Comparison of Flow Cell vs. Static Cell Kathryn Rose Verfaillie Advisor: Dr. Jeffrey Halpern Acknowledgements This research was supported with funding.

Slides:



Advertisements
Similar presentations
Thin Film Cyclic Voltammetry
Advertisements

Calibration Techniques
Experimental Investigation of Aluminum Nitride and Vanadium Nitride Solubility in Medium-Carbon Steels William Christman, Lee M. Rothleutner, Dr. Chester.
Capability of Immobilisation techniques and detection of Ab-Ag interactions by Eyad Hamad November 2010.
Cyclic Voltametry for the Detection of Dopamine in vivo
BIOREACTOR FLUID PERFUSION SYSTEM Mechanical Engineering Capstone
Determination of pH, Ca2+ and Mg2+ in Saliva
Sample clean-up (MALDI)
SciTOX TM - a low cost toxicity analyser for environmental applications N Glithero 1, J Hay 1, N Pasco 1, D Patterson 2, R Wattinger 2 and R Weld 1 1 Lincoln.
CHEMISTRY ANALYTICAL CHEMISTRY Fall
Hydrogen Peroxide Detection Using Biogenic and Synthetic MnO 2 Shu Feng, Jim Nurmi, Paul Tratynek Satya Chinni, Brad Tebo Department of Environmental and.
Potentiostat Basics I’m Max Yaffe
VOLTAMMETRY A.) Comparison of Voltammetry to Other Electrochemical Methods 1.) Voltammetry: electrochemical method in which information about an analyte.
Fabrication of a Microelectrode Array Biosensor Based on a Modified Enzyme-Chitosan Biocomposite Lorenzo D’Amico October 1, 2008.
Patil et al., Phys. Chem. Chem. Phys. 2000, 2, Methylene blue undergoes a concentration and ionic strength-dependent dimerization: λ max (monomer)
EPPING, LQB381 Flow Diagrams Dr Ron Epping LQB381 Unit Coordinator
Dilution Practice Remember! M 1 V 1 = M 2 V 2 M 1 = concentration of stock solution V 1 = volume of stock solution M 2 = goal concentration V 2 = goal.
CHE 315 – Lecture 10 9/21/05 Equilibrium Review. Equilibrium constant K is dimensionless K>1, reaction is favored K>100, reaction is considered to go.
Cyclic Voltammetry for the Detection of Dopamine in vivo
IC Controls Quality Water Solutions for pH pH / ORP Conductivity Dissolved Oxygen Chlorine Standards R1.0 © 2004 IC CONTROLS Concerns.
Effects of Mixing on Adipic Acid Crystallization Susan Philyaw, Kathryn Baker, Randal Nelson, Jessica Moffitt, Joy Sroykum and Dr. Terry Ring.
Logical In-Vial Dilution with Ultrafiltration for Anion Analysis IC Application Work AW US Presented by Carlos Bazán 1.
Introducti on Objectiv e Experimenta l section Results and discussion Conclusio ns.
The Redox Behaviour of Diazepam (Valium®) using a Disposable Screen- Printed Sensor and Its Determination in Drinks using a Novel Adsorptive Stripping.
Alkaline Methanol Fuel Cell Tam Duong Dr. Yushan Yan.
Voltammetry: A Look at Theory and Application Bobby Diltz 14 March 2005.
Salt Dilution Uncertainty and Proposed Metadata Requirements CWRA Conference Vancouver Gabe Sentlinger Mar 7, 2013.
Nano-sized Zero Valence Iron Detection Jing Zhenqing Shi Paul G. Tratnyek Division of Environmental Biomolecular Systems Oregon Health & Science University.
Aquious Halide Concentration Determination via Leucigenin Quenching and Indirect CE Christopher Hampton, Dr. Eamonn F. Healy, Chemistry Department, St.
Developing a Method for Measuring Amlodipine Levels in Cat Plasma By:Preston Bull Advisors: Mike Gallagher, Dr. Webster.
Quasi-simultaneous Electrochemical and Electrophysiological Measurements at the Same Sensor: Probing the Chemical Environment and Bioelectrical Activity.
