Detectors and Preamplifiers Detector deliveries Customer Acceptance Tests Available detectors AGATA triple detectors Scanning program P. Reiter IKP University.

Slides:



Advertisements
Similar presentations
The AGATA Project First 4pi -ray spectrometer built completely from Germanium detectors. Based on the novel technique of gamma-ray tracking. Measures radiation.
Advertisements

Călin A. Ur* for the AGATA Collaboration INFN – Sezione di Padova
Nuclear Structure with Gamma-ray Tracking Arrays
Detector Characterisation Group
Advanced GAmma Tracking Array
Alberto Pullia INFN - Milano University of Milano Department of Physics 12th AGATA Week June 11-13, 2012, GSI, Germany June 13, 2012 Status of the AGATA.
AGATA Introduction John Simpson Nuclear Physics Group.
Purpose: Integration of AGATA detectors in triple modules Acceptation tests of triplets (energy resolution, crosstalk,…) Complementing the scanning table.
Results on Test Cryostats and The AGATA Asym. Triple: Status of Cryostat Production AGATA Detector Group Meeting, IKP Cologne March 16th, 2006.
TRD Collaboration Meeting GSI Clemens Adler TRD Chamber production issues General Issues, Planning and Hd Status.
First complete test measurements of the AGATA Core _ Pulser Assembly. AGATA Core Pulser, Segments Bulk Capacitances (First measurements of the Pulser Core.
University of Milano Department of Physics and INFN HIGH DYNAMIC RANGE LOW-NOISE PREAMPLIFICATION OF NUCLEAR SIGNALS A. Pullia, F. Zocca, C. Boiano, R.
AGATA Core - upgraded front end electronics
RlRl A R fb C fb C ac +Bias A R fb C fb A R bf C fb v0v0 v1v1 v2v2 V 0,out V 1,out V 2,out A simple detector model to describe crosstalk in segmented detectors.
Science Specification Table 12 keV keV for neutral particles 40.5 cm 2 image plane Electronic Noise 3 keV FWHM Proton Dead Layer
Depletion Region Dynamics of an AGATA Detector Steven Moon University of Liverpool UNTF 2010, University of Salford 14 th -16 nd April 2010.
WP1: Detector Assembly Liverpool Tasks:  Detector specification measurement Assembly of components in progress  Detector assembly for scanning Work in.
TRACKING TEAM Introduction What has been done What still needs to be done.
AGATA: Advanced Gamma Tracking Array
AGATA 2 nd Prototype Detector Initial Measurements & Evaluation Andrew Boston, Matthew Dimmock, Laura Nelson, Sarah Rigby.
Characterisation & PSA Team Meeting Presentations –Liverpool Status, Andy Boston/Matt Dimmock (Liverpool) –Crosstalk properties of AGATA detectors, Bart.
Brief Report on the Status of the AGATA Project (June 2012) A. Gadea (IFIC, Valencia) the AGATA PM on behalf of the AMB AGATA Collaboration Council Orsay.
N. Redon AW Uppsala July Proposal for a commissioning experiment with the AGATA Demonstrator Proposal for a commissioning experiment with the AGATA.
John Simpson Nuclear Physics Group Daresbury Laboratory The AGATA project NUSTAR ’05 University of Surrey January 2005.
AGATA: Advanced Gamma Tracking Array
AGATA Pre-processing team report AGATA Week, July 2008.
Status of the AGATA Project June 2013 on behalf of the AMB AGATA Collaboration Council meeting June 2013.
Wolfram KORTEN, JRA-02 AGATA Irfu AGATA week, Orsay (France), January 15-18, 2007 AGATA within EURONS Objectives: Development, construction, commissioning.
Wolfram KORTEN, JRA-02 AGATAEURONS PCC-Meeting, Mainz (Germany), April 2006 Status of the AGATA project Recent developments Milestones and deliverables.
On the origin of Differential Crosstalk in segmented detectors B. Bruyneel for the AGATA week, Uppsala, Sweden July 2008.
Analysis of S002 scan data Bart Bruyneel and Benedikt Birkenbach – IKP Cologne At the 7 th AGATA week, Uppsala July S003.
