SURGICAL PROCEDURE GUIDE FOR IR SYSTEM USING THE UNIVERSAL KIT.

Slides:



Advertisements
Similar presentations
Resorbable transcondylar
Advertisements

SURGICAL PROCEDURE GUIDE FOR BR SYSTEM USING THE UNIVERSAL KIT.
Implants & Instruments for Large External Fixation
Composed by Dr. Gary F. Turnier Implant placement Dr.Gary F. Turnier.
Large Taper Files. Engine-driven files Hand-Using Large Taper Files.
Module 1 TAPPING.
Purpose Body Making module is designed for bending the laminated foil film in the shape of a tube, for welding the side seam and for cutting bodies with.
1. Install Your BalJak™ into floor using driver and drill.
Installation. Indoor Unit Installation Typical Installation.
Machining Two introductory projects 1.Support post for mirror mount 2.Vertical micro-rail mount.
Replacing a Congenitally Missing Lateral Incisor using the Skinny 2.4 The case is a 23 year old petite female.
Fabrication of Fishtank Platform EAS 199B living with the lab.
Gear Drive Flo-tap Installation Instructions Quick Installation Guides: rev. EA – 485 Flanged Flo-tap rev. DB – 485 Threaded.
MORSE TAPER DRILLS Morse taper drills are used when a hole larger than ½” is needed Morse taper drills are used when a hole larger than ½” is needed Morse.
Features Specs Price List Torque Wrench CCCP Space Systems CCCP Model 757XS.
About Servo - dental. about Servo - dental.
Implantology Motor Implanteo ® Unique Selling Points Implantology Motor Implanteo ® Unique Selling Points © 2005 anthogyr ANTHOGYR 164, rue des trois lacs.
IENG 475: Computer-Controlled Manufacturing Systems Lathe Operations
Connecting crank and pivot shaft assemblies. Press fits, or interference fits are sometimes used in manufacturing to reduce manufacturing costs or liabilities.
Lathe Practice & Milling
Lathe and drilling machines
Drill Press Operations
ROTARY CUTTING INSTRUMENTS  Dr.linda Maher. ROTARY CUTTING INSTRUMENTS  A group of instruments operated with a power source and used for cutting, finishing.
PROSTHETIC PROCEDURE MANUAL BR SYSTEM. CEMENTED RESTORATION Impression Copings Set Screw Pick-up Transfer Implant Analog Cemented Abutment Angled Abutment.
Installation. Indoor Unit Installation Typical Installation.
Chapter 23: Drilling and Related Hole-Making Processes
Lathe and drilling machines
Lesson No. 09 Week No. 05 Lesson Name Reamer. REAMER Use:- Reamer is used enlarging by finishing previously drilled hole to accurate size. Material:-
Facility Implants Placement Techniques. Surgical Kit.
Cutting Technology –chip removing –the largest class of manufacturing activities in engineering production –~1.87 million machine tools –~$168 billion.
MegaGen Implant System
NexGen® LCCK 4in1 Workshop Cat. No. Description Screw Inserter Hex Pin Driver/Extractor Femoral Augment Screwdriver.
Description Neck Rounded apical area Rounded apical area - Protects the soft tissue during insertion of the implant Thread.
APOLONIA APOLONIA Submerged Implant System C S M Feb 25, 2009.
Samuel Lee’s Internal Sinus Graft System ver.2. 1.Point Trephine Concept This is the same Concept as the Lance Drill. The ASBE (Adjust able Stopper &
Hand Tools. 1. Adjustable Wrench Adjustable Wrench Turning various size nuts and bolts.
ROTARY CUTTING INSTRUMENTS
Guide to Tatum Hand Tools HT.01 - HT.10. HT.01 Hand Mandrel (for use with HT.09 Implant Driver)
Tatum Tapered Implant Placement Instructions. When acceptable attached Gingiva is present, use an appropriate tissue punch at implant site.
Setting up correctly Different types and their use
Main Parts of a Drilling Machine
1 Manufacturing process-1 ( ) Lathe Operations Guided By:Prepared By: Prof. Stany R. Ghadiyali
SAFE WORK PRACTICES IN AGRICULTURAL MECHANICS AG MECH II.
ENM208 INTRODUCTION to MACHINING ANADOLU UNİVERSITY Industrial Engineering Department.
Module 12 RESTORE RESTORE ® External Hex Implant System Surgical Hands-On.
Rear Cover Assembly The Toodle comes with the rear cover assembled. Normally, there is no need to open the rear cover. In case the rear bearing is stuck.
THE CENTRE LATHE - 'FACING OFF' A very basic operation is called ‘facing off’. A piece of steel has been placed in the chuck and the lathe cutting tool.
Trabecular Metal™ Reverse Shoulder Instruments Cat. No.Description Base Plate Drill, 7.5mm Cortex Drill, 7.5mm Compression.
Benchwork IV –Hand Taps and Hand Reamers
Annex 4 - Moving Frame and Whiffletree assembly
Full Arch Restoration.
Guide Right™ Surgical Guide System
Rear Cover Assembly.
Study Club Name NobelReplace Straight Drill Protocol
Overview on complete guided surgical protocol for partially edentulous cases with NobelSpeedy® Groovy and Shorty.
Overview on complete guided surgical protocol for partially edentulous cases with NobelReplace® Tapered and Replace Select™ Tapered.
Overview on complete guided surgical protocol for partially edentulous cases with NobelReplace® Straight, Replace Select™ Straight and NobelSpeedy® Replace.
Overview on complete guided surgical protocol for edentulous cases with Brånemark System® Groovy and Shorty.
Surgical protocol for NobelParallel™ CC
NobelParallel™ CC.
IENG 475: Computer-Controlled Manufacturing Systems Lathe Operations
Manufacturing Rounded Shapes II
CHAPTER FIVE: Drilling Operation
Horizontal Installation Overview
ZPS Foot and Ankle Display
Ag Mechanics Tools.
Mosaicplasty Using Grafts From the Upper Tibiofibular Joint
Drill America Tool School
MIS ™ Mini Keel Workshop
CNC Turning Cross 11, Tapovan Enclave Nala pani Road, Dehradun : ,
Presentation transcript:

