Status of the COBRA Magnet Wataru OOTANI MEG review meeting Feb. 3, 2003 PSI Switzerland.

Slides:



Advertisements
Similar presentations
Magnetic fields R&D update B. PlasternEDM November 2007 Collaboration Meeting Results from prototype studies of a 1/6-scale B 0 coil with Results from.
Advertisements

HL-LHC Corrector Magnet 3D design status Giovanni Volpini on behalf of the LASA team CERN, February 25, 2014.
Zian Zhu Superconducting Solenoid Magnet BESIII Workshop Zian Zhu Beijing, Oct.13,2001.
P.-R. KettleMEG-Review February MEG Beam Line Studies  E5 Z-Branch NOW !!! NOW !!!
SCU Measurements at LBNL
CM-18 June The Measurement and Monitoring of the Field from the MICE Magnets Michael A Green Lawrence Berkeley Laboratory, Berkeley, USA Frank Filthaut.
Cryostat and Magnet Status Report UIUC EDM Collaboration Meeting LANL June 20, 2005.
Guenther Rosner FAIR Design Study, PANDA 3, GSI, 19/1/06 1 PANDA3: Magnet design and integration of detectors Tasks & participants Progress Milestones.
Guenther Rosner DIRACmidterm, GSI Darmstadt, 8/12/06 1 Task 4  PANDA 3 Magnet design and integration of detectors Milestones Status Outlook.
Cutnell/Johnson Physics 8th edition Reading Quiz Questions
Spectrometer Solenoid Design and Procurement Review Steve Virostek Mike Green Mike Zisman Lawrence Berkeley National Lab MICE Collaboration Meeting October.
Zachary Wolf Undulator Tuning June 17, 2008 Undulator Tuning Status Z. Wolf, S. Anderson, R. Colon, S. Jansson, S.Kaplunenko,
Global Magnet Systems including Field Mapping MICE Project Board 28 th June 2011 M Courthold – RAL R Preece - RAL.
1 Xenon Detector Xenon Detector Group. 2/22 Contents  Construction Status Cryostat PMT mounts  PMT Pisa PMT test PSI PMT test Trouble report  Neutron.
Status report about the e-  identifier Study of shielding against the stray magnetic field at the downstream end of the spectrometer F. Huveneers, Gh.
Magnetic Diagnostics for GLAST-III Tokamak M. A. Naveed, Aqib javeed and GLAST Team National Tokamak Fusion Programme Islamabad Pakistan IAEA First Technical.
Solenoid Magnetic Field Mapping Paul S Miyagawa University of Manchester Objectives Mapper machine Mapper software Simulation Corrections Fitting Future.
Solenoid Magnetic Field Mapping Paul S Miyagawa University of Manchester Introduction Mapper machine Mapper software - Simulation - Corrections - Fitting.
Coil Manufacture, Assembly and Magnetic Calibration Facility for Warm and Cold Magnetic Measurements of LHC Superconducting Magnets CERN AT-MTM 1 / 21.
Global Design Effort Detector concept Plenary introductory talk IRENG07 Kurt Krempetz September 17, 2007.
COBRA Magnet Test Milestone AssemblyDesignManufactoring DesignAss.TestWinding & Cryo. Deliv. PSI Test Platform Calibration Mapping device.
Update on Cryotarget System Jian-ping Chen GMn Collaboration Meeting, Feb. 24, 2014  Overview  Maintenance/Modifications During Down  Installation Status.
Malte HildebrandtMEG Review Meeting, 14th February 2007 Report of Run Coordinator Run 2006 Summary Malte Hildebrandt MEG Review Meeting, 14th February.
3 March 2009M. Breidenbach1 SiD LoI Costs M. Breidenbach.
Status of CEPC Detector magnet
Status of COBRA Magnet Wataru OOTANI MEG review meeting July 11 th, 2003 PSI Switzerland.
MICE CM32 8 th February 2012 Magnet Group Report Vicky Bayliss Victoria Blackmore John Cobb Mike Courthold Roy Preece Mike Zisman 1.
ATLAS Inner Detector Magnetic Field I am responsible for providing the magnetic field map for the ATLAS Inner Detector.  6m long x 2m diameter cylindrical.
Magnetic Field A magnetic field is a region in which a body with magnetic properties experiences a force.
1 W.Ootani ICEPP, University of Tokyo MEG experiment review meeting Feb , PSI W.Ootani ICEPP, University of Tokyo MEG experiment review meeting.
Detector studies, Radiation Simulations, Organization FCC Hadron Detector Meeting July 27 th 2015 W. Riegler.
Some Thoughts on Magnetic Measurements for MICE Michael A. Green Lawrence Berkeley Laboratory Berkeley CA 94720, USA.