 -tracking uses segmented detectors which are characterized by xTalk  Traces are modified in shape and amplitude  Energy effects: peak shifts and resolution.
Observing ion cyclotron waves M. R. Lessard, M. Widholm, P. Riley, H. Kim M. J. Engebretson University of New Hampshire Augsburg College NSF Workshop on.
AGATA Week Introduction John Simpson Nuclear Physics Group GSI, February 2005.
Lund Lund York Cologne Calorimeter present status test results with Thanks to Andreas Wendt !!
Véronique SANGLARD Université de Lyon, UCBL1 CNRS/IN2P3/IPNLyon Status of EDELWEISS-II.
Ge Test-stands at MPI Munich Xiang Liu 1.General 2.Crystals, Test-stands & Results 3.Outlook.
Development of a Segmented Planar Germanium Imaging Detector
LAV construction status – M. Moulson (Frascati) – Photon Veto WG – CERN – 12 Jul 2011 LAV construction status: a snapshot 2 A1 Arrived at CERN 29 Jun.
Gain stability and the LYSO beam radiation monitor measurements
 Digitisation P.Medina  Pre-processing I.Lazarus GTSM.Bellato GTSM.Bellato  PSA P.Desesquelle R.Gernhäuser 7 th AGATA Week, Uppsala, July 8-11, 2008.
Alberto Pullia INFN - Milano University of Milano Department of Physics 14th AGATA Week January 22-24, 2014, Madrid, Spain January 23, 2014 Status of the.
1 AGATA – Ch. VEYSSIERE 09/07/2008 A. BOUTY; S. BROUSSARD; A. LOTODE; Y. MARIETTE; Ch. VEYSSIERE: CEA/DSM/IRFU/SIS D. BAZZACCO: Univ. Padova E. FARNEA;
Detector Module Three 36-fold segmented detectors 111 preamplifiers Cryostat Jürgen Eberth University of Cologne Detector Team: Dirk Weißhaar Preampl.
Tile HCAL status Felix Sefkow CALICE Technical Board Review April 19, 2007.
PSA: ADAPTIVE GRID SEARCH The Method Experimental Results Optimization aspects Roberto Venturelli (INFN Padova - IPSIA “Giorgi” Verona) SACLAY, 05-may-06.
D0 PMG, May 04, 2000 Slide 1 Schedule DØ SMT Status Report.
AGATA Detector Meeting March 16th, 2006, Cologne Detector Acceptance Tests: delivered: three symmetric detectors S001 properties excellent S002 properties.
KIT - The cooperation of Forschungszentrum Karlsruhe GmbH and Universität Karlsruhe (TH) Florian Fränkle EPS HEP 2009 Krakow 1 KATRIN: An experiment to.
T HE PDM INTEGRATION P. Barrillon (LAL) & G. Prévôt (APC) On behalf of the PDM crew (Simon, Lech, Philippe, Sylvie B) EUSO-SPB/MiniEUSO progress meeting,
Recent progress in ultra-low noise, ultra-low background detectors V. Marian, M.O. Lampert, B. Pirard, P. Quirin CANBERRA France (Lingolsheim) Workshop.
SOLEIL OPERATION AND ON-GOING PROJECTS C. Herbeaux On behalf of SOLEIL Groups C. Herbeaux, November ESLS23, 24-25, 2015, PSI1.
Neutrinoless double beta decay (0  ) CdTe Semico nductor Band gap (eV) Electron mobility (cm 2 /V/s) Hole mobility (cm 2 /V/s) Density (g/cm 3.
Advanced Gamma Tracking Array Andy Boston The Advanced Gamma Tracking Array
1st PSeGe Workshop, IPNO & CSNSM Orsay 3rd -4th October 2016
Detector characterization overview of the AGATA scanning tables
Detectors and Preamplifiers
Status of the AGATA installation at GANIL
THEMIS INSTRUMENT SUITE
AGATA Detector Work Performed at Saclay in lessons learned -
Status of the AGATA installation at GANIL
CAT of AGATA detectors &
AGATA Construction Database
SIGMA: a detector for γ-ray spectroscopy & imaging Dr Laura AGATA/GRETINA Collaboration Meeting
Preliminary Compton Imaging results of the AGATA C001 detector
On the origin of Differential Crosstalk in segmented detectors
AGATA week Uppsala, July 2008
Status report Detector team
SDD status E17 meeting 27/Aug./2009.
SAME 15 existing quadrupoles (QFS, QDS, QFL)
Presentation transcript:

