Lead Tungsten Uranium Tin Iron Tantalum Abstract Muon tomography aims at detecting and 3D-imaging well-shielded high-Z material, e.g. nuclear contraband.

Slides:



Advertisements
Similar presentations
Cosmic Ray Test of INO RPC Stack M. Bhuyan 1, V.M. Datar 2, S.D. Kalmani 1, S.M. Lahamge 1, N.K. Mondal 1, P. Nagaraj 1, S. Pal 1, L.V. Reddy, A. Redij.
Advertisements

Kondo GNANVO Florida Institute of Technology, Melbourne FL.
Prototype of a Muon Tomography Station with GEM Detectors for Detection of Shielded Nuclear Contraband Michael Staib1 V. Bhopatkar1, W. Bittner1, K. Gnanvo1,2,
Data Acquisition System for 2D X-Ray Detector Beijing Synchrotron Radiation Facility (BSRF) located at Institute of High Energy Physics is the first synchrotron.
Directional Detectors and Digital Calorimeters Ed Norbeck and Yasar Onel University of Iowa For the 25 th Winter Workshop on Nuclear Dynamics Big Sky,
The first testing of the CERC and PCB Version II with cosmic rays Catherine Fry Imperial College London CALICE Meeting, CERN 28 th – 29 th June 2004 Prototype.
Muon Tomography with compact Gas Electron Multiplier Detectors Dec. Sci. Muon Summit - April 22, 2010 Marcus Hohlmann, P.I. Florida Institute of Technology,
Design and Construction of a First Prototype Muon Tomography System with GEM Detectors for the Detection of Nuclear Contraband M. Hohlmann 1, K. Gnanvo.
We have no control on the slow and sparse incoming muon flux Visualizing sufficient scattered POCA points in target volume satisfactorily takes long time.
A First Application for the Scalable Readout System: Muon Tomography with GEM Detectors RD51 Collaboration Meeting WG5 - May 25, 2010 Marcus Hohlmann with.
2012 IEEE Nuclear Science Symposium Anaheim, California S. Colafranceschi (CERN) and M. Hohlmann (Florida Institute of Technology) (for the CMS GEM Collaboration)
Emulator System for OTMB Firmware Development for Post-LS1 and Beyond Aysen Tatarinov Texas A&M University US CMS Endcap Muon Collaboration Meeting October.
SPHENIX GEM Tracker R&D at BNL Craig Woody BNL sPHENIX Design Study Meeting September 7, 2011.
Experience with medium-size SRS for muon tomography Michael Staib Florida Institute of Technology.
Update on APV25-SRS Electronics Kondo Gnanvo. Outline Various SRS Electronics Status of the APV25-SRS UVa Test of the SRU with multiple.
Online Monitoring and Analysis for Muon Tomography Readout System M. Phipps, M. Staib, C. Zelenka, M. Hohlmann Florida Institute of Technology Department.
Prototypes For Particle Detectors Employing Gas Electron Multiplier
Performance Expectations for a Tomography System Using Cosmic Ray Muons and Micro Pattern Gas Detectors for the Detection of Nuclear Contraband Kondo Gnanvo,
Large-area Gas Electron Multiplier Detectors for a Muon Tomography Station and its Application for Shielded Nuclear Contraband Detection K. Gnanvo 1, L.
Strip No Detection and Imaging of High-Z Materials with a Muon Tomography Station using GEM Detectors K. Gnanvo 1, W. Bittner 1, B. Benson 1, F. Costa.
Monte Carlo simulations of a first prototype micropattern gas detector system used for muon tomography J. B. Locke, K. Gnanvo, M. Hohlmann Department of.
Simulation of an MPGD application for Homeland Security Muon Tomography for detection of Nuclear contraband Kondo Gnanvo, M. Hohlmann, P. Ford, J. Helsby,
An MPGD Application: Muon Tomography for Detection of Nuclear Contraband Marcus Hohlmann, P. Ford, K. Gnanvo, J. Helsby, R. Hoch, D. Mitra Florida Institute.
HallA/SBS – Front Tracker PARAMETERDESIGN VALUE Microstrip Silicon Detector Number of tiles/plane and size2 Number of planes2 Size of the single
75 th Annual Meeting March 2011 Imaging with, spatial resolution of, and plans for upgrading a minimal prototype muon tomography station J. LOCKE, W. BITTNER,
WP4 STATUS AND OUTLOOK Hartmut Hillemanns TTN Meeting, December
First MT Prototype Station GEM Detectors for Muon Tomography of Nuclear Contraband A. Quintero 1, K. Gnanvo 1, L. Grasso 1, J. B. Locke 1, D. Mitra 2,
Statement of Interest in CMS MPGD High-  Muon Upgrade Florida Tech CMS Muon Group Marcus Hohlmann Florida Institute of Technology, Melbourne, FL, USA.
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
LHCb VErtex LOcator & Displaced Vertex Trigger
GEM Trackers for Super BigBite Spectrometer (SBS) in Hall JLab The Super Big Bite Spectrometer (SBS) is one of the major new equipment in hall A in.
