Protect, Enhance, and Save Lives - 1 - III ARDENT Annual Workshop 29/09-02/10/2014 IBA Dosimetry Francesca Bisello ESR 10.

Slides:



Advertisements
Similar presentations
Diode detector (PIN photo diode detector)
Advertisements

 Digital Mammography  X ray tests  Phantoms spectra  Bilateral Project (ICM-tube X-ray) Development of a silicon detector for photon counting to be.
Ionization Chamber Array for External Beam Radiotherapy
STATUS OF MEDIPIX-3, PLANS FOR TIMEPIX-2 X. Llopart.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
SOIPD Status e prospective for 2012 The SOImager2 is a monolithic pixel sensor produced by OKI in the 0.20 µm Fully Depleted- Silicon On Insulator (FD-SOI)
Ultra-Fast Silicon Detector 1 This report is a summary of what was shown at IEEE. Nicolo Cartiglia, INFN, Torino - UFSD - Timing Workshop CERN 2014 Nicolo.
Evaluation of various diagnostic x-ray measuring devices MDCH Radiation Safety Section Don Parry, CHP.
Mechanical and fluidic integration of scintillating microfluidic channels into detector system 1 Davy Brouzet 10 th September 2014.
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Production Chapter 8.
Dosepix – a detector for quality assurance in Medical Imaging
A High-speed Adaptively-biased Current- to-current Front-end for SSPM Arrays Bob Zheng, Jean-Pierre Walder, Henrik von der Lippe, William Moses, Martin.
Quality Control Rad T 110.
Purity measurement at SOLEIL Nicolas HUBERT # on behalf of the diagnostics group: N. Hubert, L. Cassinari, F. Dohou, M. El Ajjouri, M. Labat, D. Pédeau,
Michele Togno ARDENT ESR 11 – 2D Ionization Chambers Array for Clinical Applications Michele Togno – ARDENT midterm review preparatory meeting, CERNJune,
R&D on pixel sensors at ILC ILC Workshop - November 2006 – Valencia.
Introduction on SiPM devices
Erik Fröjdh CERN, Mid Sweden University. Characterization of hybrid pixel detectors Applications for dosimetry in mixed radiation fields.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.03: Optimization of protection in Mammography.
Pierpaolo Valerio.  CLICpix is a hybrid pixel detector to be used as the CLIC vertex detector  Main features: ◦ small pixel pitch (25 μm), ◦ Simultaneous.
Applications of a Pixellated Detection System to Digital Mammography
Milestones M5 and M6 Mid-Term Review, October 2013M. Silari – ARDENT overview1 M5: comparison of detector technologies (WP1) M6: choice of detector technology.
M. Silari - ARDENT Kick-off meeting 1CERN, 8 May 2012 ARDENT implementation and execution M. Silari.
M. Silari - The ARDENT ITN project 1CNAO, Pavia, 19 October 2012 ARDENT February 2012 – January 2016 Advanced Radiation Dosimetry European Network Training.
Temperature dependence of sensor leakage current Contents Introduction Measurement Result Summary Junkichi Asai (RIKEN BNL Research Center) (Hiroki kanoh.
M. Silari - The ARDENT ITN project 1EURADOS, Vienna, 7-10 February 2012 ARDENT February 2012 – January 2016 Advanced Radiation Dosimetry European Network.
S. Mattiazzo 1,2, M. Battaglia 3,4, D. Bisello 1,2, D. Contarato 4, P. Denes 4, P. Giubilato 1,2,4, D. Pantano 1,2, N. Pozzobon 1,2, M. Tessaro 2, J. Wyss.
Factors affecting CT image RAD
05/05/2004Cyrille Thomas DIAMOND Storage Ring Optical and X-ray Diagnostics.
ARDENT Advanced Radiation Dosimetry European Network Training initiative WP1: Gas Detectors S. Rollet.
IRMF/IPEM Diagnostic X-ray Intercomparison Jan Participants: Hospital Medical Physicists/Clinical Scientists QA Radiographers.
Elsevier items and derived items © 2009 by Mosby, Inc., an affiliate of Elsevier Inc. X-Ray Emission Chapter 9.
Historical Review and Modalities in Diagnostics
ERIK FRÖJDH – ESR 2 Mid Sweden University, CERN 14th October 20132nd ARDENT Workshop1.
RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY
MEASUREMENTS OF RADIATION DOSES IN MULTISLICES COMPUTED TOMOGRAPHY EXAMINATIONS A. ELMAHDI*, A. SULIEMAN *Presenting author 1 Sudan Atomic Energy Commission,
The development of the readout ASIC for the pair-monitor with SOI technology ~irradiation test~ Yutaro Sato Tohoku Univ. 29 th Mar  Introduction.
Part No...., Module No....Lesson No
RESMDD02 July , Florence, A.Singovski, University of Minnesota1 Radiation hardness of the Avalanche Photodiodes for ECAL CMS detector at CERN.
On a eRHIC silicon detector: studies/ideas BNL EIC Task Force Meeting May 16 th 2013 Benedetto Di Ruzza.
Francesca Bisello, Prague , IV ARDENT Workshop IV ARDENT Annual Workshop 22-26/06/2015 Prague Francesca Bisello ESR 10.
Examples of Good & Bad Practice: Effect of the wedge filter and field size in the skin dose distribution L 9.1.
Activities within the ARDENT- project: November 2012 – June 2013 Benedikt Bergmann Institute of Experimental and Applied Physics, Czech Technical University.
IAEA International Atomic Energy Agency RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY Part 19.04: Optimization of protection in Mammography.
IAEA International Atomic Energy Agency General Radiography Radiation Sources in medicine diagnostic Radiology Day 7 – Lecture 1(1)
TE-MPE-CP, RD, LHC risk review 06-Mar R. Denz TE-MPE-CP Radiation Hardness of Cold By-pass Diodes Acknowledgements: D. Hagedorn (former project.
DESCRIPTION OF PIXIRAD  The PIXIRAD Imaging Counter is an INFN-Pisa Spin-off  It works in photon counting  Pulse discrimination with two thresholds.
Basis of Mammography F. Milano Dept. Clinical Physiopathology University of Florence
Equalization of Medipix2 imaging detector energy thresholds using measurement of polychromatic X-ray beam attenuation Josef Uher a,b, Jan Jakubek c a CSIRO.
NEWS FROM MEDIPIX3 MEASUREMENTS AND IMPACT ON TIMEPIX2 X. Llopart CERN.
Attività WP8: sviluppo sistema dosimetrico INFN Firenze M. Bruzzi, M. Bucciolini, E. Pace, M. Scaringella, C. Talamonti, M. Zani, A. Baldi.
M. Bruzzi, Sviluppo di sistemi di rivelazione a silicio per imaging con protoni e dosimetria Sviluppo di sistemi di rivelazione a silicio per imaging con.
Protect, Enhance, and Save Lives Characterization of a new Photon counting Detector with XRF (X-ray fluorecense) Francesca Bisello, IBA-Dosimetry.
CONFIDENTIAL MATERIAL Michele Togno - II Annual ARDENT Meeting, Milan – October, 14 th D Ionization Chambers Array for Clinical Applications.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
IEAP – CTU Prague Measurement of neutron flux during irradiation in NPI Řež T. Slavíček, V. Linhart, S. Pospíšil Institute of Experimental and Applied.
0 Ion Beam Facilities at KOMAC Chan Young Lee on behalf of KOMAC Chan Young Lee on behalf of KOMAC ICABU2014, November 12~14,
Francesca Bisello Dosepix Midterm Review Preparatory Meeting ARDENT Project June 13th, CERN.
1 /28 LePIX – Front End Electronic conference – Bergamo 25 May 2011 – Piero Giubilato LePIX – monolithic detectors in advanced CMOS Collection electrode.
Radiation Tolerance of a 0.18 mm CMOS Process
M. C. Veale1, S. J. Bell1,2, D. D. Duarte1,2, M. J. French1, M
High-Z sensor materials on Medipix3RX
Compact readout unit for the EP-RADMON radiation monitoring sensors
Characterization of a Pixel Sensor for ITK
The Pixel Hybrid Photon Detectors of the LHCb RICH
Forward-bias operation of FZ and MCz silicon detectors made with different geometries in view of their applications as radiation monitoring sensors J.
Readout Electronics for Pixel Sensors
Readout Electronics for Pixel Sensors
Effects of tube voltage, filtration, and dose rate on the color difference of the indicator. Effects of tube voltage, filtration, and dose rate on the.
Presentation transcript:

Protect, Enhance, and Save Lives III ARDENT Annual Workshop 29/09-02/10/2014 IBA Dosimetry Francesca Bisello ESR 10

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments I. Research Activities II. Conferences III. Trainings and Secondments Outline

Protect, Enhance, and Save Lives Research Activities

Protect, Enhance, and Save Lives Dosepix Characterization General overview Outline Research Activities Conferences Training and Secondments  Dosepix detector as Quality Assurance tool in diagnostics

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization kVp-meter in mammography

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments October 2013 – October 2014: Dosepix as kVp-meter in mammography Radiation Tolerance studies Temperature characterization Dosepix Characterization Sum up of activities

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization kVp-meter in mammography o Image quality and dose depend on the xRay tube voltage Tube setting: 30 kV, 20 mAs Mo-Mo Big Pixels Tube setting: 30 kV, 20 mAs Mo-Mo

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization kVp-meter in mammography o kVp: fitting the end point of the spectrum Additional filtration: 0.3mm Cu Counts/big pixel/s: 1.5 · 10 4 Hz [ count rate without filtration : 5· 10 4 Hz ]

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization RadiationTolerance studies 10-28/02/2014 Secondment at CERN Radiation Tolerance Studies Measurement Session: Accumulated dose for the test: 5 kGy in step of 200 Gy Tube settings: 40 kV, 2 mA dose rate 4.83 Gy/min

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization Radiation Tolerance studies

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization Radiation Tolerance studies  Poster Presention IEEE 2014, 8-15 November 2014 “Investigation on the radiation tolerance of Dosepix detector” F. Bisello, W.S. Wong, E.Frojdh, J.Alozy I. Ritter, A.Zang, M. Campbell, J.C.Celi, G.Anton and T.Michel o Deeper analysis of effect around mammographic energies o Investigations in damages in the sensor or in the chip

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization Temperature Characterization First Measurement Session: CERN (secondment) Addidtiona Investigations: IBA Dosimetry Measurement Session: Range required by the regulation: 15°- 35 °C Instability < 1%

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization Temperature Characterization

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization Temperature Characterization Source of instability (I): PLL circuit Source of instability (II): Bias current of initial gain stage of the discriminator

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Dosepix Characterization Temperature Characterization Next steps: o Evaluate the possibility to bypass the PLL circuit o Find other more stable configurations for the analog front end

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Other Activities SFD diodes Machine and Plan QA Small Field external Radiotherapy

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Other Activities SFD diodes Studies on sensitivity dependence from: Dose Dose per pulse Dose rate

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Other Activities SFD diodes  Oral Presentation, RESMDD14, 8-10 October 2014 “Development of silicon monolithic arrays for dosimetry in external beam radiotherapy” F. Bisello, M. Bucciolini, M. Bruzzi, D. Menichelli, M. Scaringella, C. Talamonti, M. Zani 1,2

Protect, Enhance, and Save Lives Conference Trainings Secondments

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Conferences 2014 DPG Mainz, 25 th March 2014 Oral Presentation “Characterization of the Dosepix detector under clinical conditions ” RESMDD Florence, 8-10 October 2014 Oral Presentation “Development of silicon monolithic arrays for dosimetry in external beam radiotherapy” IEEE 2014 Seattle, 8-15 November 2014 Poster Presentation “Investigation on the radiation tolerance of Dosepix detector”

Protect, Enhance, and Save Lives Outline Research Activities Conferences Training and Secondments Planned Training and Secondments Business and Administration training, ST Microelectronics Secondment at the UPENN University Hospital, Phyladelphia (tentative: November 2014):  Measurements on plan QA with silicon monolithic array  Trainings on clinical quality assurance routine (to be defined)

Protect, Enhance, and Save Lives Thank you very much for your attention