Introduction Silicon Photomultipliers (SiPMs) are well recognized due to exceptional photon number and timing resolution. However, due to specific SiPM.

Slides:



Advertisements
Similar presentations
New developments of Silicon Photomultipliers (for PET systems)
Advertisements

Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Microscope Performance at elevated dark rates Richard Jones University of Connecticut collaboration GlueX collaboration meeting, Newport News, Feb. 2-4,
Novel approach for calibration breakdown voltage of large area SiPM
External calibration system - QMB6 Distribution of light: Notched Fiber Calibration and Monitoring Board (CMB) 1-ch LED driver (QMB1) Calibration System.
Photon detection Visible or near-visible wavelengths
Test of Silicon Photomultipliers (SiPM) at Liquid Nitrogen Temperature Yura Efremenko, Vince Cianciolo nEDM CalTech Meeting 02/14/2007.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
H.-G. Moser Max-Planck-Institut for Physics, Munich CALOR 06 Chicago June 5-9, 2006 Silicon Photomultiplier, a new device for low light level photon detection.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
Calibration UV LED system for CALICE scintillator based Tile Hadron Calorimeter Ivo Polák on behalf of the CALICE Collaboration Institute of Physics of.
Salvatore Tudisco The new generation of SPAD Single Photon Avalanche Diodes arrays I Workshop on Photon Detection - Perugia 2007 LNS LNS.
SiPM: Development and Applications
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
9 September 2009 Beam Loss Monitoring with Optical Fibers for Particle Accelerators Joint QUASAR and THz Group Workshop.
Beam Loss Monitoring – Detectors Photon Detection and Silicon Photomultiplier Technology in accelerator and particle physics Sergey Vinogradov QUASAR.
Sergey Vinogradov3rd oPAC Topical workshop on Beam diagnosticsVienna 8 May Silicon Photomultipliers for accelerator and medical applications Dr.
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group May 29 – Jun 4 DESY Introduction.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
Simonetta Gentile, LCWS10, March 2010, Beijing,China. G-APD Photon detection efficiency Simonetta Gentile 1 F.Meddi 1 E.Kuznetsova 2 [1]Università.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
Timing Studies of Hamamatsu MPPCs and MEPhI SiPM Samples Bob Wagner, Gary Drake, Patrick DeLurgio Argonne National Laboratory Qingguo Xie Department of.
28 June 2007G. Pauletta: ALCPG Tests of IRST SiPMs G. Pauletta Univ. & I.N.F.N. Udine Outline 1.IRST SiPMs : baseline characteristics 2.first application.
CALICE Tungsten HCAL Prototype status Erika Garutti Wolfgang Klempt Erik van der Kraaij CERN LCD International Workshop on Linear Colliders 2010, October.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
Basic Detector Measurements: Photon Transfer Curve, Read Noise, Dark Current, Intrapixel Capacitance, Nonlinearity, Reference Pixels MR – May 19, 2014.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
The VSiPMT: A new Generation of Photons Detectors G. Barbarino 1,2, F. C. T. Barbato 1,2, R. de Asmundis 2, G. De Rosa 1,2, F. Di Capua 1, P. Migliozzi.
Fibre Beam Loss Monitoring system development BI - day 10 March 2016 M. Kastriotou, E. Nebot del Busto M. Boland, F. S. Domingues Sousa, E. Effinger, E.B.
Beam Loss Monitor activities at CTF3 and the Australian Synchrotron CLIC Workshop 18 January 2015 M. Kastriotou, E. Nebot del Busto M. Boland, E.B. Holzer,
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Topic Report Photodetector and CCD
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Fondazione Bruno Kessler Centre for Materials and Microsystems.