SURGICAL PROCEDURE GUIDE FOR IR SYSTEM USING THE UNIVERSAL KIT

SURGICAL KIT – UNIVERSAL – Guide Drill 2 – Pilot Drills 3 – Twist Drills 4 – Cortical Drills 5 – Drill Extension 6 – Fixture Driver (Manual) 7 – Fixture Driver (Machine) 8 – Torque Wrench 9 – 1.2mm Hex Driver 10 – Parallel Pin 11 – 1.2mm Hex Screw 2

GUIDE DRILL BIOTEM Guide Drill No slipping Precise Positioning Round Drill Risk of slipping may lead to: Less precise positioning Damaging bone tissue Recommended rotational speed1200 rpm Round Drill vs. Point Drill Item Code PD2029

PILOT DRILLS Recommended rotational speed rpm Marker signals depth reached Groove disperses cooling liquid Diameter (Ø) 2.0mm2.9mm Item CodeBTD2015BTD2915

TWIST DRILLS Recommended rotational speed rpm Marker signals depth reached Groove disperses cooling liquid Diameter (Ø) 3.3mm3.6mm4.0mm4.6mm5.6mm Item CodeBTD3315BTD3615BTD4015BTD4615BTD5615

CORTICAL DRILLS Recommended rotational speed rpm Diameter (Ø) 3.4mm3.7mm4.0mm5.0mm6.0mm Item CodeCDA3411SCDA3711SCDA4011SCDA5011SCDA6011S Groove Line sets the limit of drilling

DRILL EXTENSION Robust connective capsule design with easy assembly / disassembly Common connective groove designs create a risk for bending Item Code ETB4526

PARALLEL PIN Item Code DGA1620 Insert this side into Ø 2.0mm osteotomy (after using the straight drill) Insert this side into the implant screw hole

HAND DRIVERS Hex Driver (for torque wrench) Hex Driver (Manual) Hex (Ø)1.2mm Length8mm (Short) 15mm (Long) Item Code HDT1208HDT1215 Hex (Ø)1.2mm Length8mm (Short) 15mm (Long) Item Code HDB1208HDB1215

FIXTURE DRIVERS Neck SizeMiniRegular / Wide MiniRegular / Wide Color Code WhiteBlueWhiteBlue ShortFDIM3108CFDIM2908CFDIH3108FDIH2908 LongFDIM3112CFDIM2912CFDIH3115FDIH2915 Contra-Angle Torque Wrench

Joining the driver with the implant – Simple and Safe 1. Insert driver into the appropriate connective space while applying pressure to the top of the implant holder. 2. Apply pressure at the bottom of the holder in order to release the implant- driver assembly.