ATLAS micromegas activities (MAMMA)
News on GEM Readout with the SRS, DATE & AMORE
Apollo Go, NCU Taiwan BES III Luminosity Monitor Apollo Go National Central University, Taiwan September 16, 2002.
Update on the Triple GEM Detectors for Muon Tomography K. Gnanvo, M. Hohlmann, L. Grasso, A. Quintero Florida Institute of Technology, Melbourne, FL.
Status of Muon Tomography with SRS at FIT and some early beam results with SRS Michael Staib, Marcus Hohlmann Florida Institute of Technology Kondo Gnanvo.
GEM Detector R&D at Florida Tech – “Get to know each other” –
2009 Florida Academy of Sciences at Saint Leo University, Saint Leo, Florida Performance comparison of the triple gas electron multiplier (GEM) and the.
M. Staib, M. Abercrombie, B. Benson, K. Gnanvo, M. Hohlmann Department of Physics and Space Sciences Florida Institute of Technology.
Live Event Display and Monitoring Program for a Muon Tomography Station Michael Phipps, Judson Locke, Michael Staib; Adviser: Dr. Marcus Hohlmann Department.
Florida Institute of Technology, Melbourne, FL
 The zigzag readout board is divided into eight η-sectors; each sector has a length of ~12 cm and comprises 128 zigzag strips; zigzag strips run in radial.
Large-Area GEM Detector Development at CMS, RD51, and Fl. Tech – A brief overview – Marcus Hohlmann Florida Institute of Technology, Melbourne, FL PHENIX.
Cost Reduction for Gas Electron Multiplier Detector Readout Boards Using Zigzag Strips Elizabeth Starling Marcus Hohlmann Kimberley Walton, Aiwu Zhang.
GEM-based Muon Tomography of Shielded High-Z Materials 10 th RD51 Collaboration Meeting, Stony Brook U., Oct 1, 2012 Marcus Hohlmann Florida Institute.
09/10/2010 RD51 Collaboration Meeting Cisbani-Musico-Minutoli / Status JLab Electronics 1 Status of the APV25 electronics for the GEM tracker at JLab Evaristo.
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
Quality control for large volume production GEM detectors Christopher Armaingaud On behalf of the collaboration GEMs for CMS.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
Construction and beam test analysis of GE1/1 prototype III gaseous electron multiplier (GEM) detector V. BHOPATKAR, E. HANSEN, M. HOHLMANN, M. PHIPPS,
Abstract Muon tomography for homeland security aims at detecting well-shielded nuclear contraband in cargo and imaging it in 3D. The technique exploits.
RD51 GEM Telescope: results from June 2010 test beam and work in progress Matteo Alfonsi on behalf of CERN GDD group and Siena/PISA INFN group.
Detecting shielded nuclear contraband using muon tomography Judson Locke, William Bittner, Leonard Grasso, Dr. Kondo Gnanvo; Adviser: Dr. Marcus Hohlmann.
Abstract Muon tomography for homeland security aims at detecting well- shielded nuclear contraband in cargo and imaging it in 3D. The technique exploits.
J. Helsby, P. Ford, R. Hoch, K. Gnanvo, R. Pena, M. Hohlmann, D. Mitra
Slow Control and Run Initialization Byte-wise Environment
Slow Control and Run Initialization Byte-wise Environment
Electronics for GEM R&D at the University of Virginia
Part XII Homeland security.
PRAD DAQ System Overview
A. Zhang, S. Colafranceschi, M. Hohlmann
ALICE – First paper.
Large CMS GEM with APV & SRS electronics
Nathan Mertins, Michael Staib, William Bittner
Characterization and test beam results of novel triple-GEM
Development of Gas Electron Multiplier Detectors for Muon Tomography
EIC Tracking Meeting, March 26, 2012
J. Twigger, V. Bhopatkar, E. Hansen, M. Hohlmann, J.B. Locke, M. Staib
A. Zhang, S. Colafranceschi, M. Hohlmann
Presentation transcript:

Lead Tungsten Uranium Tin Iron Tantalum Abstract Muon tomography aims at detecting and 3D-imaging well-shielded high-Z material, e.g. nuclear contraband in cargo, for homeland security and other applications. This zero-dose technique exploits multiple scattering of atmospheric cosmic ray muons, which is larger in dense, high-Z nuclear materials than in low-Z and medium-Z shielding materials. We are operating a compact Muon Tomography Station that tracks muons using 30cm × 30cm Triple Gas Electron Multiplier (GEM) detectors with 2D readout placed on four sides of a 27-liter cubic imaging volume. Data from ~12,000 strips are acquired with an RD51 Scalable Readout System. We present experimental performance of this station, specifically the imaging performance for shielded uranium. With typically 100k reconstructed muon tracks, the station can resolve the gap between two high-Z objects placed at least 6mm apart in the horizontal plane. It images a 75cc depleted uranium cube shielded on all sides by ~2cm thick medium-Z bronze material. The same cube can be imaged through vertical clutter of 12cm of low-Z steel shielding. Sizes and 3D shapes of metallic objects with dimensions of a few cm that are shielded by a lead box with 3.4mm walls on all sides have been reconstructed successfully. Using the observed scattering signatures, these shielded objects can be distinguished from each other according to their radiation lengths including clearly distinguishing uranium from lead. A scaled-up muon tomography station with cubic meter active volume will use compact tracking stations with large-area GEM detectors in the future. 