Toby Shoobridge David Benham NERC Space Geodesy Facility Herstmonceux, UK

Slides:



Advertisements
Similar presentations
OPTICAL FIBRE : TESTS AND MEASUREMENTS. BY TX-I FACULTY A.L.T.T.C; GHAZIABAD.
Advertisements

Session 4: Termination and Splices. 2 FO Connectors Specifications Specifications Loss Repeatability Environment (temp, humidity, vibration, etc.) Reliability.
ELECTRONIC GUIDING CANE FINAL PRESENTATION Students : David Eyal Tayar Yosi Instructor : Miki Itzkovitz Technion – Israel Institute Of Technology Electrical.
Measuring the Speed of Light Jack Young Rich Breazeale Ryan Phelan.
Laser ​ Distance measurement ​ by Aleksi Väisänen ​ Pauli Korhonen.
22-Nov-2004 © Renishaw plc Not to be reproduced without written permission from Renishaw Laser & Calibration Products Division Slide 1 Laser.
1 Laser Beam Coherence Purpose: To determine the frequency separation between the axial modes of a He-Ne Laser All sources of light, including lasers,
Distance observations
SURVEYING II UNIT IV PRESENTATION II.
Advanced Radio and Radar
S.H.H.S Building Construction
The Speed of Light How to hold a hallway hostage for fun and intellectual profit. (starring: the equipment)
Pump Probe Measurements of Femto-second Pulses By David Baxter.
Copyright © 2009 Pearson Education, Inc. Chapter 32 Light: Reflection and Refraction.
Use of a commercial laser tracker for optical alignment James H. Burge, Peng Su, Chunyu Zhao, Tom Zobrist College of Optical Sciences Steward Observatory.
Measuring the Speed of Light John Klumpp And Ainsley Niemkiewicz.
G D Calibration of the LIGO Interferometer Using the Recoil of Photons Justice Bruursema Mentor: Daniel Sigg.
Atacama Large Millimeter/submillimeter Array Expanded Very Large Array Robert C. Byrd Green Bank Telescope Very Long Baseline Array Green Bank Laser Rangefinders.
LumiCal Alignment System Status report Leszek Zawiejski, Tomasz Wojtoń, Arkadiusz Moszczyński Institute of Nuclear Physics PAN, Cracow 25th FCAL Collaboration.
Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display. PowerPoint to accompany Krar Gill Smid Technology of Machine.
Surveying Equipment.
Measuring the refractive index of transparent substances using a home tool: the laser meter Romulo Ochoa, Rich Fiorillo, and Cris R. Ochoa Department of.
1 Measurement of Solar Cell Using LED-based Differential Spectral Responsivity Comparator under High Background Irradiance Ghufron Zaid 1,2, Seongchong.
NA62 Gigatracker Working Group Meeting 2 February 2010 Massimiliano Fiorini CERN.
Chapter 9 Electromagnetic Waves. 9.2 ELECTROMAGNETIC WAVES.
Dense Wavelength Division Multiplexing (DWDM) Technology
Optics 2: REFRACTION & LENSES. REFRACTION Refraction: is the bending of waves because of the change of speed of a wave when it passes from one medium.
Fiber Optic Transmission
IPBSM status and plan ATF project meeting M.Oroku.
LASER AND ADVANCES IN METROLOGY
干涉仪实验 Michelson interferometer Sliver mirror Sliver mirror with piezo Sliver mirror HeNe source.
Quality Control Lecture 5
 a mathematical procedure developed by a French mathematician by the name of Fourier  converts complex waveforms into a combination of sine waves, which.
Refraction and Lenses.
Progress in UCSD Chamber Simulation Experiments – Initial Results from Fast Thermometer Farrokh Najmabadi Sophia Chen, Andres Gaeris, John Pulsifer HAPL.
Time Dilation We can illustrate the fact that observers in different inertial frames may measure different time intervals between a pair of events by considering.
Phase and Gain stability of optical fibre link used in MeerKAT Author : Roufurd Julie Supervised by : Prof Michael Inggs SKA HCD bursary conference Dec.
Fiber Optic Transmission SL/HL – Option C.3. Reflection/Refraction Reflection – A wave encounters a boundary between two mediums and cannot pass through.
11/22/2004EE 42 fall 2004 lecture 351 Lecture #35: data transfer Last lecture: –Communications synchronous / asynchronous –Buses This lecture –Transmission.
KHz-SLR PC Board Eastbourne, October 2005 for kHz SLR Complete PC Board.
Neutron detection in LHe ( HMI run 2004) R.Golub, E. Korobkina, J. Zou M. Hayden, G. Archibold J. Boissevain, W.S.Wilburn C. Gould.
Geology and Surveying (Part B - Surveying) Distance Measurement.
 Simply put, “Refraction” means bends.  When discussing light beams, light bends when it goes from one medium (glass, water, air, etc.) to another. 
My Chapter 26 Lecture.
Fiber Optic Transmission SL/HL – Option F Mr. Jean.
Sensors for Clear Object Detection
Instrument Calibration.  As previously discussed the principle of measurement is comparing a component against a known standard therefore any equipment.
I.Prochazka et al,ACES IWG meeting Neuchatel June 2014 European Laser Timing work progress Ivan Procházka, Josef Blažej (1), Jan Kodet (1,2) K.Ulrich Schreiber.
I.Prochazka et al,ACES ELT meeting Spring 2014 European Laser Timing work progress Ivan Procházka, Josef Blažej (1), Jan Kodet (1,2) presented at T2L2.
WP3 The LiCAS Laser Straightness Monitor (LSM) Greg Moss.
CfE Advanced Higher Physics
Charles University Prague Charles University Prague Institute of Particle and Nuclear Physics Absolute charge measurements using laser setup Pavel Bažant,
IB Physics Option F – Fibre Optics Mr. Jean. The plan: Video clip of the day Fibre Optics – C+-+Imaginghttps://ibphysics2016.wikispaces.com/Option+
SLR2000: current status & issues being worked Jan McGarry & Tom Zagwodzki Khz ranging session ILRS Workshop at Eastbourne October 2005.
ELT delays absolute calibration Ivan Procházka (1), Josef Blazej (1), Anja Schlicht (2) Prepared for ESA Webex meeting(s) March 2015 (1) Czech Technical.
How? With two timing systems:  FTLRS Stanford chronometer ( temperature controlled)  Dassault Timers as a reference What conditions?  Very short time.
I.Prochazka,et al, KOM ESOC, Darmstadt, April 2016 SPACE SITUATIONAL AWARENESS PROGRAMME P2-SST-VII EXPERT COORDINATION CENTRES (PHASE 1) Contribution.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Refraction and Lenses. Refraction is the bending of light as it moves from one medium to a medium with a different optical density. This bending occurs.
Refraction of Light Chapter 18, Section 1. Refraction  When light encounters a transparent or translucent medium, some light is reflected from the surface.
Time Calibration System for RF Cavity Breakdown Measurements Juan Takase Northwestern University SIST INTERN Fermi National Lab 08/04/2015.
30GHz system improvements Jan Kovermann RF meeting
National Highway Institute 5-1 REV-2, JAN 2006 EQUIPMENT FACTORS AFFECTING INERTIAL PROFILER MEASUREMENTS BLOCK 5.
1.Dimension measurement for calibration duties.
UNIT-3 ADVANCES IN METROLOGY
Visit for more Learning Resources
Speed Sensor Calibration
RADAR -Range and Bearing Discrimination and Accuracy.
Electronic Control Systems Week 4 – Signaling and Calibration
Leveling By : Parveen Kumar.
Presentation transcript:

Toby Shoobridge David Benham NERC Space Geodesy Facility Herstmonceux, UK

Aim To measure the delay in various components of our SLR two-way calibration Understand the Transmit-side delay

Necessity It has always been necessary to make a calibration to account for the two-way delays in an SLR system The Proposed work in T2L2 and LRO requires as accurate an epoch as possible for the laser pulse as it passes the system reference point

Current System Calibration Technique We range to a fixed ground target of a known distance to give us our calibration value This accounts for both Transmit-side and Receive- side delays as a whole Unfortunately this cannot simply be split into the two parts we’re interested in

Transmit-side Delay Laser Path from Start Diode to System Reference Point Delay in cables and electronic equipment from the Start Diode to Event Timer Comprised of:

Laser Path Need to know the time taken for the laser pulse to travel from the Start Diode to the System Reference Point. We measured this as two components: Laser bed including propagation effects of optics Coud é path length Transmit-side Delay

Laser Path Physical Measurements were made with a rule along the Laser Path. We also calculated the Effective increase in Path Length due to the Refractive Indices of Laser components. Laser Bed Measurements Beam Splitters Beam Expanders Amplifiers Quarts Rotator Doubler Crystal

Three methods employed to measure Coud é Path: Physical Measurements and Technical Drawings provided by manufacturers Reflected 10-Hz Laser Pulse Bosch Laser Rangefinder Laser Path