DRILLING SEQUENCE IR FIXTURE DRILLING SEQUENCE Guide DrillBTD2015BTD2915BTD3315BTD3615BTD4015BTD4615 -Ø 2.0mmØ 2.9mmØ 3.3mmØ 3.6mmØ 4.0mmØ 4.6mm CDA3413 S Mini Ø 3.5mm CDA4013 S Regular Ø 4.1mm CDA4513SRegular / Wide Ø 4.8mm CDA5013 S Wide Ø 5.5mm *NOTE: Use cortical drill previous to inserting implant in hard bone. ** * *

SURGICAL PROCEDURE MANUAL FOR IR SYSTEM USING THE EXTENDED KIT

SURGICAL KIT - EXTENDED – Guide Drill 2 – Spare Hole 3 – Straight Drills 4 – Tapered Drills 5 – Marking Drills 6 – Cortical Drills 7 – Parallel Pins 8 – Hand Drivers 9 – Torque Wrench 10 – Drill Extension 11 – Spare Holes 12 – Implant Drivers (2 Stage) 13 – Implant Drivers (1 Stage) 12 3 Item Code KIT0700

GUIDE DRILL BIOTEM Guide Drill No slipping Precise Positioning Round Drill Risk of slipping may lead to: Less precise positioning Damaging bone tissue Recommended rotational speed1200 rpm Round Drill vs. Point Drill Item Code PD2029

STRAIGHT DRILLS Recommended rotational speed 1200 rpm Harvest bone at low rotational speed (30-50 rpm) Length8.5mm10mm11.5mm13mm15mm Item CodeBSD2008BSD2010BSD2011BSD2013BSD2015 Ø 2.0mm Irrigation groove for easy penetration of cooling media Stopper for increased drilling precision (prevents over-drilling) Straight drill design

TAPERED DRILLS (1/2) Recommended rotational speed 1200 rpm Harvest bone at low rotational speed (30-50 rpm) Irrigation groove for easy penetration of cooling media Stopper for increased drilling precision (prevents over-drilling) Taper angle of 15°

TAPERED DRILLS (2/2) Length8.5mm10mm11.5mm13mm15mm Item CodeBTD3008BTD3010BTD3011BTD3013BTD3015 Ø 3.0mm Length8.5mm10mm11.5mm13mm15mm Item CodeBTD3308BTD3310BTD3311BTD3313BTD3315 Length8.5mm10mm11.5mm13mm15mm Item CodeBTD3608BTD3610BTD3611BTD3613BTD3615 Length8.5mm10mm11.5mm13mm15mm Item CodeBTD3808BTD3810BTD3811BTD3813BTD3815 Length8.5mm10mm11.5mm13mm15mm Item CodeBTD4208BTD4210BTD4211BTD4213BTD4215 Ø 3.6mm Ø 3.3mm Ø 3.8mm Ø 4.2mm

MARKING DRILLS Recommended rotational speed rpm Harvest bone at low rotational speed (30-50 rpm) Diameter (Ø) 2.7mm4.6mm5.0mm5.6mm Item CodeMDR2713MDR4613MDR5013MDR5613 Irrigation groove for easy penetration of cooling media Stopper for increased drilling precision (prevents over-drilling) Lateral microgrooves enhance cooling media dispersion

CORTICAL DRILLS Recommended rotational speed rpm Diameter (Ø) 3.4mm3.7mm4.0mm4.5mm5.0mm6.0mm Item Code CDA3411CDA3711CDA4011CDA4511CDA5011CDA6011 Marker signals Limit of groove line Groove Line sets the limit of drilling

DRILL EXTENSION Robust connective capsule design with easy assembly / disassembly Common connective groove designs create a risk for bending Item Code ETB4526

PARALLEL PIN Item Code DGA1620 Insert this side into Ø 2.0mm osteotomy (after using the straight drill) Insert this side into the implant screw hole

HAND DRIVERS Hex Driver (for torque wrench) Hex Driver (Manual) Hex (Ø)1.2mm Length8mm (Short) 15mm (Long) Item Code HDT1208HDT1215 Hex (Ø)1.2mm Length8mm (Short) 15mm (Long) Item Code HDB1208HDB1215

FIXTURE DRIVERS Neck SizeMiniRegular / Wide MiniRegular / Wide Color Code WhiteBlueWhiteBlue ShortFDIM3108CFDIM2908CFDIH3108FDIH2908 LongFDIM3112CFDIM2912CFDIH3115FDIH2915 Contra-Angle Torque Wrench

Joining the Driver with the Implant Fixture 1. Apply pressure on the top part of the fixture mount then insert driver into the appropriate connective space 2. Apply pressure on the bottom part of the fixture mount in order to release the implant-driver assembly. Ergonomic mount design allows for a simple assembly with the driver as well as a safe manipulation.

DRILLING SEQUENCE IR FIXTURE DRILLING SEQUENCE (1/2) Point DrillStraight DrillTapered DrillImplantTapered Drill Implant -Ø 2.0mmØ 3.0mmØ 3.5mmØ 3.3mmØ 3.6mmØ 4.1mm

DRILLING SEQUENCE IR FIXTURE DRILLING SEQUENCE (2/2) Tapered DrillImplantMarking Drill Implant Ø 4.2mmØ 4.8mmØ 4.6mmØ 5.0mmØ 5.5mm