THEMIS End of Prime Mission ReviewESA- 1 UCB, November, 19 2009 ESA Plasma Instrument End of Prime Mission Review Dr. James McFadden and Dr. Charles Carlson.

Slides:



Advertisements
Similar presentations
MPSRESA- 1 UCB, Oct 26, 2006 THEMIS MISSION PRE-SHIP REVIEW ESA C. Carlson, M. Ludlam, J. McFadden University of California - Berkeley.
Advertisements

The Origins of X-Rays. The X-Ray Spectrum The X-Ray Spectrum (Changes in Voltage) The characteristic lines are a result of electrons ejecting orbital.
Solar system science using X-Rays Magnetosheath dynamics Shock – shock interactions Auroral X-ray emissions Solar X-rays Comets Other planets Not discussed.
STEREO IMPACT Critical Design Review 2002 November 20,21,22 1 LET Performance Requirements Presenter: Richard Mewaldt
LSU 10/09/2007System Design1 Project Management Unit #2.
THEMIS MISSION PDRESA- 1 UCB, November, 2003 ESA Plasma Instrument Mission PDR Dr. C. W. Carlson and Themis ESA Team UC Berkeley SSL.
Brief introduction of YINGHUO-1 Micro-satellite for Mars environment exploration J. Wu, G. Zhu, H. Zhao, C. Wang, L. Lei, Y. Sun, W. Guo and S. Huang Center.
Van Allen Probes Spacecraft Operations July 29, 2015 Kristin Fretz
THEMIS Instrument Suite PEREFI- 1 UCB, May 2, 2005 THEMIS Solid State Telescope (SST) Instrument Suite PER The THEMIS SST, IDPU and II&T Teams.
THEMIS MISSION CDRESA- 1 UCB, June THEMIS T IME H ISTORY OF E VENTS AND M ACROSCALE I NTERACTIONS DURING S UBSTORMS RESOLVING THE MYSTERY.
THEMIS Mission PDR/CAR 1 UCB, November 12-14, 2003 Search Coil Magnetometer (SCM) Mission PDR/CAR Alain Roux CETP-Velizy Co-i: O.Le Contel Technical Manager:
CODIF Status Lynn Kistler, Chris Mouikis Space Science Center UNH July 6-8, 2005 Paris, France.
THEMIS Workshop 1 UC Berkeley, 18 December 2004 Data Products and Access Tim Quinn UC Berkeley.
THEMIS/SRR ESA- 1 UCB, 06/08/2003 THEMIS Electrostatic Analyzer (ESA) instrument David W. Curtis Space Sciences Laboratory University of California, Berkeley.
THEMIS SRR 1 UCB, June 8-9, 2003 Solid State Telescope Davin Larson SSL.
1 THEMIS Inner Magnetosphere Review, Dec 20, 2008 Summary of THEMIS results in the inner magnetosphere Future mission operations discussion: –Science targets.
ARTEMIS from a Planetary Perspective 1 September 9, 2008 THEMIS Extended Phase = THEMIS baseline + ARTEMIS Vassilis Angelopoulos, and the ARTEMIS team.
THEMIS ESA SWT ESA- 1 UCB, Aug ESA In-Flight Calibration and First Results J. McFadden, C. Carlson, D. Larson UC Berkeley SSL.
SS Space Science MO&DA Programs - August Page 1 ACE Instrument Status Report Cosmic Ray Isotope Spectrometer (CRIS) Normal Operation. Electron Proton.
Simple Approach to Salvaging THEMIS ESA Moments Prior to Boom Deployment Vladimir Kondratovich David G. Sibeck.
Improving Detection Efficiency of a Space-based Ion Mass Spectrum Analyzer Anne Lamontagne, University of New Hampshire; Mark Popecki, UNH; Lynn Kistler,
IMPORTANCE OF FAST MEASUREMENTS OF SOLAR WIND PARAMETERS AT THE IP SHOCK FRONT Moscow, February 6-10, 2012 Z. Němeček, J. Šafránková, L. Přech, O. Goncharov,
1 MAVEN PFP ICDR May 23-25, 2011 Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission Particles and Fields Science Critical Design Review May ,
1 SWEA pre-CDR Peer Review Particles and Fields Package (PFP) SWEA pre-CDR Peer Review Integration and Test 2011 March 29 Dave Mitchell.
THEMIS SUITE PRE-ENVIRONMENTAL REVIEW 1 UCB May 2, 2005 THEMIS Pre-Environmental Review Instrument Verification Overview Ellen Taylor University of California.
THEMIS IDPU PDR I&T REQUIREMENTS- 1 UCB, October 16, 2003 I&T REQUIREMENTS Ellen Taylor University of California - Berkeley.
THEMIS INSTRUMENT PDROVERVIEW- 1 UCB, October 15, 2003 THEMIS SYSTEM OVERVIEW Dr. Vassilis Angelopoulos, Science Overview Dr. Ellen Taylor, Mission and.
Dec 1, FIELDS Top Level Requirements Review S. Harris (UCB)
Lecture 3-Building a Detector (cont’d) George K. Parks Space Sciences Laboratory UC Berkeley, Berkeley, CA.
SWT Overview 1 UCB, Nov15/16, 2006 THEMIS SCIENCE WORKING TEAM MEETING Mission Overview Peter R. Harvey Project Manager University of California - Berkeley.
