キセノン検出器の性能 II 西村康宏, 他 MEG コラボレーション 東京大学素粒子物理国際研究セン ター 第 65 回年次大会 岡山大学.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
PMT time offset calibration (not completed) R.Sawada 27/Dec/2007.
Siena, May A.Tonazzo –Performance of ATLAS MDT chambers /1 Performance of BIL tracking chambers for the ATLAS muon spectrometer A.Baroncelli,
A. Tsirigotis Hellenic Open University N eutrino E xtended S ubmarine T elescope with O ceanographic R esearch Reconstruction, Background Rejection Tools.
Seoul National University Han-wool Ju CUNPA Kick-off Meeting Aug.22-23, 2013.
3/06/06 CALOR 06Alexandre Zabi - Imperial College1 CMS ECAL Performance: Test Beam Results Alexandre Zabi on behalf of the CMS ECAL Group CMS ECAL.
1 Methods of PSD energy calibration. 2 Dependence of energy resolution on many factors Constant term is essential only for energy measurement of single.
Feb C.Smith UVA EC energy calibration – g13 pass0 For pass0 data were cooked with CALDB calibration constants reset to nominal 10 channels / MeV.
OD Tuning: SK-IV Roger Wendell TMC Meeting
INFN-Pisa Collaboration Meeting, Roma – 12/10/2013 *
Xiong Zuo IHEP, CAS, for the LHAASO Collaboration
EZDC spectra reconstruction and calibration
Status of Electronics Simulation and Energy Resoluton Estimation
Solving pedestal problem
SuperB LNF meeting March 21st 2012 Marcello Piccolo
Roberto Chierici - CERN
Upgrade of LXe gamma-ray detector in MEG experiment
p0 life time analysis: general method, updates and preliminary result
Upgrade of LXe gamma-ray detector in MEG experiment
Status report Minjung Kim
Timing Counter analysis
Studies of the Time over Threshold
Xiong Zuo IHEP, CAS, for the LHAASO Collaboration
Trigger operation during 2007 run
Presentation transcript:

14/02/2007 Paolo Walter Cattaneo 1 1.Trigger analysis 2.Muon rate 3.Q distribution 4.Baseline 5.Pulse shape 6.Z measurement 7.Att measurement OUTLINE

14/02/2007 Paolo Walter Cattaneo 2 Trigger Data Charge vs Amplitude PMT Key for the Trigger System using pulse height with no information about pulse charge (RUN 236,237,239) Amplitude (a.u.) Charge (a.u.)

14/02/2007 Paolo Walter Cattaneo 3 Charge Inner vs Outer We observe that charge distributions are different between inner and outer PMTs (RUN 236, 237, 239). Charge Inner PMTs Charge Outer PMTs Q (a.u.)

14/02/2007 Paolo Walter Cattaneo 4 Comparison with MC Data DATA MONTECARLO Measured charge distribution for inner PMTs the Montecarlo one are in agreement, as well as the outer ones Q (a.u.)

14/02/2007 Paolo Walter Cattaneo 5 Low energy events on PMT spectrum Bar 16 (first of upstream TC) Outer PMT Bar 19 (fourth of upstream TC) Outer PMT Data Montecarlo Q (a.u.) RUN 236, 237, 239

14/02/2007 Paolo Walter Cattaneo 6 TRG vs DRS height pulse correlation Key for Type3 boards and LXe acquisition, we can see a good linearity until 0.6 mV (0.1 V on DRS  0.4 V on TRG) (RUN 236, 237, 239). (V)

14/02/2007 Paolo Walter Cattaneo 7 We used MC computed acceptance to convert experimental trigger rate to stopped muon rate. Muon rate vs beam intensity MC acceptance including cuts  4.2 % MC acceptance including cuts  3.7 %

14/02/2007 Paolo Walter Cattaneo 8 Bar number 11, run 154 Bar number 6, run 154 Calibrated by superimposing charge peak position of MC events on experimental data Charge distribution (1) Red = Data Black = MC

