Earthquake Resistant Design Philosophy and Approach in New Zealand Donald Kirkcaldie Earthquake Resistant Design Philosophy and Approach in New Zealand.

Slides:



Advertisements
Similar presentations
During the semester Introductions Basics of earthquakes History and Recording Damaging Earthquakes and Understanding seismic exposure Undertaking loss.
Advertisements

Design of Steel and Composite-Structures for Seismic Loading – Safety Requirements, Concepts and Methods – Prof. Dr.-Ing. Ekkehard Fehling, University.
Design of Seismic-Resistant Steel Building Structures
Actions and Retrofit of Post Earthquake-Damaged Bridges
1 LESSLOSS Sub Project 7 Techniques and Methods for Vulnerability Reduction Barcelona 18 th May 07 – Lisbon 24 th May 07 LESSLOSS Dissemination Meeting.
Seismic Performance Modeling of Reinforced Concrete Bridges
Chp12- Footings.
Bridge Engineering (6) Superstructure – Concrete Bridges
Rigid-Frame Structures
1. 2 World seismic activity British Geological Survey 2.
Performance-based Evaluation of the Seismic Response of Bridges with Foundations Designed to Uplift Marios Panagiotou Assistant Professor, University of.
Bridge Engineering (7) Superstructure – Reinforced Concrete Bridges
2015年5月13日 2015年5月13日 2015年5月13日 Strength and Ductility of Reinforced Concrete Highway Bridge Pier Engr. Md. Abdur Rahman Bhuiyan, PhD Associate Professor.
Seismic design for the wind turbine tower (WP1.5 background document presentation) Institute of Steel Structures Aristotle Univ. of Thessaloniki.
Seismic Performance of Dissipative Devices Martin Williams University of Oxford Japan-Europe Workshop on Seismic Risk Bristol, July 2004.
Bridge Vulnerabilities Oct What puts bridges at risk? Ability to withstand seismic forces and displacements.
Building Systems (Seismic)
POTENTIAL ISSUE TEAM STUDIES CONCRETE CODIFICATION OPPORTUNITIES 1. CONCRETE SHEAR WALLS Current Codes provide detailed provisions for the seismic design.
IRENG07 1 Seismic Consideration Discussion for The Interaction Region Fred Asiri-SLAC.
CEE Capstone II Structural Engineering
During the semester Introductions Basics of earthquakes History and Recording Damaging Earthquakes and Understanding seismic exposure Undertaking loss.
Damage Illustrations. Potential Bridge Damage Bridge Component / DamagePossible Cause Approach Slab or Pavement  Raised, lowered, cracked, or buckled.
FOUNDATION.
COLUMNS. COLUMNS Introduction According to ACI Code 2.1, a structural element with a ratio of height-to least lateral dimension exceeding three used.
December 3-4, 2007Earthquake Readiness Workshop Seismic Design Considerations Mike Sheehan.
Villanova University Dept. of Civil & Environmental Engineering CEE 8414 – Structural Dynamics Northridge Earthquake 1 Northridge Earthquake - Concrete.
SHEAR IN BEAMS. SHEAR IN BEAMS Introduction Loads applied to beams produce bending moments, shearing forces, as shown, and in some cases torques. Beams.
GW Rodgers, C Denmead, N Leach, JG Chase & John B Mander
Static Pushover Analysis
Reinforced Concrete Design
MAE CENTER RESEARCH SUCCESS WITH DOTs Past and Future Neil M. Hawkins - Professor Emeritus University of Illinois MAE Center Annual Meeting With.
TOPICS COVERED Building Configuration Response of Concrete Buildings
FOOTINGS. FOOTINGS Introduction Footings are structural elements that transmit column or wall loads to the underlying soil below the structure. Footings.
Seismic Retrofitting of Bridges Donald Kirkcaldie Seismic Retrofitting of Bridges Donald Kirkcaldie.
LIQUEFACTION FAILURE OF FOUNDATION - STRUCTURE COLLAPSE.
1. 2 CE-312 Engineering Geology and Seismology Instructor: Dr Amjad Naseer Lecture#15 Department of Civil Engineering N-W.F.P University of Engineering.
University of Palestine
1 NEESR Project Meeting 22/02/2008 Modeling of Bridge Piers with Shear-Flexural Interaction and Bridge System Response Prof. Jian Zhang Shi-Yu Xu Prof.
Building Fun You will have 30 minutes to build the strongest structures you can with only the materials you are provided with. Explain to the class the.
Mechanical Design of Process Equipment FUNDAMENTAL PRINCIPLES AND EQUATIONS Principal stresses Theories of failure
Presented by: Sasithorn THAMMARAK (st109957)
Overview of the “Recommended LRFD Seismic Design Specifications for Highway Bridges” Ian M. Friedland, P.E. Bridge Technology Engineer Federal Highway.
Earthquake Resistant Building designs. Buildings are designed to withstand vertical forces. Buildings are designed to withstand vertical forces. If earthquakes.
This work is supported by the National Science Foundation’s Transforming Undergraduate Education in STEM program within the Directorate for Education and.
BASICS OF DYNAMICS AND ASEISMIC DESIGN
Practical Design of PT Buildings
UNIT 5 BRICK MASONRY.
Vulnerable Structural Elements
Building Construction
Earthquake Engineering
ACI Committee 341-C State-of-the-Art Summary Seismic Evaluation and Retrofit Techniques for Concrete Bridges.
Base Isolation. Conventional Construction Practice assumes Fixed Base Structures The Dynamic Characteristics of Fixed Base Structures are determined by.
A SAMPLING OF BRIDGE PERFORMANCE CRITERIA BY MARK YASHINSKY, CALTRANS OFFICE OF EARTHQUAKE ENGINEERING Most bridge owners have adopted design criteria.
Review of Indian Seismic Codes
Divisional Engineer/East/Ranchi South Eastern Railway
Seismic analysis of Bridges Part II
Seismic Waves Large strain energy released during an earthquake
Eduardo Ismael Hernández UPAEP University, MEXICO
Limit state design (LSD) refers to a design method for RCC Structures
Seismic Design Impact to
CFHT Pier Building Evaluation
Prepared by John R. Henry, P.E. Senior Staff Engineer
BRIDGES MOST IMPORTANT GEOTECHNICAL EFFECT- LIQUEFACTION
“Base isolation and Seismic Consideration in Civil Engineering”..
Arch205 Materials and building construction 1 foundation
ASSESSEMENT AND REHABILITATION OF STRUCTURES
Arch205 building construction foundation
Earthquake resistant buildings
Masonry Bearing Walls.
Post Seismic Bridge Inspection
Presentation transcript:

Earthquake Resistant Design Philosophy and Approach in New Zealand Donald Kirkcaldie Earthquake Resistant Design Philosophy and Approach in New Zealand Donald Kirkcaldie

1 The Development of Earthquake Resistant Design 1931 Napier Earthquake – Design lateral loading of 0.1g introduced 1964 Anchorage and Niigata Earthquakes – major damage to infrastructure due to soil liquefaction 1971 San Fernando Earthquake in California: Serious damage to major highway structures Provided the impetus for a concerted international research effort Led to the initiation of NZ’s seismic design philosophy and approach – MWD Highway Bridge Design Brief published, with updates in 1972, 1973, and 1978.

2 New Zealand’s Seismicity NZ’s seismicity Comparable to California, and areas adjacent to the Himalayan system, e.g. Burma, Bangladesh Major earthquakes in recent times have included: 1855 Wairarapa - ~8.1 magnitude Since 1885: ~ magnitude & – 6.9 magnitude I.e. > two major events every ~10 years Seismicity varies throughout the country as shown in the next slide

3 New Zealand Seismicity Zonation

4 New Zealand’s Earthquake Resistance Philosophy Forces imposed on bridge piers can exceed 1g for the more rigid structures, scaling down to ~0.2 g for more flexible structures, if the bridges remain elastic. Costly and seldom economically justifiable Build energy absorbing capability into the structure and use this to reduce the earthquake forces to be resisted. Energy absorption provided through ductile inelastic action, focused to occur only in members specifically detailed for the purpose.

