Optimizing DHCAL single particle energy resolution Lei Xia Argonne National Laboratory 1 LCWS 2013, Tokyo, Japan November 11 - 15, 2013.

Slides:



Advertisements
Similar presentations
US CMS H1/H2 Issues1 H C A L Dan is interested in the calibration of the HCAL for jets. He defines “R” as the measured energy of a pion, probably in ADC.
Advertisements

Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.
Status of DHCAL Slice Test Data Analysis Lei Xia ANL-HEP All results preliminary.
Simulation of the RPC Response José Repond Argonne National Laboratory CALICE Collaboration Meeting University Hassan II Casablanca, Morocco September.
First analysis of DHCAL Data José Repond Argonne National Laboratory Linear Collider Workshop LCWS 2012 October 22 – 26, 2012 University of Texas at Arlington,
1 Study of the Tail Catcher Muon Tracker (TCMT) Scintillator Strips and Leakage with Simulated Coil Rick Salcido Northern Illinois University For CALICE.
1 N. Davidson E/p single hadron energy scale check with minimum bias events Jet Note 8 Meeting 15 th May 2007.
PFA on SiDaug05_np Lei Xia ANL-HEP. PFA outline Calibration of calorimeter –Done –Not tuned for clustering algorithm Clustering algorithm –Done: hit density.
GEM DHCAL Simulation Studies J. Yu* Univ. of Texas at Arlington ALCW, July 15, 2003 Cornell University (*on behalf of the UTA team; S. Habib, V. Kaushik,
 Track-First E-flow Algorithm  Analog vs. Digital Energy Resolution for Neutral Hadrons  Towards Track/Cal hit matching  Photon Finding  Plans E-flow.
1 N. Davidson E/p minimum bias update with Athena Analysis Meeting 12 th June 2007.
Simulation of the DHCAL Prototype Lei Xia Argonne National Laboratory American Linear Collider Workshop: Ithaca, NY, July , 2003 Fe absorber Glass.
1 N. Davidson, E. Barberio E/p single hadron energy scale check with minimum bias event Hadronic Calibration Workshop 26 th -27 th April 2007.
PFA Development – Definitions and Preparation 0) Generate some events w/G4 in proper format 1)Check Sampling Fractions ECAL, HCAL separately How? Photons,
1 N. Davidson Calibration with low energy single pions Tau Working Group Meeting 23 rd July 2007.
1/9/2003 UTA-GEM Simulation Report Venkatesh Kaushik 1 Simulation Study of Digital Hadron Calorimeter Using GEM Venkatesh Kaushik* University of Texas.
José Repond Argonne National Laboratory Review of the Status of the RPC-DHCAL SiD Workshop SLAC, Stanford, California October 14 – 16, 2013.
Simulation of RPC avalanche signal for a Digital Hadron Calorimeter (DHCAL) Lei Xia ANL - HEP.
Progress with the Development of Energy Flow Algorithms at Argonne José Repond for Steve Kuhlmann and Steve Magill Argonne National Laboratory Linear Collider.
Energy Flow and Jet Calibration Mark Hodgkinson Artemis Meeting 27 September 2007 Contains work by R.Duxfield,P.Hodgson, M.Hodgkinson,D.Tovey.
Development of Particle Flow Calorimetry José Repond Argonne National Laboratory DPF meeting, Providence, RI August 8 – 13, 2011.
Analysis of DHCAL Data José Repond Argonne National Laboratory CALICE Collaboration Meeting September 17 – 19, 2012 Cambridge, UK.
Summary of Calorimetry/Muon Sessions Burak Bilki University of Iowa Argonne National Laboratory.
Optimizing DHCAL single particle energy resolution Lei Xia 1 CALICE Meeting LAPP, Annecy, France September 9 – 11, 2013.
DHCAL - Resolution (S)DHCAL Meeting January 15, 2014 Lyon, France Burak Bilki, José Repond and Lei Xia Argonne National Laboratory.
José Repond Argonne National Laboratory Status of the DHCAL Project SiD Collaboration Week January 12 – 14, 2015 SLAC.
Digital Hadron Calorimeter (DHCAL) José Repond Argonne National Laboratory CLIC Workshop 2013 January 28 – February 1, 2013 CERN, Geneva, Switzerland.
Tests of a Digital Hadron Calorimeter José Repond Argonne National Laboratory CALICE Collaboration Meeting March 10 – 12, 2010 University of Texas at Arlington.
Event Reconstruction in SiD02 with a Dual Readout Calorimeter Detector Geometry EM Calibration Cerenkov/Scintillator Correction Jet Reconstruction Performance.
