Speckle Correlation Analysis1 Adaptive Imaging Preliminary: Speckle Correlation Analysis.

Slides:



Advertisements
Similar presentations
Noise in Radiographic Imaging
Advertisements

Bayesian Belief Propagation
A Crash Course in Radio Astronomy and Interferometry: 2
EE359 – Lecture 8 Outline Capacity of Fading channels Fading Known at TX and RX Optimal Rate and Power Adaptation Channel Inversion with Fixed Rate Capacity.
Air Force Technical Applications Center 1 Subspace Based Three- Component Array Processing Gregory Wagner Nuclear Treaty Monitoring Geophysics Division.
Object Specific Compressed Sensing by minimizing a weighted L2-norm A. Mahalanobis.
Foundations of Medical Ultrasonic Imaging
1 Small-scale Mobile radio propagation Small-scale Mobile radio propagation l Small scale propagation implies signal quality in a short distance or time.
7. Radar Meteorology References Battan (1973) Atlas (1989)
Collaboration FST-ULCO 1. Context and objective of the work  Water level : ECEF Localization of the water surface in order to get a referenced water.
Ultrasonic Nonlinear Imaging- Tissue Harmonic Imaging.
BMME 560 & BME 590I Medical Imaging: X-ray, CT, and Nuclear Methods Tomography Part 3.
Lecture 39 Spatial Coherence and Holography Honors talks this evening….
1 Mobile Communication Systems 1 Prof. Carlo Regazzoni Prof. Fabio Lavagetto.
Image Enhancement in the Frequency Domain Part I Image Enhancement in the Frequency Domain Part I Dr. Samir H. Abdul-Jauwad Electrical Engineering Department.
Ultrasound Imaging Atam Dhawan.
Ultrasonic Nonlinear Imaging- Tissue Harmonic Imaging
EEE440 Modern Communication Systems Wireless and Mobile Communications.
PHY 102: Waves & Quanta Topic 8 Diffraction II John Cockburn Room E15)
Chapter 4 Mobile Radio Propagation: Small-Scale Fading and Multipath
Despeckle Filtering in Medical Ultrasound Imaging
THE ULTRASOUND IMAGE: GENERATION AND DISPLAY
Doppler Radar From Josh Wurman Radar Meteorology M. D. Eastin.
Ultrasonography.
Review Doppler Radar (Fig. 3.1) A simplified block diagram 10/29-11/11/2013METR
1 Ultrasonic Elasticity Imaging. 2 Elasticity Imaging Image contrast is based on tissue elasticity (typically Young’s modulus or shear modulus).
Chapter 36 In Chapter 35, we saw how light beams passing through different slits can interfere with each other and how a beam after passing through a single.
Wireless Communication Technologies 1 Outline Introduction OFDM Basics Performance sensitivity for imperfect circuit Timing and.
The Wireless Channel Lecture 3.
Advanced Imaging 1024 Jan. 7, 2009 Ultrasound Lectures History and tour Wave equation Diffraction theory Rayleigh-Sommerfeld Impulse response Beams Lecture.
Adaptive Imaging Preliminary: Speckle Correlation Analysis.
Display of Motion & Doppler Ultrasound
Review of Ultrasonic Imaging
Sarah Gillies Ultrasound Sarah Gillies
1 What is small scale fading? Small scale fading is used to describe the rapid fluctuation of the amplitude, phases, or multipath delays of a radio signal.
Adaphed from Rappaport’s Chapter 5
Light Wave Interference In chapter 14 we discussed interference between mechanical waves. We found that waves only interfere if they are moving in the.
Digital Beamforming. Beamforming Manipulation of transmit and receive apertures. Trade-off performance/cost to achieve: –Steer and focus the transmit.
Chapter 6: Real-Time Image Formation. display B, M, Doppler image processing Doppler processing digital receive beamformer system control keyboard beamformer.
Interference and Diffraction
Discrete-time Random Signals
Outline Transmitters (Chapters 3 and 4, Source Coding and Modulation) (week 1 and 2) Receivers (Chapter 5) (week 3 and 4) Received Signal Synchronization.
3.38. Diffraction Diffraction is a scale phenomenon that can only be described by use of waves. Consider a plane wave front of wavelength incident on an.
RADAR ANTENNA. Functions of Radar Antenna Transducer. Concentrates the radiated energy in one direction (Gain). Collects echo energy scattered back to.
1 EMLAB EM wave propagation. 2 EMLAB Impulse response Time Radio Propagation : physical model 안테나에서 나온 신호는 지형지물과 반사, 투과, 산란을 거치면서 다양한 진폭과, 시간 지연을 갖는 신호들로.
EEE 441 Wireless And Mobile Communications
NUR INANI BINTI MOHD RUZLAN A Tissue harmonic imaging is a technique in ultrasonography that provides images of better quality as compared to conventional.
Linear systems: University of Illinois at Chicago ECE 427, Dr. D. Erricolo University of Illinois at Chicago ECE 427, Dr. D. Erricolo Consider two complex.
1 Opto-Acoustic Imaging 台大電機系李百祺. 2 Conventional Ultrasonic Imaging Spatial resolution is mainly determined by frequency. Fabrication of high frequency.
Chapters 36 & 37 Interference and Diffraction. Combination of Waves In general, when we combine two waves to form a composite wave, the composite wave.
Mobile Radio Propagation - Small-Scale Fading and Multipath
Biointelligence Laboratory, Seoul National University
Shadowing.
Doppler Spectral Analysis
Statistical Multipath Channel Models
Chapter 35-Diffraction Chapter 35 opener. Parallel coherent light from a laser, which acts as nearly a point source, illuminates these shears. Instead.
Lecture on Ultrasonography
UNIT-III Signal Transmission through Linear Systems
Degradation/Restoration Model
Outline Introduction Signal, random variable, random process and spectra Analog modulation Analog to digital conversion Digital transmission through baseband.
Advanced Wireless Networks
Volume 94, Issue 1, Pages (January 2008)
Optical Coherence Tomography
Light Through a Single Slit
Chapter 36 In Chapter 35, we saw how light beams passing through different slits can interfere with each other and how a beam after passing through a single.
Review of Ultrasonic Imaging
Fourier Optics P47 – Optics: Unit 8.
Unit 2 Particles and Waves Interference
Ultrasonic Imaging Using Contrast Agents
Presentation transcript:

Speckle Correlation Analysis1 Adaptive Imaging Preliminary: Speckle Correlation Analysis

Speckle Correlation Analysis2 Speckle Formation Speckle results from coherent interference of un- resolvable objects. It depends on both the frequency and the distance. sample volume transducer

Speckle Correlation Analysis3 Speckle Second-Order Statistics The auto-covariance function of the received phase-sensitive signals (i.e., before envelope detection) is simply the convolution of the system’s point spread function if the insonified region is –macroscopically slow-varying. –microscopically un-correlated.

Speckle Correlation Analysis4 Speckle Second-Order Statistics The shape of a speckle spot (assuming fully developed) is simply determined by the shape of the point spread function. The higher the spatial resolution, the finer the speckle pattern, and vice versa.

Speckle Correlation Analysis5 Speckle Statistics The above statements do not hold if the object has structures compared to or larger than the ultrasonic wavelength. Rician distribution is often used for more general scatterer distribution. Rayleigh distribution is a special case of Rician distribution.

Speckle Correlation Analysis6 Lateral Speckle Correlation correlation coefficient displacement L/2

Speckle Correlation Analysis7 Lateral Speckle Correlation Assuming the target is at focus, the correlation roughly decreases linearly as the lateral displacement increases. The correlation becomes zero when the displacement is about half the aperture size. Correlation may decrease in the presence of non-ideal beam formation.

Speckle Correlation Analysis8 van Cittert-Zernike Theorem A theorem originally developed in statistical optics. It describes the second-order statistics of the field produced by an in-coherent source. The insonification of diffuse scatterers is assumed in-coherent. It is different from the aforementioned lateral displacement.

Speckle Correlation Analysis9 van Cittert-Zernike Theorem The theorem describes the spatial covariance of signals received at two different points in space. For a point target, the correlation of the two signals should simply be 1. For speckle, correlation decreases since the received signal changes.

Speckle Correlation Analysis10 van Cittert-Zernike Theorem The theorem assumes that the target is microscopically un-correlated. The spatial covariance function is the Fourier transform of the radiation pattern at the point of interest.

Speckle Correlation Analysis11 van Cittert-Zernike Theorem radiation pattern correlation

Speckle Correlation Analysis12 van Cittert-Zernike Theorem The theorem states that the correlation coefficient decreases from 1 to 0 as the distance increases from 0 to full aperture size. The correlation is independent of the frequency, aperture size, …etc.

Speckle Correlation Analysis13 van Cittert-Zernike Theorem In the presence of tissue inhomogeneities, the covariance function is narrower since the radiation pattern is wider. The decrease in correlation results in lower accuracy in estimation if signals from different channels are used.

Speckle Correlation Analysis14 van Cittert-Zernike Theorem distance correlation

Speckle Correlation Analysis15 Speckle Tracking Estimation of displacement is essential in many imaging areas such as Doppler imaging and elasticity imaging. Speckle targets, which generally are not as ideal as points targets, must be used in many clinical situations.

Speckle Correlation Analysis16 Speckle Tracking From previous analysis on speckle analysis, we found the local speckle patterns simply translate assuming the displacement is small. Therefore, speckle patterns obtained at two instances are highly correlated and can be used to estimate 2D displacements.

Speckle Correlation Analysis17 Speckle Tracking Displacements can also be found using phase changes (similar to the conventional Doppler technique). Alternatively, displacements in space can be estimated by using the linear phase shifts in the spatial frequency domain.

Speckle Correlation Analysis18 Speckle Tracking Tracking of the speckle pattern can be used for 2D blood flow imaging. Conventional Doppler imaging can only track axial motion. Techniques using phase information are still inherently limited by the nature of Doppler shifts.

