© S. Balter 2008 SB0802 IHE - 1 Radiation Dose Data Management IHE Presentation – February 2008 Stephen Balter, Ph.D. Columbia University Medical Center,

Slides:



Advertisements
Similar presentations
RSNA 2003 The IHE Technical Approach Identify the transactions required to integrate information flow between information systems For each transaction,
Advertisements

Reporting Workflow Rita Noumeir, Ph.D. IHE Technical Committee.
What IHE Delivers 1 Radiation Exposure Monitoring: IHE REM Profile Kevin ODonnell Toshiba Medical Systems Co-chair, IHE Radiology Planning Cmte.
Integrating the Healthcare Enterprise
Paolo Gemma, Senior Expert, Huawei
Normal Brain Parameters Hand Morphology Electron Density Map Image Equalization 3D,4D Reconstructions. Dual Enery Reconstr. Normal Brain Parameters Hand.
Computed Radiography Digital Radiography LeeAnn Pack DVM Diplomate ACVR.
IHE Radiology Integration Profiles: ▪ Post-Processing Workflow ▪ Reporting Workflow IHE Educational Workshop – June 11-13, 2007 Nikolaus Wirsz, PhD Manager.
State of Michigan Computed Tomography Regulations
The Field of Digital Radiography
Time to Wave the White Flag – Compliance with the FTC’s Identity Theft Red Flags Rule William P. Dillon, Esq. Messer, Caparello & Self, P.A Centennial.
1 NEXT 2000: Survey of Computed Tomography (CT) Practice, Workload, Dose Stanley H. Stern, Ph. D. FDA/CDRH Office of Health and Industry Programs Division.
Business: Cell/Text: Presented by: Thomas J. LaRocca, M.S., D.A.B.R. Medical Physicist
The PAC System By Andi Sherman CIS Spring Intro to Radiology Radiology is a fast growing area of the health profession in most hospitals and private.
Standar-standar yang melibatkan radiologi
Statscan Critical Imaging System. The concept of this device was originally developed & had its beginnings in the diamond mines of South Africa It was.
Prelim 11/14/11. 2 nd Semester, 3 rd Year Level  The Early 1900’s, With The Work Of An Industrial Engineer Named Frederick Winslow Taylor.  “Father.
Picture Archiving And Communication System (PACS)
Picture Archiving and Communication System (PACS) -Krystal Kerney and Hui Pan.
TERPSSC 2001Robert M. Gagne OVERVIEW OF DIGITAL IMAGING AND RADIATION PROTECTION ISSUES Robert M. Gagne MICAB/DECS/OST [From: Handbook.
IHE Radiology Scheduled Workflow for Import Peter Kuzmak, Cindy Levy, Dr. Ruth Dayhoff and Andrew Casertano November 2005.
1 Image Quality Assurance-#705 Bonnie Matlack, R.T. VistA Imaging Coordinator Kansas City VA Medical Center.
How to Go Digital (Advanced) Press Space Bar or Click Mouse to Advance.
Today’s Lecture application controls audit methodology.
Solution Overview for NIPDEC- CDAP July 15, 2005.
Implementing POS at LVHN The Ups and Downs Lynnette Clinton – Manager, Rev Cycle Systems Tricia DeBlass – Subject Matter Expert Stephanie Erwin – Systems.
Future Of Diagnostic Imaging A Look Into The Next Decade ? (Part 3)
Electronic Health Records Dimitar Hristovski, Ph.D. Institute of Biomedical Informatics.
IAEA International Atomic Energy Agency Interventional Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(3)
June 28-29, 2005 IHE - Effective Integration of the Enterprise and the Health System 1 Integrating the Healthcare Enterprise Presentation of Grouped Procedures.
Product Development Chapter 6. Definitions needed: Verification: The process of evaluating compliance to regulations, standards, or specifications.
IAEA International Atomic Energy Agency Dental Radiology Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 2(2)