D. Renker, PSI G-APD Workshop GSI, PAUL SCHERRER INSTITUT Problems in the Development of Geiger- mode Avalanche Photodiodes Dieter Renker Paul Scherrer.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
1 Topic Report Photodetector and CCD Tuan-Shu Ho.
Development of Multi-Pixel Photon Counters (1)
The PSD at Pb-Pb run PSD drawbacks at Ar beam
Performance of LYSO and CeBr3 crystals readout by SiPM
Progress report on SiPM development and its applications
NUV-SiPM short technology description
From: A fast high-voltage switching multiwire proportional chamber
Evidence for direct detection of ionizing particles in SiPMs
Frontier Detectors for Frontier Physics
FINAL YEAR PROJECT 4SSCZ
EUDET JRA3, Activity Obninsk State University
Welcome !! to oPAC Workshop on BLMs Carsten P. Welsch
Optical Crosstalk in SiPM
G. Tamulaitis, A. Augulis, V. Gulbinas, S. Nargelas, E. Songaila, A
After-pulsing and cross-talk comparison for PM1125NS-SB0 (KETEK), S C (HAMAMATSU) and S CS (HAMAMATSU). Oleynikov V.P.*, Porosev V.V.
Reward-renewal model of SiPM response to arbitrary waveform optical signals of beam loss monitoring systems S. Vinogradov, L. Devlin, E. Nebot del Busto,
Upgrade of LXe gamma-ray detector in MEG experiment
Instrumentation for Colliding Beam Physics 2017
A near–quantum-limited Josephson traveling-wave parametric amplifier
md-NUV PET project meeting
T2Kロシアグループに向けたMPPC(SiPM)の性能評価
CLAS 12 Status of the test bench Calculation of the time resolution
The MPPC Study for the GLD Calorimeter Readout
Gain measurements of Chromium GEM foils
Hamamatsu’s SiPM (MPPC) Characteristics and Latest Developments
Presentation transcript:

Introduction Silicon Photomultipliers (SiPMs) are well recognized due to exceptional photon number and timing resolution. However, due to specific SiPM drawbacks such as high dark and correlated noises (crosstalk, afterpulsing), and nonlinearity (limited number of pixels, relatively slow pixel recovery time) their applications are mostly associated with detection of weak light pulses of nanosecond time scale [1, 2]. In contrast with the typical scintillation and Cherenkov detection - photon number and time resolving applications - accelerator Beam Loss Monitoring (BLM) systems with Cherenkov fibre readout have to precisely reconstruct the temporal profile of the light pulse. This is a rather challenging task for any photon detector because of the high dynamic range (~10 6 ) from a few photons to a few percent of destructive losses and presumably an arbitrary signal waveforms i.e. localisation of losses (Fig. 1) [3, 4]. This study, in advance of an initial approach [5], is focused on the consideration of a transient SiPM response as a reward-renewal Markov process formed by non- homogeneous Poisson process of photon arrivals and exponential pixel recovery process conditional on previous firing of the pixel. Challenges of intense light signal detection due to SiPM nonlinearity Nonlinearity of a photodetector response inevitably degrades its resolution (Fig. 2 a). SiPM nonlinearities are associated with losses of photons due to limited number of pixels and non-instant pixel recovery (dead time) [2] (Fig. 2 b). Moreover, incomplete recovering of pixels during detection of long light pulses results in a distortion of the probability distribution of Gain to lower mean values of Gain and to higher excess noise (Fig. 2 c). Reward-renewal model of transient SiPM response Renewal process is considered as a Poisson process of photon arrivals with exponential distribution of inter-arrival times and Bernoulli detection process with exponential recovering of probability to detect the next photon (Fig. 3 a). Reward process is considered as a process of multiplication with a random gain when the gain depends on time lapsed from the previous firing of the same pixel t with respect to recovery time τ rec (Fig. 3 a). Renewal equation and mean reward rate are evaluated accordingly known reward- renewal theory and its applications, and the analytical results are shown on Fig. 3 b.: Experimental studies of transient SiPM response Experiments have been carried out with rectangular pulses (8 ns rise & fall times) of a 440 nm LED with variable intensity, repetition rate, and pulse width (Fig. 4). SiPM response has been read out without a preamplifier at a 50 Ohm input to avoid any possible saturation at high