Measurements Measurements and errors : - Here, the goal is to have some understanding of the operation and behavior of electrical test instruments. Also,
THEMIS MISSION PDRINSTRUMENT OVERVIEW- 1 UCB, November, 2003 THEMIS INSTRUMENT PAYLOAD SYSTEM OVERVIEW Dr. Ellen Taylor University of California - Berkeley.
How ARTEMIS Contributes to Key NLSI Objectives C.T. Russell, J. Halekas, V. Angelopoulos, et al. NLSI Lunar Science Conference Ames Research Center Monday,
THEMIS Engineering Peer Review 1 UCB, October 15-16, 2003 Electric Field Instrument (EFI) Operational Concept.
THEMIS SOCScience Data Products − 1March 29, 2006 Science Data Products Timothy Quinn.
Zou Ziming 1 Ma Wenzhen Li Lei Zhao Hua Wang Chi 1: Center for Space Science and Applied Research Chinese Academy of Sciences Moscow ·
CAMMICE Science Report March 31, 2006 There will be two sections to the report: 1.A discussion on the inter-comparison of the responses of the MICS, Hydra,
SST- Solid State Telescope ESA - Electrostatic Analyzer Science Measurement and Operational Requirements.
THEMIS MRRSystems - 1 GSFC, Jan 5, 2007 Systems Engineering.
THEMIS SRR Mission Requirements - 1 UCB July MISSION REQUIREMENTS Ellen R. Taylor Mission Systems Engineer Space Science Laboratory University.
THEMIS Instrument PDR 1 UCB, October 15-16, 2003 ESA & SST (ETC) Interface Board Preliminary Design Review Robert Abiad University of California - Berkeley.
THEMIS ESA SWG ESA- 1 UNH, Sept 22, 2008 ESA STATUS J. McFadden UC Berkeley SSL.
THEMIS ESA SWG ESA- 1 UCB, Dec 20, 2008 ESA STATUS J. McFadden UC Berkeley SSL.
THEMIS CDR 1 UCB, June 16, 2004 ESA & SST (ETC) Interface Board Critical Design Review Robert Abiad University of California - Berkeley.
THEMIS Instrument CDR 1 UCB, April 20, 2004 ESA & SST (ETC) Interface Board Critical Design Review Robert Abiad University of California - Berkeley.
FM4/FM5 IPSRSYS - 1 UCB, May 5, 2006 THEMIS INSTRUMENT SUITE FM4/FM5 PRE-SHIP REVIEW SYSTEM OVERVIEW Ellen Taylor University of California - Berkeley.
15 th CAA Cross-Calibration Workshop, 17th – 19th April 2012, UCL, London PEACE OPS TEAM Presented by Natasha Doss UCL Department of Space and Climate.
14 th CAA Cross-Calibration Workshop, 5th – 7th October 2011, York, UK PEACE OPS TEAM Presented by Natasha Doss UCL Department of Space and Climate Physics.
CIS Action Items 10 th Cross-Calibration Workshop Observatoire de Paris, Nov
8th Cross-calibration Workshop CIS data delivery report Kinsale – October 2008.
1 Summary Lecture: Part 1 Sensor Readout Electronics and Data Conversion Discovering Sensor Networks: Applications in Structural Health Monitoring.
Status of CIS Calibration Work Iannis Dandouras and the CIS Team presented by: Harri Laakso 3 rd CAA Cross-Calibration Meeting MSSL, October 2006.
CAA 6 th Cross Cal Meeting RAL, th Oct 2007 RAPID/IES Calibration Status J.A. Davies.
CODIF CORSS-CALIBRATIONS C. Mouikis, L. Kistler, K. Genestreti UNH 10th CAA Cross-Calibration meeting L'Observatoire de Paris, Paris, 2-4 November 2009.
26th Oct 2006CAA cross cal meeting, MSSL RAPID Calibration Status RAPID team.
Measurement of the CR light component primary spectrum B. Panico on behalf of ARGO-YBJ collaboration University Rome Tor Vergata INFN, Rome Tor Vergata.
Status of CIS Calibration and Archival Activities Iannis Dandouras, Alain Barthe, Lynn Kistler, and the CIS Team 4th CAA Cross-Calibration Meeting LPCE,
CIS Calibration Status Lynn Kistler, Chris Mouikis Adrian Blagau Iannis Dandouras, Alain Barthe 22 th Cross-Calibration Meeting, Tenerife, November 2015.
University of California - Berkeley
LET Performance Requirements Presenter: Richard Mewaldt
SWIA Front End Peer Review
RAPID/IES Calibration Status Rutherford Appleton Lab
Cross-Calibration Meeting ESTEC, February 2006
Time Series Analysis of Particles and Fields data
Solar Wind Core Electrons
THEMIS multi-spacecraft observations of a 3D magnetic
Measurements Measurements and errors :
Space activities at Charles University
THEMIS baseline + ARTEMIS
Project Management Unit #2
Presentation transcript:

THEMIS End of Prime Mission ReviewESA- 1 UCB, November, ESA Plasma Instrument End of Prime Mission Review Dr. James McFadden and Dr. Charles Carlson UC Berkeley SSL

THEMIS End of Prime Mission ReviewESA- 2 UCB, November, Requirements and Specifications Measurement The ESA instrument measures 3-D electron and ion energy distribution functions over the Energy range 10 eV to 30 keV. Typical energy sweep has 16 or 32 energy samples A full 4-pi distribution measurement is produced during each spin Sweep rate of 32/spin gives dense sample of 3-D particle distributions Raw measurements are compressed to selectable “reduced distributions” and moments Implementation Ion and electron “top-hat” electrostatic analyzers have 180 degree field of view Field of view is divided into 8 electron and 16 ion elevation bins Plasma analyzers have hardware programmed functions: sweep rate, sweep waveform, energy range, data collection rates. These functions are set by command. Higher level data formatting and computed products are carried out in the ETC board. Energy sweep is exponential with programmable starting energy and step ratio ESA Plasma Instrument continues to operate nominally producing high quality data products with no anomalous behavior.

THEMIS End of Prime Mission ReviewESA- 3 UCB, November, Block Diagram Electronics functional design is identical to FAST (with ACTEL upgrades) Three circuit modules plug together for efficient assembly and test MCP pulse amplifiers are Amptek A121 with programmable gain All discrete logic, counters, and HV DAC drivers are Actel FPGAs HV supplies are a mature design built at UCB SSL