Increase in Positive Active Material Utilization in Lead-Acid Batteries Simon McAllister, Rubha Ponraj, I. Francis Cheng, Dean B. Edwards Department of.
Comparison of Flow Cell vs. Static Cell Kathryn Rose Verfaillie Advisor: Dr. Jeffrey Halpern Acknowledgements This research was supported with funding.
N-Propanol Addition n-Butanol Addition n-Pentanol Additon 4.5 % 9% Synthesis of Copper Microspheres Via a Two-Phase System Daniel Darcy, Lea Nyiranshuti,
Quality Assurance How do you know your results are correct? How confident are you?
Section 13 Analytical Voltammetry.
David Perry The University of Warwick Electrochemistry and Interfaces Group Bias Modulated Scanning Ion Conductance Microscopy (BM-SICM)
EIChroM I N D U S T R I E S, I N C. Introduction of Eichrom TEVA Disc: Tc-99 Analysis Anil H. Thakkar, Lawrence Jassin, Michael Fern Eichrom Industries,
Calorimetry. Calculating Heat Q can be found experimentally by measuring the heat flow accompanying a reaction This is done by measuring temperature This.
The Effect of Ratio of Meldola’s Blue to Carbon Powders and Carbon Paste on Detection of Hydrogen Peroxide for the Carbon Paste Electrode Modified with.
DILUTION CALCULATIONS Molarity of Mixture = total moles of chemical in which we are interested total volume of mixture Dilute Solution – a solution with.
The pH on the Detection of Hydrogen Peroxide for Electrode Modified with Chromium Hexacyanoferrate Chen-Hsun Hu ( 胡真熏 ), Ting-Li Lin ( 林庭立 ), Hau Lin (
Kristen Jevsevar Jason McGill Sean Mercado Rebecca Tarrant.
Development of Microfluidic Glucose Sensors BME 273: Kristen Jevsevar, Jason McGill, Sean Mercado, Rebecca Tarrant Advisors: Jennifer Merritt, Dr. John.
Microfluidic Glucose Sensor Senior Design Group 4 Kristen Jevsevar Jason McGill Sean Mercado Rebecca Tarrant.
L = ________ ml what piece of equipment? M = ______mM 3.68 uL = _______ mL what piece of equipment? mg = _______ g what piece of equipment?
T.A Nouf Alshareef KAU-Faculty of Science- Biochemistry department Analytical biochemistry lab (Bioc 343) 2012 False colour scanning.
TECHNETIUM (99mTc) MACROSALB INJECTION Definition Technetium (99mTc) macrosalb injection is a sterile, a pyrogenic suspension of human albumin in the form.
Enzymatic analyses on wine By Wernich Kühn Central Analytical Facility Stellenbosch University.
ELECTROCHEMICAL DETERMINATION OF URANIUM IN SALINE SOLUTIONS Matthew Kirby, 1 Pascal Salaun, 2 Jonathan Watson, 1 and Dominik Weiss. 1 1 Department of.
One-Stage Quantitative
Scanning Electron Microscopy
Rabeay Hassan and Ursula Bilitewski
Two-Electrode Results Three-Electrode Results
RBC Manual Count.
DILUTING A STOCK SOLN To make a soln less concentrated: add solvent
Structure of glass capillary sodium ion selective electrode
HAEMOGLOBIN ESTIMATION
Analysis of Iron Experiments 3, 19 & 20.