5 Traditional Performance Principles (a) After a design return period event: Damage may have occurred and temporary repairs may be required Bridge is to be useable by emergency traffic Bridge is to be able to be reinstated to full capacity for traffic and seismic loads (b) After an event of return period significantly less than the design value: Damage should be minor No disruption to traffic (c) After an event of return period significantly greater than the design value The bridge should not collapse The bridge should be useable by emergency traffic after temporary repair Repair should be feasible, albeit to a lower level of load capacity

6 Traditional Performance Principles The design earthquake adopted intensity is a function of the importance and design life of the structure. A bridge is categorised for its structural action under horizontal seismic load. Maximum ductility factors are assigned based on the manner in which and extent to which plastic mechanisms can form and their accessibility for repair. (See next slide)

7 Categorisation of Structures – Maximum Ductility Factor µ

8 Traditional Performance Principles In practice, design is only carried out for (a) Bridges well designed for (a) are expected to also satisfy (c) due to: Greater actual member strength Greater damping due to more of the response being inelastic Reduced structural stiffness due to softening of the structure Greater structure displacement ductility capability

9 Updated Required Bridge Performance Levels NZTA Bridge Manual has traditionally aligned with the NZ Loading Code NZS :2006 has introduced explicit consideration of SLS requirements in addition to the ULS. Corresponding draft amendments have been prepared for the Bridge Manual as follows:

10 Draft Revised Bridge Performamce Requirements SLS1 (100 year return period*) No damage to structural or non-structural components SLS2 (500 year return period*) No more than minor damage to primary structural members Damage to secondary or non-structural components shall not significantly impede the operational functionality of the bridge ULS (2500 year return period*) Structural stability is maintained Access available for emergency vehicles after temporary repairs Damage may be extensive, but structure should be repairable to full capacity * Return periods are those applying to most state highway bridges

11 Implementation - Overview Earthquake resistant design is more an art than a science The designer needs to develop an understanding of the likely structural behaviour Choices may be necessary in order to optimise the structural form Analysis is only a guide to likely behaviour, not an accurate representation. Some significant assumptions are involved Robust detailing is required to cater for the unexpected and the possibility of larger than design events

12 Implementation – Site Assessment Site assessment Categorisation of the site subsoil Proximity of active faults Need for a site specific hazard study (- active fault proximity, bridge of high value) Development of site hazard spectra Selection of appropriate earthquake records if time- history analysis is to be undertaken Site stability (- mass ground movement, potential for soil liquefaction)

13 Implementation – Choice of Structural Form Considerations in the choice of structural form include: Bridge form (simply supported v continuous superstructure, support on bearings v build superstructure integral with substructure, etc.) Materials to be used, the structure’s flexibility, and ductility attainable with a particular configuration The number and location of supports used to resist seismic forces, and relative distribution of mass and stiffness within the structure The balance between displacement and strength requirements. Flexibility decrease the seismic response accelerations but increases the movement at joints, and their cost.

14 Implementation – Choice of Structural Form (contd.) Considerations in the choice of structural form include (contd.): The number, location and form of energy dissipation points. Are they to be plastic hinges in structural members or energy dissipation devices, and their accessibility for repair. The number location and function of movement joints Maintenance of structural integrity and prevention of collapse of spans off supports The bridge response to EQ in all directions

15 Implementation - Analysis Selection of the analysis method should take into account: The complexity of the structural form The nature of the anticipated response to ground motions The degree of inelastic behaviour Three forms of analysis are available: Equivalent static force analysis Elastic modal spectral analysis Inelastic dynamic analysis by numerical integration Analytical results only provide an indication of a structure’s likely behaviour. The structure must be capable of surviving deformations exceeding what analysis might predict