THEMIS End of Prime Mission ReviewESA- 4 UCB, November, ESA efforts to facilitate data analysis ESA data is available within 24 hrs after collection ESA instrument performance is described in two publications : McFadden, J.P., Carlson, C.W., Larson, D., Angelopoulos, V., Ludlam, M., Abiad, R., Elliott, B., Turin, P., Marckwordt, M. (2008), The THEMIS ESA plasma instrument and in-flight calibration, Space Sci. Rev., doi: /s McFadden, J.P., Carlson, C.W., Larson, D., Bonnell, J., Mozer, F., Angelopoulos, V., Glassmeier, K.-H., Auster, U. (2008), THEMIS ESA first science results and performance issues, Space Sci. Rev., doi: /s Detailed instrument parameters are available on the THEMIS ESA web page: Data products are describe on the THEMIS ESA web page: Sources of non-ideal response in ESA data are described on the THEMIS web site:

THEMIS End of Prime Mission ReviewESA- 5 UCB, November, REQUIREMENTESA DESIGN IN-1. The Instrument Payload shall be designed for at least a two-year lifetime Compliance. All 10 ESAs functioning nominally after 2.5 years. IN-2. The Instrument Payload shall be designed for a total dose environment of 33 rad/year (66 krad for 2 year mission, 5mm of Al, RDM 2) Compliance. No evidence of radiation degradation of the detectors or of the electronics. IN-3. The Instrument Payload shall be Single Event Effect (SEE) tolerant and immune to destructive latch-up Compliance. No SEEs or latch-ups of the ESA sensors. IN-7. No component of the Instrument Payload shall exceed the allocated mass budget in THM-SYS-008 THEMIS System Mass Budget.xls Compliance. No mass budget problem. IN-9. No component of the Instrument Payload shall exceed the power allocated in THM-SYS-009 THEMIS System Power Budget.xls Compliance. No power problems during 2.5 years. IN-13. The Instrument Payload shall survive the temperature ranges provided in the ICDs Compliance. No observed anomalies during eclipse. IN-14. The Instrument Payload shall perform as designed within the temperature ranges provided in the ICDs Compliance. No ESA temperature problems. Mission Requirements

THEMIS End of Prime Mission ReviewESA- 6 UCB, November, REQUIREMENTESA DESIGN IN-16 The Instrument Payload shall comply with the Magnetics Cleanliness standard described in the THEMIS Magnetics Control Plan Compliance. ESA complied and experienced no magnetic problems. IN-17 The Instrument Payload shall comply with the THEMIS Electrostatic Cleanliness Plan Compliance. ESA complied and experienced no electrostatic cleanliness problems. IN-18 The Instrument Payload shall comply with the THEMIS Contamination Control Plan Compliance. ESA complied and experienced no contamination problems. IN-19. All Instruments shall comply with all electrical specifications Compliance. ESA complied and experienced no electrical problems. IN-20. The Instrument Payload shall be compatible per IDPU-Instrument ICDs Compliance. ESA was compatible and experienced no communication problems with the IDPU and ETC. ETC table loading problems were resolved during commissioning phase prior to first tail season. IN-21. The Instrument Payload shall be compatible per the IDPU-Probe Bus ICD Compliance. ESA was compatible. IN-23 The Instrument Payload shall verify performance requirements are met per the THEMIS Verification Plan and Environmental Test Spec. Compliance. ESA performance met the Verification Plan and Environmental Test Specification. IN-24 The Instrument Payload shall survive and function prior, during and after exposure to the environments described in the THEMIS Verification Plan and Environmental Test Specification Compliance. ESA survived all pre-launch testing and continues to function nominally. Mission Requirements

THEMIS End of Prime Mission ReviewESA- 7 UCB, November, REQUIREMENTESA DESIGN IN.ESA-1. The ESA shall obtain partial moments of the 3D plasma electron and ion distributions in the magnetotail plasma sheet Compliance. ESA partial moments are demonstrated to exceed science requirements. IN.ESA-2. The ESA shall measure differences in velocity and ion pressure between probes in the magnetotail plasma sheet Compliance. ESA provides the ETC board with plasma measurement data sufficient for computing the required moments. IN.ESA-3. The ESA shall measure ion and electron distributions that are associated with the current disruption process Compliance. ESA continues to measure 3-D distributions in the tail and throughout the magnetosphere, magnetosheath and solar wind. IN.ESA-4. The ESA shall be capable of measuring ion moments and differences of those moments in the magnetosheath and solar wind. Compliance. The ESA capability to accurately measure moments in the magnetosheath was demonstrated in the ESA instrument papers. Science Requirements

