Quantitative X-ray Spectrometry in TEM/STEM

Slides:



Advertisements
Similar presentations
NUCP 2371 Radiation Measurements II
Advertisements

X-Ray Astronomy Lab X-rays Why look for X-rays? –High temperatures –Atomic lines –Non-thermal processes X-ray detectors X-ray telescopes The Lab.
Fire Protection Laboratory Methods Day
Rutherford Backscattering Spectrometry
Module 2: Analytical methods and separation techniques.
Spectrum Identification & Artifacts Peak Identification.
Quantitative EDX Analysis in TEM
Compositional Mapping
Nature and origin of X-rays Interaction of X-rays with atoms
Types of Radiation Interactions All or Nothing Many Small There is a finite probability per unit length that the radiation is absorbed. If not, there is.
RHESSI/GOES Observations of the Non-flaring Sun from 2002 to J. McTiernan SSL/UCB.
ED and WD X-ray Analysis
X-Ray Microanalysis – Precision and Sensitivity Recall… K-ratio Si = [I SiKα (unknown ) / I SiKα (std.) ] x CF CF relates concentration in std to pure.
1 PASI - Electron Microscopy - Chile Lyman - Nanoparticles AEM Analysis of Nanoparticles Charles Lyman Lehigh University Bethlehem, PA.
Rutherford Backscattering Spectrometry
Qualitative, quantitative analysis and “standardless” analysis NON DESTRUCTIVE CHEMICAL ANALYSIS Notes by: Dr Ivan Gržetić, professor University of Belgrade.
Thin Film Quantitation of Chemistry and Thickness Using EPMA John Donovan Micro Analytical Facility CAMCOR (Characterization of Advanced Materials in Oregon)
Cross section measurements for analysis of D and T in thicker films Liqun Shi Institute of Modern Physics, Fudan University, Shanghai, , People’s.
Classification of Instruments :
Types of Analyses Single Collector –Uses only one collector or detector –This is the case with a Daly or EM Advantages: –Need only one detector –Peaks.
Chapter 1 Equations, Inequalities, and Mathematical Models 1.4 Complex Numbers.
RF background, analysis of MTA data & implications for MICE Rikard Sandström, Geneva University MICE Collaboration Meeting – Analysis session, October.
Proteomics Informatics – Data Analysis and Visualization (Week 13)
Lecture 1. References In no particular order Modern Digital and Analog Communication Systems, B. P. Lathi, 3 rd edition, 1998 Communication Systems Engineering,
Diffraction Lineshapes (From “Transmission Electron Microscopy and Diffractometry of Materials”, B. Fultz and J. Howe, Springer-Verlag Berlin Chapter.
PASI - Electron Microscopy - Chile 1 Lyman - EDS Qual Energy-Dispersive X-ray Spectrometry in the AEM Charles Lyman Based on presentations developed for.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze: Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS Detection.
ITAM CAS, IEAP CTU IWORID 2004Glasgow, th July IWORID 2004 OPTIMIZATION OF X ‑ RAY DYNAMIC DEFECTOSCOPY USING MEDIPIX-2 FOR HIGH FRAME RATE READ-OUT.
Lecture 11b Atomic Physics & Nuclear Reactions Copyright © 2009 Pearson Education, Inc.
EDS Energy Dispersive Spectroscopy
Quantitative Analysis Quantitative analysis using the electron microprobe involves measuring the intensities of X-ray lines generated from your unknown.
Electron Energy-Loss Spectrometry (EELS)

Essentials of College Physics --Serway/Vuille
What is an error? An error is a mistake of some kind... …causing an error in your results… …so the result is not accurate.
PHYS 430/603 material Laszlo Takacs UMBC Department of Physics
Energy-Dispersive X-ray Microanalysis in the TEM Anthony J. Garratt-Reed Neil Rowlands.
Other modes associated with SEM: EBIC
XBSM Analysis - Dan Peterson Review of the optics elements: Pinhole (“GAP”), FZP, Coded Aperture Extracting information from the GAP what is the GAP width?
SNS neutron background measurements using a portable 3 He LPSD detector.
A New Analytic Model for the Production of X-ray Time Lags in Radio Loud AGN and X-Ray Binaries John J. Kroon Peter A. Becker George Mason University MARLAM.
References Hans Kuzmany : Solid State Spectroscopy (Springer) Chap 5 S.M. Sze Physics of semiconductor devices (Wiley) Chap 13 PHOTODETECTORS.
MS Calibration for Protein Profiles We need calibration for –Accurate mass value Mass error: (Measured Mass – Theoretical Mass) X 10 6 ppm Theoretical.
2. RUTHERFORD BACKSCATTERING SPECTROMETRY Basic Principles.
PrimEx collaboration meeting Energy calibration of the Hall B bremsstrahlung tagging system using magnetic pair spectrometer S. Stepanyan (JLAB)
Sources of noise in instrumental analysis
Advanced Analytical Chemistry – CHM 6157® Y. CAIFlorida International University Updated on 9/26/2006Chapter 3ICPMS Interference equations Isobaric.
Digital primary electron counting: W, Fano Factor, Polya vs Exponential M. Chefdeville, NIKHEF, Amsterdam RD51, Paris, October 2008.
SEM- Schematic Overview. Electron Detection Tungsten Filament Electron Source.
X-Ray Microanalysis – Precision and Sensitivity Recall… wt.fraction I = I SiKα (unknown) / I SiKα (pure std.) K-ratio I = [I SiKα (unknown ) / I SiKα (std.)
Electron probe microanalysis Low Voltage SEM Operation Modified 9/23/10.
Chapter 1 Introduction. Theories and Experiments The goal of physics is to develop theories based on experiments A theory is a “guess,” expressed mathematically,
X-ray microanalysis in the electron microscope
Determining Radiation Intensity
Basics of Ion Beam Analysis
Lecture 8 Optical depth.
1 Electra Foil Heating Analysis D. V. Rose, a F. Hegeler, b A. E. Robson, c and J. D. Sethian c High Average Power Laser Meeting PPPL, Princeton, NJ October.
Peterson xBSM Optics, Beam Size Calibration1 xBSM Beam Size Calibration Dan Peterson CesrTA general meeting introduction to the optics.
XBSM Analysis - Dan Peterson Review of the optics elements: Pinhole (“GAP”), FZP, Coded Aperture Extracting information from the GAP what is the GAP width?
Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on work from: France:POMME B. Bonin et al. Nucl. Inst.
Chapter 9 Stellar Atmospheres. Specific Intensity, I I ( or I ) is a vector (units: W m -2 Hz -1 sterad -1 )
RTT 425 Radiation Therapy Physics Radiation Quality, Chapter 4 From Stanton and Stinson: Applied physics for Radiation Oncology.
Spatial Resolution and minimum detection
Low-Loss and No-Loss Spectra
Electron probe microanalysis EPMA
Instrument Parameters in WDXRF
Electron probe microanalysis EPMA
Chem. 133 – 2/16 Lecture.
Electron probe microanalysis EPMA
College Physics Chapter 1 Introduction.
Presentation transcript:

Quantitative X-ray Spectrometry in TEM/STEM Charles Lyman Lehigh University Bethlehem, PA Based on presentations developed for Lehigh University semester courses and for the Lehigh Microscopy School

Quantitative X-ray Analysis of Thin Specimens How much of each element is present? Aim of quantitative analysis: to transform the intensities in the X-ray spectrum into compositional values, with known precision and accuracy Cliff-Lorimer method: Precision: collect at least 10,000 counts in the smallest peak to obtain a counting error of less than 3% Accuracy: measure kAB on a known standard and find a way to handle x-ray absorption effects CA = concentration of element A IA = x-ray intensity from element A kAB = Cliff-Lorimer sensitivity factor What could be simpler?

Assumptions in Cliff-Lorimer Method Basic assumptions X-ray intensities for each element are measured simultaneously Ratio of intensities accounts for thickness variations Specimen is thin enough that absorption and fluorescence can be ignored the “thin-film criterion” We would like to handle absorption in a better way! Cliff-Lorimer equation: CA and CB are weight fractions or atomic fractions (choose one, be consistent) kAB depends on the particular TEM/EDS system and kV (use highest kV) k-factor is most closely related to the atomic number correction Can expand to measure ternaries, etc. by measuring more k-factors

Steps in Quantitative Analysis Remove background intensity under peaks Integrate counts in peaks Determine k-factors (or z-factors) Correct for absorption (if necessary)

Calculate Background, the Subtract Gross-Net Method Draw line at ends of window covering full width of peak Impossible with peak overlap Should work better above 2 keV where background changes slowly Three-Window Method Set window with FWHM (or even better 1.2 FWHM) Average backgrounds B1 and B2 Subtract Bave from peak Requires well-separated peaks Background Modeling Mathematical model of background as function of Z and E Useful when peaks are close together from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Digital Filtering Convolute spectrum with “top-hat” filter Multiply channels of top-hat filter times each spectrum channel Place result in central channel Step filter over each spectrum channel Background becomes zero from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Digital Filtering Spectrum before filtering Spectrum after filtering Note MgK, AlK, and SiK Spectrum after filtering Positive lobes are proportional to peak intensities from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Obtaining k-factors Requirements for standard specimen for k-factor measurement Single phase (stoichiometric composition helpful) Homogeneous at the nanometer scale Thinned to electron transparency without composition change (microtome) Insensitive to beam damage Measure k-factors on a known standard: Usually kASi or kAFe Measure k-factors at various thicknesses and extrapolate to zero thickness Other ways Calculate k-factors (when standards are not available) Use literature values at same kV for x-rays 5-15keV (not recommended) Use kAB = kAC/kBC (use only when necessary - errors add)