Charlie Gasperoni, Christian Tooley, and Jeffrey M. Halpern
s Changes: Cite figures under EIS
PBS buffer preparation &
Softening of Water : Softening can be done in two ways
Wayne Vessey, B. Sc. , Ana Perez-Miranda, Ph. D
Chapter Fifteen VOLTAMMETRY AND ELECTROCHEMICAL SENSORS
70% Hummi Micro-Draw Fluid Movement Reduction
2. Electrochemical techniques complementary to cyclic voltammetry.
Cyclic Voltammetry Dr. A. N. Paul Angelo Associate Professor,
Volume 4, Issue 1, Pages (January 2018)
Preparing Solutions by Dilution
Presentation transcript:

Comparison of Flow Cell vs. Static Cell Kathryn Rose Verfaillie Advisor: Dr. Jeffrey Halpern Acknowledgements This research was supported with funding from the National Science Foundation’s grant to NH EPSCoR (ENG ). The RETE Program, Steve Hale UNH, Alexis Mack, Mariah Arral, Garrett Thompson, Elnaz Mohamadi PSU, Dr Susan Swope, Dr Jeremiah Duncan Overview of Project What Was Done: Assembled a flow cell Tested dopamine in the flow cell and the C3 static cell Will the curves from the two cells look the same or different? Determined advantages and disadvantages of each cell Benefits of Flow Cell: Able to go backwards and forwards in the serial dilution Able to do buffer between each serial dilution Always refreshing the sample over the electrode Uses smaller volumes than a static cell (5 mL vs 40 mL) Overview of Project What Was Done: Assembled a flow cell Tested dopamine in the flow cell and the C3 static cell Will the curves from the two cells look the same or different? Determined advantages and disadvantages of each cell Benefits of Flow Cell: Able to go backwards and forwards in the serial dilution Able to do buffer between each serial dilution Always refreshing the sample over the electrode Uses smaller volumes than a static cell (5 mL vs 40 mL) Static Cell Dopamine is added to the cell Increasing concentration from low to high with micro pipette Uses stir bar to mix added samples Background taken before each experiment Static Cell Dopamine is added to the cell Increasing concentration from low to high with micro pipette Uses stir bar to mix added samples Background taken before each experiment Flow Cell Individual samples are made for each concentration Samples are injected freely via the sample loop Sample is constant refreshed in situ Takes background before each new sample Flow Cell Individual samples are made for each concentration Samples are injected freely via the sample loop Sample is constant refreshed in situ Takes background before each new sample Flow Cell vs. Static Cell Pros: Flow cell uses less volume Two serial dilutions with 2.5 mL of sample Produces more data Less waste Cons: Less experience with equipment Still needs to be perfected Lower amplitude The flow cell is better than the static cell: Linear calibration curve Needs more perfecting Flow Cell vs. Static Cell Pros: Flow cell uses less volume Two serial dilutions with 2.5 mL of sample Produces more data Less waste Cons: Less experience with equipment Still needs to be perfected Lower amplitude The flow cell is better than the static cell: Linear calibration curve Needs more perfecting Making Carbon Electrodes 1.Separate a singular 7 μm diameter carbon fiber 2.Use suction to draw the fiber into a capillary 3.Use the puller to make two pointed electrodes 4.Cut the electrode under the microscope to make a flush tip 5.Seal the electrodes with Epon Resin 828 and m-phenylenediamine epoxy 6.Bevel the electrode to create a flush disc electrode Making Carbon Electrodes 1.Separate a singular 7 μm diameter carbon fiber 2.Use suction to draw the fiber into a capillary 3.Use the puller to make two pointed electrodes 4.Cut the electrode under the microscope to make a flush tip 5.Seal the electrodes with Epon Resin 828 and m-phenylenediamine epoxy 6.Bevel the electrode to create a flush disc electrode Voltammetric Analysis Fast Scan Cyclic Volatammetry. Gamry Potentiostat Scan rate of 300 V/s Each electrochemically active species creates a signal Background Subtraction Removes noise and background to get the pure dopamine curve Voltammetric Analysis Fast Scan Cyclic Volatammetry. Gamry Potentiostat Scan rate of 300 V/s Each electrochemically active species creates a signal Background Subtraction Removes noise and background to get the pure dopamine curve ( ENG) Static Cell Experimental Set Up - Photo by Elnaz Mohamadi Carbon Working Phosphate buffered saline solution with sample Ag/AgCl Reference Platinum Counter Sample Addition Making Electrodes - Photos by Mohamadi & Thompson, Carbon fiber Suction Capillary Flow Cell Experimental Set Up Platinum Counter Ag/AgCl Reference Carbon Working Phosphate buffered saline solution Sample Loop Sample Phosphate buffered saline solution