THEMIS End of Prime Mission ReviewESA- 8 UCB, November, REQUIREMENTESA DESIGN IN.ESA-5. The ESA shall measure ions and electrons over an energy range of 10eV to 30 keV Compliance. Satisfied by design. IN.ESA-6. The ESA energy sampling resolution, dE/E, shall be better than 25% FWHM for ions and electrons Compliance. Capability exceeds dE/E<25%, but implementation varies. Typical sampling resolution is ~31% for better dynamic range. IN.ESA-7. The ESA shall be capable of measuring i+ and e- energy flux of 10^4 to 10^9 keV/cm^2/s/Str/keV Compliance. Satisfied by design. IN.ESA-8. The ion ESA geometric factor shall be attenuated in the solar wind to avoid saturation. Compliance. High fluxes of solar wind ions are accommodated by small area anodes. Testing shows detectors do not saturate however dead- time corrections are needed. IN.ESA-9. The ESA shall supply partial energy moments at one spin time resolution. Compliance. Satisfied by design. IN.ESA-10. The ESA shall have a 180 deg. elevation FOV with a minimum angular resolution of 22.5 deg. Compliance. Satisfied by design. IN.ESA-11. To resolve the solar wind, the ESA shall have a FOV with enhanced resolution of ~ 6 deg. Compliance. Satisfied by design. IN.ESA-12. The ESA shall produce measurements of particle distributions over the entire 4pi steradian field of view in one spin period. Compliance. Satisfied by design. IN.ESA-13. ESA calibration shall ensure <20% relative flux uncertainty (not including statistical uncertainty) over the ranges defined above. Compliance. In-flight relative calibrations indicate relative flux errors are<5%. Performance Requirements

THEMIS End of Prime Mission ReviewESA- 9 UCB, November, ESA Moment Accuracy ESA data demonstrated to be accurate in when ESA energy range contains all significant plasma. Ne=Ni Pressure balance demonstrated across the magnetopause.

THEMIS End of Prime Mission ReviewESA- 10 UCB, November, Bow Shock and Foreshock Good density agreement in sheath & foreshock where ions are hot.

THEMIS End of Prime Mission ReviewESA- 11 UCB, November, Solar Wind Measurements Solar wind mode allows the THEMIS ESAs, which were not optimized for the intense solar wind ion flux, to perform adequately, without saturation as demonstrated by Ni=Ne. With corrections for s/c charging, solar wind electrons are accurately measured as demonstrated by agreement between components of Vi and Ve.

THEMIS End of Prime Mission ReviewESA- 12 UCB, November, Cross Calibration with EFI eSST eESA iSST iESA Ni Ne Vx Vy VzVx Vy Vz V ll V perp E x -VxB x E y -VxB y E z -VxB z Ex Ey EzEx Ey Ez Bx By BzBx By Bz

THEMIS End of Prime Mission ReviewESA- 13 UCB, November, ESA and SST combined Accurate density measurements Errors in electron velocity measurements due to density fluctuations

THEMIS End of Prime Mission ReviewESA- 14 UCB, November, MCPs monitored monthly ESA’s MCP detectors have been monitored monthly since the commissioning phase to test for any degradation and to maintain proper gain. The tests toggle the preamplifier threshold between the nominal value of ~30 fC to a value equal to the nominal gain (~160 fC). Variations in counts that are less than a factor of 2 demonstrate good MCP detector gain. MCPs show little evidence of any average degradation. MCP bias voltages have not required changes for a year. Ions Electrons

THEMIS End of Prime Mission ReviewESA- 15 UCB, November, Intense Solar Wind Ions Concern existed that intense solar wind ions might saturate the MCP detectors and degrade response. Detector threshold is toggled from nominal values through increasing threshold level to reveal actual MCP gain. These tests show that MCPs signals decrease in amplitude, but not enough to impact detection at nominal threshold. Solar wind electrons with nominal MCP full threshold toggle test provide a baseline for comparison. Ions Electrons