Forum March 2003H.Taureg1 Magnetic Fields in ALICE Mapping and Monitoring.
Magnet Measurement Device for MICE F. Garnier, P-A. Giudici, F.Bergsma CERN MICE Collaboration Meeting No. 29 RAL technical drawings by O.Jamet.
KEK Hiroshi Yamaoka Task list for Magnet/Iron yoke Solenoid magnet Iron yoke Experimental hall and other facilities May 11, ’05.
COBRA Magnet Status W. Ootani June 27th, 2006 MEG Review W. Ootani June 27th, 2006 MEG Review.
CEA DSM Irfu - F. KIRCHER - [Seoul Workshop, Feb 16-18, 2009] 1 ILD detector magnet: LoI version F. Kircher, O. Delferrière CEA Saclay, DSM/Irfu/SACM.
ILD Magnet & calorimeters integration meeting Questions to be addressed 01-02
1 Chapter 19: Magnetism The nature of magnetism Iron ore found near Magnesia Compass needles align N-S: magnetic Poles North (South) Poles attracted to.
UK Update Package Managers Meeting 001 Roy Preece 13 th January 2014.
MICE Coupling Coil Testing at Fermilab All Experimenters Meeting Ruben Carcagno March 19, R. Carcagno - MICE CC Testing at Fermilab3/19/2012.
3.The residual B r on the cylindrical surface is represented by multipole terms The results from the combined geometrical + general Maxwell fit show that.
X LCLS SCU NbTi Prototype Schedule Version: February 12, 2015 Update 23JUN2015 X X System complete and ready for test X System complete & tested w/Hall.
3.The residual B r on the cylindrical surface is represented by multipole terms The results from the combined geometrical + general Maxwell fit show that.
1. Introduction 2. Magnetic field design Optimization of yoke configuration in several conf. Boundary conditions -
1 COBRA Magnet Status W.Ootani MEG Experiment Review Meeting, Jul W.Ootani MEG Experiment Review Meeting, Jul
Mapping the Magnetic Field of the ATLAS Solenoid Paul S Miyagawa University of Manchester ATLAS experiment + solenoid Objectives Field mapping machine.
NUMI Update on Steel, Coils, Fixtures, and Prototyping J.K. Nelson 12/98 MINOS Meeting.
Xenon Delivery Japan 1 MCHF 575 kCHF granted Additional grant 656 kCHF Last 50l subject to negotiation.
Phobos Magnet Status Leslie Rosenberg & Patrick Decowski, MIT Technical Advisory Committee November 1998.
A. Baldini PSI July 05 Overview of the experiment MEG is being built (Beam line, Magnet, LXe, DC, TC, Elect., Software) Delays in some items: O(months)
1 W.Ootani ICEPP, University of Tokyo MEG experiment review meeting Feb , PSI W.Ootani ICEPP, University of Tokyo MEG experiment review meeting.
Physics requirements  mapping spec’s Strategy: analyze measurements to get field Mapping plan: where/how to map Engineering design: sensor, fixtures,
 ENROLLMENT NO  NAME. KARAN SHARMA MAGNETIC FIELD.
Physics Requirements Sensitivity to Manufacturing Imperfections Strategy  where to map field  measure deviation from ideal model  fit to error tables.
Status of physics analysis Fabrizio Cei On Behalf of the Physics Analysis Group PSI BVR presentation, February 9, /02/2015Fabrizio Cei1.
CERN –GSI/CEA MM preparation meeting, Magnetic Measurements WP.
Starter What effect does an iron core have on the magnetic field of a coil? ( What role does the nail play?) What effect does an iron core have on the.
F. Kircher CLIC concept meeting 12/15/08 1 Some points about the superconducting magnet for a CLIC detector F. Kircher (CEA Saclay/DSM/Irfu/SACM) December.
g beam test of the Liquid Xe calorimeter for the MEG experiment
Yingshun Zhu Accelerator Center, Magnet Group
Yingshun Zhu Design progress of QD0 in CEPC Interaction Region
Why do we need to know the fields / map the magnets?
The CMS magnet superconducting coil
Conceptual Design of CEPC Interaction Region Superconducting Magnets
Yingshun Zhu Accelerator Center, Magnet Group
PHYS 1444 – Section 003 Lecture #21
Electromagnetic Forces and Fields
L H C A T L A S International Collaboration on the LHC Project
MEG Summary T. Mori for MEG Collaboration February 9, 2005.
Presentation transcript:

Status of the COBRA Magnet Wataru OOTANI MEG review meeting Feb. 3, 2003 PSI Switzerland

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Status of the Construction Main superconducting magnet Main superconducting magnet  An excitation test of the central part of the magnet was successfully done. successfully done. The mechanical strength and superconducting performance were measured.  good performance!  A serious problem was found in one of the end coils.  We decided to wind another end coil.  Power supply is complete.  Cryostat is being assembled. Compensation coil Compensation coilComplete. Field measurement Field measurement Design work of the mapping machine is in progress.

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Construction Schedule The schedule is delayed by a few months due to the problem in the end coil.  early Feb. ‘03 Conductor for re-winding of the end coil will be delivered. will be delivered.  mid-Feb. Winding completed.  mid-Mar. Installation of the coils into the cryostat.  late Mar. SCM completed.  early Apr. Assembly of SCM and NCM completed  early May Total test of the magnet  early June Shipped to PSI

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Field Mapping Design work of the mapping machine is in progress. It can scan throughout inside the magnet. It can scan throughout inside the magnet. Point-by-point precision of the field map ~ 10Gauss Point-by-point precision of the field map ~ 10Gauss Position accuracy ~ a few hundred  m Position accuracy ~ a few hundred  m Ultrasonic motor with a rotary encoder (4000pulses/rotation) Ultrasonic motor with a rotary encoder (4000pulses/rotation) for R- and Z-motion and high-torque AC servo-motor for  -motion for R- and Z-motion and high-torque AC servo-motor for  -motion Timing belt will be used for the motion in all directions Timing belt will be used for the motion in all directions Absolute calibration of the probe position by an optical scale sensor Absolute calibration of the probe position by an optical scale sensor  already tested in 1Tesla magnetic field.  already tested in 1Tesla magnetic field.

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Fringe Field of the COBRA Magnet 1G 10G Fringe field <10Gauss outside  E5 area

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Fringe Field of the COBRA Magnet, cont ’ d ~10Gauss at 5-7m ~1 Gauss at 12-15m

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Effect of the Fringe Field on Other Detector Components 50G 115G 265G 608G 1.4kG 3.2kG 7.4kG Magnetic field olerance of the items to be used Magnetic field olerance of the items to be used in the detector is being investigated. in the detector is being investigated. Refrigerators(magnet & calorimeter) OK Refrigerators(magnet & calorimeter) OK Temperature sensor(PT100) OK Temperature sensor(PT100) OK Pressure sensor Pressure sensor Pump Pump Locations of the items should be determined Locations of the items should be determined according to their tolerance to the magnetic according to their tolerance to the magnetic field. field. The region with low flux density The region with low flux density near the calorimeter (R=65-100cm, |Z|<50cm) near the calorimeter (R=65-100cm, |Z|<50cm) >5m apart from the magnet. >5m apart from the magnet.