Detectors and Preamplifiers Detector deliveries Customer Acceptance Tests Available detectors AGATA triple detectors Scanning program P. Reiter IKP University Cologne AGATA week 8-11 July 2008 Uppsala

DetectorDeliveryOwnerStatus A001*11/2005GANILrejected – hole trapping A00106/2006GANILaccepted A002*04/2006TU Munichrejected – leakage currents A00206/2007TU Munichaccepted A003*11/2006Liverpoolrejected – leakage currents A00310/2007Liverpoolaccepted A00409/2007Ankararejected – segments out of specification A004*07/2008AnkaraCAT at IKP, Cologne A00512/2007StockholmCAT at CEA, Saclay & IKP B001*11/2005Padovarejected – segments out of specification B00106/2007Padovarejected – leakage currents B00208/2006GANILaccepted B00306/2007Liverpoolaccepted B00412/2007Ankararejected – missing segment in capsule B004*06/2008AnkaraCAT at IKP, Cologne B00512/2007StockholmCAT at CEA, Saclay C00112/2005Padovaaccepted C00207/2006GANILaccepted C00303/2007Liverpoolaccepted, broken, leakage currents C00409/2007Ankaraaccepted C00512/2007StockholmCAT at CEA, Saclay

DetectorDeliveryOwnerStatus A00106/2006GANILAccepted, available A00206/2007TU MunichAccepted, available A00310/2007LiverpoolAccepted, available B00208/2006GANILAccepted, available B00306/2007LiverpoolAccepted, available C00112/2005PadovaAccepted, available C00207/2006GANILAccepted, available C00409/2007Ankaraaccepted

Recent detector tests and future deliveries Turkish detectors B004 (repaired) delivered to IKP, Cologne, test started A004 (repaired) delivered July, 1st 2008 shipment of A004, B004, C004 to Turkey autumn 2008 Swedish detectors A005, B005, C005 tests ongoing at CEA - test results of A005 to be confirmed at IKP, Cologne - test of B005 started Liverpool detector C003: leakage current, out of warranty Italian detectors A006 announced delivery July (week 29) 2008 B006 announced delivery July (week 31) 2008 B001 announced delivery July 2008

Summary available detector 8 detectors accepted (A1,A2,A3 B2,B3 C1,C2,C4) 1 detector to be repaired at Canberra (B1) 5 detectors ongoing test (A4, A5, B4, B5, C5) 1 detector broken (C3) (Sweden A005, B005, C005) ongoing CAT at Saclay 2 (Turkey A004, B004) ongoing CAT at Cologne 1 (Italy C001) scanning at Liverpool until July 1 (Italy B001) not accepted after CAT, not repaired 1 (UK C003) is broken after CAT, needs repair 3 (Turkey A004, B004, C004) are shipped to Turkey fall At the moment 6 detectors are available for AGATA triple clusters A001, A002, A003 B002, B003 C002