output signal level in analog bandwidth from DC to 1 GHz. Single electron response was measured with a 20 dB, 4 GHz external amplifier Mini- Circuits ZX E+. Hamamatsu MPPC S C of 50 μm cell size 3x3 mm 2 area was used as a well known and very popular SiPM representative. Conclusion The transient SiPM response reveals a rather complex dynamic behavior with a strong dependence on the mean number of detected photons per pixel per recovery time. Reward-renewal Markov process model has been applied to SiPM response analysis for the first time and promising analytical results have been obtained. In the case of a rectangular light pulse detection the model allows to get an analytical expression for the mean SiPM response as a result of renewal process with a mean detection rate and reward process with a mean gain affected by incomplete recovering of pixels, which are in agreement with analytical and experimental results [5]. Acknowledgments This work has been supported in part by the EC under Grant Agreement “SiPM in-depth” and the STFC Cockcroft Institute Core Grant No ST/G008248/1. References [1] P. Buzhan et al., Silicon photomultiplier and its possible applications, NIMA 504, 48–52, [2] S. Vinogradov et al., “Efficiency of Solid State Photomultipliers in Photon Number Resolution,” IEEE TNS 58, 9–16, [3] D. Di Giovenale, L. Catani, and L. Frohlich, “A read-out system for online monitoring of intensity and position of beam losses in electron linacs,” NIMA 665, 33–39, [4] L.J. Devlin, C.P. Welsch, E.N. delBusto, 'Update on Beam Loss Monitoring at CTF3 for CLIC', IBIC 2013, Oxford, UK, [5] S. Vinogradov, A. Arodzero, R.C. Lanza, and C.P. Welsch., 'SiPM response to long and intense light pulses', NIMA 787, , [6] S. Vinogradov, “Probabilistic analysis of Solid State Photomultiplier performance”, Proc. SPIE 8375, 83750S, Challenges of arbitrary waveform signal detection by SiPM in beam loss monitoring systems with Cherenkov fibre readout Sergey Vinogradov 1,2,3, Lee Devlin 1,2, Eduardo Nebot del Busto 1,4, Maria Kastriotou 1,4, and Carsten P. Welsch 1,2 1 - Department of Physics, University of Liverpool, UK 2 - Cockcroft Institute of Accelerator Science and Technology, Daresbury, UK 3 - P.N. Lebedev Physical Institute of the Russian Academy of Sciences, Moscow, Russia 4 - CERN, Geneva, Switzerland Fig. 1. a) Beam Loss Monitoring (BLM): 150 MeV electrons in a beam line; an optical fibre for loss electrons to Cherenkov light conversion; SiPM (MPPC) as an upstream photon detector. b) SiPM (MPPC) readout of typical BLM signal: raw output (red, left scale) and a result of deconvolution (black, right scale) with single electron pulse response function (red, inset) [3]. Fig. 2. Degradation of SiPM response and performance due to nonlinearity [2, 6] a) General schematic outline: nonlinearity of calibration curve (output vs input) affects resolution; b) Photon number resolution models: binomial distribution, fixed dead time, exponential recovery. c) Probability density function of SiPM Gain: degradation from ~ delta-function due to incomplete recovering of pixels at high photon arrival rates. Fig. 3. Reward-renewal Markov process model of SiPM response to high-intensity step- function light pulse: a) Response components & contributions: probability density function (PDF) of inter-arrival times of potential events, transient pixel recovery process recovering its PDE during “dead time”, PDF of actual detected event times; evolution function (mean detection rate) of events after the first detection (plots are given for intensity of 3 phe/pixel/recovery). b) Mean SiPM response as a result of renewal process with a mean detection rate and reward process with a mean gain affected by incomplete recovering of pixels. Fig. 4. Comparative responses of Hamamatsu MPPC S C of 50 μm cell size 3x3 mm 2 area to rectangular light pulse of uniform illumination over active area; green trace is a LED pulse profile; blue trace is a MPPC response. Horizontal scale is 20 μs/div, vertical scales are 2, 10, 50, and 200 mV/div correspondingly. Direct readout of MPPC output signal to 50 Ohm oscilloscope input: DC – 1 GHz analogue bandwidth. Intensity ~ 1.1 phe/cell/recoveryIntensity ~ 4.3 phe/cell/recovery Intensity ~ 0.24 phe/cell/recoveryIntensity ~ 0.44 phe/cell/recovery Grant ‘SiPM in-depth’ Pixel load λτ → 0 PDF(Gain) → delta-function)