THEMIS End of Prime Mission ReviewESA- 16 UCB, November, Bremsstrahlung Background Energetic electrons measured by the SST detectors produce X- rays that contaminate the ion ESA measurement. Moment calculations without removal of this background will overestimate ion density (green). Simple background removal algorithms (black) help, but still do not provide good agreement with electron density (red). Ions Electrons

THEMIS End of Prime Mission ReviewESA- 17 UCB, November, eSST Determines iESA Bgnd We estimate background using both the eSST and iESA data. Cross fitting these two estimates allows corrections due to changes in response with time. Using eSST rather than iESA estimate eliminates removal of real counts at low energy. Ions Electrons Background Density after background subtraction

THEMIS End of Prime Mission ReviewESA- 18 UCB, November, ESA Non-ideal Behavior ESA data is not perfect and the THEMIS web site and instrument papers outline sources of non-ideal response. For example, even with accurate density measurements, errors in electron velocity measurements may be present due to density fluctuations on the time scale of the spacecraft spin period.

THEMIS End of Prime Mission ReviewESA- 19 UCB, November, Electron ESA MCP degradation Response after first tail season. Another minor source of non- ideal behavior was discovered after the first tail season, when the eESA experienced high count rates at low energy due to photo- electrons from the axial booms. This change in detector response necessitated modifications to the ground software and added several months to the in-flight calibration effort. Such changes were necessary in order to get accurate electron moments, especially in the solar wind. Response before first tail season.

THEMIS End of Prime Mission ReviewESA- 20 UCB, November, ESA Lessons Learned Analyzer concentricity essential to good measurements and can be easily achieved with a good design. Tuning the analyzers to have identical energy sweeps greatly simplifies data analysis and in-flight calibrations. Coast phase with close proximity of multiple satellites greatly simplifies cross calibration of instruments. Fast signal amplifiers (short dead-time) are essential for ESAs on magnetospheric missions. Multiple data products that complement each other greatly simplify data analysis and in-flight calibration efforts. Built in test electronics simplifies in-flight instrument monitoring. Leakage fields through analyzer grids can impact sensor response MCP droop in intense solar wind not important. Two electron sensors looking in opposite directions are essential for accurate Ve measurements when density fluctuations are present. Ebanol-C is better than Gold Black for UV rejection. Combined plasma measurements (ESA+SST) are required for correct plasma moment calculations.

THEMIS End of Prime Mission ReviewESA- 21 UCB, November, Publication History and Data Maturity THEMIS Papers utilizing ESA Data: 2008 – 2 ESA instrument papers published 2008 – 22 science papers published 2009 – 26 papers published to date 2009 – >16 papers submitted Data Analysis Software ESA raw and level 2 data available within ~24 hrs of collection. Data analysis tools available to all, regular improvement to software. Level 2 data is regenerated after significant changes to software. Data will continue to improve with age like a good bottle of wine. The ESA team will continue to assist the science community, facilitating access to ESA data and evaluating proper use of these data, when possible, within our limited resources.

THEMIS End of Prime Mission ReviewESA- 22 UCB, November, Summary Performance ESA Prime mission requirements No failures or anomalies during prime mission ESA met all mission and science requirements ESA met or exceeded all performance requirements ESA team has provided software and calibrated data Over 50 papers with ESA data published ESA Current Status No noticeable degradation of HV sweep supplies MCPs have >1kV head room for future bias voltage increases if needed No increase in background noise since launch In-flight calibrations correct for low-energy localized degradation of electron detectors No significant localized degradation for ion sensors exposed to intense solar wind fluxes.

THEMIS End of Prime Mission ReviewESA- 23 UCB, November, Future Improvements ESA Data Work in Progress Bremsstrahlung X-ray background subtraction GF corrections for eESA low energy MCP degradation New software algorithms for more accurate moments New software algorithms to handle glitches in s/c potential Algorithms to calculate density based on s/c potential ESA Planned Developments Scattered electron background subtraction Composition estimates based on Ne/Ni differences S/C potential estimates of density More accurate dead-time corrections for solar wind ions