Part 1: The root of all evil Part 2: Fluorescence microscopy

Slides:



Advertisements
Similar presentations
Absorption of photon elevates chromophore to excited state.
Advertisements

Fluorescence and Confocal Microscopy
Page 1 Klaus Suhling Department of Physics Kings College London Strand London WC2R 2LS UK Fluorescence Lifetime Imaging (FLIM) of molecular rotors maps.
Multiphoton and Spectral Imaging. Multiphoton microscopy Predicted by Maria Göppert-Mayer in 1931 Implemented by Denk in early 1990s Principle: Instead.
Multi-photon Fluorescence Microscopy. Topics Basic Principles of multi-photon imaging Laser systems Multi-photon instrumentation Fluorescence probes Applications.
Victor Sourjik ZMBH, University of Heidelberg
D e t e c t o r s f o r H P L C.
High Speed, Full-Spectrum Spinning-disk Confocal.
Raman Spectroscopy A) Introduction IR Raman
Big Question: We can see rafts in Model Membranes (GUVs or Supported Lipid Bilayers, LM), but how to study in cells? Do rafts really exist in cells? Are.
מיקרוסקופיה פלואורסנטית. Contrasting techniques - a reminder… Brightfield - absorption Darkfield - scattering Phase Contrast - phase interference Polarization.
Observing the Microbial Cell
Microscopy Outline 1.Resolution and Simple Optical Microscope 2.Contrast enhancement: Dark field, Fluorescence (Chelsea & Peter), Phase Contrast, DIC 3.Newer.
Live cell imaging. Why live cell imaging? Live cell analysis provides direct spatial and temporal information Planning your experiment – The markers/fluorophores.
1. Resolution (R) : separation of close objects, light wavelength NA, numerical aperture 2. Contrast : distinction of objects from background “light field”
Multi-Photon Principles - topics- l Confocal complements Multi-Photon. l What is an emission event ? l Single photon event. l Stokes’ shift and what you.
Fluorophores bound to the specimen surface and those in the surrounding medium exist in an equilibrium state. When these molecules are excited and detected.
Fluorescence microscopy – Principle and practical consideration Hiro Ohkura.
CALCIUM IMAGING Beata M. Wolska, Ph.D.
Methods: Fluorescence Biochemistry 4000 Dr. Ute Kothe.
Short pulses in optical microscopy Ivan Scheblykin, Chemical Physics, LU Outline: Introduction to traditional optical microscopy based on single photon.
Non-radiative energy transfer from excited species to other molecules
Confocal & Two-photon Microscopy. Contents 1.Two-Photon Microscopy : Basic principles and Architectures 2. Resolution and Contrast in Confocal and Two-Photon.
Microscopy is about a combination of resolution (seeing smaller and smaller things), and contrast (seeing what you want to see). Both aspects have recently.
Light and Fluorescence
Methods: Single-Molecule Techniques Biochemistry 4000 Dr. Ute Kothe.
Microscopy is about a combination of resolution (seeing smaller and smaller things), and contrast (seeing what you want to see). Both aspects have recently.
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
Fluorescence Microscopy Chelsea Aitken Peter Aspinall.
Methods, Part 2 February 9, Learning Outcomes Discriminate between different types of microscopy, and justify their use for answering research questions.
Common types of spectroscopy
Practical aspects of fluorescence microscopy
Microscopy.
Illumination and Filters Foundations of Microscopy Series Amanda Combs Advanced Instrumentation and Physics.
DIC, fluorescence and confocal microscopy Department of Mechatronics GIST Yong-Gu Lee References: 1.“Fundamentals of light microscopy and electronic imaging,”
Are You FRETting? Find Out for Sure With FLIM Frequency Domain FLIM for Your Scope Intelligent Imaging Innovations.
FRET(Fluorescent Resonance Energy Transfer)
TIRF Total Internal Reflection Fluorescence Microscopy specialized fluorescence microscopy technique specifically images a very thin optical section (50-250nm)
Simple to Complex – Life’s Levels of Organization
Fluorescence Techniques
The current state of Confocal Scanning Laser Microscopy Hjalmar Brismar Cell Physics, KTH.
Agenda How to make the specimen visible – Definition of Contrast
By: Rob Page and Tara Trovarello
Fluorescence Absorption of light occurs within ~ seconds, leaving a molecule in an excited state What happens next? –If no photon is re-emitted,
BIO 224 Intro to Molecular and Cell Biology. Microscopes are tools frequently used in cell biology Type of microscope used depends on the specimen being.
Advanced Biology Visualizing Cells. The Human Eye  Resolution – The minimum distance two points can be apart and still be distinguished as two separate.
Powerpoint Templates Page 1 Powerpoint Templates Spectroscopic Microscopy.
Functional cellular imaging by light microscopy MICROSCOPIES.
Developments in Imaging Technology and Staining Techniques Unit C: Section 1.3 Science 10.
Fluorescence microscopy Principle and applications.
Molecular Cell Biology Light Microscopy in Cell Biology Cooper Modified from a 2010 lecture by Richard McIntosh, University of Colorado.
Confocal Laser Scanning Microscopy: general considerations and techniques Simone Bossi.
1.Stable radiation source 2.Wavelength selector 3.Transparent sample holder: cells/curvettes made of suitable material (Table 7- 2) 4.Radiation detector.
Imaging Technology and Staining Techniques CHAPTER 1.3.
Förster Resonance Energy Transfer (Chemistry/Biology Interface) Michelle, Pauline, Brad, Thane, Hill, Ming Lee, Huiwang Facilitator: Nancy.
Designing a Microscopy Experiment Kurt Thorn, PhD Director, Image from Susanne Rafelski, Marshall lab.
Imaging.
Microscopy Group 2 Cabatit, Mendoza, Ramos, Rodriguez, Tan.
By c.Keerthana.  First described by Dutch physicist frits Zernike in  It is a type of light microscopy.  It is a contrast enhancing optical technique.
Physics 598BP Today: Fluorescence What is it? Why is it good?
Practical Absorbance and Fluorescence Spectroscopy
Reliable and Global Measurement of Fluorescence Resonance Energy Transfer Using Fluorescence Microscopes  Zongping Xia, Yuechueng Liu  Biophysical Journal 
Molecular Dynamics in Living Cells Observed by Fluorescence Correlation Spectroscopy with One- and Two-Photon Excitation  Petra Schwille, Ulrich Haupts,
Quantification of Membrane Protein Dynamics and Interactions in Plant Cells by Fluorescence Correlation Spectroscopy  Xiaojuan Li, Jingjing Xing, Zongbo.
LIGHT MICROSCOPY variations
Förster Resonance Energy Transfer (FRET)
FLUORESCENCE MICROSCOPY
Observing Microorganisms Through a Microscope
Imaging techniques for next generation plant cell biology.
Polarized Fluorescence Resonance Energy Transfer Microscopy
Presentation transcript:

Bringing Light into the chaos: a general introduction to optics and light microscopy Part 1: The root of all evil Part 2: Fluorescence microscopy and special applications

Contrasting techniques - a reminder… Brightfield -absorption Darkfield -scattering Phase Contrast -phase interference Polarization Contrast -polarization Differential Interference Contrast (DIC) -polarization + phase interference Fluorescence Contrast

Fluorescence techniques Standard techniques: wide-field confocal 2-photon Special techniques: FRET FLIM FRAP Photoactivation TIRF

Fluorescence excitation emission shorter wavelength, higher energy Excited state Ground state excitation shorter wavelength, higher energy emission longer wavelength, less energy  Stoke’s shift

Fluorophores (Fluorochromes, chromophores) Special molecular structure Aromatic systems (Pi-systems) and metal complexes (with transition metals) characteristic excitation and emission spectra

Excitation / emission Exitation filter Dichroic mirror (beamsplitter) Excitation/emission spectra always a bit overlapping filterblock has to separate them Exitation filter Dichroic mirror (beamsplitter) Emission filter

Excitation / emission

Filter nomenclature Excitation filters: x Emission filters: m Beamsplitter (dichroic mirror): bs, dc, FT 480/30 = the center wavelength is at 480nm; full bandwidth is 30 [ = +/- 15] BP = bandpass, light within the given range of wavelengths passes through (BP 450-490) LP = indicates a longpass filter which transmits wavelengths longer than the shown number and blocks shorter wavelengths (LP 500) SP = indicates a shortpass filter which transmits wavelengths shorter than the shown number, and blocks longer wavelengths

Excitation / emission  No filter can separate these wavelengths! excitation and emission spectra of EGFP (green) and Cy5 (blue) excitation and emission spectra of EGFP (green) and Cy2 (blue)  No filter can separate these wavelengths!

Where to check spectra? You can plot and compare spectra and check spectra compatibility for many fluorophores using the following Spectra Viewers. Invitrogen Data Base   BD Fluorescence Spectrum Viewer University of Arizona Data Base NCI ETI Branch flow Cytometry 

Standard techniques wide-field confocal 2-photon

Wide-field fluorescence reflected light method Multiple wavelength source (polychromatic, i.e. mercury lamp) Illumination of whole sample  upright Zeiss microscopes, fluorescence tissue culture microscopes, timelapse microscopes

PFS timelapse New long term timelapse (Nikon) System adjusts the focus by using IR laser to measure the distance to the glass of your dish

Wide-field vs confocal Wide-field image confocal image Molecular probes test slide Nr 4, mouse intestine

Confocal method to get rid of the out of focus light  less blur whole sample illuminated (by scanning single wavelength laser) only light from the focal plane is passing through the pinhole to the detector