16 Implementation – Capacity Design Capacity Design entails the following: The predetermination of locations in the structure at which plastic yielding will be designed to occur. The design of those plastically yielding locations for yielding to initiate at an acceptable intensity of earthquake ground motion The detailing of those plastically yielding locations to maintain their ability to yield in a controlled ductile manner throughout the response Other structural elements, intended not to yield, are detailed with sufficient reserve strength to remain elastic and so as to maintain their integrity

17 Implementation - Detailing Appropriate and robust detailing is required to ensure: That energy dissipation throughout the yielding of elements can occur The integrity of the structure will be maintained during response to earthquakes of greater than design intensity and to effects not predicted by the analysis In particular, that the collapse of spans is avoided No significant damage or loss of serviceability is incurred during earthquakes of SLS design intensity.

18 Implementation - Detailing Some critical areas of detailing to note include: Plastic hinge zones: No lapping of primary flexural reinforcement in these zones Increased confinement to prevent bar buckling Increased shear reinforcement, due to reduced contribution from the concrete Design of Non –Yielding Elements These must withstand the forces induced by yielding elements developing their “overstrength” capacity Prevention of span collapses Linkage of spans to supports and to each other Adequate overlap of girders with supports

19 Implementation – Detailing (contd.) Some critical areas of detailing to note include (contd.): Freedom to Displace The structure must have the freedom to displace to develop the design ductility Knock-off elements at the abutments and maybe elsewhere, (unless designed as locked-in or with integral abutments) Deck Joints and Bearings Ability to accommodate the SLS seismic movements Security of bearings against being displaced

20 Detailing Examples Plastic hinge accessible for inspection Resisting elements designed for PH overstrength Reinforcement laps positions Column & pile confinement Joint shear reinforcement Bar terminations Pier top rotational inertia effects

21 Detailing Examples Tight and loose linkage of spans to supports Span – support overlap EQ ULS & SLS movement & knock-off device Settlement slabs behind abutments

22 Detailing Examples Linkage to a pier Deck slab diaphragm action

23 Base Isolation with Mechanical Energy Dissipation Base isolation with mechanical energy dissipation is a special case of the ductile capacity design approach The bridge superstructure is isolated from the worst effects of the ground motion by means of flexible mounting, usually elastomeric bearings. The effect is to increase the period of response of the structure into a period range of the response spectrum where the earthquake shaking is less intense Increased equivalent structural damping is achieved through the use of special devices which rely on the cyclic yielding of steel or lead components

24 Base Isolation with Mechanical Energy Dissipation

25 Base Isolation with Mechanical Energy Dissipation Base isolation with mechanical energy dissipation has been found to be most effective in situations where: The seismicity is high The substructures are stiff or are required to remain elastic Note however, that foundation flexibility increases the section ductility demand on any form of plastically yielding element

26 Base Isolation with Mechanical Energy Dissipation Potential advantages of base isolation with mechanical energy dissipation lie in: Reduced displacements compared to structures with elastomeric bearings only – enabling simpler deck joint details Favourable reduction in the level of seismic forces imposed on the structure Redistribution of seismic forces on the substructure and foundations Enabling the use of non-yielding structural forms or components intended to remain elastic in the substructure Greater control over earthquake induced damage – Under design intensity earthquakes structural damage should be completely avoided.

27 Conclusion Earthquake resistant design is not an exact science. Skilled judgement based on experience is a vital ingredient Experience has shown that by using the ductile capacity design approach, bridges can be economically constructed to resist severe earthquakes The philosophy and approach is equally applicable to areas of significant but lesser seismicity than NZ In any area of potential seismic activity, it is essential lifeline bridges be of appropriate form, well tied together longitudinally, and detailed to ensure tolerance to seismic overload and unexpected effects