1 - Physical Measurements and Technical Drawings Drawings of Telescope, provided by manufacturer, were used to calculate coud é path from Telescope Base to System Reference Point Telescope Base down to Coud é Entrance was simply measured using a Tape Measure Physical Measurements not very accurate but useful as a comparison for other methods results Laser Path Coud é

2 - Reflected 10-Hz Laser Pulse Fired the 10-Hz Laser through the coud é reflecting it back via a mirror on the Emitter Laser Path Coud é

2 - Reflected 10-Hz Laser Pulse Setup Placed before Coud é Entrance Laser Path Coud é

2 - Reflected 10- Hz Laser Pulse Beam Splitter Two into One Fibre Optic Light Sensitive Diode Oscilloscope Laser Path Coud é

2 - Reflected 10-Hz Laser Pulse Oscilloscope shows Outgoing and Returning Semi train. Time difference between two pulses gives twice distance Laser Path Coud é

3 - Bosch Laser Rangefinder More commonly used as a building surveying tool Manufacturers state typical accuracy of ±1.5mm over 30m distance Laser Path Coud é

3 - Bosch Laser Rangefinder Rangefinder was aligned to ensure it measured directly up coud é Rangefinder laser is visible so was aligned to a target at the coud é entrance and on the emitter Very sensitive so required good alignment or it could take a reflection anywhere up the coud é path Laser Path Coud é

3 - Bosch Laser Rangefinder Emitter could then be removed and replaced with a flat surface for the Rangefinder to measure to Measurements were taken with telescope in different Azimuth positions Alignment and measurement process was repeated giving very good repeatability in results Laser Path Coud é

Results 1 - Physical Measurements and Technical Drawings mError ± 20 mm Difficulty in Physical Measurement of Coud é below Telescope 2 - Reflected 10-Hz Laser mError ± 30 mm Limited by accuracy in interpreting the Oscilloscope display Research more accurate ways of measuring timing between outgoing and returning pulses 3 - Bosch Laser Rangefinder mError ± 1.5 mm Most accurate and repeatable method All agree within 25mm. Laser Path Coud é

Start Diode LeCroy Discriminator Event Timer Cables Transmit-side Delay Cables and Electronic Equipment

Beam Splitter used to direct pulse to Diode Diode mounted 25.5 mm from Beam Splitter Delay in Diode Components - To be Determined Cables and Electronic Equipment Start Diode

Series of Calibrations using kHz Laser Compare Calibration results with Cables/LeCroy in and out of the chain between Start Diode and ET Cables and LeCroy Measurement Cables and Electronic Equipment Change in Ranged Distance to Fixed Target gives delay in particular Cable/Device added

Internal Delay from external socket to when timer is triggered is to be determined /unknown Event Timer Cables and Electronic Equipment

Total Delay between Start Diode and ET Start Diode To be Determined Beam Splitter to Diode0.027 m Cables Diode to LeCroy: m LeCroy to ET: m LeCroy LeCroy currently in use: m Event Timer To be Determined Total: m Cables and Electronic Equipment

Useful comparison for the Delay found in the Coaxial Cable used Signal propagation through cable can be expressed as a percentage of speed of light Approximate figure found for the type of coaxial cable we measured would be 66% This would tend to agree with results found for the cables tested. As with the Start Diode to LeCroy Cable for example: Physical Length m Effective Length at 66% light speed m Effective Length using calibration method m Cables and Electronic Equipment

Subtract Laser Path Delay from Cable and Electronic Equipment Delay Transmit-side Delay Difference between the time the laser passes through the System Reference Point and ET is triggered Using Electronic Delay results so far and Coud é path measurements with Bosch Laser Rangefinder m m = m = ns Error Estimate <1ns So the Laser Pulse passes through the System Reference Point 21 ns before the Event Timer is triggered

More Tests on LeCroys and Cables Event Timer Delay Start Diode Delay Measure all Receive-side delays to close the loop and compare against our standard two-way calibration result Setup to enable measurement of Transmit-side delay as one measurement Transmit-side Delay Further work

Measuring Transmit-side delay as one measurement Transmit-side Delay Further work Run a Calibration similar to our two-way calibration/ranging setup Place a Diode on or near the System reference point in the laser path Feed pulse from the Diode to ET stop instead of the SPAD pulse This requires good understanding of the delay in only Diode and Cable Can be used to calibrate regularly and when any changes occur in Transmit-side of SLR system

Conclusion We are heading towards providing an epoch for the time the laser pulse passes the System Reference Point necessary for LRO and T2L2 Current measurements give a 21ns correction with an accuracy better than 1 ns. Still to include ET and Start Diode.