Confocal Use: to reduce blur in the picture  high contrast fluorescence pictures (low background) optical sectioning (without cutting); 3D reassembly possible Careful: increasing image size (more pixels) does not mean that the objective can resolve the same!!! (resolution determined by NA, a property of the objective)

Timelapse with confocal You can do timelapse movies with the confocal. Mainly for fast processes Be aware that not all our confocals have incubation chamber and CO2!  Two Leica confocals and one Olympus FV 1000

2-photon microscopy Excitation: long wavelength (low energy) Excited state Ground state Excitation: long wavelength (low energy) Each photon gives ½ the required energy Emission: shorter wavelength (higher energy) than excitation

2-photon microscopy Advantages:  Use for deep tissue imaging Use of lower energy light to excite the sample (higher wavelength) 1-photon: 488nm 2-photon: 843nm Advantages: IR light penetrates deeper into the tissue than shorter wavelength 2-photon excitation only occurs at the focal plane  less bleaching above and below the section  Use for deep tissue imaging  new La Vision microscope (live mouse imaging, will be installed in the new building)

Special applications: FRET and FLIM FRAP and photoactivation TIRF

FRET (Fluorescence Resonance Energy Transfer) method to investigate molecular interactions Principle: a close acceptor molecule can take the excitation energy from the donor (distance ca 1-10 nm) FRET situation: Excitation of the donor (GFP) but emission comes from the acceptor (RFP) No FRET Exited state Ground state Exited state Ground state Energy transfer, no emission! Exited state Ground state Donor (GFP) Acceptor (RFP)

FRET ways to measure: Acceptor emission Detect the emission of the acceptor after excitation of the donor, e.g. excite GFP with 488 but detect RFP at 610 (GFP emission at 520) Donor emission after acceptor bleaching take image of donor, then bleach acceptor (with acceptor excitation wavelength - RFP:580nm), take another image of donor  should be brighter!

FRET You need: a suitable FRET pair Disadvantages: (with overlapping excitation/emission curves) Disadvantages: Bleed through (because of overlapping spectra) Limitation of techniques (filters etc) Photobleaching only with fixed samples Intensity depends on concentrations etc

FLIM (Fluorescence Lifetime Imaging Microscopy) measures the lifetime of the excited state (delay between excitation and emission) every fluorophore has a unique natural lifetime lifetime can be changed by the environment, such as: Ion concentration Oxygen concentration pH Protein-protein interactions ∆t=lifetime

FLIM Lifetime histogram Excitation of many electrons at the same time  count the different times when they are falling back down (i.e. photons are emitted) lifetime = ½ of all electrons are fallen back decay curve

Example of FLIM-FRET measurement GFP expressed in COS 1 cell: average lifetime of 2523 ps fused GFP-RFP expressed in COS 1 cell: average lifetime of 2108 ps Joan Grindlay, R7

FLIM You still need: a suitable FRET-pair with the right orientation of the π-orbitals  Interaction of proteins is not enough, because fluorophores have to be close enough and in the right orientation! Use of FLIM: measurements of concentration changes (Ca2+), pH change etc, Protein interactions  FRET: Leica confocal 2 or Olympus FV 1000  FLIM: Leica confocal 1 and soon LIFA system from Lambert Instruments

Special applications: FRET and FLIM FRAP and photoactivation TIRF

FRAP (Fluorescence Recovery After Photobleaching) Intense illumination with 405 laser bleaches the sample within the selected region  observation of the recovery before 0.65 s 0.78 s  Olympus FV 1000 Use: to measure the mobility/dynamics of proteins under different conditions

photoactivation Fluorophore only becomes active (= fluorescent) if excited (e.g. with 405 laser) due to structural change Pictures taken from a activation movie: activation of a line trough the lamellipodia of the cell, activated GFP_F diffuses quickly  Olympus FV 1000

Special applications: FRET and FLIM FRAP and photoactivation TIRF

TIRF (Total Internal Reflection Fluorescence) You need: TIRF objectives with high NA TIRF condensor, where you are able to change the angle of illumination Glass coverslips

TIRF micro.magnet.fsu.edu Result: very thin section at the bottom of the sample  150-200nm Use: to study membrane dynamics (endocytosis, focal adhesions, receptor binding)  Nikon TE 2000

TIRF vs epi FAK-lasp in epi mode (wide field) FAK-lasp in tirf mode (wide field) Heather Spence, R10

TIRF vs epi Lasp in confocal sectioning Lasp in TIRF mode Heather Spence, R10

Summary/comparison method excitation detection sectioning use Wide field Whole sample No sectioning Simple fluorescence samples confocal One z-plane 350-500nm High contrast images, optical sectioning 2-Photon 500-700nm Deep tissue imaging, optical sectioning FLIM/FRET Protein interactions FRAP + photoactivation 405 laser (UV) dynamics/mobility TIRF Only bottom plane 150-200nm Membrane dynamics

Please book proper training with Tom or Margaret before using BAIR equipment!

BAIR webpage demonstration: