Variable Frequency Drives and Irrigation Pumps Stefanie Aschmann Bozeman, MT 11/30/11 1.

Slides:



Advertisements
Similar presentations
Siemens Building Technologies Building Technologies Variable Frequency Drives Harmonics Overview.
Advertisements

Cooling System Get the engine up to optimum operating Temperature as quickly as possible and maintains it at that temperature. Controls the heat produced.
Variable Frequency Drives VFD Basics
Chapter 33 Charging System Fundamentals.
DRIVE THE WATER CYCLE January 10 TH DRIVE THE WATER CYCLE.
APPLICATION OF MOTORS TO ADJUSTABLE FREQUENCY DRIVES PART 1 Alan Lowe, Senior Electrical Consultant.
Application Types Variable Torque Constant Torque.
12/3/2002BAE Electric Motors Classification / types –DC Motors –AC Motors –Stepper Motors –Linear motors Function –Power conversion - electrical.
Electro Mechanical System
PENTAIR 1.
Power Engineering Society Chicago Chapter Reactive Power: Sources and Solutions 12 February 2003 David E. Mertz, PE Burns & McDonnell Engineers, Inc.
Irrigation Energy options and considerations January 23, 2008 Lyndon Kelley MSU Extension/Purdue University Irrigation Management Educator.
The Centrifugal Pump.
WISA Meeting Help Arrange a Speaker, Write Bio, Introduce
7154/7156 Variable Speed Drives
Course Coordinator Prof. Suneet Tuli Presented by- Rupali Gupta (2012TTE2398) M.Tech 1 st Year Textile Engineering.
Charging System Fundamentals
© Goodheart-Willcox Co., Inc. Permission granted to reproduce for educational use only Publisher The Goodheart-Willcox Co., Inc. Tinley Park, Illinois.
Engine Size and Measurements
1.4b Charging System 1. Charging System Function of the charging system 2 Convert mechanical energy into electrical energy Recharge battery Provide higher.
Chapter 22 Alternating-Current Circuits and Machines.
Considerations for Selecting VFD’s Quentin Nesbitt, PE Agricultural Engineer Idaho Power Company.
Where We Go Wrong In Pump Design Dick Hawrelak Presented to ES317Y in 1999 at UWO.
New England Association Of Fire Protection System Designers Rick Dumont.
TEAM UP! FOR FAN AND PUMP SAVINGS It can be as easy as replacing an old drive belt.
7154 VFD Presentation #2 May 2002 Paul Weingartner.
Energy conversion and storage Some energy sources have storage ‘built in’ Fossil fuels Biofuels Hydro power (to some extent) Others are available on demand.
Motor Testing (Motor Only)
CHARGING SYSTEM Major Parts Battery                                               Alternator Regulator.
Chapter 19 AC Motors.
Forging new generations of engineers. DC Motors and Generators Instruction Plan.
Metso - Slurry Pumping.
PRINCIPLES OF OPERATION
1 Motors and Generators ©Dr. B. C. Paul More Fun with Flux Mechanically Rotated Shaft Slip Rings Wires with brush contacts to slip rings Electromagnetic.
Understanding the                                                                                                                                                                                                                          
Blowers, Motors and Belts. This power point presentation will review Section C2 in the Student Handout Packet. You may also need to refer back to the.
Chapter 16: Synchronous Generators
HYDRAULIC MOTORS.
Motors and Generators.
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
1 ME444 ENGINEERING PIPING SYSTEM DESIGN CHAPTER 6 : PUMPS.
POWER ELECTRONICS IN SHIP PROPULSION ELECTRIC MOTORS.
INTRODUCTION TO ROBOTICS Part 3: Propulsion System Robotics and Automation Copyright © Texas Education Agency, All rights reserved. 1.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
Prepared By Rohit G. Sorte M.Tech
PRESENTED BY : JESTY JOSE – JOBIN ABRAHAM – SAGAR JAISWAL – DANISH KHATRI
CLOSED LOOP SPEED CONTROL OF DC MOTOR WITH PWM TECHNIQUE
 2008 Kaeser Compressors, Inc., USA (V4.1) SFC Product Introduction “Specifications are subject to change without notice” 1 SFC Sigma Frequency Controlled.
ENERGY CONSERVATION IN MOTOR SYSTEMS. Introduction 2.
6/30/2016EMC: AC Motors Roger Enns1 AC 6/30/2016EMC: AC Motors Roger Enns2 AC Motors Summary.
INDUCTION GENERATOR FOR WIND POWER GENERATION
Review of ABB Drives. 1.Direct torque control explains what DTC is; why and how it has evolved; the basic theory behind its success; and the features.
Automation and Drives A&D SD Customer Service & Support A&D SD CST 23/11/04 1 of 14 10A MotorTheory.ppt Motor Theory Motor Construction Motor Theory Drives.
Energy Efficient Motors and Variable Speed Drives
DC Generators.
Speed control of three phase induction motor
Topics covered in this presentation:
Introduction to Electrical Drive
Electric Machine Induction Motor
SPOC Automation and BECI- who are we?
Electric Motors.
ME444 ENGINEERING PIPING SYSTEM DESIGN
Why is starter necessary for a three-phase induction motor?
Robicon Perfect Harmony.
MOTOR SELECTION Electric motors should be selected to satisfy the requirements of the machines on which they are applied without exceeding rated electric.
Induction Motor Drives
AC Drives Dr. Adel A. El-Samahy Department of Electrical Engineering University of Helwan.
Electric Machine Design Course
Presentation transcript:

Variable Frequency Drives and Irrigation Pumps Stefanie Aschmann Bozeman, MT 11/30/11 1