14/02/2007 Paolo Walter Cattaneo 9 Charge distribution (2) Data wider probably for difficulties of individual software calibration Run 154 Low Intensity Run 236 High Intensity Red = Data Black = MC Charge All bars together

14/02/2007 Paolo Walter Cattaneo 10 Run 154 Low Intensity Red = Data Black = MC Run 236 High Intensity Number of hit bar per event

14/02/2007 Paolo Walter Cattaneo 11 Number of hits on each bar Down stream Up stream Run 154 Low Intensity Run 236 High Intensity 10* KHz KHz

In COBRA, with and without Beam; acquisition with oscilloscope of waveform from PMs with single bar triggering, and evaluation of charge ratio for each pulse, with no selection of impact position; distribution of log(Qin/Qout) for each bar reflects event distribution on each bar; width of the distribution is inversely proportional to attenuation length of bar => clue to the applicability of position reconstruction by means of “charge division” Position reconstruction by means of charge ratio – PSI setup charge distribution on a bar from cosmic rays

waveform analysis - continue Beam turned on: event distribution on 4 US bars most of the events are on the inner part of the detector; needed calibration of each bar to determine impact point. Inner PMTOuter PMT

CAMAC results – position correlations correlation between adjacent bars, distribution of charge ratio on bar 1 for selected impact position on bar 0

CAMAC results – position correlations correlation between adjacent bars: US TC (left) and DS TC(right); curves are fit to the data

14/02/2007 Paolo Walter Cattaneo 16 Baseline & noise analysis 1 Search signal pulse Search pulse in the region Fix regionjust before pulse calculate baselineuse database value no yes low threshold Threshold ? Range ? How stable ? How often ? ● averaging ● did not try fitting

14/02/2007 Paolo Walter Cattaneo 17 Baseline & noise analysis 2: Stability Noise level 0.6 ~ 1mV Baseline fluctuation in a run ~0.3mV Baseline shift  with change of beam intensity  with change of trigger type Baseline is stable among same condition runs  We need baseline value in database each run condition. TC no TC high NaI no TC no TC low NaI low NaI high NaI no NaI high baseline fluctuation Baseline run in database already in database for all run

14/02/2007 Paolo Walter Cattaneo 18 Pulse shape of PMT signal Made one template waveform for all channel. Fitting seem to work well ● Not yet making template for each channel ● Feed back to simulation parameter. Use timing extracted by the fit for following analysis.

14/02/2007 Paolo Walter Cattaneo 19 First Look at Beam data Michel positron from beam, TC trigger  2GHz sampling data, high intensity beam (#79,80,81) ● Trigger related pulses are located 120~150 nsec in DRS window.  Trigger latency ~370 nsec, enough for baseline calculation. ● Pulse height : peak ~60mV, tail with Landau Distribution. about 2.2% pulses are saturated. Pulse Timing Distribution Pulse Height Distribution saturated trigger pulse accidental BG all channels 100ns 200ns

14/02/2007 Paolo Walter Cattaneo 20 Z reconstruction Reconstruct z-position by time difference of both side PMTs Roughly estimate ● Effective light velocity (width) ● Relative time pedestal (center) Preliminary

14/02/2007 Paolo Walter Cattaneo 21 Z position correction Effective velocity ~ 15 cm/ns Time pedestals in database Preliminary

14/02/2007 Paolo Walter Cattaneo 22 Relative gain estimation Using spectra, estimated relative gain. Pulse height after correction by position ● Fit with Landau distribution ● Compare the MPV Preliminary

14/02/2007 Paolo Walter Cattaneo 23 Height ratio If pulse height ratio is mainly determined by attenuation length, ● Roughly extracted effective attenuation length  Att ~ 96 cm Preliminary log(H0/H1) = z*2/Att Due to variety of solid angle