AGATA triple cluster detectors First AGATA triple * A001 : B002 : C002 : *Goes to Legnaro July 2008 First AGATA triple * A001 : B002 : C002 : *Goes to Legnaro July 2008 Second AGATA triple A003 : B003 : C004 : * *Goes to Turkey in fall 2008, Replaced by C005 Second AGATA triple A003 : B003 : C004 : * *Goes to Turkey in fall 2008, Replaced by C005 Third AGATA triple A002 : B005 or B001: * C001: ** *B005 after test or B001 after delivery & test ** C001 after scanning Third AGATA triple A002 : B005 or B001: * C001: ** *B005 after test or B001 after delivery & test ** C001 after scanning

Scanning program Liverpool C001 * A005 * Goes to IKP, Assembly of second Triple cluster by CTT July 2008 Liverpool C001 * A005 * Goes to IKP, Assembly of second Triple cluster by CTT July 2008 Orsay S002 * B005 : * Commissioning, confirm Liverpool results Orsay S002 * B005 : * Commissioning, confirm Liverpool results See talks by A. Boston C. Unsworth A. Korichi F. Crespi Thursday, 14:00-15:40

Future detector tests and triple assembly Detectors for period fall and winter 2008/09 13 detectors may be available A1, A2, A3, A5, A6 B1, B2, B3, B5, B6 C1, C2, C5 A6, B1, B6 delivery July 2008 redelivery of turkish detectors A4, B4, C4 ? January - June 2009 italian detectors C6, A7 ? detector repair of C3 ? summer 2008 order of german detectors A8, B7, C7 ?

Talks by A. Wiens, IKP Cologne A. Goergen, CEA Saclay D. Quirion, Canberra B. Bruyneel, IKP Cologne G. Pascovici, IKP Cologne

1 st Tripel Cluster Energies: Single vs Triple cryostat A001 – FWHM [keV] B002 – FWHM [keV] C002 – FWHM [keV] Resolution 60keV line Resolution 1.33MeV line

2 nd Tripel Cluster Energies: Single vs Triple cryostat A003 FWHM [keV] C004 FWHM [keV] B003 FWHM [keV] A003 FWHM [keV] Resolution: 60keV line

Tripel Cluster Energy resolution: Single vs Triple cryostat Excellent energy resolution in two AGATA triple clusters Mean values 60 keV : especially at low energies (electronic noise): - glued detectors  less microphonics - HEKO  AGATA preamp - electronic assembly (grounding, cabling) First AGATA triple A001 : /- 53 eV B002 : /- 70 eV C002 : 965 +/- 63 eV First AGATA triple A001 : /- 53 eV B002 : /- 70 eV C002 : 965 +/- 63 eV Second AGATA triple A003 : /- 65 eV B003 : 995 +/- 73 eV C004 : /- 104 eV * Second AGATA triple A003 : /- 65 eV B003 : 995 +/- 73 eV C004 : /- 104 eV * * high frequency oscillation to be removed

Cross talk measurements A2..A6 B1 F1 Core to seg Xtalk = understood! Segment labeling: Sectors: A...F Rings: X Bart Bruyneel, Andreas Wiens

Smallest capacities in ring 2 A2 B2 C2 D2 E2 F2

Cross talk in first AGATA Triple Cryostat A001 B002 C002 Core BCore C Core ACore C Core ACore B Sector ASector F Sector ASector F Sector ASector F A001 B002 C002

AGATA Triple Clusters: Summary & outlook Two AGATA Triple Cluster Detectors operational: - first & second triple: cryostat, mechanics, vacuum, thermal properties of preamps o.k. - seg-preamps, core preamps & pulser with high dynamic range operational - very good energy resolution at low energies - no cross talk between detectors observed in 1 st ATC between detectors - commissioning of 2 nd ATC ongoing Next steps: - transport of 1st ATC to Legnaro, first tests with digital electronics at Legnaro July finish commissioning of 2nd ATC, - cross talk tests - - assembly of 3rd ATC constrained by - available detectors ATC1 ATC2 ATC3