TEPRSSC Meeting CDRH Update Lillian Gill October 1, 2003.
Feb , 2005IHE Europe Workshop 1 Integrating the Healthcare Enterprise – Radiology – Established IHE Integration Profiles: Dr. Nikolaus Wirsz –Siemens.
BEIR VII Implications of the Report for the Future of Medical Imaging G. Donald Frey, Ph.D. Department of Radiology Medical University of South Carolina.
IT Application in Health Care
RAD 254 Digital Imaging Basic Elements of Digital Imaging CR/DR.
Sharing Value Sets (SVS Profile) Ana Estelrich GIP-DMP.
Dose Audit in Fluoroscopy Colin Martin and David Sutton.
September, 2005What IHE Delivers 1 Purchasing & Integrating Radiology Systems Using IHE A Tutorial Presenter Name Presenter Company Presenter Role in IHE.
Radiation Exposure Monitoring (REM) Profile Kevin O’Donnell Toshiba Medical Research Inst. - USA Co-chair, IHE Radiology Planning Cmte IHE Radiology.
This class cannot be shared or copied without the written permission of PracticeWorks Systems, LLC.
Amanda Bath Advance Practitioner RPS
Understanding radiation units L02
Chapter 9. Copyright ©2012 by Pearson Education, Inc. All rights reserved. Essentials of Dental Radiography for Dental Assistants and Hygienists, Ninth.
Sept 13-15, 2004IHE Interoperability Workshop 1 Integrating the Healthcare Enterprise Presentation of Grouped Procedures Charles Parisot, GE Healthcare.
February 8, 2005IHE Europe Educational Event 1 Integrating the Healthcare Enterprise Presentation of Grouped Procedures Charles Parisot, GE Healthcare.
RADIOGRAPHY & IT’S MODALITIES SPRING INFORMATION WORKSHOP 2011.
Copyright © 2006 by The McGraw-Hill Companies, Inc. All rights reserved. McGraw-Hill/Irwin 6-1 Chapter Six Internal Control in a Financial Statement Audit.
Managing Radiation Dose: IHE REM Profile
Reduce Waiting & No-Shows  Increase Admissions & Continuation Reduce Waiting & No-Shows  Increase Admissions & Continuation Lessons Learned.
DICOM INTERNATIONAL DICOM INTERNATIONAL CONFERENCE & SEMINAR April 8-10, 2008 Chengdu, China Product Experiences Cor Loef Philips Healthcare.
Radiation Sources in medicine diagnostic Radiology
Cumulative dose and skin damage
Management System Part II: Inventory of Radiation Sources – Regulatory Authority Information System (RAIS)
WG-28 Goals Modalities and Types of Procedure
Doses in Fluoroscopy factors influencing patient doses Colin Martin and David Sutton.
The University of Toledo Finance and Audit Committee Meeting “Internal Audit and Compliance Update” September 21, 2015.
IHE Workshop – February 2007 What IHE Delivers 1 Credits for many slides to: Cynthia A. Levy, Cedara Software IHE Technical Committee Import Reconciliation.
ADMINISTRATIVE AND CLINICAL HEALTH INFORMATION. Information System - can be define as the use of computer hardware and software to process data into information.
Sept 13-15, 2004IHE Interoperability Workshop 1 Integrating the Healthcare Enterprise Reporting Workflow Key Image Notes Evidence Documents Rita Noumeir,
Digital Radiography Chapter 26. Digital radiographs Different from analog images (traditional radiographs). Filmless imaging using pixels. Instant images.
Presentation of Grouped Procedures Integration Profile Charles Parisot GE Medical Systems IT Planning and Technical Radiology Committees.
Monsour Roi M. Monzon, RN.  What is Electronic Health Record?  Electronic Medical Record (EMR) vs Electronic Health Record (EHR)  Comparison with Paper-based.
Sharan Packer Specialist Inspector (Radiation)
CMMI – Staged Representation
Ethical Considerations for Pediatric Clinical Investigations
Presentation transcript:

© S. Balter 2008 SB0802 IHE - 1 Radiation Dose Data Management IHE Presentation – February 2008 Stephen Balter, Ph.D. Columbia University Medical Center, New York, New York

© S. Balter 2008 SB0802 IHE - 2 Measurements and documentation When you can measure what you are speaking about, and express it in numbers, you know something about it; but when you cannot measure it, when you cannot express it in numbers, your knowledge is of a meager and unsatisfactory kind. Lord Kelvin ( ) 1902 Skiameter of Benoist

© S. Balter 2008 SB0802 IHE - 3 Purposes and costs The purpose of any diagnostic procedure is to reduce uncertainty about the patient’s health status. The purpose of most therapeutic procedures is to stabilize or improve the patient’s health. There are always associated costs –Money and time –Procedural risks –Often radiation risks

© S. Balter 2008 SB0802 IHE - 4 Real World Case Range Patient brought into the emergency room by ambulance after an auto crash with evidence of multi-organ trauma. PCI in place of coronary bypass surgery. Screening mammogram. Employee of a high-tech company visiting a ‘wellness clinic’ for an annual check-up. Offered add-on CT scans ‘as long as you are already on the table’. Whole body security CT scan (before visiting a prisoner or boarding an aircraft).

© S. Balter 2008 SB0802 IHE - 5 Past radiation history Rarely has any influence on the decision to order a diagnostic procedure. May provide additional help in interpreting the results of a diagnostic procedure. Can be important in planning therapeutic procedures. Imaging history is another matter.

© S. Balter 2008 SB0802 IHE - 6 Historical dose recording Non regulatory recommendations for dose recording –In some form since early 20 th century –FDA Radiation “Passport” (circa 1970) –SIR Standard of practice (2004) Interventional –FDA Recommendation (1994):Record skin dose and location –IEC (2001): KAP and Dose at Reference Point –FDA Regulations (2005): Dose at Reference Point (new fluoroscopic equipment) DICOM MPPS Report (1996) –Assumes RIS and linkages EURATOM Directive (1997) –National Dose Recording Regulations –Primarily KAP (Stochastic Risk Concerns) –No formal scheme for recording –Space available in DICOM Headers

© S. Balter 2008 SB0802 IHE - 7 FDA X-RAY Record Card c 1970

© S. Balter 2008 SB0802 IHE - 8 NCRP 2008? US Population Dose

© S. Balter 2008 SB0802 IHE - 9 FDA Poster Child

© S. Balter 2008 SB0802 IHE - 10 Why capture dose data? Patient Risk Supervision –Deterministic –Stochastic (not really applicable to an individual patient) Quality Assurance –Departmental vs. Guidance Levels –Local deviations Equipment Operators –CQI process Regulatory Mandate

© S. Balter 2008 SB0802 IHE - 11 How much to capture? Stochastic risk to the population –Collect everything? –Sampling Deterministic injury potential –Collect data on every procedure where injury is possible Quality Assurance –Collect everything (for local use)

© S. Balter 2008 SB0802 IHE - 12 Data elements Direct dose measurements Technical settings of equipment Irradiation geometry Patient and procedure data

© S. Balter 2008 SB0802 IHE - 13 Modalities Radiography, Mammography, and Fluoroscopy –Closed system with digital image capture –Independent image receptor with CR or DR –Film/screen image receptor Dental Radiography –DR image receptor –Film image receptor Computed Tomography

© S. Balter 2008 SB0802 IHE - 14 Fluoroscopy All images via common digital video channel Feedback loop for Automatic Dose Rate Control (ADRC) Copper spectral shaping filters (Flat detector) IEC

© S. Balter 2008 SB0802 IHE - 15 Issues 2008 DICOM header data usually only exists when digital images are saved. MPPS report is often an exact mirror of the headers of saved images. No info usually available –Procedures without any saved images –Procedures partially saved images –Repeated exposures

