7154 VFD Presentation #5 June 2002 Paul Weingartner.

Slides:



Advertisements
Similar presentations
Getting a Device on the Network. Node Commissioning of Devices Every DeviceNet device needs at a minimum a unique node address (0-63) and appropriate.
Advertisements

DeviceNet 2400, 2500, 26/2700.
INPUT-OUTPUT ORGANIZATION
ABB standard drive Enhanced ACS550
MLC Connectivity to SLC 500 via DeviceNet
Stack Light 855T Julian E. Palacios 5/8/2007. Typical DeviceNet Configuration A DeviceNet Network supports multiple Stack Light devices and allows them.
AC-SSC-1 Installation and operation manual
Protocol Configuration in Horner OCS
SmartVFD HVAC and BYPASS Introduction. 2 Smart Technology to Reduce Electricity Consumption “Today, our continuing progress is restricted…not by the power.
Variable Frequency Drives VFD Basics
IT Essentials: PC Hardware and Software 1 Chapter 3 Assembling a Computer.
Presents The Silver Family An Integrated Approach to Processors, Data Communication and Head End Integration.
Chapter 22 All About SCSI.
Introduction. 2 What Is SmartFlow? SmartFlow is the first application to test QoS and analyze the performance and behavior of the new breed of policy-based.
January 2015 SlimLine XR ITS 2.
AS-i, The Simplest Automation Networking Solution Dated: 10/30/2008.
Industrial Networks 3/22. Industrial Controls Netwoks.
Copyright © 2002 Delmar Thomson Learning Chapter 9 Putting Together a Modular PLC.
Chapter 8 Output Modules.
MUST HAVE SHOULD HAVE COULD HAVE Module # 010. Qi Hardware Objectives Recognize hardware Know how to interface to field equipment Know the 4 different.
EZ Positioning with SINAMICS S120 Agenda
Make the most of your energy Make the most of your energy SM Add photo in this area Chicago Advanced Energy Stakeholder Series 2014 Mike Mattingly Oct.
NETWORKING HARDWARE.
INPUT-OUTPUT ORGANIZATION
1 Xcel Energy Webinar October 24, :30 am to 1:00 pm CT VFDs Drive Efficiency: Learn how Variable Frequency Drives can benefit your facility.
Internet Schneider Electric Todd A. Snide, 12 October 2006 Automation Business Unit.
1. 2 How do I verify that my plant network is OK? Manually: Watch link lights and traffic indicators… Electronically: Purchase a SNMP management software.
1 MUST HAVE SHOULD HAVE COULD HAVE Module # Configuring the Qi Cluster Objectives: Know the sequence of configuring the Qi Cluster Know how to.
Firewall Typical Networking and Troubleshooting Common Faults.
Hands-on Networking Fundamentals
Looking for a more powerful circuit monitor?
POWER SAVING BY ROCKSOLID INDUSTRIAL SOLUTIONS SYSTEMS REQUIRING PUMPS USING VALVE CONTROL SYSTEMS REQUIRING FANS USING DAMPER CONTROL SAVE GOOD $MONEY$
7154 VFD Presentation #4 May 2002 Paul Weingartner.
Identifying SLC 500™ System Components. SLC 500 System Options  The SLC 500 line of processors comprises both fixed and modular processor styles.:
PowerFlex 755 DeviceLogix
Managing Windows Server 2008 R2 Lesson 2. Objectives.
Application Protocol for Veris E30 Panel-board Monitoring System Jaein Jeong UC Berkeley LoCal Workshop Oct 5 th, 2009.
DeviceNet Solution December, 2003
I/O Example: Disk Drives To access data: — seek: position head over the proper track (8 to 20 ms. avg.) — rotational latency: wait for desired sector (.5.
INTER REGIONAL PROCESSOR. DESIGN PHILOSOPHY n Based on industry standard pc hardware. n Industrial specification IBM compatible computer running Fylde.
10/5/ InstantHMI Designed for Watlow Beam the Palm at your Watlow SD controller and voila!, you have a low cost HMI for Configuration, Diagnosis,
COMPACT Variable Frequency Drives. Honeywell Proprietary Honeywell.com  Buildings Consume Massive Amounts of Energy Commercial Buildings consume massive.
Turbine Crane CRANES TURBINE NEA39. Turbine Crane PLANT STATUS! PV Daily Status Report.
M340 Modbus Plus Proxy Link legacy systems to Ethernet
Chapter 10 Advanced Programming, PLC Interfacing, and Troubleshooting
3-Phase Submersible Motor Control
11 INSTALLING AND MANAGING HARDWARE Chapter 6. Chapter 6: Installing and Managing Hardware2 INSTALLING AND MANAGING HARDWARE  Install hardware in a Microsoft.
CUE – Make Any Pump an E-Pump
Variable Speed Applied to Pumps. Life Cycle Costs - Courtesy of Hydraulic Institute and Europump Initial cost is not the only cost associated with a pump.
Linux Operations and Administration
Putting Together a Modular PLC
1 Chapter Overview Modems The Internet and Web Browsers.
© N. Ganesan, Ph.D., All rights reserved. Chapter Formatting of Data for Transmission.
بسم الله الرحمن الرحيم MEMORY AND I/O.
4000 Imaje 4020 – Software Imaje 4020 – Content ■ Content of Chapter Software: 1. Flash Up 2. Netcenter 3. FTP 4. Active X 5. XCL commands 6. Exercise.
7/15/2002PP.AFD.09 1 of 43 Yaskawa Electric America Variable Frequency Drives In HVAC Applications.
LonWorks Introduction Hwayoung Chae.
Run the on your PC to start the firmware configuration process Run IP Config Tool.
A+ Guide to Managing and Maintaining Your PC Fifth Edition Chapter 17 Supporting Modems.
Cisco I Introduction to Networks Semester 1 Chapter 6 JEOPADY.
An Overview When Connecting to Yaskawa Drives Date: 8/14/06, Rev: PP.AFD.26.
Software Troubleshooting Eliminate possible programming and timing errors by stopping all programs ( and ). Use the Executive program terminal and send.
CMV-NET Chigo VRF Network Centralized Control System
Variable Frequency Drive Savings Calculator Tools
SPOC Automation and BECI- who are we?
Identifying SLC 500™ System Components
Hubs Hubs are essentially physical-layer repeaters:
Welcome! Thank you for joining us. We’ll get started in a few minutes.
Vibration Monitoring System M14
Training Module Introduction to the TB9100/P25 CG/P25 TAG Customer Service Software (CSS) Describes Release 3.95 for Trunked TB9100 and P25 TAG Release.
Presentation transcript:

7154 VFD Presentation #5 June 2002 Paul Weingartner

Application of VFDs

VFDs applied for energy savings mation/features/BNP__Features__Item/0, 1338,73944,00.html mation/features/BNP__Features__Item/0, 1338,73944,00.html In the hvac industry, vfd’s are usually found on motors that drive fans, blowers, pumps, cooling towers, etc. The Department of Energy reports that 64% of all electrical energy in the U.S. is consumed by electric motors.

Typical energy savings According to some studies, the addition of vfd’s to an existing system can result in a reduction in energy consumption of 30% to 60%. ASHRAE Standard 90.1 will effectively require vfd’s on every hvac motor except the smallest ones in commercial buildings of more than 25,000 sq ft.

Water pumping example With a 25hp motor running 23 hours per day (2 hours at 100 percent speed; 8 hours at 75 percent; 8 hours at 67 percent; 5 hours at 50 percent, which is typical of the water supply industry) a VFD can reduce energy use by 45 percent.At 10 cents/ kWh, this results in an annual savings of $5,374. Source: CEC, sys/Water_Pump_Bro.pdf

Comparison of valve vs. VFD pump

Observation If the rate of electricity is $0.02 per KWHr, the chances are slim that you’ll be able to cost justify a Variable Frequency Drive for your system. However, if the electricity rate is $0.05 per KWHr or higher, you can expect to show fast paybacks for virtually any system.