CALICE Digital Hadron Calorimeter: Calibration and Response to Pions and Positrons International Workshop on Future Linear Colliders LCWS 2013 November.
16-Nov-2002Konstantin Beloous1 Digital Hadron Calorimeter Energy Resolution.
Development of a Particle Flow Algorithms (PFA) at Argonne Presented by Lei Xia ANL - HEP.
UTA GEM DHCAL Simulation Jae Yu * UTA DoE Site Visit Nov. 13, 2003 (*On behalf of the UTA team; A. Brandt, K. De, S. Habib, V. Kaushik, J. Li, M. Sosebee,
Analysis of DHCAL Muon Events José Repond Argonne National Laboratory ALCPG 2011 Meeting, University of Oregon, Eugene, OR.
W-DHCAL Analysis Overview José Repond Argonne National Laboratory.
OPERA Neutrino Experiment Tija Sīle presentation is based on: Doktorantūras skolas “Atomāro un nepārtrauktās vides fizikālo.
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
Update on DHCAL and RPC progress Lei Xia ANL - HEP.
Min-DHCAL: Measurements with Pions Benjamin Freund and José Repond Argonne National Laboratory CALICE Collaboration Meeting Max-Planck-Institute, Munich.
CALOR April Algorithms for the DØ Calorimeter Sophie Trincaz-Duvoid LPNHE – PARIS VI for the DØ collaboration  Calorimeter short description.
DHCAL Overview José Repond Argonne National Laboratory CALICE Collaboration Meeting Argonne National Laboratory March 19 – 21, 2014.
Reconstructing energy from HERD beam test data Zheng QUAN IHEP 3 rd HERD work shop Xi’an, 20 Jan
1 1 - To test the performance 2 - To optimise the detector 3 – To use the relevant variable Software and jet energy measurement On the importance to understand.
Longitudinal shower profile - CERN electron runs Valeria Bartsch University College London.
Update on Diffractive Dijets Hardeep Bansil University of Birmingham 12/07/2013.
Imaging Hadron Calorimeters for Future Lepton Colliders José Repond Argonne National Laboratory 13 th Vienna Conference on Instrumentation Vienna University.
Testbeam analysis Lesya Shchutska. 2 beam telescope ECAL trigger  Prototype: short bars (3×7.35×114 mm 3 ), W absorber, 21 layer, 18 X 0  Readout: Signal.
Future DHCAL Activities José Repond Argonne National Laboratory CALICE Meeting, CERN, May 19 – 21, 2011.
09/06/06Predrag Krstonosic - CALOR061 Particle flow performance and detector optimization.
Energy Reconstruction in the CALICE Fe-AHCal in Analog and Digital Mode Fe-AHCal testbeam CERN 2007 Coralie Neubüser CALICE Collaboration meeting Argonne,
Simulation studies of total absorption calorimeter Development of heavy crystals for scintillation and cherenkov readout Dual readout in the 4 th concept.
W Prototype Simulations Linear Collider Physics & Detector Meeting December 15, 2009 Christian Grefe CERN, Bonn University.
Analysis of DHCAL Data José Repond Argonne National Laboratory CALICE Meeting, September 16 – 18, 2009 Université Claude Bernard Lyon I, France.
Analysis of DHCAL Muon Events José Repond Argonne National Laboratory TIPP 2011 Conference, Chicago, June , 2011.
W-DHCAL Digitization T. Frisson, C. Grefe (CERN) CALICE Collaboration Meeting at Argonne.
21/09/2010CALICE Manqi RUAN Laboratoire Leprince-Ringuet (LLR) Ecole Polytechnique 91128, Palaiseau Status of DHCAL PFA Study.
A Study on Leakage and Energy Resolution
Analysis of DHCAL Events
on behalf of ATLAS LAr Endcap Group
The DHCAL – An overview José Repond Argonne National Laboratory
Analysis of Muon Events in the DHCAL
State-of-the-art in Hadronic Calorimetry for the Lepton Collider
Observation of Diffractively Produced W- and Z-Bosons
Rick Salcido Northern Illinois University For CALICE Collaboration
Argonne National Laboratory
Tests of a Digital Hadron Calorimeter
Observation of Diffractively Produced W- and Z-Bosons
Tests of a Digital Hadron Calorimeter
Steve Magill Steve Kuhlmann ANL/SLAC Motivation
Presentation transcript:

Optimizing DHCAL single particle energy resolution Lei Xia Argonne National Laboratory 1 LCWS 2013, Tokyo, Japan November , 2013