© S. Balter 2008 SB0802 IHE - 16 Available dose metrics Reference Point Air Kerma (K a,r ) –IEC (2000) –FDA (2005) Kerma Area Product (P KA ) –IEC (2000) –Common in Europe Fluoroscopy Time ± Number of Images Skin Dose Maps

© S. Balter 2008 SB0802 IHE - 17 Analysis using DICOM header or MPPS

© S. Balter 2008 SB0802 IHE - 18 DICOM-DOSE Project DICOM Limitations –Data is bound to DICOM digital images. –Little or no data about non-stored images. –DICOM MPPS process needs tight coupling to an informatics system Project –The need for complete documentation of interventional procedures was presented to the IEC (62b MT38) by DIMOND –Co-developed with DICOM committee –Initial version covers all projection radiography and fluoroscopy (except mammography). –Mammo and CT extensions are foreseen.

© S. Balter 2008 SB0802 IHE - 19 DD simulation using service log

© S. Balter 2008 SB0802 IHE - 20 RDSR Outputs Near Real Time Updated RDSR transmitted over network after each irradiation Post Procedure Complete RDSR transmitted over network once procedure is marked as complete. Sneaker Net RDSRs stored in imaging system extracted on storage media and physically carried to AGENT IEC PAS specifies storage of at least 500 RDSRs with or without network connections. AGENT LOCATIONS PACS, RIS, Independent

© S. Balter 2008 SB0802 IHE - 21 IEC PAS Overview Claimed compliance with an IEC standard assures minimum requirements IEC Compliance Levels Based on maximum expected cumulative Air Kerma at the IEC interventional reference point for any normal use of the equipment 1: Stochastic Risk Only (< 2 Gy expected) 2: Deterministic Injury Conceivable (> 2 Gy) 3: Deterministic Injury Possible (> 7 Gy) Presently a place-holder in the standard Implementation planned when adequate dose- mapping software is available

© S. Balter 2008 SB0802 IHE - 22 IEC Level 1 Equipment where the estimated maximum cumulative Air Kerma for any examination (study) is expected to be less than two (2) gray (Gy) for all normal uses The defining dose is the cumulative dose for a complete examination at the interventional reference point defined in IEC (for equipment capable of measuring Air Kerma at this point or The equipment manufactures estimate of the cumulative dose for a complete examination at the closest point to the X-ray source where the patient’s skin might be placed

© S. Balter 2008 SB0802 IHE - 23 Not only stored digital images The RDSR is a DICOM object that is independent of any stored images Valid RDSRs can be generated by equipment used to produce stored or not-stored analog or digital images IEC specifies that RDSRs be stored by the imaging equipment (downloaded locally or via a network)

© S. Balter 2008 SB0802 IHE - 24 Verification of displayed “dose” Accuracy of display –IEC ± 50% (RPDose &KAP) –FDA ± 35% (RPDose) –Stability usually better Usually validated at factory Seldom validated by installers When verified as part of QA Should be able to maintain ± 20%

© S. Balter 2008 SB0802 IHE - 25 Generic Cases Forget-about-it Regulatory Requirement –All Procedures –Reportable Procedures Institutional Quality Program –All procedures with subgroups for trending –Out of bounds procedures Stochastic Risk Estimates –Data from population (complete or sampled) –Individual patient (significant difficulties in validly using data) Potential Tissue Reaction –All patients at risk Standards of care –Establish reference (guidance) levels –Monitor radiation load on population and its sources

© S. Balter 2008 SB0802 IHE - 26 Sources of Data X-ray producing equipment Manual data entry Robotic translation (straw man)

© S. Balter 2008 SB0802 IHE - 27 Consumers of Data Quality management Research community –Generate reference levels –Estimate population risks Policy makers Individual providers (potential tissue reactions) Individual patients ???

© S. Balter 2008 SB0802 IHE - 28 IHE and data collection issues Procedure Lexicon Accuracy of reported procedure names and description Accuracy of demographic data Accuracy of dosimetric data Missing data