How is the current system being used The Duty Cycle of your system (where the system operates and for how long) will also affect potential savings. If, for instance, the system tends to operate close to the Design Point for the majority of the time, the savings potential through speed control is limited. On the other hand, if the system is operating at reduced flows for extended periods of time, the potential savings by using VFD’s is great. The Duty Cycle of your system (where the system operates and for how long) will also affect potential savings. If, for instance, the system tends to operate close to the Design Point for the majority of the time, the savings potential through speed control is limited. On the other hand, if the system is operating at reduced flows for extended periods of time, the potential savings by using VFD’s is great

Cost savings table

Centrifugal pump

Money A penny saved in NOT equal to a penny earned!! For commercial businesses, a penny saved is equal to 20 pennies earned (revenue) because the net income approximates to 5% of the revenue. m m m m

Payback Not this kind of Payback

Payback

Using energy eff motor S = x HP x C x N [ 100/SE - 100/PE ] S = Energy Savings per 100% load C = Energy Costs $ per kilowatt hour (KWH) N = Hours per year running time SE = Standard efficiency product at full load PE = Premium efficiency product at full load

Device Net Standards based protocol Must supply external 24VDC to network Typical devices VFD VFD PLC PLC Displays Displays Push buttons Push buttons Photoeyes Photoeyes Motor starters Motor starters

Devices Each device on the network is a “node” Max of 64 nodes (0-63) Each device must be “commisioned” before use. The default address is 63 and should be changed in configuration The default address is 63 and should be changed in configuration Each node must be unique Can’t have two nodes both with the same address Can’t have two nodes both with the same address

RS Networx With RSNetWorx Software for DeviceNet Network you can: Define the devices that are present on your network. You can either manually drag/drop devices/modules or go online to a DeviceNet network and let the software determine the devices/modules that are present. Define configuration settings for devices on the DeviceNet network through a convenient property page interface. Define the input/output information exchanges that you want to take place on the DeviceNet network.

DeviceNet features Low Cost (Based on low cost CAN chip). High Speed. It supports 3 baud rates: 125Kbps, 250Kbps and 500 Kbps which is believed to meet 95% of the industrial requirement. Reliable. It uses the well proven CAN protocol incinerates with the application layers that has undergone strict conformance testing to ensure the reliability. Support up to 64 active nodes. In theory, the node can be expended by using bridge system (such as CAN/CAN bridge or other gateway). Easy installation. Virtually "Plug-and-Play"

Cable lengths

PLC DeviceNet Accomplished with a DeviceNet Scanner card 1747-SDN (for SLC500 family) Plugs into standard slot Takes 32 words of memory 1 word = 16 bits = 2 bytes 1 word = 16 bits = 2 bytes

PLC SDN module display Shows both error codes and current operating info Code 92 = no power Code 80 = idle mode Will show its node address

Communication Using a tool such as RS Networx, each device must be given: Node address Node address Told whether it is a master or a slave device Told whether it is a master or a slave device Told what info to share and who to share it with Told what info to share and who to share it with

DeviceNet settings Node address Baud rate (125, 250, 500kb/sec) Master/slave Channel data Destination node address Masking (* careful on Powerflex drives)

Troubleshooting Always, without exception cycle power on all devices after configuration changes in networked systems

Troubleshooting 2 Look for the error codes Always backup and grab baseline data before making changes Check LED status indicators

PLC SDN example PLC addressing O: is the file O: is the file O:2 is the slot O:2 is the slot O:2.1 is the word O:2.1 is the word O:2.1/5 is the bit O:2.1/5 is the bit Numbering starts at zero

Example If the SDN module is in slot 2 of the PLC O:2.0/0 is the run bit for the DeviceNet module O:2.0/0 is the run bit for the DeviceNet module O:2.1 is the Command word O:2.1 is the Command word I:2.1 is the Status word I:2.1 is the Status word

Command word (bit – function) 0= Stop 1= Start 4= Direction

Status word (bit – function) 0 = Ready 2 = Command direction 3 = Actual direction 4= Accelerating (1=yes) 5 = Deaccelerating (1=yes) 6 = Alarm 7 = Fault

Powerflex DeviceNet By default 2 words are passed back Status word Status word Speed setting Speed setting Can be configured to send back any parameter of interest Parameters are referenced starting above #379 (the last Powerflex parameter)

Simple program

Tools needed for DeviceNet systems RS Networx for DeviceNET Careful – they sell another version for Control Logix Careful – they sell another version for Control Logix Protocol converter or protocol gateway PC RS Linx (Lite will work)

RS Linx Communication gateway for RS software and the PLC, VFD, Displays You have to see the devices on the net with RS Linx first. Else….

RS Linx versions Lite – ships with PLC software OEM, Gateway – can be used to connect to Active-X compliant systems

What can you do with this stuff WebExcel

RS Drive Tools Ability to backup configuration of drives Clone drive setups Advanced tools – analysis Not for average user Not for average user