Speckle Correlation Analysis19 Adaptive Imaging Methods

Speckle Correlation Analysis20 Sound Velocity Inhomogeneities transducer array v1 v2 v3 point of interest body wallviscera

Speckle Correlation Analysis21 Sound Velocity Inhomogeneities Velocity (m/sec) water 1484 blood 1550 myocardium 1550 fat 1450 liver 1570 kidney 1560

Speckle Correlation Analysis22 Sound Velocity Inhomogeneities Sound velocity variations result in arrival time errors. Most imaging systems assume a constant sound velocity. Therefore, sound velocity variations produce beam formation errors. The beam formation errors are body type dependent.

Speckle Correlation Analysis23 Sound Velocity Inhomogeneities Due to beam formation errors, mainlobe may be wider and sidelobes may be higher. Both spatial and contrast resolution are affected. no errorswith errors

Speckle Correlation Analysis24 Near Field Assumption Assuming the effects of sound velocity inhomogeneities can be modeled as a phase screen at the face of the transducer, beam formation errors can be reduced by correcting the delays between channels. beam formation correction geometric delay velocity variations aligned

Speckle Correlation Analysis25 Correlation Based Method Time delay (phase) errors are found by finding the peak of the cross correlation function. It is applicable to both point and diffuse targets.

Speckle Correlation Analysis26 Correlation Based Method The relative time delays between adjacent channels need to be un- wrapped. Estimation errors may propagate.

Speckle Correlation Analysis27 Correlation Based Method Two assumptions for diffuse scatterers: –spatial white noise. –high correlation (van Cittert-Zernike theorem). filtercorrelator xx

Speckle Correlation Analysis28 Correlation Based Method Correlation using signals from diffuse scatterers under-estimates the phase errors. The larger the phase errors, the more severe the underestimation. Iteration is necessary (a stable process).

Speckle Correlation Analysis29 Alternative Methods Correlation based method is equivalent to minimizing the l2 norm. Some alternative methods minimize the l1 norm. Correlation based method is equivalent to a maximum brightness technique.

Speckle Correlation Analysis30 Baseband Method The formulation is very similar to the correlation technique used in Color Doppler.

Speckle Correlation Analysis31 Baseband Method CORDIC I Q I Q acc. Q sign bitsign control

Speckle Correlation Analysis32 One-Dimensional Correction: Problems Sound velocity inhomogeneities are not restricted to the array direction. Therefore, two-dimensional correction is necessary in most cases. The near field model may not be correct in some cases.

Speckle Correlation Analysis33 Two-Dimensional Correction Using 1D arrays, time delay errors can only be corrected along the array direction. The signal received by each channel of a 1D array is an average signal. Hence, estimation accuracy may be reduced if the elevational height is large. 2D correction is necessary.

Speckle Correlation Analysis34 Two-Dimensional Correction Each array element has four adjacent elements. The correlation path between two array elements can be arbitrary. The phase error between any two elements should be independent of the correlation path.

Speckle Correlation Analysis35 Full 2D Correction (1,1)(1,3)(1,2)corr (3,1)(3,3)(3,2)corr (2,1)(2,3)(2,2)corr

Speckle Correlation Analysis36 Row-Sum 2D Correction (1,1)(1,3)(1,2)corr (3,1)(3,3)(3,2)corr (2,1)(2,3)(2,2)corr

Speckle Correlation Analysis37 Correlation Based Method: Misc. Signals from each channel can be correlated to the beam sum. Limited human studies have shown its efficacy, but the performance is not consistent clinically. 2D arrays are required to improve the 3D resolution.

Speckle Correlation Analysis38 Displaced Phase Screen Model Sound velocity inhomogeneities may be modeled as a phase screen at some distance from the transducer to account for the distributed velocity variations. The displaced phase screen not only produces time delay errors, it also distorts ultrasonic wavefronts.

Speckle Correlation Analysis39 Displaced Phase Screen Model Received signals need to be “back- propagated” to an “optimal” distance by using the angular spectrum method. The “optimal” distance is determined by using a similarity factor. phase screen

Speckle Correlation Analysis40 Displaced Phase Screen Model After the signals are back-propagated, correlation technique is then used to find errors in arrival time. It is extremely computationally extensive, almost impossible to implement in real-time using current technologies.

Speckle Correlation Analysis41 Wavefront Distortion Measurements on abdominal walls, breasts and chest walls have shown two- dimensional distortion. The distortion includes time delay errors and amplitude errors (resulting from wavefront distortion).

Speckle Correlation Analysis42 Phase Conjugation phase screen at face of transducer displaced phase screen ff phase

Speckle Correlation Analysis43 Phase Conjugation Simple time delays result in linear phase shift in the frequency domain. Displaced phase screens result in wavefront distortion, which can be characterized by non-linear phase shift in the frequency domain.

Speckle Correlation Analysis44 Phase Conjugation Non-linear phase shift can be corrected by dividing the spectrum into sub-bands and correct for “time delays” individually. In the limit when each sub-band is infinitesimally small, it is essentially a phase conjugation technique.