Why Collect 10,000 Counts? There is a 99% chance that a single measurement is within 3N1/2 of the true value The relative counting error = Thus, for 10,000 counts the relative counting error =

Experimental k-factors from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Calculated k-factors When suitable standard is not available When a modestly accurate analysis is acceptable Most EDS system software can calculate k-factors But errors can be up to 20% Simple expression: but Q not known well which leads to error Q = ionization cross-section = fluorescence yield a = relative transition probability = A = atomic weight e = detector efficiency

Calculated k-factors Calculated kAFe-factors using different ionization cross-sections from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

kAFe for K-series Errors of calculated versus standards ~ 4% from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

kAFe for L-series Errors of calcuated versus standards up to 20% from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

The Absorption Problem k-factors measured at different specimen thicknesses will be different X-rays from some elements will be absorbed more than others “Thin-film criterion” breaks down if high accuracy required We need a better way to handle absorption effects What to do: Measure unknown and standard at the same thickness (impractical) Extrapolate all k-factors to zero-thickness, then apply absorption correction to each measurement (but we need to know the specimen thickness) Use z-factors from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Extrapolate to the Zero-Thickness k-factor Horita et al. (1987) and van Cappellan (1990) methods Zero-thickness k-factor from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Obtaining the Zero-thickness k-factor Thin standard of known composition Pt-13wt% Rh thermocouple wire Thickness measured by EELS log-ratio method

Absorption Correction Effective sensitivity factor kAB* = kAB(ACF) Zero-thickness k-factor Equation 35.29: from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Original -factor method Absorption correction contains t foil thickness t must be determined at analysis point specimen density  for composition at analysis point) -factor method assume x-ray intensity  t then subsititute into absorption equation: We can determine both absorption-corrected compositions and t if kAB and zA known from measurements on standard

Modified -factor method Measure the z-factor for both elements: Assume CA + CB = 1 for binary system and rearrange: Determine CA, CB, and rt simultaneously from three equations in three unknowns t can be determined if density is known M. Watanabe and D.B. Williams, Z. Metalkd. 94 (2003) 307-316

z-factor z factor is dependent on x-ray energy accelerating voltage beam current z factor is independent of specimen thickness specimen composition specimen density

Quantitative analysis by z factor method Lucadamo et al. (1999)

Effect of kV on Beam Spreading Elastic scattering broadens the beam as it traverses the specimen Beam broadening is less for Higher kV Lighter materials Smaller thicknesses Goldstein-Reed Eqn. b b from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Spatial Resolution vs. Analytical Sensitivity Conditions that favor high spatial resolution (thinnest specimen) result in poorer analytical sensitivity and vice versa. For example to obtain equivalent analytical sensitivity in an AEM to an EPMA, the X-ray generation and detection efficiency would have to be improved by a factor of 108 from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Composition Profiles Across an Interphase Interface The change in Mo and Cr composition across the interface can be used to determine the compositions of the phases either side of the interface which, in turn, give the tie lines on the Ni-Cr-Mo phase diagram. Courtesy R. Ayer from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Measurement of Low T Diffusion Data Low-temp data High-temp data Measurement of composition profiles with high spatial resolution permits extraction of low- temperature diffusion data because the small diffusion distances at low T are detectable by AEM X-ray microanalysis. Here Zn profiles across a 200 nm wide precipitate-free zone in Al-Zn are used to determine values of the Zn diffusivity at T = 100-200°C. Courtesy A.W. Nicholls from Williams and Carter, Transmission Electron Microscopy, Springer, 1996

Predicted Phase Separation Observed in Nanoparticles Two phases observed Pt-rich phase Rh-rich phase Dotted misibility gap was predicted from other similar systems --> only observed in nanoparticles C. E. Lyman, R. E. Lakis, and H. G. Stenger, Ultramicroscopy 58 (1995) 25-34.

Summary Know the question you are trying to answer Know the precision and accuracy required to answer the question Accumulate enough counts in the spectrum to achieve the required precision (> 10,000 counts in the smallest peak) Know the precision and accuracy of your k-factor Measure zero-thickness k-factors and apply an absorption correction (need t at analysis point) or use z-factors where t is not needed Spatial resolution vs. detectability: You cannot achieve the highest spatial resolution and the best analytical sensitivity under the same experimental conditions