Introduction Single particle energy resolution of a traditional calorimeter can be optimized by hardware/software compensation – Equalize EM and Hadronic responses -> e/h ~ 1 The DHCAL is quite a unique/different device – Non-linear response for EM shower Measured energy of a 10 GeV photon E(10) E(10) ≠ E(5) + E(5) ≠ E(2) + E(2) + E(2) + E(2) + E(2) Correction can be applied for single EM showers No obvious way to correct for pi0’s generated in hadronic showers – Hadronic response close to linear -> Ratio of EM to hadronic response changes with energy – Software compensation not likely to be very successful without first taking care of the non-linearity of the EM response 2

Linearizing the EM response I The non-linear response of EM showers is due to finite readout pad size  multiple particles hitting same pad  saturation Need ways to account for multiple particles on the same pad – Assumption: Hit density (hit fraction in a given local space) is related to the local particle density (Density weighted calibration proved good correlation between hit density and local particle density) – Start with simple hit density definition d9: number of hits in the surrounding 3pad x 3pad area, centered on the hit being studied (d9 = 0 – 8) – Start with MC simulation for Fe absorber setup RPC response: RPC_sim_4 (single exponential) – not the best… Positron sample: 2, 4, 6, 8, 10, 12, 16, 20, 25, 32, 40, 60 (GeV) Pion sample: 2, 4, 6, 8, 10, 12, 16, 20, 25, 32, 40, 60, 80, 100 (GeV) 3

Linearizing the EM response II Chose two sets of positron energy points, adjust weights for each D9 bin to achieve linear response – Set I (wt1): 2, 6, 10, 16, 25 (GeV) – Set II (wt2): 2, 6, 16, 32, 60 (GeV) – Target response: hits/GeV (arbitrary) High weights for isolated hits Low weights for medium density: mostly due to hit multiplicity ~ 1.6 Very high weight for high density bins: correction for saturation Everything as expected 4

Positron response after weighting Things are exactly as expected: Linearity significantly improved wt2 gives better linearity in larger energy range than wt1 5 Fits to power law (β =1 means linear)

Positron resolution after weighting Non-linearity correction is included (this is very important!) Positron energy resolution modestly improved (2 – 11%) Not much difference between wt1 and wt2 All energy resolutions were calculated from full-range Gaussian fit Fit at low energies are not very reliable 6

Pion response Pion linearity (no weighting) is much worse than in data (most likely due to inaccurate positron simulation) Linearity fits are not as good as the positrons * Applied leakage cut: no more than 10 hits in tail catcher 7

Pion resolution Pion resolution and linearity are both greatly improved in (not very good) simulation: 10 – 50% At higher energies, distributions become much more symmetric after weighting Example: 60 GeV response 8

Pion vs. Positron response Before weightingAfter weighting Pion and Positron responses are brought closer by weighting, but not equal yet (weighting changes both pion and positron responses) Room for software compensation: work in progress (pretty optimistic on further improvement) 9

More density weighting It seems that things work best with very different e/p responses and very non-linear EM response One obvious place is W-DHCAL data: studies using simulated events – Electron sample: 2, 4, 6, 8, 10, 20, 30, 40, 50, 60, 80, 100 (GeV) – Pion sample: 8, 10, 20, 30, 40, 50, 80, 100, 120, 150, 180, 300 (GeV) – Weights tuned with electron energy points: 4, 10, 30, 50, 80 (GeV) 10 weights Density bin d9

Electron response Response is highly non-linear without weighting Weighting does a good job, as with the Fe-DHCAL (tuning target was 10 Hits/GeV, again, arbitrary) 11

Electron resolution As with the Fe-DHCAL, no significant improvement Fits at low energy points are not reliable 12

Pion response As usual, fits are not great as compare to electron fits 300 GeV point systematically low  Excluded from fits All high energy points are low probably due to bias from leakage cut Fit parameters are also systematically low, probably due to the above reason Nevertheless, linearity did improve significantly 13

Pion resolution Energy resolution greatly improved over large energy range: 24 – 54% Weighing improved distribution, but didn’t totally remove low end tail 14 Example: 50 GeV response

Pion vs. electron responses Before weightingAfter weighting e/h improved with density weighting Difference is still very large  ideal test bed for software compensation 15

Summary Density weighting is able to achieve close to linear EM shower response for DHCAL Using the same weights can improve linearity and energy resolution of pion showers – Significant (~ %) improvement observed with Fe- DHCAL and W-DHCAL simulation – Applying the same technique for test beam data is on- going, results will come soon Pion and EM shower response are still quite different after weighting – Chance for software compensation: work started Once we have the method to get optimized energy resolution for DHCAL, we should think of optimizing the DHCAL design itself… 16