Variable Frequency Drives Overview of draft “Variable Frequency Drives for Irrigation Pumping” TechNote ftp://ftp.wcc.nrcs.usda.gov/wntsc/Idaho%20pump%20Training/

Variable Frequency Drives Introduction VSD vs. VFD How VFD’s work Applications Operation/Design Considerations VFD Tool Demonstration

Variable Frequency Drives Pumping water for irrigation can be a major expense for irrigated farms. In 2008 more than 570,000 pumps were used for irrigation $15.5 billion dollars spent on energy Efficiency is a big issue “For the most part, the enormous cost of inefficient pump operation and valve throttling goes unnoticed”

There are several ways to vary the speed of a pump. Not all save energy.  Electrical (variable speed motor using variable frequency drive, or VFD – most common) Mechanical (diesel and gasoline engines) Hydraulic (hydraulic coupling) Variable speed pulley arrangements Changeable gearbox Magnetic coupler Variable Frequency Drives are a subset of Variable Speed Drives

Variable Frequency Drives Variable Frequency Drives are used exclusively on devices that have electric motors. The frequency used in the term refers to the frequency of the electrical current. In the US, electrical grid power has a frequency of 60 Hz.

Think about your ride Tachometers (or rev counters) on automobiles, aircraft, and other vehicles show the rate of rotation of the engine's crankshaft.

Variable Frequency Drives Pump speed (e.g rpm, or 1175 rpm) refers to the rotational speed of the impeller. The motor shaft is connected to the impeller; the impeller adds energy to the water. Slowing the rotation of the impeller reduces the energy that is transferred to the water and thereby the power requirement of the pump.

Slide 10

What does changing the frequency do? The speed of an alternating current (AC) motor depends on three principal variables: The fixed number of winding sets (known as poles) built into the motor, which determines the motor's base speed. The frequency of the AC line voltage. The third variable is the amount of torque loading on the motor, which causes slip.

What does changing the frequency do? It allows us to change the rotational speed of the pump’s impeller. Changing the speed of the impeller has the same effect as changing the diameter of the impeller: It shifts the pump curve (usually down)

Why Variable Frequency Drives? Pumps often need to operate over a range of flow rates and pressure Pump is designed to meet the greatest output for both flow and pressure At other flows/pressure, the pump will be inefficient

Pump Curve

Getting to Where We Want to Be Often the pump operator will change the system curve to get to where they want to be.

Original Operating Point New Operating Point

Original Operating Point New Operating Point

Variable Frequency Drives

Constant Pressure//Variable Flow Constant Flow//Variable Pressure Variable flow//Variable Pressure Applications

Variable Frequency Drives Constant Pressure//Variable Flow Example Constant Pressure//Variable Flow Example 3 center pivots running off one pump. Each pivot requires the same pressure. But the operator wants to be able to run 1, 2 or 3 pivots at the same time. The VFD maintains the pressure by shifting the pump curve, thereby increasing or decreasing the flow.

Variable Frequency Drives Applications Constant Pressure//Variable Flow Constant Flow//Variable Pressure Variable flow//Variable Pressure

Variable Frequency Drives Constant Flow//Variable Pressure Example A well that experiences drawdown over the course of the irrigation season Want constant flow rate throughout the season.

Variable Frequency Drives

Variable Pressure/Variable Flow Example Multiple systems of wheel lines and pivots

Variable Frequency Drives

VFD Operation Considerations Installing a VFD for power savings Motor load below 60%, electric motor becomes inefficient VFD itself is about 97% efficient Soft Start Option Single to 3 Phase Conversion Automation Open delta current balancing

What are VFD’s potential problems? Additional losses – heat, motor loading, etc. VFD systems may create electric power system harmonics (harmonic currents are caused by certain types of equipment that draw current intermittently while running ). Operation of pumps at critical shaft speeds, far from design (BEP), can result in deflection & shaft failure Pump bearings and seals may wear faster at higher or lower shaft speeds Slide 27

VFD potential problems (continued) Too much capacity that can burn out the motor. Explosion proof motors must be approved to operate over the entire operating range. At the lower rpms the cooling fan is not rotating fast enough. Mechanical seals must be designed to operate over the entire speed range. High shaft speeds lead to additional NPSH requirement to prevent cavitation. Slide 28

Sizing In the design process, the size of the VFD needs to account for all inherent drive inefficiencies the motor load including service factor. Drive size may also be increased to minimize, voltage distortion and interference with other electrical equipment. Almost double is needed when converting single to three phase Care should also be taken to not select a VFD too large as the VFD output might exceed motor specifications and cause motor failure. Slide 29

Motor load Slide 30

Motor insulation class

Filters Line filters may be required for VFD’s to regulate voltage. Imbalance in voltage generates more heat and loss of efficiency in the VFD and motor. The EMI and RFI generated by the installation should be measured. If the interference exceeds limits defined by the current IEEE 519, electric utility may require that filters be installed.

Environmental Control An increase in temperature will see a dramatic drop in VFD efficiency and may require installation of a cooling mechanism. External Heat Sinks Self-Contained Cooling Systems

Environmental Control VFD’s cannot tolerate dust or dampness; Should be installed in enclosures that meet NEMA 4 standards (dust & water tight). Adequate sunshades or pump houses are required for all installations.

Environmental Control Other factors that may affect VFD efficiency are. Radio frequency or stray high frequency signals. Line voltage variation greater than ±10%. Line frequency variation greater than ±2Hz. Altitude greater than 3,300 feet (1000 meters)

VFD Tool Demonstration Case No. 3 (see handout)