27-lit. Muon Tomography Station with 8 GEMs Muon Tomograms of Various Shielded Target Scenarios DAQ Hardware & Software Acknowledgments & Disclaimer We thank the RD51 collaboration and the GDD at CERN for their extensive technical support. This material is based upon work previously supported in part by the U.S. Department of Homeland Security under Grant Award Number 2007-DN-077- ER The views and conclusions presented here are those of the authors and should not be interpreted as necessarily representing the official policies, either expressed or implied, of the U.S. Department of Homeland Security. We plan to improve the track reconstruction further, e.g. by including additional detector layers and more robust hit and track selection algorithms to reduce the number of improperly assigned tracks. The alignment can be improved by taking relative detector rotations into account in addition to the currently implemented relative shifts. There is also a need to suppress zeroes in the data at the DAQ firmware level to reduce the overall raw data size and speed up data processing. We anticipate the construction of a larger MTS prototype with 1m 3 volume using 1m long GEM chambers similar to those that have been developed recently by the CMS GEM and RD51 collaborations and use of time-of-flight information. The >12k analog channels are digitized at 40MHz and read out at ~35 Hz using the largest implementation of the RD51 Scalable Readout System (SRS) to-date. The SRS was developed at CERN as a low–cost scalable DAQ system for specific use with micropattern gaseous detectors. Data are collected using a hybrid card based on the 128-channel APV25 chip and sent via HDMI cables to ADC cards which support 16 APV hybrids each. ADC data are formatted by a front end concentrator (FEC) based on the Virtex LX50T FPGA. Data from 6 FECs are sent via gigabit ethernet through two switches to a DAQ computer at 15 MB/s and processed for online and offline analysis using DATE and AMORE DAQ software developed for the ALICE experiment. Raw event size without zero suppression is ~500 kB. APV25 Hybrid Card (RD 51 series production) Imaging Shielded High-Z Nuclear Material with a Compact Muon Tomography Station Based on GEM Detectors M. Hohlmann, V. Bhopatkar, M. Phipps, M. J. Staib, J. Twigger, C. Zelenka Dept. of Physics and Space Sciences, Florida Institute of Technology, Melbourne, FL 32901, USA 3 Lead-Acid Batteries Impact of Side Detectors - XY Plane Triple-GEM Detectors Muon Tomography Concept Main Idea: Multiple Coulomb scattering is proportional to atomic number Z, allowing for discrimination of materials by Z. Tracking Detectors Triple-GEM Detector instrumented with 12 APV25 hybrid cards XY Slice Z = 20 mm 8mm gap LeadTungsten 0mm gap 2 mm increments LeadTungsten 8 mm horizontal gap6 mm horizontal gap4 mm horizontal gap 15 mm vertical gap 45 mm vertical gap Horizontal Scenario Lead Tungsten 15 mm gap 15 mm increments 45 mm gap Lead Tungsten Lead Tungsten Switch target positions 45mm gap (reversed) 380k reconstructed events with # neighboring POCA Cut = 5 Object B A X = -70 mm X = 50 mm SnFe Pb X = 0 mm W U Scattering angle: 159,955 reconstructed tracks # neighboring POCA Cut = 5 Vertical Scenario Prototype muon tomography station designed and built at Florida Tech. The design allows for adjustable station configurations including side detectors. The current configuration includes 8 triple-GEM detectors (yellow) surrounding four sides of a 1ft 3 (27 l) active volume. at Y = 0 mm at Y = -60 mm U Sn Fe Pb W XZ Slices at Y = 70 mm Future Work Image Resolution Achieved: ~6 mm horizontal & ~45 mm vertical Tests relative acceptance within probing volume and the effect from tracks through side detectors (in particular near the edges of the volume) 260k reconstructed events # neighboring POCA cut = 5 Multiple projections of materials shielded by 3.4 mm lead box Uranium Shielded by 1.7cm of Bronze Uranium shielded by 2 cm of Lead Point-of-Closest-Approach scattering reconstruction YZ Slice X = -20 mm XY Slice at Z = -70 mm XZ Slice at Y = 0 mm Ta Pb W Sn Fe U XY Slice Z = -60 mm Data fitted to 1/  X 0 (SSD = sum of all scattering angles within target volume per 1000 tracks) 3.4 mm top lead10 mm top lead placed inside Top/Bottom Detectors only Typical Integration times for all these scenarios: hrs. FeU Large Scattering Small Scattering μ Iron Small Scattering Uranium μ Large Scattering μ μ Incoming muons (from natural cosmic rays) Note: Angles Exaggerated! y x Top/Bottom & Side Detectors Slices 335k reconstructed events; # neighboring POCA Cut = 5 Ta YZ Slices U XY Slice