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Ambient Magnetic Field in the Experimental Hall The ambient magnetic field in the PSI West area was already The ambient magnetic field in the PSI West area was already measured by UCN group. measured by UCN group. The measurements were made at several locations The measurements were made at several locations in the experimental hall. in the experimental hall. (not measured at  E5 area) (not measured at  E5 area) They identified different kinds of magnetic noise sources. They identified different kinds of magnetic noise sources. ALC magnet at  E3, GPS magnet, SULTAN, ALC magnet at  E3, GPS magnet, SULTAN, moving vehicles(cars, PSI trucks, lorries), … moving vehicles(cars, PSI trucks, lorries), … At all of the locations At all of the locations average < 100  T average < 100  T rms < 100nT rms < 100nT The effect of the ambient magnetic noise seems to be negligible. The effect of the ambient magnetic noise seems to be negligible.

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Effect of Magnetic Materials Magnetic materials inside the solenoid Magnetic materials inside the solenoid  We have to avoid using ferromagnetic materials in the inner detectors.  We are starting to list possible magnetic materials inevitably used inside the solenoid. Nickel coating on the connectors, Kovar alloy used in the PMT, etc. Magnetic materials outside the solenoid Magnetic materials outside the solenoid  We have to care about… effect on the magnetic field around the photon detector effect on the magnetic field around the photon detector Requirement: B // < 50G B perpendicular <150G for a proper operation Requirement: B // < 50G B perpendicular <150G for a proper operation of the PMTs. of the PMTs. effect on the magnetic field inside the solenoid effect on the magnetic field inside the solenoid Requirement: fluctuation < 0.1%

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Effect on the Residual Field around the Photon Detector d Fe LXe coil 1m Fe A 1.5m B C Effect of the magnetic material was calculated placing an iron block at position A, B or C. At the position B and C, the effect is not so serious.  B ~ 10 Gauss around the photon detector At the position A, the effect is serious if d<1m.

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Effect on the Field around the Photon Detector, cont ’ d LXe Monitoring path Position A d=0.3md=0.5m d=1.0m d=1.5m

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Effect on the Field inside the Solenoid d Fe LXe coil 1m Fe A 1.5m B C Effect of the magnetic material was calculated placing an iron block at position A, B, or C. At the position B and C, the effect is negligible.  B/B < 0.01% in the central tracking region. At the position A, the effect is negligible if d>1.5m.

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Effect on the Field inside the Solenoid, cont ’ d Monitoring region Z X d=0.3md=0.5m d=1.5m Position A Position C  B/B X[m] Z[m]

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Effect of the Transport Solenoid Influence of the muon transport magnet (30cm  x 400cm Bc=0.2T) (30cm  x 400cm Bc=0.2T) Fringe field from the transport magnet Fringe field from the transport magnet < 10 Gauss in the calorimeter region < 10 Gauss in the calorimeter region Positron tracking Positron tracking Negligible effect Negligible effect EM interaction between MEG magnet and muon transport magnet EM interaction between MEG magnet and muon transport magnet OK OK

Wataru Ootani, Feb. 3 rd 2003, MEG review meeting, PSI Summary Construction of the magnet is in progress. Construction is behind the schedule by a few months due to a serious problem found in the end coil. Fringe field of the magnet <10G outside the  E5 area Ambient magnetic noise in the area is negligible. Effect of the magnetic material was studied. Avoid using massive iron within 1.5m along the magnet axis. The effect of the magnetic material near the calorimeter is not so serious although the effect should be carefully evaluated in advance.